HomeMy WebLinkAboutDesign pressure calcsNewSouth WINDOW SOLUTIONS 2526 Okeechobee Blvd, West Palm Beach, FL 33409 • 561-712-9000 • CRC 1330822 Property Information Building Information Owner: William & Virginia Gillespie Wind Zone: 170 MPH. Address: 1 Lake Vista Trl Exposure Category: C Port St Lucie. FL 34952 Minimum Building Dimension: 35 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location ��� Device Device Device Max Positive Max Negative Number Nu Zone Width 1m) Height (in) Elevation (ft) Pressure (psf) Pressure (psi 1 Int 29.50 61.75 7 37.2 -40.4 2 Int 2950 61.75 7 37.2 -40.4 3 Int 36 36.50 7 37.8 -41.0 4 Int 52 49.50 7 36.4 -39.6 5 Int 52 49.50 7 36.4 -39.6 Prepared in accordance with: ASCE 7-10. Chapter 30. Wind Loads - Componenu and Cladding. 6rh Edition t2017) Florida BWlding Code. Page I of I