HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE WINIZSOR IMPACT
Street: \.�\ %_,_X_ - C��
Builder Name: WYNNE DEVELOPMENT
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(1432.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Inl Insul, Exterior
R=4.1 1224.00 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=11.0 208.00 ft2
c. NIA
R= ft2
4. Number of Bedrooms 3
d. WA
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1783.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1753.00 ft2
6. Conditioned floor area above grade (ft2) 1753
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(151.4 sgfQ Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U-Factor. Sgl, U=1.04 111.36 ft2
SHGC: SHGC=0.29
b. U-Factor. SgI, U=1.11 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor. NIA ft2
SHGC:
13. Healing systems
k8tu/hr Efficiency
d. U-Factor. NIA ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.850 ft.
Area Weighted Average SHGC: 0.285
14. Hot water systems
8. Floor Types (1753.0 sgft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2
b. Conservation features
EF: 0.970
b. NIA R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.086 Total Proposed Modified Loads: 52.20
PASS
Total Baseline Loads: 53.92
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
04TSiE$Tg7R
�, __ pA
Code.
calculation indicates compliances/,
' =� rs+
with the Florida Energy Code.
`a f
PREPARED BY:0
Before construction is completed
DATE: - -c
this building will be inspected for
compliance with Section 553.908
hereby certify that this building, as designed, i compliance
I
Florida Statutes.
�.
with the Florida Energy Code
OWNER/AM-
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factorysealed in accordance with lotioR403.3.2.1.
nsp �'
Compliance requires an Air Barrier and Insulation Inspection Chec iry a coY(lance rth 02.. his project requires an
envelope leakage test report with envelope leakage no greater than 00 9 "0.4.
REVIEWED FOR
CODE� aCOMPLIANCE
UNTY
1/8/2020 4:43 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBCcC`lh�dift`in1 0�)1 Com I�®Sofftware Pagel of 6
ROW
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Tifle: WYNNE THE WINDSOR IMP Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1753
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PiatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 0
Street:
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/EAsting: New (From Plans)
Comment:
CLIMATE
_ /
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1753 14024
,
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1 MASTER BEDROO
224 1792 No
0
1
1
Yes
Yes
Yes
2 WIC
63 504 No
0
1
No.
Yes
Yes
3 MASTER BATH
56 448 No
0
1
Yes
Yes
Yes
4 M. BATH
61 488 No
0
1
Yes
'Yes
Yes
5 LAUDRY
36 288 No
0
1
No
Yes
Yes
6 BEDROOM 2
180 1440 No
0
1
1
Yes
Yes
Yes
7 DINING/GREATR
688 4704 No
2
1
Yes
Yes
Yes
8 KITCHEN
209 1672 Yes
0
1
Yes
Yes
Yes
9 BATH
50 400 No
0
1
Yes
Yes
Yes
10 HALL
25 200 No
0
1
No
Yes
Yes
11 FOYER
92 736 No
0
1
Yes
Yes
Yes
12 BEDROOM 3
169 1352 No
0
1
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
MASTER BEDRO 37 It 0
224 ft'
_
0 1
0
2SIab-On-Grade Edge Insulatio
WIC 1 ft 0
63.W
_
0 1
0
3 Slab -On -Grade Edge Insulatio
MASTER BATH 8 ft 0
56 ft'
_
0 1
0
4 Slab -On -Grade Edge Insulatio
M. BATH 7 ft 0
61 ft'
_
0 1
0
5SIab-On-Grade Edge Insulatio
LAUDRY 111 0
36 ft'
—
0 1
0
1/8/2020 4A3 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT. SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet.
6SIab-On-Grade Edge Insulatio
BEDROOM 2 12ft
0
180 ft'
_
0 1
0
7SIab-On-Grade Edge Insulatio
DINING/GREAT 50 ft
0
588$'
0 1
0
_
8SIab-On-Grade Edge Insulatio
KITCHEN lift
0
209 ft'
_._
0 1
0
9 Slab -On -Grade Edge Insulatio
BATH 5 ft
0
50 ft'
_
0 1
0
_
10SIab-On-Grade Edge Insulatio
HALL 1 ft
0
25 ft'
_
0 1
0
11Slab-On-Grade Edge Insulatio
FOYER 9 ft
0
92 ft'
_--_
0 1
0
12SIab-On-Grade Edge Insulatio
BEDROOM 3 14 ft
0
169 ft'
-_
0 1
0
ROOF
/
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck Pitch
V
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip .Metal 1847 ft'
0 ft'
Light
N
0.4
No 0.9
No 0
18.4
ATTIC
# Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
17531t-
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented)
MASTER BEDRO
30
Blown
224 ft'
0.1
Wood
2 Under Attic (Vented)
WIC
30
Blown
63 ft'
0.1
Wood
3 Under Attic (Vented)
MASTER BATH
30
Blown
56 ft'
0.1
Wood
4 Under Attic (Vented)
M. BATH
30
Blown
61 ft'
0.1
Wood
5 Under Attic (Vented)
LAUDRY
30
Blown
36 tN
0.1
Wood
_
6 Under Attic (Vented)
BEDROOM 2
30
Blown
180 ft'
0.1
Wood.
7 Under Attic (Vented)
DINING/GREAT
30
Blown
588 ft'
0.1
Wood
8. Under Attic (Vented)
KITCHEN
30
Blown
209 ft'
0.1
Wood.
9 Under Attic (Vented)
BATH
30
Blown
50 ft'
0.1
Wood
10 Under Attic (Vented)
HALL
30
Blown
25 ft'
0.1
Wood
11 Under Attic (Vented)
FOYER
30
Blown
92 ft'
0.1
Wood
12 Under Attic (Vented)
BEDROOM 3
30
Blown
'
169 ft'
0.1
Wood
13 Knee Wall (Vented)
DINING/GREAT
,19
Blown
30 ft'
0.11
Wood
WALLS
Adjacent
Space Cavity Width
Height
Sheathing' Framing Solar
Below
0
1
E Exterior Concrete Block-
Int In30l1ASTER BE 4.1 16
0 8
0
128.0 ft''
0 0
0.3
0
2
W Exterior Concrete Block
- Int Ins01ASTER BE 4.1 7
0 8
0
'56.0 ft'
0 0
0.3
0
—3
S Exterior Concrete Block
- Int InsMASTER BE 4.1 14
0 8
0
112,0 ft2'
0 0
0.3
0
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FARM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
-VA
nm
Adjacent Space
Cavity Width
Height
Sheathing' Framing Solar Below
-4
E
Exterior
Concrete Block - Int InsWASTER BA
4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
5
E
Exterior
Concrete Block - Int Insul M. BATH
4.1 7
0
8 0
56.0 ft'
0
0.
0.3
0
-6
E
Exterior
Concrete Block- Int InsBEDROOM 2
4.1 12
0
8 0
96.0 ft'
0
0
0.3
0
-7
S
Exterior
Concrete Block- Int InsIRINING/GRE
4.1 30
0
8 0
240.0 ft'
0
0
0.3
0
-8
W
Exterior
Concrete Block- Int Ins(DINING/GRE
4.1 20
0
6 0
160.0 ft'
0
0
0.3
0
_ 9
W
Exterior
Concrete Block- Int InsulKITCHEN
4.1 11
0
8 0
88.0 ft'
0
0
0.3
0
_ 10
E
Exterior
Concrete Block- Int Insul BATH
4.1 5
0
8 0
40.0 ft'
0
0
0.3
0
11
N
Exterior
Concrete Block- Int Insul FOYER
4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
_ 12
N
Exterior
Concrete Block- Int Insul FOYER
4.1 1
0
8 0
8.0 ft'
0
0
0.3
0
_ 13
W
Exterior
Concrete Block- Int Ins6EDROOM 3
4.1 13
0
8 0
104.0 ft'
0
0
0.3
0
_ 14
N
Exterior
Concrete Block- Int InsffEDROOM 3
4.1 1
0
8 0
8.01?
0
0
0.3
0
15
N
Garage
Frame -Wood BEDROOM
11 26
8
208.0 ft'
0.23
0.3
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Insulated FOYER
None
.32
3
3
6 8
21.7 ft'
WINDOWS
Orientation shown is the entered orientation => chan ed to Worst Case.
_ /
Wall
Overhang
V
#
Omt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
S 3
Metal Low-E Single Yes
1.04 0.29
N
32A ft2
1 ft 0 in
1 ft 5 in,
Drapesiblinds
Exterior 5
2
E 5
Metal Low-E Single Yes
1.04 0.29
N
6.9 ft2
1. It 0In
1 ft 5 in
None
None
_
3
E 6
Metal Low-E Single Yes
1.04 0.29
N
16.2 ft
1 It 0 in
1 ft 5 in
None
None
_
4
S 7
Metal Low-E Single Yes
1.04 0.29
N
39.8 It'
1 it 0 in
1 it 5 in
None
None
_
5
W 8
Metal Low-E Single Yes
1.11 0.27
N
40.0 ft2
8 it 0 In
1 ft 5 in
None
None
_
6
W 13
Metal Low-E Single Yes
1.04 0.29
N
16.2 ft2
1 It 0 in
1 ft 5 in
Drapeslblinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
806 IF 806 ft2
26 ft
8
it
11
INFILTRATION
# Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000254 1168.7 64.16
120.66
.0881
5
1/812020 4:43 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY -CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Singl HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 34.8 kBtulhr cfm
0.85 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
/ —Supply—
—Return
Air
CFM 25 CFM25
HVAC#
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT ON RLF
Heat Coal
1 Attic 6 175 1112
Attic
55 ft2 Default Leakage
Attic
(Default) (Defalilt)
1 1
TEMPERATURES
Programablee T]hermostafXt:'JY
Ceiling Fans:
fXj'�
Heating [X) Jan Feb Mar
f
AApp` [
0(I �X]
May I ] Jun [ ] Jul
0C]
I' ] Aug
[X]
(] Sep
[ ] r0('I
L.l
H
1NovrX'I Dee
Venting [( 11 Jan [)Feb [X) Mar
l l lxl
[
t 1 Jun O Jul
t 1 Aug
[) Sep
lxl Oct Nov
[ ]Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6
7
8 9
10 11
12
Cooling (WD)
80
80 78
78 78 78
78
PM
78 78
78 78
78
Cooling (WEH) AM 78
78 78
78 78 78
78
78 78
78 78
78
PM 78
78 78
78 78 78
78
78 78
78 78
78
Heating (WD) AM 66
66 66
66 66 68
68
68 68
68 68
68
PM 68
68 68
68 68 68
68
68 68
68 66
66
Heating (WEH) AM 66
66 66
66 66 68
68
68 68
68 68
68
PM 68
68 68
68 68 68
68
68 68
68 66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 lbs/sq.ft.
0 ft2
0 ft
0.3
BEDROOM
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8 lbs/sq.fL
ft2
ft
0.3
M. BATH
Default(8 lbs/sq.fL
ft2
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
ft
0.3
BATH
Default(8 lbs/sq.fL
ft2
ft
0.3
BEDROOM 2
Default(8lbs/sq.fL
ft2
ft
0.3
ENTRY
Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
MASS
• Mass Type Area Thickness Furniture Fraction Space
Default a lbs/s -.ft. ft2 it 0.3 GREAT/DINING
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner. Jurisdiction:
w
Design Location: FL, Fort Pierce
c=i
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable Insulation shall
requirements
The exterior thermal envelope contains a. continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an dropped ceiling/soffit
y
the insulation and an
any in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be Insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope Insulation for framed
walls shall be Installed In substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall beinstalled ,to
(including
insulation.
.maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous Insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, Insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures Installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt Insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind oinina and wirina.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electricallphone box or
The air barrier shall be installed behind electricalor communication
exterior wails
boxes or air -sealed boxes shall be Installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition. inspection of log walls shall be in accordance wrath the provisions of ICC-400.
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1753
d) Room unit(PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.058
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.285
14. Heating system: Capacity
34.8.
c) Area
7c.
151.4
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor.(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE'
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank- EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
19.0
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with ,the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code, compliant features.
Builder Signature: Date:
Address of New Home'1 \ a-e aft U\-%1 J'- City/FL Zip: FT. PIERCE, FL
1/8/2020 4:43:52 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1