Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjeclName: WYNNE THE ^GRA`ND_CARLTON IMPACT Street?j� �"�q BuilderName: WYNNE BUILDING COPR. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, PennitNumber: Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Designt-ocation: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans)- 9. Wall Types (1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Int lnsul, Exterior R=4.1 1250.00 ft2 3. Number of units, if multiple family 1 b. Frame -Wood, Adjacent c. WA R=11.0 192.00 ft' R= ft2 4. Number of Bedrooms 2 d.N/A R= ft' 5. is this a worst case? Yes 10.Ceiling Types (1476.0 sgft.) Insulation Area a. UnderAttic(Vented) R=30.0 1446.00ft' 6. Conditioned floorarea above grade (ft2) 1446 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floorarea belowgrade(ftl 0 c. NIA R= ft2 7. Windows (141.3 sgft) Description Area 11. Ducts a. Sup: Attic, Rat: Attic, AH: Attic R ft2 6 175 a. U-Factor: Sgl,U=1.04 101.25ft' SHGC: SHGC=0.29 b. U-Factor: Sgl,U=1.11 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=027 a. Central Unit 34.8 SEER:15.00 c. U-Factor. N/A ft2 SHGC: d. U-Factor: WA ft. 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: AreaWeighledAverageOverhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.284 14. Hotwater systems 8. Floor Types (1445.5 sgft) Insulation Area a. Electric Cap:40gallons a. Slab -On -Grade Edgelnsulation R=0.0 1445.50ft' b. Conservation features EF: 0.970 b. N/A R= ft' None c. N/A R= ft' 15.Credits Pstat Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.50 PASS Total Baseline Loads: 48.09 I hereby certify that the plans and specifications covered by this Review of the plans and S srq� calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance r /, ' _= $ .n with the Florida Energy Code. {O PREPARED BY:Q Before construction is Completed DATE: 1-9-2D this building will be inspected for t` compliance with Section 553.908 ' r hereby certify that this building, as designed, is in compliance Florida Statutes. with the FloridaPEnergy Code. w BUILDING OFFICIAL: DATE:OWNE \ \ DATE: - Compliance requires certification by the air handler unit manufacturg t t he ahCerOld L tes as certified factorysealed in accordance with R403.3.2.1. t T- Compliance requires an Air Barrier and Insulation Inspection Checklist in actor ante v..1 ana this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). REVIEWED FOR CODE COMPLIANCE T LUCIE COUNTY 1/8/20204:18 PM EnergyGauge®USA 6.0.02(Rev. 1)- FlaRes2017 FBC 6th E on(81017) CoM,6oftware Page of FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE GRAND CARLT Bedrooms: 2 Address Type: StreetAddress Building Type: User ConditionedArea: 1446 Lot# OwnerName: WYNNE BUILDING CROP TotalStories: 1 Block/Subdivlsion: #of Units: 1 Worst Case: Yes PlatBook: BuiiderName: WYNNE BUILDING COPR. RotateAngle: 180 Street: Permit Office: ST. LUCIE COUNTY CrossVen9latiorr.. No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, FamilyType: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design DailyTemp V DeslgnLocation TMYSite 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fart Pierce FL VERO BEACH_MUNI 39 90 70 75 299 62 1 Law BLOCKS Number Name Area Volume 1 EntireHouse 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 366 No 0 1 Yes Yes -Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes 'Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area JaistR-Value Tile Wood Carpet 1 Slab-On-GradeEdgelnsulation BEDROOM 62ft. .0 301 ft2 __-- 0 1. .0 2 Slab-On-GradeEdge Insulation WIC 1ft 0 63ft2 0 1 0 3 Slab-On-GradeEdge Insulation M. BATH aft 0 56 ft2 ____ 01 1 0 4 Slab-On-GradeEdgelnsulation KITCHEN 1 ft 0 192ft2 ___ 0 1 0 5 Slab-On-GradeEdgelnsulation BATH 5ft 0 45 ft2 __-_ 0 1 0 6 Slab-On-GradeEdgelnsulation BEDROOM2 322ft 0 203.5 ft2 ____ 0. 1 0 7 Slab-On-GradeEdge Insulation ENTRY 7ft 0 55 112 ____ 0 1 0. 1/8/20204:18 PM EnergyGauge®USA 0.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software . Page of FORM R405-2017 INPUT SUMMARY. CHECKLIST REPORT FLOORS # FloorType Space Perimeter PerimeterR-Value Area Joist R-Value Tile Wood Carpet 8SIab-On-GradeEdgetnsulation LAUNDRY 6ft 0 42 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulation GREAT/DINING 46ft 0 488 ft2 ---- 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested lesul. (deg) 1 GableorShed Metal 1524 ft2 240ft Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 In) Area FIBS IRCC 1 Full attic Vented 150 1446ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 UnderAttic(Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood _ 2 UnderAtgc(Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 UnderAttic(Vented) M.BATH 30 Blown 56 112 0.1 Wood _ 4 UnderAtdc(Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 UnderAttic(Vented) BATH 30 Blown 45 f12 0.1 Wood _ 6 UnderAtOc(Vented) BEDROOM 30 Blown 204 ft2 0.1 Wood 7 UnderAttic(Vented) ENTRY 30 Blown 55 fN 0.1 Wood 8 UnderAtfic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9- UnderAtOc(Vented) GREAT/DINING 30 Blown 488 IF 0.1 Wood 10 KneeWall(Vented) GREATIDINING 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 2 _ 1 NE=>SW Exterior Concrete Block- Int lnsul BEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 2 SW=>NE Exterior Concrete Block- Int lnsul BEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.4 0 3 NW=>SEExterior Concrete Block - Int lnsulBEDROOM 4.1 14 0 8 0 112.0ft2 0 0 0.4 0 _ 4 SW=>NE Exterior Concrete Block -Int lnsul M.BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 _ 5 NE=>SW Exterior Concrete BlockL Intlnsul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 _ 6 NE=>SW Exterior Concrete Block- Int lnsuBEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 7 SE=>NW Exterior Concrete Block- Int lnsuBEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 8 S=>N Exterior Concrete Block- Int lnsuBEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0 _ 9 SW=>NE Exterior Concrete Block- Int lnsuBEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 10 SE=>NW Exterior Concrete Block- Intlnsul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 11 SW=>NE Exterior Concrete Block - Intlnsul ENTRY 4.1 1 0 8 0 8.0 IF 0 0 0.4 0 12 SW=>NE Exterior Concrete Block-Int lnsul LAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 13 NE=>SW Exterior Concrete Block- Int lnsuGREAT/DINI 4.1 26 0 8 0 208.0 fN 0 0 0.4 0 14 NW=>SE Exterior Concrete Block- Int lnsuGREAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 1/8/20204:18 PM EnergyGauge®USA 6.0.02(Rey.1)- FlaRe52017 FBC 6lh Edition(2017) Compliant Software Page 3of5 FORM R405-2017 INPUT SUMMARY CHFCKI 1ST RIPPART WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 _15 N=>S Garage Frame -Wood KITCHEN 11 24 8 192.0 ft' 0.23 0.4 0 DOORS # Omt DoorType Space Storms U-Value Width Height Ft In Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. _ / Wall V # Oml ID Frame Panes Overhang NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 NW=>SE 3 Metal _ 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Low-ESingle Low-ESingle Low-ESingle Low-ESingle Low-ESingle Yes 1.04 0.29 Y 32.9 ft' 1 It 0 in 1 It 5 in Drapes/blinds Yes 1.04 0.29 Y 6.9 ft' 1 ft 0 in 1 ft 5 in None Yes 1.04 0.29 Y 24.0 ft' 6 110 in 1 ft 5 in None Yes 1.04 0.29 Y 37.5 ft' 1 It 0 in 1 It 5 in None Yes 1.11 0.27 Y 40.0 ft' 8 ft 0 in 1 It 5 in Drapestblinds Fxdericr5 None None None Exterior5 GARAGE # FloorArea Ceiling Area Exposed Wall Perimeter Avg. Wall Height ExposedWalllnsulation 1 316 ft' 315 ft. 24It 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000356 1349.6 74.09 139.34 .1233 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Single HSPF:8.5 34.8 kBtuthr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity AirFlow SHR Block Ducts 1 CenbalUnitl Split Single SEER:15 34.8 kBtu/ltr cfm 0.8 1 Sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40ga1. 60.9 gal 120deg None 118/20204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4of5 FORM R405-2017 INPUT SUMMARY CHECKI IST RFPnRT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # CompanyName SystemModel* CollectorModel# Area Volume FEF None None ft2 DUCTS _ / —Supply— —Retum— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area LeakageType Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft- Attic 65 ft2 DefaultLeakage Attic (Default) c(Default) c 1 1 TEMPERATURES ProgramablfeTh'' ennostat::r CeilingFans: ],Y Heating HJan fX1 Feb [r ]'Apr fX1 Mar (Ejj Jun �0(1� rr (r)(') Dec (D(�� Venting [[[ 771 Jan [[I( 1III Feb [[[[���X111) Mar [X]Apr lxl [ May I Jun [ Jul [ Aug [ ]Sep Oct [ ]X Nov [ ]Dec ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 6B 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 68 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness FumitureFraction Space Default(8lbs/sq.ft 0 ft2 Off 0.3 BEDROOM Default(8lbs/sq.fL ft2 ft 0.3 WIC Default(8 lbs/sq.ft. ft2 ft 0.3 M. BATH Default(8 lbs/sq.ft ft2 ft 0.3 KITCHEN Default(81bs/sq.ft. ft2 ft 0.3 BATH Defauit(8lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8lbs/sq.fL ft2 ft 0.3 ENTRY Default(81bs/sq.fL ft2 ft 0.3 LAUNDRY Default 8lbs/s .fL ft2 ft 0.3 GREAT/DINING 1/8/20204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC Sth Edition(2017) Compliant Software Page 5of5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Y Owner. WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY w Design Location: FL, Fort Pierce x� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General Aconfinuous air bander shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The Insulation in any dropped ceiling/soffit the Insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of -the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors, The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (Including insulation, maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvenled crawl spaces shall be covered with Where provided instead of floor Insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in file building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind nininn and w1rina. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box o The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids prinkler cover plates and walls orcelfings.— u aumuuu, luayculuu v, Ivy walla alldll uc In duculudrGe wlm me provisions or IOG4uu. 'I/8/2020 4:19 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER ° 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1446 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor.(weighted average) 7a. 1.060 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.284 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior. d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 110A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Crass ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 c. 19.0 d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, If not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. , , Builder Signature: Date: Address of New Home: 2. - \ City/FL Zip: FT. PIERCE. FL 1/8/2020 4:19:34 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1