FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjeclName: WYNNE THE ^GRA`ND_CARLTON IMPACT
Street?j� �"�q
BuilderName: WYNNE BUILDING COPR.
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
PennitNumber:
Owner: WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
Designt-ocation: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)-
9. Wall Types (1442.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- Int lnsul, Exterior
R=4.1 1250.00 ft2
3. Number of units, if multiple family 1
b. Frame -Wood, Adjacent
c. WA
R=11.0 192.00 ft'
R= ft2
4. Number of Bedrooms 2
d.N/A
R= ft'
5. is this a worst case? Yes
10.Ceiling Types (1476.0 sgft.)
Insulation Area
a. UnderAttic(Vented)
R=30.0 1446.00ft'
6. Conditioned floorarea above grade (ft2) 1446
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floorarea belowgrade(ftl 0
c. NIA
R= ft2
7. Windows (141.3 sgft) Description Area
11. Ducts
a. Sup: Attic, Rat: Attic, AH: Attic
R ft2
6 175
a. U-Factor: Sgl,U=1.04 101.25ft'
SHGC: SHGC=0.29
b. U-Factor: Sgl,U=1.11 40.00 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=027
a. Central Unit
34.8 SEER:15.00
c. U-Factor. N/A ft2
SHGC:
d. U-Factor: WA ft.
13. Heating systems
kBtu/hr Efficiency
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
AreaWeighledAverageOverhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.284
14. Hotwater systems
8. Floor Types (1445.5 sgft) Insulation Area
a. Electric
Cap:40gallons
a. Slab -On -Grade Edgelnsulation R=0.0 1445.50ft'
b. Conservation features
EF: 0.970
b. N/A R= ft'
None
c. N/A R= ft'
15.Credits
Pstat
Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.50
PASS
Total Baseline Loads: 48.09
I hereby certify that the plans and specifications covered by
this
Review of the plans and
S srq�
calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
r /, ' _= $ .n
with the Florida Energy Code.
{O
PREPARED BY:Q
Before construction is Completed
DATE: 1-9-2D
this building will be inspected for
t`
compliance with Section 553.908
' r
hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the FloridaPEnergy Code.
w
BUILDING OFFICIAL:
DATE:OWNE
\ \
DATE:
- Compliance requires certification by the air handler unit manufacturg t t he ahCerOld L tes as
certified factorysealed in accordance with R403.3.2.1. t T- Compliance requires an Air Barrier and Insulation Inspection Checklist in actor ante v..1 ana this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
REVIEWED FOR
CODE COMPLIANCE
T LUCIE COUNTY
1/8/20204:18 PM EnergyGauge®USA 6.0.02(Rev. 1)- FlaRes2017 FBC 6th E on(81017) CoM,6oftware Page of
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE GRAND CARLT Bedrooms: 2
Address Type:
StreetAddress
Building Type: User ConditionedArea: 1446
Lot#
OwnerName: WYNNE BUILDING CROP TotalStories: 1
Block/Subdivlsion:
#of Units: 1 Worst Case: Yes
PlatBook:
BuiiderName: WYNNE BUILDING COPR. RotateAngle: 180
Street:
Permit Office: ST. LUCIE COUNTY CrossVen9latiorr.. No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No
City, State, Zip:
FT. PIERCE,
FamilyType: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/ Design Temp
Int Design Temp Heating
Design DailyTemp
V DeslgnLocation TMYSite 97.5% 2.5%
Winter
Summer Degree Days Moisture
Range
FL, Fart Pierce FL VERO BEACH_MUNI 39 90
70
75 299
62 1
Law
BLOCKS
Number Name Area Volume
1 EntireHouse 1446 11568
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM 301 2408 No 0
1
1 Yes
Yes
Yes
2 WIC 63 504 No 0
1 No
Yes
Yes
3 M.BATH 56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN 192 1536 Yes 0
1 No
Yes
Yes
5 BATH 45 366 No 0
1 Yes
Yes
-Yes
6 BEDROOM 2 204 1632 No 0
1
1 Yes
'Yes
Yes
7 ENTRY 55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY 42 336 No 0
1 Yes
Yes
Yes
9 GREAT/DINING 488 3904 No 0
1 Yes
Yes
Yes
FLOORS
# FloorType Space Perimeter PerimeterR-Value
Area
JaistR-Value
Tile Wood
Carpet
1 Slab-On-GradeEdgelnsulation BEDROOM 62ft. .0
301 ft2
__--
0 1.
.0
2 Slab-On-GradeEdge Insulation WIC 1ft 0
63ft2
0 1
0
3 Slab-On-GradeEdge Insulation M. BATH aft 0
56 ft2
____
01 1
0
4 Slab-On-GradeEdgelnsulation KITCHEN 1 ft 0
192ft2
___
0 1
0
5 Slab-On-GradeEdgelnsulation BATH 5ft 0
45 ft2
__-_
0 1
0
6 Slab-On-GradeEdgelnsulation BEDROOM2 322ft 0
203.5 ft2
____
0. 1
0
7 Slab-On-GradeEdge Insulation ENTRY 7ft 0
55 112
____
0 1
0.
1/8/20204:18 PM EnergyGauge®USA 0.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software . Page of
FORM R405-2017 INPUT SUMMARY. CHECKLIST REPORT
FLOORS
# FloorType Space Perimeter PerimeterR-Value
Area
Joist R-Value
Tile Wood Carpet
8SIab-On-GradeEdgetnsulation LAUNDRY 6ft 0
42 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulation GREAT/DINING 46ft 0
488 ft2
----
0
1
0
ROOF
/ Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested lesul.
(deg)
1 GableorShed Metal 1524 ft2
240ft
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V
# Type Ventilation
Vent Ratio (1 In)
Area
FIBS
IRCC
1 Full attic Vented
150
1446ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 UnderAttic(Vented) BEDROOM
30
Blown
301 ft2
0.1
Wood
_ 2 UnderAtgc(Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 UnderAttic(Vented) M.BATH
30
Blown
56 112
0.1
Wood
_ 4 UnderAtdc(Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 UnderAttic(Vented) BATH
30
Blown
45 f12
0.1
Wood
_ 6 UnderAtOc(Vented) BEDROOM
30
Blown
204 ft2
0.1
Wood
7 UnderAttic(Vented) ENTRY
30
Blown
55 fN
0.1
Wood
8 UnderAtfic(Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9- UnderAtOc(Vented) GREAT/DINING
30
Blown
488 IF
0.1
Wood
10 KneeWall(Vented) GREATIDINING
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar
Below
2
_ 1 NE=>SW Exterior Concrete Block- Int lnsul BEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
2 SW=>NE Exterior Concrete Block- Int lnsul BEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.4
0
3 NW=>SEExterior Concrete Block - Int lnsulBEDROOM
4.1 14
0 8
0
112.0ft2
0
0
0.4
0
_ 4 SW=>NE Exterior Concrete Block -Int lnsul M.BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
_ 5 NE=>SW Exterior Concrete BlockL Intlnsul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.4
0
_ 6 NE=>SW Exterior Concrete Block- Int lnsuBEDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.4
0
7 SE=>NW Exterior Concrete Block- Int lnsuBEDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
8 S=>N Exterior Concrete Block- Int lnsuBEDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.4
0
_ 9 SW=>NE Exterior Concrete Block- Int lnsuBEDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.4
0
10 SE=>NW Exterior Concrete Block- Intlnsul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
11 SW=>NE Exterior Concrete Block - Intlnsul ENTRY
4.1 1
0 8
0
8.0 IF
0
0
0.4
0
12 SW=>NE Exterior Concrete Block-Int lnsul LAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
13 NE=>SW Exterior Concrete Block- Int lnsuGREAT/DINI
4.1 26
0 8
0
208.0 fN
0
0
0.4
0
14 NW=>SE Exterior Concrete Block- Int lnsuGREAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.4
0
1/8/20204:18 PM EnergyGauge®USA 6.0.02(Rey.1)- FlaRe52017 FBC 6lh Edition(2017) Compliant Software Page 3of5
FORM R405-2017 INPUT SUMMARY CHFCKI 1ST RIPPART
WALLS
Adjacent
Space Cavity Width Height Sheathing Framing Solar Below
0
_15 N=>S Garage Frame -Wood
KITCHEN 11 24 8 192.0 ft' 0.23 0.4
0
DOORS
# Omt
DoorType
Space Storms U-Value Width Height
Ft In Ft In
Area
1 SE=>NW
Insulated
ENTRY None .39 3 1 6 8
20.6 ft'
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
_ / Wall
V # Oml ID Frame
Panes
Overhang
NFRC U-Factor SHGC Imp Area Depth Separation IntShade
Screening
1 NW=>SE 3 Metal
_ 2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW 13 Metal
5 NW=>SE14 Metal
Low-ESingle
Low-ESingle
Low-ESingle
Low-ESingle
Low-ESingle
Yes 1.04 0.29 Y 32.9 ft' 1 It 0 in 1 It 5 in Drapes/blinds
Yes 1.04 0.29 Y 6.9 ft' 1 ft 0 in 1 ft 5 in None
Yes 1.04 0.29 Y 24.0 ft' 6 110 in 1 ft 5 in None
Yes 1.04 0.29 Y 37.5 ft' 1 It 0 in 1 It 5 in None
Yes 1.11 0.27 Y 40.0 ft' 8 ft 0 in 1 It 5 in Drapestblinds
Fxdericr5
None
None
None
Exterior5
GARAGE
# FloorArea
Ceiling Area Exposed Wall Perimeter Avg. Wall Height ExposedWalllnsulation
1 316 ft'
315 ft. 24It 8ft 11
INFILTRATION
# Scope Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse ProposedACH(50) .000356
1349.6 74.09 139.34 .1233 7
HEATING SYSTEM
# System Type
Subtype Speed Efficiency Capacity Block
Ducts
1 Electric Heat Pump/
Split Single HSPF:8.5 34.8 kBtuthr 1
sys#1
COOLING SYSTEM
# System Type
Subtype Subtype Efficiency Capacity AirFlow SHR Block
Ducts
1 CenbalUnitl
Split Single SEER:15 34.8 kBtu/ltr cfm 0.8 1
Sys#1
HOT WATER SYSTEM
# System Type
SubType
Location EF Cap Use SetPnt Conservation
1 Electric
None
Garage 0.97 40ga1. 60.9 gal 120deg None
118/20204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4of5
FORM R405-2017 INPUT SUMMARY CHECKI IST RFPnRT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # CompanyName
SystemModel* CollectorModel# Area Volume
FEF
None None
ft2
DUCTS
_ / —Supply—
—Retum—
Air
CFM 25
CFM25
HVAC#
V # Location R-Value Area
Location
Area
LeakageType
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic
6 175 ft-
Attic
65 ft2
DefaultLeakage
Attic
(Default) c(Default) c
1 1
TEMPERATURES
ProgramablfeTh'' ennostat::r
CeilingFans:
],Y
Heating HJan fX1 Feb
[r ]'Apr
fX1 Mar
(Ejj
Jun
�0(1�
rr (r)(')
Dec
(D(��
Venting [[[ 771 Jan [[I( 1III Feb
[[[[���X111) Mar
[X]Apr
lxl
[
May
I Jun [ Jul
[ Aug
[ ]Sep
Oct [ ]X
Nov
[ ]Dec
ThermostatSchedule: HERS 2006 Reference
Hours
ScheduleType
1
2
3
4
5 6
7
8
9 10
11
12
Cooling(WD) AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
78
78
78 78
78
78
78 78
78
78
Cooling(WEH) AM
78
78
78
78
78 78
78
78
78 78
78
78
PM
78
78
78
78
78 78
78
78
78 78
78
78
Heating(WD) AM
66
66
66
66
66 68
68
68
68 68
68
68
PM
68
68
68
6B
68 68
68
68
68 68
66
66
Heating(WEH) AM
66
68
66
66
66 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness FumitureFraction
Space
Default(8lbs/sq.ft
0 ft2
Off
0.3
BEDROOM
Default(8lbs/sq.fL
ft2
ft
0.3
WIC
Default(8 lbs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8 lbs/sq.ft
ft2
ft
0.3
KITCHEN
Default(81bs/sq.ft.
ft2
ft
0.3
BATH
Defauit(8lbs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8lbs/sq.fL
ft2
ft
0.3
ENTRY
Default(81bs/sq.fL
ft2
ft
0.3
LAUNDRY
Default 8lbs/s .fL
ft2
ft
0.3
GREAT/DINING
1/8/20204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC Sth Edition(2017) Compliant Software Page 5of5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number.
Y
Owner. WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
w
Design Location: FL, Fort Pierce
x�
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
Aconfinuous air bander shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The Insulation in any dropped ceiling/soffit
the Insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of -the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors,
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(Including
insulation,
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvenled crawl spaces shall be covered with
Where provided instead of floor Insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawispace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in file building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind nininn and w1rina.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box o
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
prinkler cover plates and walls orcelfings.—
u aumuuu, luayculuu v, Ivy walla alldll uc In duculudrGe wlm me provisions or IOG4uu.
'I/8/2020 4:19 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system SEER °
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1446
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor.(weighted average)
7a.
1.060
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.284
14. Heating system: Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior.
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
110A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level a) Ceiling fans
a) Under attic 11 a. 30.0 b) Crass ventilation No
b) Single assembly 11b. c) Whole house fan No
c) Knee walls/skylight walls 11 c. 19.0 d) Multizone cooling credit
d) Radiant barrier installed 11d. No e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, If not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features. , ,
Builder Signature: Date:
Address of New Home: 2. - \ City/FL Zip: FT. PIERCE. FL
1/8/2020 4:19:34 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1