HomeMy WebLinkAboutBuilding PermitAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE
Date
7IN
COUNTY
F L O R I D A
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578
Permit Number:
Building Permit
Commercial
lication
Residential X
PERMITTYPEWater Heater replacement
PROPOSED IMPROVEMENT LOCATION:
Address: 159 NE Estia Lane, Port St Lucie, FL 34983
Property Tax ID ##: 3419-540-0052-000-3 Lot No. 14
Site Plan Name: Block No. 44
Project Name:
DETAILED DESCRIPTION OF WORK:.
Supply and Install (1) new Rheem electric 40 gallon low boy water heater
I CONSTRUCTION INFORMATION: I
Additional work to be performed under this permit –check all that apply:
_Mechanical _ Gas Tank —Gas Piping —Shutters
Electric Plumbing Sprinklers _ Genei ator
Total Sq. Ft of Construction:
Cost of Construction: $ 1,098.00
Sq. Ft. of First FI
Utilities: _Sewer -
Windows/Doors
Roof Pitch
Septic Building Height:
OWNER/LESSEE:
CONTRACTOR:
NameJoseph and Ann Drzal
Name:John Jacobs
Company:John
Address:4701 Oleander
City: Fort Pierce
Zip Code: 3498
Phone N0772-8132-8334
E-Mailimiacobs4.70l@gmail.com
State or County
Address: 159 NE Estia Lane
Jacobs Construction Inc.
City: Port St Lucie State: _
Zip Code: 34983 Fax:
Phone No.
Ave.
State: FL
Fax: 772-466-6491
E -Mail:
Fill in fee simple Title Holder on next page ( if different
from the Owner listed above)
LicenseCFC1429607
If value of construction is $2540 or more, a RECORDED Notice of Commencement is
If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is requir
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
DESIGNER/ENGINEER: _ Not Applicable
Name:
MORTGAGE C
Name:
Address:
City:
Zip:
MPANY: _ Not Applicable
Address:
STAT F FLO
City: State:
Zip: Phone
State:
Phone:
FEE SIMPLE TITLE HOLDER: _ Not Applicable
Name:
BONDING COMPANY:
Name:
Address:.
City:
Zip:
Not Applicable
Address:
The forgoing instrument
City:
this if 'day of 120.1,0 by
Zip: Phone:
Phone:
q1-) n -0,ce 13S
OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a per it to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit
St. Lucie County makes no representation that is granting a permit will authorize the ermit holder to build the subject structure
which is in contlict with any applicable Home Owners Association rules, bylaws or ans covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie Count Amendments.
The following building permit applications are exempt from undergoing a full concurr ncy review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accesso uses to another non-residential use
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMME CEMENT MAY RESULT IN YOUR PAYING
TWICE FOR IMPRO'YEMENTS TO YOUR PROPERTY. A NOTICE OF CO MENCEMENT MUST BE RECORDED AND
POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU 1 END TO OBTAIN FINANCING, CONSULT
WITH YOUR ENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOT £E OF COMMENCEMENT."
Signa e of Owner L ssee/Contractor as Agent for Owner
el
Signat of Cant
actor Li ense Holder
STAu OF FLORID
STAT F FLO
ISA
� t'� � � Q -
COUNTY OF L a c
COUNTY OF
JT
The forgoing instrument was acknowledged before me
The forgoing instrument
was acknowledged before me
this if 'day of 120.1,0 by
this _15j�^day of
120 20,90 by
q1-) n -0,ce 13S
A �r r,
�.�� 6s'
Name of person making statement.
Name of person making
statement.
OR Produced Identification
Personally Known
OR Produced Identification
Personally Known�
Type of Identification
Type of Identification
`�
Produced
Produced
I �
(Signature of ary Public- State of FIt
te(aigt 1wre try
21V
Public- State of F orida) 0vI�q
J-"Notary
No. !
906aeo
ommfssion o.
1� N05
t6_`7�
O �, �` ��✓ (Seal ``°1Commission
) W�
2
0
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEA TURTLE
NIA ROVE
COUNTER
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
RE
DATE
RECEIVED
DATE
COMPLETED
Rev. 2/7/19
JOHN JACOBS CONS TR UCT�ON, INC.
4701 OLEANDER A
FT PIERCE, FL 349 2
Cell (772) 882-833
Fax= (772) 466-649
License* CBCo60421 / CF 1429607
PROPOSAL SUBMUI DTO•
WORK TO BE PBRFO ED AT:
NAME: Joe & Ann Drzal
ADDRESS: SAME
ADDRESS: 159 NE Estia Lane
CrrY/STATE: FL
CrrY/STATE: Port St Lucie, FL 34983
DATE OF PROPOSAL:
5/18/2020
PHONE: 772-878-041JL
F.11YAM: drzal9@aol.com
Bathroom Remodel
Proposal Revised
WATER HEATER:
• Demo and remove existing water heater
• Supply and install i new Rheem 40 gallon low boy
• Permit included
PAYMENT SCHEDULE:
10o % Due upon completion of contracted work
TOTAL....................................................................
Any alteration or deviation from
above specifications involving extra
cost will be executed only upon
written order and will become an
extra charge over and above the
estimate. All agreements
contingent upon accidents, weather,
or delays beyond our control.
Proposal good for (3o) days.
Customer agrees to
contract;
Accepted Date:
Page 1 of x
................$1,098.00
submitted John Jacobs
The new degree of comfnrt3
Professional Classics electric water heal
engineered for longer life -- resistored he
elements and premium grade anode rod
Efficiency
• .90 - .93 UEF
• Isolated tank design reduces
conductive heat loss
• Resistored copper upper element and
resistored Lifeguard- stainless steel
lower element to prolong anode rod
and tank life
Performance
• FHR: 45 - 67 gallons, based on gallon
capacity
• Recovery: 21 GPH at a 90° F rise
system Sentinel
(Available on selected models)
• Exclusive diagnostic system with
glowing LEDs that verify heating
element operation, LEDs pin point the
exact location of functioning or non-
functioning heating elements
Longer Life
• Premium grade anode rod provides
long-lasting tank protection
Features
- Electric junction box located above
heating elements for easy installation
• Over -temperature protector cuts
of power in excess temperature
situations
• Automatic thermostat keeps water at
desired temperature
Plus,..
• Rheemgla.0 tank lining resists
corrosion and prolongs tank life
• EverMeen- self cleaning device fi
harmful sediment build-up with a
high -velocity spiraling water strew
helps operating efficiency by cavi
energy, money and improving tar
• Enhanced -flow brass drain valve
• Temperature and pressure relief
included
• HUD certified for manufactured
housing and modular constructic
• Low lead compliant
Warranty
•
r --year limited tank and parts
warranty'
+ With ProtectionPlus- the 6 -year'
tank warranty becomes 1 0 -Year
-See Residential warranty Certificate far CO'
information
units meet or exceed ANSI requirements ar
been tested according to the AHRI operatic
i4anuai and D.O.E. procedures. units meet
exceed the energy efficiency requirements c
NAECA. ASHRAI! standard go. ICC.Cade 2
state energy efficiency performance criteria
are
Residential Electric
M, Water Professional Classic Water Heaters
Professional Classic
iste 19.9 to 55 -Gallon Capacities
have 240 Volt AC/Single Phase
Double and Single Element Models
Electric
tat+
See spec'if'ications chart on back.
pta TM W u3A GsnE%WP FORM NO, PROE RN N Ri
fi
Tho new degree of comRxt
professional Classic' Specifications
FFATURES
nvu a
DESCRIPTION
HPATER CONN.
UEF
T ST HOUR RECOVERY
y NOMINAL AMID RATING IN GPJi
TANK
Hl]Gltr
ODEL
v GALLON GALLON HWHER Gplt. WVRtSE
0APACIrY CAPACFff
A
E
call 30 27 PROE30T2RHW 46 21
21
a7-112
60.31'4
5r�
Tail 40 36 PROE40T2 RH95$
92
PHOE50 T2 RH95t 63 21
Tall 50 4S P1
'37
_
r55 PFlOE55 T2 RF194' 72
Tall 55_ 21
37-172
Med. 30 27 ,PRO53➢ n42 RH95r 0.5
2t
48414
PRoE40 M2 RH95' 65
Med. d0 36 21
`IB
Med. 59 45 PROE50 M2 RH95t 62
21
31- 1/2
PROEN S2 RH -
Short 19.9 - A5 21
3o
Short 28 2S PRflE2952RH95
46 21
30-1/8
Short 30 27 PROM 52 RH95 9"
21
91-112
Short 3G 33 PROE36 S2 RH95 4B
21
31-1/2
Short 33 35 PROE38 S2 RH95 r3" 51
21
17
Short 47 43 PROE47 S2 RH95 54
31-1/9
orgy Factor and rated gallont:apacUY based on OePartment Of Energy [1 4 i° lu6�rr-'nts.
Sentlnal not available
an single
4inifonn
t spurn 5erdinel aptionaL Add MI to the end at the Madel num4er. System
onty- System seminPl rrot ausllable ht exce`� of 6 kW on
element madokh avaltetete on dual etemant mv[tels
95
208 V models. p1y�aliOtt blanket that is irtcktdad atlh water heater
VM. ivFA1Pl dznalsians 1 to erstaltrt9
*419' � 4500 watt Up
and
vidb standard 240 volt AC. single phi norjrSk IWMLtS
32-5/8
• Heaters furnished
Elements. demanded 67r mne requirements.111eY must he
• if heating elements of diltevent wattag ttrart tht�e shown are
34
specifically requested. . max ). SubsliWte"t' for'T in Croda n
• Single element modets avalJ ble On speCW order {
avalable. COnGJt feCtary for price
and amlalefty
. Special LNlri)g Options- A Lm ted n=bef of Speed "+Q"'9 options ace
• AR made13 Ospped Wth heat traps-
very ry= watiage/2.42 x temp. rise `F
Fxarnpie: 4500W = 21 GPH
272 x 90•
Reeovery t gc dat4m used are based an d500 watt darnenls used m non, sat is Son.
to keeping
with its policy of conitnuous progress and product improyetoent Rhe—
Rheem Water Heating o 1115 Northmeadow
Roswell, Georgia 30076 • www.rh
Residential Electric
Water I Professional Cfassfc Water Heaters
61N DIMENSIONS ISHOW f i 1, M INCHES]
1HlrittrTo
ONrdEi73i
APPN➢O L
HPATER CONN.
�..
6
50-318
19-114
92
53-518
19-114
149
61.518
20-1/4
121
59-3/4
22-1/4
128
40-1/2
20-1/4
92
50-1/2
20-114
106
50-112
23
132
31-1/2
17
62
31-1/9
23
95
32
19.3/4
95
3„
24-1/4
118
32-5/8
23
1.08
34
26-1/4
i49
HOT
REL1EE VALVE
CONNECTION
_RGY INFO.
UNIFORM
ENERGY
FAGTOR
0.92
0.93
0.93
0.92
0.20
0.93
0.93
0.92
0.92
0.92
0.92
0.93
•GOLD
WATEE
-..
WATER CONNECTIONS ALL 314" N.P.T.
s the right to make changes without dolt's.
Suite 100
PRINTED IN O.SA 95118wP FORM HO. PROF RH N Ret.