HomeMy WebLinkAboutEnergy CodeFORM R405-2017
.,, FLORIDA ENERGY EFFICIENCY CODE FOR BUILDI G C""''T�RJCTI N
Florida Department of Business and Professional Regulation - Reside tial Pe rt� c6: etho
i4(K _ I
i
r;T•
Lucie CQuntyr Permitting
Project Name: Hinkle Residence
Builder Name:
Street: 7405 Silver Oak Drive
Permit Office: St. Lucie County
City, State, Zip: Port St. Lucie , FL, 34952
Permit Number:
Owner: Hinkle Residence
Jurisdiction: St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wail Types (2445.8 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=13.1 2175.80 ft'
b. Frame - Wood, Adjacent
R=11.0 270.00 ft'
3. Number of units, if multiple family 1
c. N/A
R= ft'
4. Number of Bedrooms 3
d. NIA
R= ft'
5. Is this a worst case? No
10. Ceiling Types (2818.0 sgft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 2818.00 ft'
6. Conditioned floor area above grade (ft� 2818
b. NIA
R= ft'
Conditioned floor area below grade (ft') 0
c. NIA
R= ft'
11. Ducts
R ft'
7. Windows(352.2 scift.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 140
a. U-Factor: Dbl, U=0.40 276.17 ft'
1
SHGC: SHGC=0.20
b. U-Factor: Dbl, U=0.40 76.00 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
48.0 SEER:17.00
c. U-Factor: N/A ft'
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft'
a. Electric Strip Heat
34.0 COPA.00
SHGC:
Area Weighted Average Overhang Depth: 4.840 ft.
Area Weighted Average SHGC: 0.211
14. Hat water systems
a. Natural Gas Tankiess
Cap: 1 gallons
8. Floor Types (2818.0 scift.) Insulation Area
EF: 0.600
a. Slab -On -Grade Edge Insulation R=0.0 2818.00 0'
b. Conservation features
b. N/A R= ft'
None
c. NIA R= ft'
15. Credits
CF, Pslal
Glass/Floor Area: 0.125 Total Proposed Modified Loads: 69.93
PASS
Total Baseline
Loads: 86.75
1 hereby certify that the plans and specifications covered by
Review of the plans and
STg7
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
pj rip 53 r „c`00%
with the Florida Energy Code,
1. uorr. ';" `•;
PREPARED BY:4A&kQV
DATE:
Before construction is completed
this building will be inspected for
r R C
0 ^ V a
compliance with Section 553.908
I hereby certify that this building, as design '�1 compliance
Florida Statutes.
lt,C �.
with the Florida Energy cc
OD,1WE S�
OWNER/AG NT1�7-
BUILDING OFFICIAL:
DATE: I��
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handles enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (11402.4.1.2).
4/7/2019 6:37 PM EnergyGaugeO USA Section R405.4.1 Compliant Software
FILE CPage 1 Op1 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Hinkle Residence
Bedrooms:
3
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2818
Lot #
Owner Name:
Hinkle Residence
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
Rotate Angle:
0
Street:
7405 Silver Oak
Drive
Permit Office:
St. Lucie County
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
St. Lucie County
Whole House Fan:
No
City, State,
Zip:
Port St. Lucie ,
Family Type:
Single-family
FL, 34952
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2818
29402.2
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
Infil ID
Finished Cooled
Healed
1
Bedroom 3
221
2210 No
1
1
1
Yes
Yes
Yes
2
WIC 4
30
300 No
0
1
Yes
Yes
Yes
3
WIC 3
30
300 No
0
1
Yes
Yes
Yes
4
Bathroom
96
960 No
0
1
No
Yes
Yes
5
Bedroom 2
182
1820 No
1
1
1
Yes
Yes
Yes
6
Sports Room
132
1320 No
2
1
Yes
Yes
Yes
7
Dining
165
1650 No
2
1
Yes
Yes
Yes
8
Kitchen
252
2520 Yes
1
1
No
Yes
Yes
9
Living Room
374
4600.2 No
1
1
Yes
Yes
Yes
10
Master Bedroom
362
3982 No
2
1
1
Yes
Yes
Yes
11
WIC 1
72
720 No
0
1
Yes
Yes
Yes
12
Master Bath
200
2000 No
0
1
Yes
Yes
Yes
13
WIC 2
56
560 No
0
1
No
Yes
Yes
14
Media
12
120 No
0
1
No
Yes
Yes
15
Office
132
1320 No
1
1
Yes
Yes
Yes
16
Foyer
100
1000 No
0
1
Yes
Yes
Yes
17
Laundry
126
1260 No
0
1
Yes
Yes
Yes
18
Pantry
42
420 No
0
1
No
Yes
Yes
19
Powder
30
300 No
0
1
No
Yes
Yes
20
Hall
116
1160 No
0
1
No
Yes
Yes
21
Garage Entry
66
660 No
0
1
No
Yes
Yes
22
Toilet
22
220 No
0
1
Yes
Yes
Yes
4/7/2019 6:37 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulatio
Bedroom 3
30 ft
0
221 ft'
—
1
0
0
2 Slab -On -Grade Edge Insulatio
WIC 4
6 ft
0
30 ft'
—
1
0
0
3 Slab -On -Grade Edge Insulatio
WIC 3
6 ft
0
30 ft'
—
1
0
0
4 Slab -On -Grade Edge Insulatio
Bathroom
t ft
0
96 ft
—
1
0
0
5 Slab -On -Grade Edge Insulatio
Bedroom 2
14 ft
0
182 ft'
____
1
0
0
6 Slab -On -Grade Edge Insulatio
Sports Room
12 ft
0
132 ft'
—
1
0
0
7 Slab -On -Grade Edge Insulatio
Dining
26 ft
0
165 ft'
—
1
0
0
8 Slab -On -Grade Edge Insulatio
Kitchen
1 ft
0
252 ft'
____
1
0
0
9 Slab -On -Grade Edge Insulatio
Living Room
14 It
0
374 ft'
—
1
0
0
10SIab-On-Grade Edge Insulatio
Master Bedroom 35 ft
0
362 ft'
_
1
0
0
11Slab-On-Grade Edge Insulatio
WIC 1
12 ft
0
72 ft'
—
1
0
0
12SIab-On-Grade Edge Insulatio
Master Bath
25 ft
0
200 ft'
_
1
0
0
13Slab-On-Grade Edge Insulatio
WIC 2
1 ft
0
56 ft'
—
1
0
0
14SIab-On-Grade Edge Insulatio
Media
1 ft
0
12 ft'
____
1
0
0
15SIab-On-Grade Edge Insulatio
Office
11 ft
0
132 ft'
—
1
0
0
16SIab-On-Grade Edge Insulatio
Foyer
6 ft
0
100 ft'
—
1
0
0
17Slab-On-Grade Edge Insulatio
Laundry
7 ft
0
126 ft'
_
1
0
0
18SIab-On-Grade Edge Insulatio
Pantry
1 ft
0
42 ft'
_
1
0
0
19SIab-On-Grade Edge Insulatio
Powder
1 ft
0
30 ft'
_
1
0
0
20SIab-On-Grade Edge Insulatio
Hall
1 ft
0
116 ft'
1
0
0
21SIab-On-Grade Edge Insulatio
Garage Entry
1 ft
0
66 ft'
_
1
0
0
22Slab-On-Grade Edge Insulatio
Toilet
loft
0
2212
___
1
0
0
ROOF
/
Roof
Gable
Roof
Solar
SA Emitt
Emift
Deck
Pitch
V
# Type Materials
Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Hip
Metal 3052 ft'
0 ft'
Light
0.6
No 0.9
No
20
22.6
ATTIC
/
V
# Type
Ventilation
Vent Ratio (1
in)
Area
RBS IRCC
1 Full attic
Unvented
0
2818 ft'
N N
4/7/2019 6:37 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) Bedroom 3
20
Blown
221 it'
0.1
Wood
2
Under Attic (Unvented) WIC 4
20
Blown
30 ft2
0.1
Wood
3
Under Attic(Unvented) WIC
20
Blown
30 ft2
0.1
Wood
4
Under Attic (Unvented) Bathroom
20
Blown
96 ft2
0.1
Wood
5
Under Attic (Unvented) Bedroom 2
20
Blown
182 ft2
0.1
Wood
6
Under Attic (Unvented) Sports Room
20
Blown
132 it'
0.1
Wood
7
Under Attic (Unvented) Dining
20
Blown
165 ft2
0.1
Wood
8
Under Attic (Unvented) Kitchen
20
Blown
252 ft2
0.1
Wood
9
Under Attic (Unvented) Living Room
20
Blown
374 ft2
0
Wood
10
Under Attic (Unvented) Master Bedroom 20
Blown
362 ft2
0.1
Wood
11
Under Attic (Unvented) WIC 1
20
Blown
72 ft2
0.1
Wood
12
Under Attic (Unvented) Master Bath
20
Blown
200 ft2
0.1
Wood
13
Under Attic (Unvented) WIC 2
20
Blown
56 ft2
0.1
Wood
14
Under Attic(Unvented) Media
20
Blown
12 ft2
0.1
Wood
_
15
Under Attic (Unvented) Office
20
Blown
132 ft2
0.1
Wood
16
Under Attic (Unvented) Foyer
20
Blown
100 ft2
0.1
Wood
17
Under Attic (Unvented) Laundry
20
Blown
126 ft2
0.1
Wood
18
Under Attic (Unvented) Pantry
20
Blown
42 ft2
0.1
Wood
19
Under Attic (Unvented) Powder
20
Blown
30 ft2
0.1
Wood
20
Under Attic (Unvented) Hall
20
Blown
116 ft2
0.1
Wood
21
Under Attic (Unvented) Garage Entry
20
Blown
66 ft2
0.1
Wood
22
Under Attic (Unvented) Toilet
20
Blown
22 ft2
0.1
Wood
WALLS
Adjacent Space
Cavity
Width
Height
Sheathing Framing Solar
Below
_ 1
S
Exterior Concrete Block - Int InsuBedroom 3
13.1
13
0 10
0
130.0 ft2
0
0
0.6
0
_ 2
W
Exterior Concrete Block - Int InsuBedroom 3
13.1
17
0 10
0
170.0 ft2
0
0
0.6
0
_ 3
S
Exterior Concrete Block- Int Insul WIC 4
13.1
6
0 10
0
60.0 ft2
0
0
0.6
0
-4
S
Exterior Concrete Block - Int Insul WIC 3
13.1
6
0 10
0
60.0 ft2
0
0
0.6
0
_ 5
S
Exterior Concrete Block - Int InsuBedroom 2
13.1
14
0 10
0
140.0 ft2
0
0
0.6
0
_ 6
S
Exterior Concrete Block - Int Ins®ports Room
13.1
12
0 10
0
120.0 ft2
0
0
0.6
0
-7
N
Exterior Concrete Block-Int Insul Dining
13.1
11
0 10
0
110.0112
0
0
0.6
0
_ 8
W
Exterior Concrete Block - Int Insul Dining
13.1
15
0 10
0
150.0 ft2
0
0
0.6
0
_ 9
W
Exterior Concrete Block - Int Insdliving Room
13.1
11
5 12
4
140.8 ft2
0
0
0.6
0
10
N
Exterior Concrete Block - Int lnsMaster Bedro
13.1
18
0 11
0
198.0 ft2
0
0
0.6
0
_ 11
W
Exterior Concrete Block - Int lnsMaster Bedro
13.1
17
0 11
0
187.0 ft2
0
0
0.6
0
_ 12
N
Exterior Concrete Block - Int Insul WIC 1
13.1
12
0 10
0
120.0 ft2
0
0
0.6
0
_ 13
N
Exterior Concrete Block - Int InsMMaster Bath
13.1
12
0 10
0
120.0 ft2
0
0
0.6
0
_ 14
E
Exterior Concrete Block - Int InsWaster Bath
13.1
11
0 10
0
110.0 ft2
0
0
0.6
0
15
S
Exterior Concrete Block- Int InsMMaster Bath
13.1
2
0 10
0
20.0 ft'
0
0
0.6
0
16
E
Exterior Concrete Block - Int Insul Office
13.1
11
0 10
0
110.0 ft2
0
0
0.6
0
17
E
Exterior Concrete Block - Int Insul Foyer
13.1
6
0 10
0
60.0 ft2
0
0
0.6
0
18
N
Exterior Concrete Block - Int Insul Laundry
13.1
4
0 10
0
40.0 ft2
0
0
0.6
0
4/7/2019 6:37 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing Solar
Below
_ 19
E
Exterior
Concrete Block - Int
Insul Laundry
13.1 3
0
10 0
30.0 ft2
0
0 0.6
0
20
E
Exterior
Concrete
Block - Int
Insul Toilet
13.1 6
0
10 0
60.0 112
0
0 0.6
0
21
S
Exterior
Concrete Block - Int
Insul Toilet
13.1 4
0
10 0
40.0 ft2
0
0 0.6
0
22
N
Garage
Frame -Wood
Sports Room 11 12
10
120.0 ft2
0
0.25 0.600000
0
23
N
Garage
Frame - Wood
Garage Entry 11 6
10
60.0 ft2
0
0.25 0.600000
0
24
N
Garage
Frame - Wood
Laundry
11 9
10
90.0 ft2
0
0.25 0.600000
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Omt ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade Screening
1
S
1
Vinyl
Low-E Double
Yes
0.4 0.2
N
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
2
W
2
Vinyl
Low-E Double
Yes
0.4 0.2
N
30.0 ft2
2 it 0 in
1 ft 4 in
None
None
3
S
5
Vinyl
Low-E Double
Yes
0.4 0.2
N
12.0 ft2
2 It 0 in
1 ft 4 in
None
None
4
S
6
Vinyl
Low-E Double
Yes
0.4 0.2
N
10.0 ft'
2 ft 0 in
1 ft 4 in
None
None
5
N
7
Vinyl
LowaE Double
Yes
0.4 0.2
N
30.0 112
2 It 0 in
1 ft 4 in
None
None
6
W
8
Vinyl
Low-E Double
Yes
0.4 0.2
N
30.0 ft2
2 ft 0 in
1 It 4 in
None
None
7
W
9
Vinyl
Low-E Double
Yes
0.4 0.25
N
48.0 ft2
10 It 0 in
1 ft 4 in
None
None
8
N
10
Vinyl
Low-E Double
Yes
0.4 0.2
N
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
9
W
11
Vinyl
Low-E Double
Yes
0.4 0.2
N
48.0 ft2
10 It 0 in
1 ft 4 in
None
None
10
N
13
Vinyl
Low-E Double
Yes
0.4 0.2
N
20.0 ft'
2 It 0 in
1 ft 4 in
None
None
11
E
14
Vinyl
Low-E Double
Yes
0.4 0.2
N
8.2 ft2
2 ft 0 in
1 ft 4 in
None
None
_
12
E
14
Vinyl
Low-E Double
Yes
0.4 0.2
N
10.0 ft2
2 It 0 in
1 ft 4 in
None
None
13
E
16
Vinyl
Low-E Double
Yes
0.4 0.2
N
20.0 IF
6 It 0 in
1 ft 4 in
None
None
14
E
17
Vinyl
Low-E Double
Yes
0.4 0.25
N
28.0 ft'
6 ft 0 in
1 ft 4 in
None
None
15
E
19
Vinyl
Low�E Double
Yes
0.4 0.2
N
10.0 ft'
6 ft 0 in
1 ft 4 in
None
None
16
E
20
Vinyl
Low-E Double
Yes
0.4 0.2
N
10.0 ft2
2 ft 0 in
1 it 4 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
676 ft2
676 ft2
28 ft
l o ft
11
INFILTRATION
# Scope
Method
SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .000464 3430.3 188.32
354.16
.3641
7
07/2019 6:37 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COP:1
34 kBlu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit/
Split
SEER: 17
48 kBtu/hr
cfm
0.7
1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1
Natural Gas Tankless
Exterior
0.6 1 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart
# Company Name
System Model # Collector
Model
# Area
Volume
FEF
None None
ft'
DUCTS
_ /
—Supply—
—Return—
Air
CFM 25
CFM25
HVAC#
V #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
ON
RLF
Heat Coal
1
Attic 6 140 ft'
Attic
40 ft' Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programablre T]hermostar[t:']Y
Ceiling Fans:
Heating
((�]
Jan Feb LXl Mar
f ]
[ ] Apr [
r f
I May rl Jun [x� Jul
[X
[ Aug
[X]
[ ]Sep
[ ]
Q
Oct
H
Venting I I
l l
Jan I 1 Feb l[�X1 Mar
l l
Ix] [
I Jun I Jul
I Aug
I ] Sep
lxl
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM 78
78 78
78 78 76
78
78
80
80
80
80
PM 80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM 78
78 78
78 78 78
78
78
78
78
78
78
PM 78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM 66
66 66
66 66 68
68
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM 66
66 66
66 66 68
68
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
66
66
4/7/2019 6:37 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 7
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbs/sq.ft.
0 ft2
0 ft
0.3
Bedroom 3
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC4
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC 3
Default(8 lbslsq.ft.
ft2
ft
0.3
Bathroom
Default(8 lbs/sq.ft.
ft2
ft
0.3
Bedroom 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
Sports Room
Default(8 lbs/sq.ft.
ft2
ft
0.3
Dining
Default(8 lbs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8 lbs/sq.ft.
ft2
ft
0.3
Wing Room
Default(8 lbs/sq.ft.
ft2
ft
0.3
Master Bedroom
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC 1
Default(S lbs/sq.ft.
ft2
ft
0.3
Master Bath
Default(S Ibs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8 lbslsq.ft.
ft2
ft
0.3
Media
Defaull(8 lbs/sq.ft.
ft2
ft
0.3
Office
Default(8 lbs/sq.ft.
ft2
ft
0.3
Foyer
Default(8 lbs/sq.ft.
ft2
ft
0.3
Laundry
Default(8 lbs/sq.ft.
ft2
ft
0.3
Pantry
Default(8 lbs/sq.ft.
ft2
ft
0.3
Powder
Default(8 lbs/sq.ft.
ft2
ft
0.3
Hall
Default(8 lbs/sq.ft.
ft2
ft
0.3
Garage Entry
Default 8lbs/s .ft.
ft2
ft
0.3
Toilet
Name: Signature: 1 f M /IAxW A JL L'Y
Rating Compant: Date: to 1
4/7/2019 6:37 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 7 of 7
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Hinkle Residence Builder Name:
Street: 7405 Silver Oak Drive Permit Office: St. Lucie County
City, Slate, Zip: Port St. Lucie , FL , 34952 Permit Number:
Y
U
Owner: Hinkle Residence Jurisdiction: St. Lucie County
W
x
Design Location: FL, Fart Pierce
ci
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceilinglattic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfioor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall he provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall,
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind n'nina an wirina
Showerltub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a mannerthat is recommended by the manufacturer.
I
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or cellinas
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
477/2019 6:38 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 81
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
48.0
a) Split system SEER
17.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
2818
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor.(weighted average)
7a.
0.400
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.211
14. Heating system: Capacity
34.0
c) Area
7c.
352.2
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor.(weighted average)
Be.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
16. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
b) Gas fired, natural gas EF
0.60
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
13.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1061.
11.0
2. Masonry (Insulation R-value)
1062.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
Yes
a) Under attic
11a.
20.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code cqmPI'Mi_ s.
Builder
Address of New Home: 7405 Silver Oak Drive City/FL Zip: Port St. Lucie, FL 34952
4/7/2019 6:38:03 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1