Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product approvals, FL Shingle Roof Owens Corning
o- 13CIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search bWw%f 3 Product Approval `4USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL10674-R15 Revision 2017 Approved Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com Greg Keeler greg.keeler@owenscorning.com Mei Sancrant 1 Owens Corning PKWY Toledo, OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Roofing Asphalt Shingles Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert J.M. Nieminen Evaluation Report Florida License PE -59166 Quality Assurance Entity PRI Construction Materials Technologies, LLC. Quality Assurance Contract Expiration Date 01/01/2099 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL10674 R15 COI 2019 01 COI NIEMINEN.pdf Standard ASTM D1970 ASTM D3161 ASTM D3462 ASTM D7158 Year 2015 2016 2010 2011 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved FL # 10674.1 Method 1 Option D 08/15/2019 08/15/2019 08/21/2019 10/15/2019 Model, Number or Name Owens Corning Asphalt Roofing Shingles and Starters Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Refer to ER, Section 5. Description 3 -tab, 4 -tab, 5 -tab, laminated, starter and hip & ridge shingles Installation Instructions FL10674 R15 II 2019 08 FINAL ER OC ASPHALT SHINGLES FL10674-R15.pdf Verified By: Robert J. M. Nieminen PE - 59166 Created by Independent Third Party: Yes Evaluation Reports FL10674 R15 AE 2019 08 FINAL ER OC ASPHALT SHINGLES FL10674-R15.pdf Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: PrivacyStatement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: �® Eq M Credit Card Safe I NEW I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY REPORTEVALUATION Owens Corning Evaluation Report 037940.02.12-1110 One Owens Corning Parkway FL10674-1115 Toledo, ON 43659 Date of Issuance: 02/06/2012 (740) 404-7829 Revision 10: 08/15/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: Robert J.M. Nieminen P.E. 'ate a b r' The facsimile seal appearing was authorized by Robert ' ;FSS ^• Nieminen, P.E. on 08/15/2019. This does not serve as an Florida Registration No. 59166, Florida DCA ANE1983 electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOJetc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMOletc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO I etc. nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018, NEMO ETC, LLC ONEMOletc. ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 6t" Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Prope Standard Year 1507.2.4, R905.2.3 Physical Properties ASTM D1970 2015 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: gniibf Examination Reference Date Owens Corning Declaration Equivalency Declaration 08/06/2019 PRI(TST5878) ASTM D1970 OCF-382-02-01 10/24/2017 UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-112453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs Various PRI (QUA9110) Quality Control Service Confirmation 04/05/2020 4.1 ACCESSORY STARTERS: 4.1.1 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter are starter strips for asphalt roof shingles. Meets ASTM D3462, 4.1.2 Starter Shingle Roll is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen starter strip, nominal 7.2 -inch wide x 33 -ft 4 -inch long roll, for use with asphalt shingles. Meets ASTM D1970. 4.2 ASPHALT SHINGLES: 4.2.1 Classic and Supreme® are fiberglass reinforced, 3 -tab asphalt roof shingles. Meets ASTM D3462. 4.2.2 Berkshire® are fiberglass reinforced, 4 -tab asphalt roof shingles. Meets ASTM D3462. 4.2.3 Duration, TruDefinition' Duration, Duration' Premium Cool, TruDefinition Duration" Designer Color Collection, TruDefinition® Oakridge®, Oakridge' and WeatherGuard® HP are fiberglass reinforced, laminated asphalt roof shingles. Meets ASTM D3462. 4.3 HIP & RIDGE SHINGLES: 4.3.1 Berkshire Hip & Ridge Shingles with Sealant, DuraRidge® Hip & Ridge Shingles with Sealant, ProEdgeO Hip & Ridge Shingles and WeatherGuard HP Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. Meets ASTM D3462. NEMO ETC, LLC Evaluation Report 037940.02.12-R10 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-RIS Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 2 of 10 ONEMOIetc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 The Owens Corning asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating acceptable use in all wind zones UP to V.sd = 150 mph (V,It =194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Note: Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.2 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter noted in Section 4.1.1 and the Owens Corning hip & ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating acceptable use in all wind zones up to Vmd = 150 mph (V„It = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and published installation instructions. 6.2 ACCESSORY STARTERS: 6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens Corning current published instructions, using minimum five (5) nails per strip. Feltundedayment Deck Selfadhered WeatherLocke 1 underlayment Drip_. Drip edge edge y ' Nails located 2.-31, from save Install first SeH-searing adhesive Starter Stripp r' positioned alone save shinglewNh.—___..._.."' \ S" removed Starter Strip shingle overhangs eaves and rakes %i' W' Deck S*4dhered WnatY—r uMe&yment Drip edge _ NsAttowed 2"-3" fmm ave Sditimd eto aw positioned done ave Starter Strip Plus avahangsaves ad rake; 7/4"-314' Figure 1: Minimum Nailing, Starter Strip Figure 2: Minimum Nailing, Starter Strip Plus NEMO ETC, LLC Evaluation Report 037940.02.12-R10 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R35 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 3 of 20 ONEMOjetc. 6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions. Deck unaenaymeni Drip edge Drip edge Starter Shingle Roil adhered directly to underlayment and primed drip edge Self-sealing adhesive positioned along eaves Figure 3: Starter Shingle Roll 6.3 ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: Y Berkshire shingles require minimum five (5) nails per shingle. Y WeatherGuard® HP shingles require minimum six (6) nails per shingle. Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required Refer to Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Classic® & Supreme: Normal Mansard or Area para Wind Areas High Wind desvanes y Area para vientos normales Areas vientos Mertes 5"Exposure Exposioi6n Figure 4: Minimum Nailing, Classic & Supreme (Standard Size) Normal Mansard or Area pars Wind Areas High Wind desvanes y Area para vientos normafas Areas vientos fuertes .. .. 5 518" Exposure Exposicf6a Figure 5: Minimum Nailing, Classic & Supreme (Metric Size) NENIO ETC, LLC Certificate of Authorization #32455 6T" EDITION (2017) FBG NON-HVHZ EVALUATION Owens Corning Asphalt Roof Shingles Evaluation Report 037940.02.12-R10 FL10674-R15 Revision 30: 08/15/2019 Page 4 of 10 6.3.1.2 Berkshire®: t*dlant strip La lira de segadm Figure 6: 5 -Nail Pattern, Berkshire ONEMOjetc. Sealant strip La tlra de sellador t" L L Y - Figure 7: 6 -Nail Pattern, Berkshire Sealant strip La Ura de sellader 8 vt' s+it' t3 Yt s 11f t., 2' Asphalt rooting cement Comma de rocho de astaho Figure 8: Mansard or Steep Slope Pattern, Berkshire NEMO ETC, LLC Evaluation Report 037940.02.12-R10 Certificate of Authorization #32455 CH EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1115 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 5 of 10 6.3.1 MEMO I etc. 4 -Nall Fastening Pattern SureNallOfasfening area width Naif, Typical 1' 1Z �wensCmnina SurN,Jaif • .•pp aars56oww�v»MO Owe�C«nmBSwa 6.118" 8 b18" ' exPosurt Figure 9: Standard 4 -Nail Pattern, Duration Fastening for Slopes Greater Than 21:12 Lbij—:' all* fastening area width Nail, Typical 1" 12" 12" �wamx Cu nt g S Naa R • �amp I •OwurB Coming 6-118" 5Sl8" exposure Four 1" Spots of Asphalt Roofing Cement Figure 11: Mansard or Steep Slope Pattern, Duration 2" NEMO ETC, LLC Evaluation Report 037940.02,12-R30 Certificate of Authorization #31455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 6 of 10 ONEMOletc. 6.3.1.4 TruDefinitione Oakridge®. Oakridge®: 4 Nall Pattern Esguema con 4 clavus 1" T. I5518" Exposure N" g 5 518" Exposure I Expm[d6n do 6 6/B puig. clav" Exposleldn da 6 6/8 puig. Figure 12: Standard 4 -Nail Pattern, Oakridge 6 Nail Pattern Esquema con 6 clavas 1„ 1^ V.,, .T12" 5 5M' Exposure Nails Cfavos 5 5/8" Exposure Exposiddn de 56/0 ping. Exposfd6n de 66/9pulg. Figure 13: 6 -Nail Pattern, Oakridge Fastening for Slopes Greater Than 21:12 SumNall0 fastening area width ' 1 1 Nell, Typical 12" &118° 5SlS"� .xnaun Pour 1" Spots ofmphait Roofing cement Figure 14: Mansard or Steep -Slope Pattern, Oakridge NEMO ETC, LLC Evaluation Report 037940.02.12-1110 Certificcite o}Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.10674-1115 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 7 of 10 6.3.1.5 WeatherGuard® HP: fs�c�adE+ido 55B �u#g. s 5 Ewe Figure Fxpaaci3n de 5 Figure 15: 6 -Nail Pattern, WeatherGuard HP 6 Nell Pattern Esquema con 6 clavos Nail 61T from bottom of shinoe ave a 6 1i8 pu4. de la 5 5W Exposure 6 Fasteners parte inferior de la tqa Expodckrri de 5 51 pulg. 6 sujetadores Four 1" Spots of Asphalt hoof Cement Cuatio puntas de cemento do tedra de aslatto ate f pulgada Figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HP ONEMOjetc. 6.4 HIP & RIDGE SHINGLES: 6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions. ➢ Berkshire* Hip and Ridge Shingles with Sealant and DuraRidge® Hip & Ridge Shingles with Sealant require minimum two (2) nails per shingle. WeatherGuard® HP Hip and Ridge Shingles and ProEdge® Hip & Ridge Shingles require minimum four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations. NEMO ETC, LLC Evaluation Report 037940.02.12-1110 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 8 of 10 6.4.1.1 Berkshire® Hip & Ridge with Sealant and DuraRidgee Hip & Ridee Shingles with Sealant: Fig. A Prevailing Wind Direction 4— Direccion del viento predorninante 0 Nails Clavos I I I I A I I I t -f Exposure Exposicion de 8 pulp 4 A Figure 17: Isometric View, Berkshire and DuraRidge 6.4.1.2 WeatherGuard® HP Hip & Ridge Shingles: Fig. A q Q Prevailing Wind 4— Orrection A A Nails q q A 1 1 qq I I A I I I I Exp sure Figure 19: Isometric View, WeatherGuard HP Hip & Ridge MEMO ( etc. Fig' B Top View Vista superior Nail Clavo ar ( J i NEMO ETC, LLC Evaluation Report 037940.02.12-R10 Certificate of Authorization tJ32455 6T" EDITION (2017) FOC ( J i Figure 18: Plan View, Berkshire and DuraRidge Fig. G Hip & Ridge Shingle Fastening Top clew Nails MRS 7, 2" 2" S„ Exposure 1" Figure 20: Plan View, WeatherGuard HP Hip & Ridge NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision iD: 08/15/2019 Page 9 of 10 6.4.1.3 ProEdge® Hip & Ridge Shingles: Prevailing Wind Direction Sealant Stip A--"' 6" Exposure Fasten Vit" Cover Exposed Fasteners with Reef Cement ' ONEMOjetc. Standard t f "—• Fastening Pattern :2T t'I I, �- �I•I I- r 1" 12" I Sealanture Figure 21: Isometric View, ProEdge Figure 22: Plan View, ProEdge 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. 8. BUILDING PERMIT • As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61620-3 QA requirements. s QUALITY PRI Construction Materials Technologies, LLC— QUA9110 ; 813 621-5777; bwilson@pricmt.com - END OF EVALUATION REPORT - NEMO ETC, LLC Certificate of Authorization 1132455 6" EDITION (2017) FBC NON-HVHZ EVALUATION Owens Corning Asphalt Roof Shingles Evaluation Report 037940.02.12-1110 F1.10674-1115 Revision 30: 08/15/2019 Page 10 of 10