HomeMy WebLinkAboutEnergy Code-FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE STERLING IMPACT
Builder Name: WYNNE DEVELOPMENT
-, Street: THE STERLING
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FLPIERCFS, „ 5
Owner:
Permit Number:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie(Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1250.00 ft'
b. Frame - Wood, Adjacent
R=11.0 192.00 ft'
3. Number of units, if multiple family 1
c. NIA
R= ft2
4. Number of Bedrooms 2
d. NIA
R= ft2
5. Is this a worst case? Yes
10. Ceiling. Types (1504.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1474.00 ft2
6. Conditioned floor area above grade (ft2) 1474
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (ft2) 0
c. NIA
R= ft2
11. Ducts
R ft2
7. Windows(141.3 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U-Factor: Sgi, U=1.04 101.25 ft2
SHGC: SHGC=0.29
b. U-Factor: SgI, U=1.11 40.00 ft2
12. Cooling systems
kBlu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. NIA ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.284
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1473.5 sqft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft"
b. Conservation features
b. NIA R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 47.97
Glass/Floor Area: 0.096
PASS
Total Baseline Loads: 48.55
/'1�7
I hereby certify that the plans and specifications covered by
Review of the plans and
Tt1SSTq
this calculation are in compliance with the Florida Energy
specifications covered by this
04
_ p
Code.
calculation indicates compliance
Code.
y'� °44 =� 4 Aa+
�O
_ �n
with the Florida Energy
i
PREPARED BY: /I % c��Su`�GV
Before construction is completed
DATE: 1-9-20
this building will be inspected'for
compliance with Section 553.908
. c
hereby certify that this building, as designed, is in compliance
Florida Statutes.,
with the. Florida Energy Code.
t''Opy
OWNER/AGFjNT:
BUILDING OFFICIAL:
DATE: `\
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist ,lQa6cffth oJect requires an
envelope. leakage test report with envelope leakage no greater than 7.00 5 ( 02 2). mp
REVIEWED FOR
CODE
pCOc�IV11PLiA1pN� CE
1/8/2020 4:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6t5litionga(,E1. r.Clifipliaatl8ottrttaNTY Page 1 of 5
BOCC
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE STERLING IMP Bedrooms: 2
Address Type:.
Street Address
Building Type: User Conditioned Area: 1474
Lot#
Owner Name: Total Stories: 1
Block/SubdMsion:
#of Units: 1 Worst Case: Yes
PlatBook:
' Builder Name: WYNNE DEVELOPMENT Rotate Angle: 160
Street:
THE STERLING
• Permit Office: ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie
Jurisdiction: Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/ Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY Site 97.5 %
12.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
76 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1474 11792
-
SPACES
Number Name Area Volume Kitchen Occupants
-Bedrooms
Infil ID Finished Cooled
Healed
1 BEDROOM 329 2632 No
0
1
1 Yes
Yes
Yes
2 WIC 63 504 No
0
1 No
Yes
Yes
3 M.BATH 56 448 No
0
1- Yes
Yes
Yes
4 KITCHEN 192 1536 Yes
0
1 No
Yes
Yes
5 BATH 45 360 No
0
1 Yes
Yes
Yes
6 BEDROOM2 204 1632 No
0
1
1 Yes
Yes
Yes
7 ENTRY 55 440 No
0
1 Yes
Yes
Yes
8 LAUNDRY 42 336 No
0
1 Yes
Yes
Yes
9 GREAT/DINING 488 3904 No
0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0
329 ft'
0 1
0
2 Slab -On -Grade Edge Insulatio WIC 1 ft 0
63 ft'
—
0 1
0
3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0
56 ft'
_
0 1
0
4 Slab -On -Grade Edge Insulatio KITCHEN t ft 0
192 ft'
_
0 1
0
5 Slab -On -Grade Edge. Insulatio BATH 5 ft 0
45 ft'
_
0 1
0.
6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0
203.5 ft'
_
0 1
0
7Slab-On-Grade Edge Insulatio ENTRY 7 ft 0
55 ft'
0 1
0
1/8/2020 4:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
8Slab-On-Grade Edgeinsulatio LAUNDRY E ft 0 42'ft2 ____ 0 1 0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 H' - 0 1 0
ROOF
Roof Gable
Roof
Red Solar SA .Emitt ' Emitt
Deck Pitch
V # Type Materials Area Area
Color
Barr Absor. Tested 'Tested
Insul. (deg)
1 Gable or Shed Metal 1553 ft2 246 ft2
Light
N 0.6 No 0.9 No
0 18.4
V # Type
1 Full attic
# Ceiling Type
1 Under Attic (Vented)
2 Under Attic (Vented)
3 Under Attic(Vented)
4 Under Attic (Vented)
5 Under Attic (Vented)
6 Under Attic (Vented)
7 Under Attic (Vented)
8. Under Attic (Vented)
9. Under Attic (Vented)
10 Knee Wall (Vented)
Bata[
Ventilation,
Vent Ratio (1 in)
Vented
150
CEILING
Space
R-Value
BEDROOM
30
WIC
30
M.BATH
30 ,
KITCHEN
30
BATH
30
BEDROOM 2
30
ENTRY
30
LAUNDRY
30
GREAT/DINING
30
BEDROOM
19
WALLS
Area
1474 ft2
Ins Ty{
Blown
Blown
Blown
Blown
Blown
Blown
Blown
Blown
Blown
Blown
FIBS
N
Area
329 W
63ft'
56 112
192 ft2
45 ft2
204 ft2
55,ft'
42 ft'
488 ft2
30 ft2
IRCC
N
ning Frac
Truss Tyl
0.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood,
0.1
Wood
0.11
Wood
Adjacent
Space
Cavity
Width
Height
Sheathing Framing
Solar
Below
_ 1 NE=>SW Exterior
Concrete Block -Inl lnstEEDROOM
4.1
10
0 8
0
80.0 ft2
0
0
0.4
0
-2 SW=>NE Exterior
Concrete Block - Int InsuBEDROOM
4.1
28
0 8
0
224.0 ft'
0
0
0.4
0
_ 3 NW=>SE Exterior
Concrete Block - Int InsuBEDROOM
4.1
14
0 8
0
112.0 ft2
0
0
0.4
0
-4 SW=>NE Exterior
Concrete Block - Int Insul M. BATH
4.1
8
0 8
0
64.0 ft2
0
0
0.4
0
-5 NE=>SW Exterior
Concrete Block - Int Insul BATH
4.1
5
0 8
0
40.0 ft'
0
-0
0.4
0
-6 NE=>SW Exterior.
Concrete Block- Int InsEIEDROOM 2
4.1
16
0 8
0
128.0 ft2
0
0
0.4
0
_ 7 SE=>NW Exterior
Concrete Block - Int InsGEDROOM 2
4.1
10
0 8
0
80.0 ft2
0
0
0.4
0
_ 8 S=>N Exterior
Concrete Block - Int InsBEDROOM 2
4.1
4
3 8
0
34.0 ft2
0
0
0.4
0
_ 9 SW=>NE Exterior
Concrete Block - Int InsEIEDROOM 2
4.1
2
0 8
0
16.0 ft2
0
0
0.4
0
_ 10 SE=>NW Exterior
Concrete Block- Int Insul ENTRY
4.1
6
0 8
0
48.0 ft'
0
0
0.4
0
_ 11 SW=>NE Exterior
Concrete Block- Int Insul ENTRY
4.1
1
0 8
0
8.0 ft2
0
0
0.4
0
_ 12 SW=>NE Exterior
Concrete Block - Int InsuLAUNDRY
4.1
6
0 8
0
48.0 112
0
0
0.4
0
_ 13 NE=>SW Exterior
Concrete Block - Int InstOREATIDINI
4.1
26
0 8
0
208.0 ft2
0
0
0.4
0
_14 NW=>SE Exterior
Concrete Block- Int InstBREAT/DINI
4.1
20
0 8
0
160.0 ft2
0
0
0.4
0
1/8I2020 4:48 PM EnergyGauge® USA 6.0.02,(Rev. 1) - FlaRes2017FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space Cavity Width Height Sheathing Framing Solar Below
15 N=>S Garage Frame - Wood
KITCHEN 11 24 8 192.0 ft2 0.23 0.4
0
DOORS
# Omt
Door Type
Space
Storms U-Value Width Height
Ft In Ft In
Area
1 SE=>NW
Insulated
ENTRY
None .39 3 1 6 8
20.6ft2
WINDOWS
Orientation shown is the entered. orientation => changed to Worst Case.
Wall
# Ornt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
_ 1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
_ 3 SE=>NW 7 Metal
4 NE=>SW13 Metal
5 NW=>SE14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
1.04 0.29 N 32.9 ft2 1 It 0 in 1 ft 5 in. Drapeslblinds
1.04 0.29 N 6.9 ft2. 1 It 0 in 1 It 5 in None
1.04 0.29 N 24.0 ft2 6 ft 0 in 1 ft 5. in None
1.04 0.29 N 37.5.ft2 1 It 0 in 1 It 5 in. None
1.11 0.27 N 40.0 112 8 ft 0 in 1 It 5 in Drapesiblinds •.
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315 ft2
315 ft2
24ft 8ft 11
INFILTRATION'
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1375.7 75.53 142.04 .1233 7
HEATING SYSTEM
# .System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1 Electric. Heat Pump/
Split
Singl HSPF:8.5 34.8 kBtulhr 1
. sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 34.8 kBtulhr cfm 0.85 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use SelPnt Conservation
1 Electric
None
Garage
0.97 40 gal 60.9 gal 120 deg None
1/812020 4:48 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4. of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model
#
Area Volume
FEF
None None
ft2
DUCTS
/ — Supply —
—
Return —
Air
CFM 25 CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT OUT ON
RLF
Heat Cool
1 Attic
6 175 ft2
Attic
65 ft2
Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programabl(e Thermostart:'jY
Cfreiling Fans:
Heating [X] Jan Feb
((��
pq Mar
�
� Aov
I May
f
rl JuMay n rj Jul
[X]
(] Aug
[X]
[)
[ ] (r)(')
Sep L.l Oct
Dec
Venting [[ 11 Jan [ 1 Feb
l l
[[�X]] Mar
pr
[
Jun C Jul
[ ] Aug
[ ]
Sep lXl [X]
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
78
78
78 78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78 78
78
78
78 78
78
78
PM
78
78
78
78
78 78
78
78
78 78
78
78
Heating (WD) AM
66
66
66
66
66 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66
66 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 lbs/sq.ft.
0 ft2
0 ft
0.3
BEDROOM
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8 lbs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
ft
0.3.
BATH
Default(B lbs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Defauit(8 lbs/sq.ft.
ft2
ft
0.3
ENTRY
Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 lbs/s.ft.
ft2
ft
0.3
GREAT/DINING
1/8/2020 4:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT
Street: THESTERLING Permit Office: ST.LUCIE000NTY
City, State, Zip: FT. PIERCE, FL, Permit Number.
-Yi
Owner: Jurisdiction:
_
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barter shall be sealed.
Ceilinglattic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the topplate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the lop of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor Insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readity, conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed fighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or Insulation that on
installation readily conforms to available space shall
extend behind ninino and Wrina.
Shower/tub
The air barrier installed at exterior walls. adjacent to showers and
Exterior walls. adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
I
Caulking or other adhesive sealants shall not be used to fill voids
between fire snrinkler cover Mates and walls or cemlinag I
a. In aadaion, Inspection or log wails snail tie in accordance with the provisions of ]CC-400.
1/8/2020 4:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1474
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.060
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.284
14. Heating system: Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump HSPF
8.5
b)Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1061.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
by Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
19.0
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed ode compliant features. '� l
Builder Signature: �- Date:
Address of New Home: THE STERLING 55�� 5 City/FL Zip: FT. PIERCE, FL � �'1.4
1/8/2020 4:49:01 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1