HomeMy WebLinkAboutCalcs, project informationProject Summary pate; F wrightsoft° Entire House By. QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL34946 P1nre: 772-46&6799 Email: QUICKCALCSQAOL.COM For: DOUGLASALLEE 2432 OAK DRIVE, FT. PIERCE, FL Notes: �...., ., De siananforrr>atlon:.` Calculations approved byACCA to meet all requirements of Manual J 8th Ed _ wrigttttsoft� 2020 -May -1509:03:22 •_-•_ _ Ng Safe®Uriversa1201919.0.07RSU06101 Pa9e1 ...CK1Ua.0 s\WngH.ftIWAC\ALLEE, DOUGLAS.np Calc=MJ6 Front Door faros: W Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 of Outside db 90 'F Inside db 70 of Inside db 75 °F Design TD 28 'F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 24883 Btuh Structure 23261 Btuh Ducts 6169 Btuh Ducts 8725 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 31052 Btuh Use manufacturer's data n Rate/swingg multiplier Equipmentload 0.95 30387 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2215 Btuh Ducts 2379 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(It2) 1691 1691 Equipment latent load 4594 Btuh Volume (ft) 15905 15905 AirchangesAiour 0.38 0.20 Equipment Total Load (Sen+Lat) 34981 Btuh Equiv. AVF (cfm) 101 53 Req. total capacity at 0.70 SHR 3.6 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade EXISTING Model Cond 14AJM42A01 AHRlref Coil RHLL-HM3821JA AHRI ref Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating Input 7.8 kW Sensible cooling 29050 Btuh Heating output 26550 Btuh Latent cooling 12450 Btuh Temperature rise 17 °F Total cooling 41500 Btuh Actual airflow 1383 cfm Actual airflow 1383 cfm Airflow factor 0.045 cfmBtuh Alrflowfactor 0.043 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.87 Calculations approved byACCA to meet all requirements of Manual J 8th Ed _ wrigttttsoft� 2020 -May -1509:03:22 •_-•_ _ Ng Safe®Uriversa1201919.0.07RSU06101 Pa9e1 ...CK1Ua.0 s\WngH.ftIWAC\ALLEE, DOUGLAS.np Calc=MJ6 Front Door faros: W dm svieno0'331-MOVAH Bas101 L5E0:60 S4-AMUM 4068 MJ LO'0'6L 6 602 Imomun omirlsigkl abed Z8 6 aleos woo iov@soivoAolno 66L9-996-ZLL :auoyd 9667£l3'302331d 12304 3Nv131on1'1S L LS 'ONI `so-ivo )ioino l3'3a331d ld 3nlao>fvo M7z 331lvSV DMO :ao; pauuo:Pad :# aor 6 }aayS 0 * wrightsoft' Duct System Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 PM.'772-466-6799 EmaII:OUICKCALCS@AOLCOM For: DOUGLASALLEE 2432 OAK DRIVE, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.169/0.051 in H2O 0.080 in/100ft 1383 cfinn 186 It Job: Date: By: Cooling 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.169 /0.051 in H2O 0.080 in/100ft 1383 cfm Name Design (Btuh) Htg (cfrn) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 1294 58 27 0.080 5.0 0x0 VIFx 5.4 70.0 BATH c 1314 57 57 0.080 5.0 0x0 VIFx 13.0 70.0 BED h 3517 157 104 0.080 8.0 0x0 VFx 5.0 70.0 FAMILY IT 8026 357 354 0.080 8.0 0x0 VIFx 36.1 90.0 st1 KITCHEN c 1778 18 77 0.080 8.0 0x 0 V Fx 28.4 90.0 st1 LAUNDRY h 3385 151 93 0.080 7.0 0x0 VIFx 33.1 110.0 st1 LIVING c 3621 92 157 0.080 7.0 0x0 VFx 24.3 90.0 st1 LIVING ROOM IT 3569 159 149 0.080 7.0 0x0 VIFx 31.6 110.0 st1 LNING-A c 3621 92 157 0.080 7.0 0x0 VIFx 20.8 90.0 st1 MASTERBED h 5433 242 209 0.080 8.0 0x0 VIFx 11.4 70.0 Name Trunk Type Htg (drn) Clg (dM) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st1 PeakAVF 870 986 0.080 706 16.0 0 x 0 VinIFIX * wrightsoft, 2020-Mapl 5 09:03:22 a ....,. •n,.. Ri M-Sule®Uriwfsa120101g.0.07RSU08101 Page 7 ,F,......:.......�, 9 �iCit� ...CK0awrerts\Wng"9 t HJAG\ALLEE, DOUGLAS.np Calc=MJ8 Frort Door fares: W Return BranchD.eta�l Table Name PG lie Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct PeakAVF Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Mat[ Trunk rb3 0x0 402 398 42.7 0.118 512 12.0 Ox 0 VIFx rt1 rb2 Oxo 628 542 40.8 0.124 1422 9.0 Ox 0 VIFx rt1 rb1 0x0 353 442 23.6 0.214 563 12.0 Ox 0 VlFx rt1 Name Trunk Type Htg (cfm) Clg (cfm) Design FR Ueloc I (fpm) Diam I (in) H x W (in) Duct Material Trunk rt1 PeakAVF 1383 1383 0.118 991 16.0 0 x 0 VinlFix Wf ightsofte 2020 -May 15 �iCi� RigH-Sute�J Urrversa1201919.0.07 RSU08101 Paget ...cKC0CUrae,tMWrigMsoff W ALLEE, DOUGLAS.rrp Cale =MJ8 FroN Door fares: W Project Summary Date; wrightsoft° Entire House By. QUICK CALCS, INC. 317 SL LUCIE LANE, FORT PIERCE, FL34946 Phone: 772-46M799 Email: QU1CKCALCS@AOL.COM For: DOUGLASALLEE 2432 OAK DRIVE, FT. PIERCE, FL Notes: Calculations approved byACCA to meet all requirements of Manual J 8th Ed. nriuhtsoft- 2020 -May -1509:03:22 P. �• RigttSdte9UNversa1201919.0.07RSU06101 Pagel ...CK\Doainerts\WdgtlwftWACWLLEE,DOUGLAS.rip CaIo=MJ6 Frol Doorfares: W ®- • o e Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 24883 Btuh Structure 23261 Btuh Ducts 6169 Btuh Ducts 8725 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 31052 Btuh Use manufacturel's data n Rate/swingg multiplier Equipme11sensible load 0.95 30387 Btuh Infiltration Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2215 Btuh Ducts 2379 Btuh Central vent (0 cfm) 0 Btuh Heating Coaling (none) Area (ft') 1691 1691 Equipment latent load 4594 Btuh Volume (ft') 15905 15905 Airchanges/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 34981 Btuh Equiv. AVF (cfm) 101 53 Req. total capacity at 0.70 SHR 3.6 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade EXISTING Model Cond 14AJM42A01 AHRI ref Coil RHLL-HM3821JA AHRI ref Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating Input 7.8 kW Sensible cooling 29050 Btuh Heating output 26550 Btuh Latentcooling 12450 Btuh Temperature ase 17 OF Total cooling 41500 Btuh Actual air flow 1383 cfirn Actual air flow 1383 cfm Airflowfactor 0.045 cfm/Btuh Airflowfactor 0.043 cf-n/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.87 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. nriuhtsoft- 2020 -May -1509:03:22 P. �• RigttSdte9UNversa1201919.0.07RSU06101 Pagel ...CK\Doainerts\WdgtlwftWACWLLEE,DOUGLAS.rip CaIo=MJ6 Frol Doorfares: W Sheet 1 Job M Performed for: DOUGLASALLEE 2432 OAK DRIVE FT. PIERCE, FL QUICK CALCS, INC. 317 ST. LUCIE LANE FORT PIERCE, FL34946 Phone: 772-0666799 QUICKCALCS@AOL.COM Scale: 1 :82 Page 1 Right-Suite(R) Universal 2019 19.0.07 RSU08101 20204Nay4 5 09:03:57 ...ightsofl HVACW..LEE, DOUGLAS.mp + wrightsoft' Duct System Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL34946 Ptnre: 772-4666799 Email: OUICKCALCS@AOL.COM For: DOUGLASALLEE 2432 OAK DRIVE, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.169 / 0.051 in H2O 0.080 in/100ft 1383 cfm 186 ft Job: Date: 6y. Cooling 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.169/0.051 in H2O 0.080 in/100ft 1383 cfm . SupplyBrancfa pefail Table Name Design (Btuh) Hig (clm) Clg (ef n) Design FR Diam (in) H x W (in) Duct Mafl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH IT 1294 58 27 0.080 5.0 Oxo VIFx 5.4 70.0 BATH c 1314 57 57 0.080 5.0 Oxo ViFx 13.0 70.0 BFD2 h 3517 157 104 0.080 8.0 0x0 VIFx 5.0 70.0 FAMILY IT 8026 357 354 0.080 8.0 0x0 VIFx 36.1 90.0 st1 KITCHEN c 1778 18 77 0.080 8.0 Oxo VIFx 28.4 90.0 sit LAUNDRY IT 3385 151 93 0.080 7A 0x 0 V Fx 33.1 110.0 st1 LIVING c 3621 92 157 0.080 7.0 Ox 0 V Fx 24.3 90.0 st1 WING ROOM IT 3569 159 149 0.080 7.0 0x0 VFx 31.6 110.0 st1 LIVING -A c 3621 92 157 0.080 7.0 0x0 VIFx 20.8 90.0 st1 MASTER BED IT 5433 242 209 0.080 8.0 0x0 VIFx 11.4 70.0 r, Supply Trunk Detail Table Name Trunk Type Htg (cfm) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st1 PeakAVF 870 986 0.080 706 16.0 0 x 0 VmIFlx 'P Wrightsoft' 202o-Ma¢1509:03:22 Rigtt-Sute®Uriversal 2019 19.0.07 RSU08101 Page 1 CKV➢octnteris\WdghwftWAMLLEE,DDUGLAS.rW Calc -i Frad Doorfaces: W ' ,,;Return B -ranch Detail Tahle r Return�Trunk Detail,Uble Name Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct PeakAVF Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Mail Trunk rb3 0x0 402 398 42.7 0.118 512 12.0 Ox 0 VIFx rt1 rb2 0x0 628 542 40.8 0.124 1422 9.0 Ox 0 VIFx rt1 rb1 Oxo 353 442 23.6 0.214 563 12.0 Ox 0 VIFx rt1 Return�Trunk Detail,Uble Name Trunk Type Htg (GfM) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk rt1 PeakAVF 1383 1383 0.118 991 16.0 0 x 0 VinlFlx wrights Oft' 2026May-1509.03:22 um. m.. .e.....�cm,.� Rlglt-SOte® Unversal 2019 19.0,07 RSU08101 Page 2 kc -k ._CK\Dawverts\Wdghsolt WACWLLEE, 000GLAS.rW Calc=MJII Fron Door tacos: W