Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 .,, FLORIDA ENERGY EFFICIENCY CODE FOR BUILDI G C""''T�RJCTI N Florida Department of Business and Professional Regulation - Reside tial Pe rt� c6: etho i4(K _ I i r;T• Lucie CQuntyr Permitting Project Name: Hinkle Residence Builder Name: Street: 7405 Silver Oak Drive Permit Office: St. Lucie County City, State, Zip: Port St. Lucie , FL, 34952 Permit Number: Owner: Hinkle Residence Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wail Types (2445.8 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=13.1 2175.80 ft' b. Frame - Wood, Adjacent R=11.0 270.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 3 d. NIA R= ft' 5. Is this a worst case? No 10. Ceiling Types (2818.0 sgft.) Insulation Area a. Roof Deck (Unvented) R=20.0 2818.00 ft' 6. Conditioned floor area above grade (ft� 2818 b. NIA R= ft' Conditioned floor area below grade (ft') 0 c. NIA R= ft' 11. Ducts R ft' 7. Windows(352.2 scift.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 140 a. U-Factor: Dbl, U=0.40 276.17 ft' 1 SHGC: SHGC=0.20 b. U-Factor: Dbl, U=0.40 76.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 48.0 SEER:17.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Strip Heat 34.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 4.840 ft. Area Weighted Average SHGC: 0.211 14. Hat water systems a. Natural Gas Tankiess Cap: 1 gallons 8. Floor Types (2818.0 scift.) Insulation Area EF: 0.600 a. Slab -On -Grade Edge Insulation R=0.0 2818.00 0' b. Conservation features b. N/A R= ft' None c. NIA R= ft' 15. Credits CF, Pslal Glass/Floor Area: 0.125 Total Proposed Modified Loads: 69.93 PASS Total Baseline Loads: 86.75 1 hereby certify that the plans and specifications covered by Review of the plans and STg7 this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance pj rip 53 r „c`00% with the Florida Energy Code, 1. uorr. ';" `•; PREPARED BY:4A&kQV DATE: Before construction is completed this building will be inspected for r R C 0 ^ V a compliance with Section 553.908 I hereby certify that this building, as design '�1 compliance Florida Statutes. lt,C �. with the Florida Energy cc OD,1WE S� OWNER/AG NT1�7- BUILDING OFFICIAL: DATE: I�� DATE: - Compliance requires certification by the air handler unit manufacturer that the air handles enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (11402.4.1.2). 4/7/2019 6:37 PM EnergyGaugeO USA Section R405.4.1 Compliant Software FILE CPage 1 Op1 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Hinkle Residence Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2818 Lot # Owner Name: Hinkle Residence Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 7405 Silver Oak Drive Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Port St. Lucie , Family Type: Single-family FL, 34952 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2818 29402.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Healed 1 Bedroom 3 221 2210 No 1 1 1 Yes Yes Yes 2 WIC 4 30 300 No 0 1 Yes Yes Yes 3 WIC 3 30 300 No 0 1 Yes Yes Yes 4 Bathroom 96 960 No 0 1 No Yes Yes 5 Bedroom 2 182 1820 No 1 1 1 Yes Yes Yes 6 Sports Room 132 1320 No 2 1 Yes Yes Yes 7 Dining 165 1650 No 2 1 Yes Yes Yes 8 Kitchen 252 2520 Yes 1 1 No Yes Yes 9 Living Room 374 4600.2 No 1 1 Yes Yes Yes 10 Master Bedroom 362 3982 No 2 1 1 Yes Yes Yes 11 WIC 1 72 720 No 0 1 Yes Yes Yes 12 Master Bath 200 2000 No 0 1 Yes Yes Yes 13 WIC 2 56 560 No 0 1 No Yes Yes 14 Media 12 120 No 0 1 No Yes Yes 15 Office 132 1320 No 1 1 Yes Yes Yes 16 Foyer 100 1000 No 0 1 Yes Yes Yes 17 Laundry 126 1260 No 0 1 Yes Yes Yes 18 Pantry 42 420 No 0 1 No Yes Yes 19 Powder 30 300 No 0 1 No Yes Yes 20 Hall 116 1160 No 0 1 No Yes Yes 21 Garage Entry 66 660 No 0 1 No Yes Yes 22 Toilet 22 220 No 0 1 Yes Yes Yes 4/7/2019 6:37 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Bedroom 3 30 ft 0 221 ft' — 1 0 0 2 Slab -On -Grade Edge Insulatio WIC 4 6 ft 0 30 ft' — 1 0 0 3 Slab -On -Grade Edge Insulatio WIC 3 6 ft 0 30 ft' — 1 0 0 4 Slab -On -Grade Edge Insulatio Bathroom t ft 0 96 ft — 1 0 0 5 Slab -On -Grade Edge Insulatio Bedroom 2 14 ft 0 182 ft' ____ 1 0 0 6 Slab -On -Grade Edge Insulatio Sports Room 12 ft 0 132 ft' — 1 0 0 7 Slab -On -Grade Edge Insulatio Dining 26 ft 0 165 ft' — 1 0 0 8 Slab -On -Grade Edge Insulatio Kitchen 1 ft 0 252 ft' ____ 1 0 0 9 Slab -On -Grade Edge Insulatio Living Room 14 It 0 374 ft' — 1 0 0 10SIab-On-Grade Edge Insulatio Master Bedroom 35 ft 0 362 ft' _ 1 0 0 11Slab-On-Grade Edge Insulatio WIC 1 12 ft 0 72 ft' — 1 0 0 12SIab-On-Grade Edge Insulatio Master Bath 25 ft 0 200 ft' _ 1 0 0 13Slab-On-Grade Edge Insulatio WIC 2 1 ft 0 56 ft' — 1 0 0 14SIab-On-Grade Edge Insulatio Media 1 ft 0 12 ft' ____ 1 0 0 15SIab-On-Grade Edge Insulatio Office 11 ft 0 132 ft' — 1 0 0 16SIab-On-Grade Edge Insulatio Foyer 6 ft 0 100 ft' — 1 0 0 17Slab-On-Grade Edge Insulatio Laundry 7 ft 0 126 ft' _ 1 0 0 18SIab-On-Grade Edge Insulatio Pantry 1 ft 0 42 ft' _ 1 0 0 19SIab-On-Grade Edge Insulatio Powder 1 ft 0 30 ft' _ 1 0 0 20SIab-On-Grade Edge Insulatio Hall 1 ft 0 116 ft' 1 0 0 21SIab-On-Grade Edge Insulatio Garage Entry 1 ft 0 66 ft' _ 1 0 0 22Slab-On-Grade Edge Insulatio Toilet loft 0 2212 ___ 1 0 0 ROOF / Roof Gable Roof Solar SA Emitt Emift Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 3052 ft' 0 ft' Light 0.6 No 0.9 No 20 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2818 ft' N N 4/7/2019 6:37 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Bedroom 3 20 Blown 221 it' 0.1 Wood 2 Under Attic (Unvented) WIC 4 20 Blown 30 ft2 0.1 Wood 3 Under Attic(Unvented) WIC 20 Blown 30 ft2 0.1 Wood 4 Under Attic (Unvented) Bathroom 20 Blown 96 ft2 0.1 Wood 5 Under Attic (Unvented) Bedroom 2 20 Blown 182 ft2 0.1 Wood 6 Under Attic (Unvented) Sports Room 20 Blown 132 it' 0.1 Wood 7 Under Attic (Unvented) Dining 20 Blown 165 ft2 0.1 Wood 8 Under Attic (Unvented) Kitchen 20 Blown 252 ft2 0.1 Wood 9 Under Attic (Unvented) Living Room 20 Blown 374 ft2 0 Wood 10 Under Attic (Unvented) Master Bedroom 20 Blown 362 ft2 0.1 Wood 11 Under Attic (Unvented) WIC 1 20 Blown 72 ft2 0.1 Wood 12 Under Attic (Unvented) Master Bath 20 Blown 200 ft2 0.1 Wood 13 Under Attic (Unvented) WIC 2 20 Blown 56 ft2 0.1 Wood 14 Under Attic(Unvented) Media 20 Blown 12 ft2 0.1 Wood _ 15 Under Attic (Unvented) Office 20 Blown 132 ft2 0.1 Wood 16 Under Attic (Unvented) Foyer 20 Blown 100 ft2 0.1 Wood 17 Under Attic (Unvented) Laundry 20 Blown 126 ft2 0.1 Wood 18 Under Attic (Unvented) Pantry 20 Blown 42 ft2 0.1 Wood 19 Under Attic (Unvented) Powder 20 Blown 30 ft2 0.1 Wood 20 Under Attic (Unvented) Hall 20 Blown 116 ft2 0.1 Wood 21 Under Attic (Unvented) Garage Entry 20 Blown 66 ft2 0.1 Wood 22 Under Attic (Unvented) Toilet 20 Blown 22 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 S Exterior Concrete Block - Int InsuBedroom 3 13.1 13 0 10 0 130.0 ft2 0 0 0.6 0 _ 2 W Exterior Concrete Block - Int InsuBedroom 3 13.1 17 0 10 0 170.0 ft2 0 0 0.6 0 _ 3 S Exterior Concrete Block- Int Insul WIC 4 13.1 6 0 10 0 60.0 ft2 0 0 0.6 0 -4 S Exterior Concrete Block - Int Insul WIC 3 13.1 6 0 10 0 60.0 ft2 0 0 0.6 0 _ 5 S Exterior Concrete Block - Int InsuBedroom 2 13.1 14 0 10 0 140.0 ft2 0 0 0.6 0 _ 6 S Exterior Concrete Block - Int Ins®ports Room 13.1 12 0 10 0 120.0 ft2 0 0 0.6 0 -7 N Exterior Concrete Block-Int Insul Dining 13.1 11 0 10 0 110.0112 0 0 0.6 0 _ 8 W Exterior Concrete Block - Int Insul Dining 13.1 15 0 10 0 150.0 ft2 0 0 0.6 0 _ 9 W Exterior Concrete Block - Int Insdliving Room 13.1 11 5 12 4 140.8 ft2 0 0 0.6 0 10 N Exterior Concrete Block - Int lnsMaster Bedro 13.1 18 0 11 0 198.0 ft2 0 0 0.6 0 _ 11 W Exterior Concrete Block - Int lnsMaster Bedro 13.1 17 0 11 0 187.0 ft2 0 0 0.6 0 _ 12 N Exterior Concrete Block - Int Insul WIC 1 13.1 12 0 10 0 120.0 ft2 0 0 0.6 0 _ 13 N Exterior Concrete Block - Int InsMMaster Bath 13.1 12 0 10 0 120.0 ft2 0 0 0.6 0 _ 14 E Exterior Concrete Block - Int InsWaster Bath 13.1 11 0 10 0 110.0 ft2 0 0 0.6 0 15 S Exterior Concrete Block- Int InsMMaster Bath 13.1 2 0 10 0 20.0 ft' 0 0 0.6 0 16 E Exterior Concrete Block - Int Insul Office 13.1 11 0 10 0 110.0 ft2 0 0 0.6 0 17 E Exterior Concrete Block - Int Insul Foyer 13.1 6 0 10 0 60.0 ft2 0 0 0.6 0 18 N Exterior Concrete Block - Int Insul Laundry 13.1 4 0 10 0 40.0 ft2 0 0 0.6 0 4/7/2019 6:37 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 19 E Exterior Concrete Block - Int Insul Laundry 13.1 3 0 10 0 30.0 ft2 0 0 0.6 0 20 E Exterior Concrete Block - Int Insul Toilet 13.1 6 0 10 0 60.0 112 0 0 0.6 0 21 S Exterior Concrete Block - Int Insul Toilet 13.1 4 0 10 0 40.0 ft2 0 0 0.6 0 22 N Garage Frame -Wood Sports Room 11 12 10 120.0 ft2 0 0.25 0.600000 0 23 N Garage Frame - Wood Garage Entry 11 6 10 60.0 ft2 0 0.25 0.600000 0 24 N Garage Frame - Wood Laundry 11 9 10 90.0 ft2 0 0.25 0.600000 0 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Vinyl Low-E Double Yes 0.4 0.2 N 8.0 ft2 2 ft 0 in 1 ft 4 in None None 2 W 2 Vinyl Low-E Double Yes 0.4 0.2 N 30.0 ft2 2 it 0 in 1 ft 4 in None None 3 S 5 Vinyl Low-E Double Yes 0.4 0.2 N 12.0 ft2 2 It 0 in 1 ft 4 in None None 4 S 6 Vinyl Low-E Double Yes 0.4 0.2 N 10.0 ft' 2 ft 0 in 1 ft 4 in None None 5 N 7 Vinyl LowaE Double Yes 0.4 0.2 N 30.0 112 2 It 0 in 1 ft 4 in None None 6 W 8 Vinyl Low-E Double Yes 0.4 0.2 N 30.0 ft2 2 ft 0 in 1 It 4 in None None 7 W 9 Vinyl Low-E Double Yes 0.4 0.25 N 48.0 ft2 10 It 0 in 1 ft 4 in None None 8 N 10 Vinyl Low-E Double Yes 0.4 0.2 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 9 W 11 Vinyl Low-E Double Yes 0.4 0.2 N 48.0 ft2 10 It 0 in 1 ft 4 in None None 10 N 13 Vinyl Low-E Double Yes 0.4 0.2 N 20.0 ft' 2 It 0 in 1 ft 4 in None None 11 E 14 Vinyl Low-E Double Yes 0.4 0.2 N 8.2 ft2 2 ft 0 in 1 ft 4 in None None _ 12 E 14 Vinyl Low-E Double Yes 0.4 0.2 N 10.0 ft2 2 It 0 in 1 ft 4 in None None 13 E 16 Vinyl Low-E Double Yes 0.4 0.2 N 20.0 IF 6 It 0 in 1 ft 4 in None None 14 E 17 Vinyl Low-E Double Yes 0.4 0.25 N 28.0 ft' 6 ft 0 in 1 ft 4 in None None 15 E 19 Vinyl Low�E Double Yes 0.4 0.2 N 10.0 ft' 6 ft 0 in 1 ft 4 in None None 16 E 20 Vinyl Low-E Double Yes 0.4 0.2 N 10.0 ft2 2 ft 0 in 1 it 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 676 ft2 676 ft2 28 ft l o ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000464 3430.3 188.32 354.16 .3641 7 07/2019 6:37 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBlu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 17 48 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Exterior 0.6 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS _ / —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Coal 1 Attic 6 140 ft' Attic 40 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre T]hermostar[t:']Y Ceiling Fans: Heating ((�] Jan Feb LXl Mar f ] [ ] Apr [ r f I May rl Jun [x� Jul [X [ Aug [X] [ ]Sep [ ] Q Oct H Venting I I l l Jan I 1 Feb l[�X1 Mar l l Ix] [ I Jun I Jul I Aug I ] Sep lxl Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 76 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/7/2019 6:37 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 Bedroom 3 Default(8 lbs/sq.ft. ft2 ft 0.3 WIC4 Default(8 lbs/sq.ft. ft2 ft 0.3 WIC 3 Default(8 lbslsq.ft. ft2 ft 0.3 Bathroom Default(8 lbs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 lbs/sq.ft. ft2 ft 0.3 Sports Room Default(8 lbs/sq.ft. ft2 ft 0.3 Dining Default(8 lbs/sq.ft. ft2 ft 0.3 Kitchen Default(8 lbs/sq.ft. ft2 ft 0.3 Wing Room Default(8 lbs/sq.ft. ft2 ft 0.3 Master Bedroom Default(8 lbs/sq.ft. ft2 ft 0.3 WIC 1 Default(S lbs/sq.ft. ft2 ft 0.3 Master Bath Default(S Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 lbslsq.ft. ft2 ft 0.3 Media Defaull(8 lbs/sq.ft. ft2 ft 0.3 Office Default(8 lbs/sq.ft. ft2 ft 0.3 Foyer Default(8 lbs/sq.ft. ft2 ft 0.3 Laundry Default(8 lbs/sq.ft. ft2 ft 0.3 Pantry Default(8 lbs/sq.ft. ft2 ft 0.3 Powder Default(8 lbs/sq.ft. ft2 ft 0.3 Hall Default(8 lbs/sq.ft. ft2 ft 0.3 Garage Entry Default 8lbs/s .ft. ft2 ft 0.3 Toilet Name: Signature: 1 f M /IAxW A JL L'Y Rating Compant: Date: to 1 4/7/2019 6:37 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 7 of 7 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Hinkle Residence Builder Name: Street: 7405 Silver Oak Drive Permit Office: St. Lucie County City, Slate, Zip: Port St. Lucie , FL , 34952 Permit Number: Y U Owner: Hinkle Residence Jurisdiction: St. Lucie County W x Design Location: FL, Fart Pierce ci COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceilinglattic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfioor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall he provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall, thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind n'nina an wirina Showerltub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a mannerthat is recommended by the manufacturer. I Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or cellinas a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 477/2019 6:38 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 81 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 48.0 a) Split system SEER 17.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2818 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor.(weighted average) 7a. 0.400 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.211 14. Heating system: Capacity 34.0 c) Area 7c. 352.2 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor.(weighted average) Be. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 16. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Gas fired, natural gas EF 0.60 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 13.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1061. 11.0 2. Masonry (Insulation R-value) 1062. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11a. 20.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code cqmPI'Mi_ s. Builder Address of New Home: 7405 Silver Oak Drive City/FL Zip: Port St. Lucie, FL 34952 4/7/2019 6:38:03 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1