HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: WYNNE THE GRAND CARLTON IMPACT
BuilderName: WYNNE BUILDING COPR.
Street: \i, ����
PermitOfflce: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
PennitNumber:
Owner: WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
DesignLocation: FL, Fort Pierce
County. St Lucia (Florida Climate Zone 2)
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sqft.)
Insulation Area '
2. Single family ormultiple family Single-family
a. Concrete Block- Int lnsul, Exterior
R=4.1 1250.00ft-
3. Numberof units, ifmultiplefamily 1
b. Frame - Wood, Adjacent
c. N/A
R=11.0 192.00ft-
R= ft'
4. Number of Bedrooms 2
d•N/A
R= ft'
5. Is this a worst case? Yes
10.Ceiling Types (1476.0 sgfL)
Insulation Area
a. UnderAttic(Vented)
R=30.0 1446.00ft-
6. Conditioned floorarea above grade 1446
b. Knee Wall (Vented)
R=19.0 30.00112
Conditioned floorarea belowgrade(ft'J 0
c. N/A
R= ft
11. Duds
R ft'
7. Wmdows(141.3 sgft) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U-Factor: Sgl, U=1.04 101.25 ft'
SHGC: SHGC=029
b. U-Factor SgI,U=1.11 40.00 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor. WA ft'
SHGC:
13. Heating systems
k8tu/hr Efficiency
d. U-Factor. N/A ft'
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted AverageOverhang Depth: 3.832 ft.
Area WeighledAverage SHGC: 0.284
14. Hotwater systems
8. Floor Types (1445.5 sgft) Insulation Area
a. Electric
Cap:40gallons
a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft'
b. Conservation features
EF: 0.970
b. N/A R= ft-
None
c. NIA R= ft'
15. Credits
Pstat
Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.50
PASS
Total Baseline
Loads: 48.09
I hereby certify that the plans and specifications covered by
Review of the plans and
. &VESTS -
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
y`d r71
with the Florida Energy Code.
f. a r•. =3�° �O
PREPARED BY: __��� '�Z
Before construction is completed
DATE: 1-9-20
this building will be inspected for
compliance with Section 553.908
* c
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
lyGonWF.
with the Florida Energy Code.
OWNER/�G T
BUILDING OFFICIAL:
DATE: \\��� 7 o
DATE:
- Compliance requires certification by the air handler unit manufacturer tb;t hJaLhh r a clos re s1{is
certified factory -sealed' in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage. no greater than 7.00 ACH50 (R402.4.1.2).
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
118/20204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Softoo C C Pagel of
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE GRAND CARLT Bedrooms: 2
Address Type:
StreetAddrsss
BuildingType: User ConditidnedArea: 1446
Lot#
OwnerName: WYNNE BUILDING CROP TotalStodes: 1
Block/Subdivislon:
#of Units: 1 Worst Case: Yes
PlatBook:
BullderName: WYNNE BUILDING COPR. RotateAngle: 180
Street.
Permit Office: ST. LUCIE COUNTY CrossVentilation: No
County.
St. Lucie
Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No
City, State,Zip:
Fr. PIERCE,
FamilyType: Single-family
FL,
New/Edsting: New(From Plans)
Comment:
CLIMATE
/ Design Temp
IntDesignTemp Heating
Design DailyTemp
V DesignLocaUon TMY Site 97.5% 2.5%
Winter
Summer Degree Days Moisture
Range
FL, Fort Pieroe FL_VERO_BEACH MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 EntireHouse 1446 11568
SPACES
' Number Name Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM 301 2408 No 0
1
1 Yes
Yes
Yes
2 WIC 63 504 No 0
1 No
Yes
Yes
3 M.BATH 56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN 192 1536 Yes 0
1 No
Yes
Yes
5 BATH 45 360 No 0
1 Yes
Yes
Yes
6 BEDROOM 2 204 1632 No 0
1
1 Yes
Yes
Yes
7 ENTRY 55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY 42 336 No 0
1 Yes
Yes
Yes
9 GREATIDINING 488 3904 No 0
1 Yes
Yes
Yes
FLOORS
# FloorType Space . Perimeter PedmeterR-Value
Area
JoistR-Value
Ttle Wood
Carpet
1 Slab-On-GradeEdgelnsulation BEDROOM 5211 0
301 ft2
___
0 1 .
-0
2 Slab -On -Grade Edge Insulation WIC 1ft 0
63 ft2
___
0 1
0.
3 Slab-On-GradeEdgelnsulation M.BATH 8ft 0
56 ft2
0 1
0
4 Slab-On-GradeEdge Insulation KITCHEN 111 0
192 ft'
. ___
0 1
0
5 Slab -On -Grade Edgelnsulation BATH 5ft 0
45 ft2
0 1
0
6 Slab -On -Grade Edgelnsulation BEDROOM 32.2ft 0
203.5 ft2
___
0 1
0
7 Slab-On-GradeEdgelnsula6on ENTRY 7ft 0
55 ft2
___
0 1
0
1/8/20204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition.(2017) Compliant Software Page 2of5
FORM R405-2017 INPUT 5UMMAKY.GFIEGKLIST REPORT
FLOORS
# FloorType Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile
Wood Carpet,
8SIab-On-GradeEdgelnsulation LAUNDRY Eft
0
42 ft2
----
0
1
0
9 Slab-On-GradeEdgelnsulation GREAT/DINING 46ft 0
488 112
----
0
1
0
ROOF
Roof
Gable
Roof
Red
Solar
SA Emitt
Emift Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 GableorShed Metal 1524 ft2
240 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V
# Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Fullattic Vented
150
1446ft'
N
N
CEILING
# CeilingType Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 UnderAtOc(Vented) BEDROOM
30
Blown
301 IF
0.1
Wood
_ 2 UnderAttic(Vented) WIC
30
Blown
63ft2
.1
Wood
3 UnderAttic(Vented) M. BATH
30
Blown
56 R2
0.1
Wood
_ 4 UnderAttic(Vented) KITCHEN
30
Blown
192 112
0.1
Wood
5 UnderAttic(Vented) BATH
30
Blown
45 R2
0.1
Wood
6 UnderAttic(Vented) BEDROOM
30
Blown
204 ft2
0.1
Wood
7 UnderAtOc(Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
_ 8 UnderAttic(Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
_ 9 UnderAttic(Vented) GREATIDINING
30
Blown
488 ft'
0.1
Wood
10 KneeWall(Vented) GREATIDINING
19
Blown
30ft'
.11
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar
Below
0
_ 1 NE=>SW Exterior Concrete Block- Int lnsul BEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
2 SW=>NE Exterior Concrete Block- Int lnsul BEDROOM
4.1 2a
0 8
0
224.0 fV
0
0
0.4
0
_ 3 NW=>SE Exterior Concrete Block - Int lnsulBEDROOM
4.1 14
0 8
0
112.012
0
0
0.4
0
4 SW=>NE Exterior Concrete Block-Int lnsul M.BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
_ 5 NE=>SW Exterior Concrete Block-Int lnsul BATH
4.1 5
0 8
0
40.0ft
0
0
0.4
0
6 NE=>SW Exterior Concrete Block- Int lnsuBEDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.4
0
7 SE=>NW Exterior Concrete Block- Int lnsuBEDROOM 2
4.1 10
0 8
Or
80.0f2
0
0
0.4
0
8 S=>N Exterior Concrete Block- Int lnsuBEDROOM 2
4.1 4
3 8
0
34.0ft2
0
0.4
0
9 SW=>NE Exterior Concrete Block- Int lnsuBEDROOM 2
4.1 2
0 8
0
16.0ft'
0
0
0.4
0
10 SE=>NW Exterior Concrete Block-Intlnsul ENTRY
4.1 6
0 8
0
48.0 ft'
0
0
0.4
0
11 SW=>NE Exterior Concrete Block- Int lnsul ENTRY
4.1 1
0 8
0
8.0 ft'
0
0
DA
0
12 SW=>NE Exterior Concrete Block- Int lnsul LAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
13 NE=>SW Exterior Concrete Block- Int lnsul3REATIOINI
4.1 26
0 8
0
208.0 ft2
0
0
0.4
0
14 NW=>SE Exterior Concrete Block- Int lnsuGREAT/DINI
4.1 20
0 8.
0
160.0 ft'
0
0
0.4
0
1/8/2020 4:18 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRea2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
'FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
_15 N=>S Garage Frame -Wood
Space Cavity Width
KITCHEN 11 24 8
Height Sheathing Framing Solar Below
0
192.0 ft2 0.23 0.4 0
DOORS
# Omt
DoorType
Space Storms
U-Value Width
Ft In
- Height
Ft In
Area
1 SE=>NW
Insulated
ENTRY None
.39 3 1
6 8
20.6 ft'
WINDOWS
Orientation shown is the entered orientation => chari ed to Worst Case.
/ Wall
V # Omt ID Frame
Panes
NFRC U-Factor SHGC Imp
Overhang
Area Depth Separation
IntShade
Screening
1 NW=>SE 3 Metal
_ 2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW 13 Metal
5 NW=>SE14 Metal
Low-ESingle
Low-ESingle
Low-ESingle
Low-ESingle
Low-ESingle
Yes 1.04 0.29 Y
Yes 1.04 029 Y
Yes 1.04 0.29 Y
Yes 1.04 0.29 Y
Yes 1.11 0.27 Y
32.9 ft' 1 R 0In 1 ft 5 In
6.9 ft' 1 It 0 in 1 It 5 in
24.0 ft2 6 ft 0 in 1 it 5 in
37.5 ft' 1 It 0 in 1 ft 5 in
40.0 ft2 8 ft 0 in 1 ft 5 in
Drapes/blinds
None
None
None
Drapes/blinds
Exteriors
None
None
None
Extedor5
GARAGE,
# FloorArea
CeilingArea ExposedWallPerimetet
Avg.WallHeight ExposedWalllnsulation
1 315 ft'
315 ft2 24ft
8ft
11
INFILTRATION
# Scope Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Whclehouse ProposedACH(50)
.000356 1349.6 74.09 139.34 .1233
7
77�#
HEATING SYSTEM
System Type
Subtype Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split Single HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1 CentralUnitt
Split Single SEER:15
34.8 kBtulhr Cfm
0.8 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location EF Cap
Use SelPnt
Conservation
1 Electric
None
Garage 0.97 40gal 60.9gal 120deg
None
1/8/20204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page of
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart# CompanyName
System
Model#
CollectorModel#
Area Volume
FEF
None None
ft'
DUCTS
—Supply--
V
—Return—
Air
CFM 25 CFM25
HVAC#
# Location R-Value Area
Location
Area
LeakageType
Handler
TOT OUT QN RLF
Heat Cool
1 Attic
6 175 ft
Attic
65 ft'
DefaultLeakage
Attic
(Default) c(Default) c
1 1
TEMPERATURES
Programabler[T�jhennostat:[ Y
Ceiling Fans:
Heat ng Jan Feb
Mar
Apr
Apr
May
MDec
Jun
[ ]
(X) Jul
�IXX]]
() Aug
[X]
[)Sep
[ j r0'0 NovrDO,
L 1
Venting IIII 1111 Jan [[[[ 1111 Feb
l J l l
X Mar
ay
l l Jun
I[[ l]) Jul
[[ ]) Aug
O
Sep lxl Oct [X]
Nov
[ ]Dec
ThermostatSchedule: HERS 2006 Reference
Hours
ScheduleType
1
2
3
4
5
6
7
8
9 10
11
12
Cooling(WD) AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling(WEH) AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating (wD)
FM
68
68
6B
68
68
68
68
68
68 68
66
66
Heating(WEH) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
FumitureFraction
Space
Default(8lbslsq.ft.
0 ft'
Off
0.3
BEDROOM
Default(8lbs/sq.fL
ft'
ft
0.3
WIC
Default(8lbs/sq.8.
ft'
ft
0.3
M. BATH
Default(8lbs/sq.ft.
ft'
ft
0.3
KITCHEN
Default(8lbs/sq.ft.
ft'
ft
0.3
BATH
Default(81bs/sq.ft.
ft'
ft
0.3
BEDROOM 2
Default(8 lbslsq.ft.
ft'
ft
0,3
ENTRY
Default(8lbslsq.ft.
ft'
ft
0.3
LAUNDRY
Default 8lbs/s .ft..
ft'
ft
0.3
GREAT/DINING
1/8/20204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5of5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE.402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR.
Sheet: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
w
Design Location: FL, Fort Pierce
=
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
Acontinuous air barrier shall be installed in the building envelope.
Air -permeable Insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks orjoints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed,
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be Installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be Installed to
(Including
Insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be In contact with the top side
floors)
of sheathing, or continuous insulation Installed on
the underside of floor framing and extends from the
bottomto the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts In narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures Installed in the building thermal envelope
Recessed light fixtures Installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
Installation readily conforms to available space shall
extend behind pining and w1ring.
Shower/tub
The air barrier Installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
ElectdcaVphone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be Installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
J
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voidsnrinkler cover plates and walls or ceilings
a. m avaiuvu, n,apcumn m .ug wdns shall be in accoroancewm the provisions or !CC-400.
1/8/2020 4:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6thEdition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL)• DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts,'locatioh & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2: Single-family "
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 2
13. Cooling system: Capacity
34.8
-
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5. Yes
b) Single package 'SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
.6. 12146
d) Room unit(PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 1.060
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.284,
c) Area 7c. 141.3
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) ft NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
14. Heating system: Capacity 34.8
a) Split;system heat pump HSPF 8.5
b) Single package heat pump HSPF
c) Electric resistance COP'
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.97
b) Gas fired; natural gas EF
c) Gas fired, LPG I EF
d) Solar system with tank EF
e) Dedicated heat pump with tank. EF_
f) Heat recovery unit HeatRec%o
g) Other
10131.
11.0
10132.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11 a.
30.0
b) Cross ventilation No
11b.
c) Whole house fan 'No
11c.
19.0
d) Multizone cooling credit
11d.
No
e) Multizone heating credit -
0 Programmable thermostat Yes
`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final Inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: - Date: \
Address of New.HomeeN�� ` \ d` City/FL Zip: FT. PIERCE, FL l �i
1/8/2020 4:19:34 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1