HomeMy WebLinkAboutSet-Up Manualf�
k
INCLUDES:
• True Power'" Electrical Technology
• Two Line LCD Multilingual Digital
Evolution'" Controller (English/Spanish/
French/Portuguese)
• Two Transfer Switch Options Available:
100 Amp, 16 Circuit Switch or
200 Amp Service Rated Smart Switch.
See Page 4 for Details.
• Electronic Governor
• System Status & Maintenance Interval LED
Indicators
• Sound Attenuated Enclosure
• Flexible Fuel Line Connector
WWI
GUARDIAN° SERIES
Residential Standby Generators
Air -Cooled Gas Engine
Standby Power Rating
Models GOO7O36-0, GOO7O37-0 (Aluminum - Bisque) - 16 kW 60 Hz
Model GOO7O35-0 (Aluminur - Bisque) - 16 kW 60 Hz
Models GOO7O39-0, GOO7O38-0 (Aluminum - Bisque) - 20 kW 60 Hz
Models GOO7O43-0, GOO7O42-0 (Aluminum - Bisque) - 22 kW 60 Hz
ST.LUCIE
PLAN R
• Direct -To -Dirt Composite Mounting Pad DATE: I —
PLUMB:
• Natural Gas or LP Gas Operation
DATE: C . L US Q I ff T, -
• 5 Year Limited Warranty LISTER lXV GTTL
MECH:
—:haCUL codification only applies to unbundled units and units packaged with
• Capability to be installed within 18" (457 mm) DATE, pre -wired switches. Units packaged with the Smart Switch are UL certified in the
of a building* Only if located away from doors, windows and fresh air intakes,
and unless otherwise directed by local codes.
FEATURES
O INNOVATIVE ENGINE DESIGN S RIGOROUS TESTING are at the heart of Generac's O
success In providing the most reliable generators possible. Generac's G-Force engine
lineup offers added peace of mind and reliability for when you need it the most. The
G-Force series engines are purpose built and designed to handle the rigors of
extended run times in high temperatures and extreme operating conditions.
O TRUE POWER' ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O
form produce less than 5%Total Harmonic Distortion for utility quality power. This allows
confident operation of sensitive electronic equipment and micro -chip based appliances,
such as variable speed HVAC systems.
SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION:
This state-of-the-art power maximizing regulation system is standard on
all Generac models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque -matching the surge loads to the engine. Digital
voltage regulation at ±1%.
SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer
network provides parts and service know-how for the entire unit, from the
engine to the smallest electronic component.
O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are
V PROTOTYPETESTED V NEMA MGi-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this
V SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer
systems and controls for total system compatibility.
Lu GENERAC
®' Q�
PROMISE * Mobile
� Link
�MRPfl' 9flRP
Bunt In IMY.G uLnO mmmlk aM larepn O V Y.
GENERAC®
16/20/22 kW
features and benefits
Engine
• GeneracG-Force design
Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinderwallsand plasma moly rings helps the engine
run cooler, reducing oil consumption resulting in longer engine life.
• "Spiny-lok" cast iron cylinder walls
Rigid construction and added durability provide long engine life.
• Electronic ignition/spark advance
These features combine to assure smooth, quick starting every time.
• Full pressure lubrication system
Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur-
ing up to a 2 year/200 hour oil change interval.
• Low oil pressure shutdown system
Shutdown protection prevents catastrophic engine damage due to low oil.
• High temperature shutdown
Prevents damage due to overheating.
Generator
• Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
• Skewed stator Produces a smooth output waveform for compatibility with electronic equipment.
• Displaced phase excitation Maximizes motor starting capability.
• Automatic voltage regulation Regulates the output voltage to±l%prevents damaging voltage spikes.
• UL2200listed For your safety.
Transfer Switch (if applicable)
• Fully automalic Transfers your vital electrical loads to the energized source of power.
• NEMA 3R Can he installed inside or outside for maximum flexibility.
• Remote mounting Mounts near your existing distribution panel for simple, low-cost installation.
EvolutionT' Controls
•
Auto/Manual/Off illuminated buttons
•
Two-line LCD multilingual display
•
Sealed, raised buttons
•
Utility voltage sensing
•
Generator voltage sensing
•
Utility interrupt delay
• Engine warm-up
• Engine cool -down
• Programmable exercise
• Smart battery charger
• Main line circuit breaker
• Electronic governor
Unit
• SAE weather protective enclosure
• Enclosed critical grade muffler
• Small, compact, atractive
Installation System
• 1 It (305 mm) flexible fuel line connector
• Direct -to -dirt composite mounting pad
0 Integral sediment trap
Selects the operating mode and provides easy, at -a -glance status indication in any condition.
Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
Smooth, weather -resistant user interface for programming and operations.
Constantly monitors utility voltage, setpoints 65% dropout, 80%pick-up, of standard voltage.
Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a
qualified dealer.
Ensures engine is ready to assume the load, setpoint approximately 5 seconds.
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every
other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel
costs to the owner.
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM -style batteries.
Protects generator from overload.
Maintains constant 60 Hz frequency.
Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150
mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat-
ically applied textured epoxy paint for added durability.
Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
Makes for an easy, eye appealing installation, as close as 18' away from a building.
Absorbs any generator vibration when connected to rigid pipe.
Complex lattice design prevents settling or sinking of the generator system.
Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life.
16/20/22 kW
GENERAC''
specifications.
Generator
Model G007035.0, 13007035-0, G007033-0, G007039-0 G007042-0, G007043-0
Engine
Type of Engine GENEAAC G-Force 1000 Series GENEAAC G-Force 1000 Series GENEHAC G-Farce 1000 Series
uisplacemem 999 cc 999 cc 999 cc
"Smnd lerelsuetemn hour Ihefm9oflhegenemNr.Smnd levels term from other sldesofMe gmemormaybehigher depending an msNlladmpammeters flalmg de5ni6om-Slandby Applimble"pymg emgmcypoaerfortheduretim
of Neutigypoaa ge.NaamloadcabilhyisarailablefaM!smtng. (Nlratingsinamordmoa BS5514,IS03046mdNIN6271).- Marimumdlowllampsand omentane sbjeclro and hatred bystch hclorsat Nei BtWmegamle
mmem,ambiemNmpereNre, ahgude, engine pomm and condition, etc Madmum paver deamsesabout 35 pememfor each 1.000 fee (304.8 meters) ab. saa 1.1; and 0. Wit demseebout 1 pmcentfor each VC (10-F)abow 1B-C(61)-n.
GENERAC®
16/20/22 kW switch options
Limited Circuits Switch Features
• 16 circuits.
• Electrically operated, mechanically -held contacts for fast, positive
connections
• Rated for all classes of Ioad,100% equipment rated, both inductive and
resistive.
• 2 pole, 250 VAC contactors.
• 30 millisecond transfer time.
• Dual coil design.
• Rated for both copper and aluminum conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor
mounting flexibility.
• Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from
Siemens, Murray, Eaton and Square D for the most flexible and cost effec-
tive install.
Dimensions
200 Amps 120/240, 1e
Open Transition Service Rated
Height
Width
H1
H2
W1
LV2
Depth
in
27.24
30.0
11.4
13.5
7.09
min
692.0
762.4
289.0
1 343.0
180.0
Note: The 50 amp switch is flush mountable. HI and W1 refer to mounting hole spacing.
H2 and W2 are cover dimensions. H3 and W3 are the enclosure dimensions without cover.
Wire Ranges
Conductor Lug
Neutral Lug
Ground Lug
1/0-#14
210-#14
210-#14
Service Rated Smart Switch Features
• Includes Digital Power Management Technology standard (DPM).
• Intelligently manages up to four air conditioner loads with no additional
hardware.
• Up to four more large (240 VAC) loads can be managed when used in
conjunction with Smart Management Modules (SMMs).
• Electrically operated, mechanically -held contacts for fast, clean connections.
• Rated for all classes of load,100% equipment rated, both inductive and resis-
tive.
• Up to four more large (120/240 VAC) loads can be managed when used in con-
junction with 50 amp Power Management Modules (PMM**).
• 2 pole, 250 VAC contactors.
• Service equipment rated, dual coil design.
• Rated for both aluminum and copper conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA/UL 313 aluminum outdoor enclosure allows for indoor or outdoor mount-
ing flexibility.
Dimensions
200 Amps 120/240, 1e
Open Transition Service Rated
Height
Width
H1
H2
Wit
W2
Depth
in
27.24
30.0
11.4
13.5
7.09
mm
692.0
762.4
289.0
343.0
180.0
r�Model G007036-0 (16kM
i Er,07�,:,iy : „Oiu.,sar..s iCMo.
O j�w�']
Current
p�Rating(Amps)100 t�.R
ieUttiility Voltage Monitor(Fixed)* U
-Pick-up 80%
-Drapcut 65%
Exerciser bi-weady for 12 minutes*1 Standard
'GNtt d?4,I _ .�k W ;Uran tee � # R
Total of Pre -wired Circuits 16
No. 15A 120V 5
No. 20 A 120 V 5
No. 20 A 240 V 1
No. 30 A 240 V
No. 40 A 240 V 1
� No. 50 A 240 V 1
f"°h9AA'1}lrea''z ;u,tt c"i'r M09S'a:`�'
Circuit Breaker Protected
Available RMS Symmetrical 10,000
Fault Current @ 250 Volts
*Function of Evolution Controller
Exercise can be set to weekly or monthly
Model G007037-0 (16 kW)/GC07039-0 (20 kW)/
G007043.0(22 kW)
NO•a'"aru.'s ,aj,` :::,.n, .,;.>t§ =gr .:.:,:II".
Current Rating (Amps) gn 200
k 0y A ': Mt 1{ of 9
Utility Voltage Monitor (Fixed)*
-Pick-up 80%
-Dmpoul 65%
2-st: yy,1E• q 4a a2 a I d r , h9R cf }
Exerciser qweekly for 12 minutes* Standard
Enclosure Type NEMANL 3R
Lug Range -^250 MCM - #6
*Function of Evolution Controller
16/20/22 kW
GENERAC
available accessories
h;`�... 1, '.[ �vJak,:'S'
ITR ,e. t., .. ,r
idiL:Latl:i .,�. .. �a .Geri, iellati •� ,..gz -,q. ..
Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac
G006463-4
Mobile Link" cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or
text message when a change in the generator's status occurs. Available In the U.S. only.
G005819.0
26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet
cell battery for use with all air-cooled standby product (excluding PowerPact®).
G007101.0
Battery Pad Warmer The pad warmer rests under the battery. Recommended for use if the temperature regularly falls below 0°F.
(Not necessary for use with AGM -style batteries).
G007102-8
Oil Warmer Oil wanner slips directly over the oil filter. Recommended for use 0 the temperature regularly falls below
01
G007103-0
Breather Wanner The breather warmer Is for use in extreme cold weather applications. For use with Evolution controllers
only in climates where heavy icing occurs.
G005621-0
Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load
Contact Kit you may not need. Not compatible with 50 amp pre -wired switches.
Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a
r pK
Fascia Baserd
G007027-0 - Bisque
sleek, contoured appearance as well as offering protection from rodents and insects by covering the Ili
on
(Standholes
located in the base.
If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from
G005703-0 - Bisque
Paint Kit future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator
enclosure.
G0064B5-0
Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine
maintenance on a Generate automatic standby generator.
G006873-0
Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its
Smart Management Module
power management capabilities. It provides additional power management flexibility not found in any other
(50 Amps)
power management system.
dimensions & UPCs
Dimenslons shown are approximate. Refer to installation manual for eract dimensions DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
Model
UPC
G007035-0
696471070354
G007036-0
696471070361
G007037-0
696471070378
G007038-0
696471070385
G007039-0
696471070392
G007042-0
696471070422
G007043-0
696471070439
re VuUav
GEN ERAC® Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI53189 • generac.com
@2016 Generate Power Systems, Inc. All Aphis reserved. All specifications are subject to change wiih0ut notice. Para No. 10000000194-C 08/18/16
^' 6ENEMTOR � � i
PAD
THICK M
PAD DIMENSIONS:
AMERICAST GENERATOR CONCRETE PAD\�
(ON -GRADE APPLICATIONS ONLY) WIND DESIGN REOUIREMENTS;
ISONE(PJC VIFVi
GENERATORTASLE:
r
�
{
GENERATOR UNIT BY +
'
5EPARAre SUBMMAL
.;
(SEE SCHEDULE FOR I
MINIMUM welQu
^ i
REIZuiR )
j
-Sf'IFNatN--.
ML _Y
<DNGQE I�p•-�
R04DX011� `\ X+SIFNA�B W��1R.��-.i 3•Mp .i.0 MIM
.rj+l•wx.'
k�so•_.-_r.
AIL( FIPDSURE
A1514. 'EIIPp$IIRE
AISY. 1MP0351Af
CAM
R P D
R: -c I Lor
.6lol! C2: T.
P: BFAOI
:ImMPN 30:0{Pd 364tM
ImMPN 3909PoE N.OEPG
300MpN <3d3 P4133:14Pd
BADWAAD
f36MPN 3E 9SPf13945 Pd
I]OMPN 39pBPd q)Adp#3m
MPN {381 Pd 43.i9At
MWA-0ADE
I65MPN 3683Pil d169 P5f.
I]s MPM {l.{3Pd W38 FfE
186MPX b'.&IP4:S6HIP4
Rwxosmoom cABAQSY
mam
EExDm�15EWli
wE,wr
,..9nb[
r�.<°£
� NrAMSMS
Gmncrosnlams023 llf4W
$Sm•
d0M•'
aW D.,
.i1A3Al
:Fv cnsMWa0MMm
G�YrCm5810 n RE- 30[W
'35m•
0m
U.m'! {n
M'M
LK[30¢MRIa035¢WM
:
6eeMC8159 N61.G63 mt]V
SS[0^
q8.m
39 m'. SI3N
1]Y Bile..
Gemx�a3 I¢[W
� BSM•
4m•
IDm• i:.MObf
4>.MA3
6wnac00F010amsms unv.-k90.
48M�
]sm`626f
{].BOM
ll[Sv
um•
qD W'
bm•L.4318f
{]MAS
5'.mEn4amsm6
GeMrltmMrSamSm] iOYW
1im•
w65'
X.m• 451p
{I.NM
GRarx0�N3AD1D ffi[SY.fmro'
q
34m^I..'
Geara[mSSS5am%16551' U.�ED3'
m•
NM.
R9WI.SA®f
Q.MM'.
[M4^t{BSSISOp -t61D RN
]bm•
E8O3 •'
3Rm' SmRf
[l.4[Bd
GS4mUGFam33SGE 33M
�35 W'
94d0•
39iA'I.. SW2f
m.m BC
C90MMBO15¢41M1
¢Om101I5[w 6ria
r3uD'
Eam•
�,m[ b40.
[SBi 31.
QBcvOMtW aD15¢4PN
c[of03ta 3TAW 1]Kvl
nm-
qam'
30.58' Wlpf
43f3
SN3m[agm3YGE -N [W'33W'
BXBgbStlrtm 3430 mm
31W'
40m•..
nm•
30.5R•.'. YOPf
#m^14306f
4303AE-.
9383 AI:.
..
0:166YSVntmIDmID13i pqy.
R15•
SDm`
'3Ib3• 50]0f
4S43A5
lmc3RMNADl..
aSXaMn W1ID11 15
3i]5'
UW
3.glo Pl
43d3A5
dPC1811MM(O3YMM
Ol.BpnSlnnmOW3013 m[W�
33 J5!
9AV
31 W` SNb
M:mAI
e(ygasYenwawwsl ]D[W
33.R'
4Am
B m• nom
um0n
GEMtmmRBN1¢, m33 u[w
zs.m•
.A6o
.xm^ 4o51M
4].Mnr
..
CIB¢MT16 D356 WX
GeMlss nTmOaCNm9 1D[W
iS.m•
40m'•:)91M•
aybf
nA0A5
cwRmlBan m3 aue
9sm`
mm-'.19m-.
u¢mf
a<{vi5.
GENERATOR MOUNTING CONFIGURATION:
i EXEMRoR
A ISEEmxGEmwD
� spEENE EDR
Da.•hnw9svauwr
ucuaem
i3EFWWTN- 59`IE1IGTI----?
:SYi: =°SPR l
7v`sED Dx � ]a9 • XAaw d3w5nc woe s5xm'EDSSloii tloiiit
ATfiPADEQ6N..NPM00
UQiWRFD`33Q1 WpO SFEFll WR• 106 nqh
NOxWY. DESIGn WIXOSPEED Vry0 � EIC nQJI
0.6CLAl[LDBY•ID Ix1FANAlpXESSVRECGEE•NJA
FYpU9R(PG]EfiDRY •D wIHO OIAEC]SOb4315Y F4C1OR X¢�DdO
EXQD3V11EGlEldM.R/A XESWRN •AT4RDVIID
GVSTEEEEYI FACTOR eDAF PRESSVBEAi }IF6MNRM1�TRS¢IN/w
FORE WEESSaEXSiI: Yd{
WINDPRESSURE
P=wsys6.BDIeM1�ASD)
GENERAL NOTES
L ILLS S45TEM{VS BEFN DPSIGnEDAN05NPLLBE FABRIGiEL
MAIXDRDRNCE WfIX YXBP.EQIYBEXEHf50FTNEFIDaw
6Th{pM6C0EE51RM EDRZOX (iD11}
1 11E(IUFAED YR�o 1MD DE3[GY PeEs5YPE5 GLp6/JE9 WR
1
ANCHOR TO PAD SCHEDULE: a
ivcs54Am aesevmow
S.
fDXCRETE:l I3FkT'D TDF]IND :'
(lml 3 33R14roAiLLEN�D.
i4lDXGQF.�rNlll' ].
- EBGE D6S.3ME 6' �,
4DM A�^-XD.a 1
L N:p04Q14NRh'PEfllM:050E
i. ExOPD:tE4lMGEDRDEST4p[P y.
GaDo¢s33�xFsss
z isu¢awiufiEDclvmu+cE
G Etr51N.E 1DMI�M SI54MNGN�.
RNYMISLEtR.4t1[11¢45..•
6. DVNTXM1tlWCNRE0.5'.
35mAlunwers3vanm+sro
1 wauARGou. lo.
mxEGRaR
:f]Ao1xEn5 Bose. 1
vAMRs rrnx NmEl
£EEGFeieuToazpSo
sDlpsD mEx xD •� 'L.
E AxaoxsaEExd
avisznAclob-/
Row MFsx /
wSEs: F� dRE
E: Y.vlsruss DFBemwcFRF+umR'e4s�.1xX,lx,mtssmwr.
9: [DEs]Ax¢rc4axvrm ettETDw.
AD55]4RRDPlf4'U ON GENFw1D4L5E.V/IED5 w5E5R DiW
M1gnAEMw:ntfl.R'
ALTERED
Aan w+MmaARs,RR1eR.Rnmiswdw3]mxs
m ras000inERTARexarpERXnieawD vmAllw.m
OUP. CEA35FIGl1Ox.
33. ET¢PTASPavPFssFrcPwnDED xeMlu: nd ADDmoxu.
Q3!fIGHIITONS w AFFIaMTmN6 Pa-IKSFNDE➢.
Automatic
Transfer Switches
Description
C,
Service and non -Service rated
Automatic Smart Transfer Switches
100 - 400 Amps, Single Phase
C �L us
LISTED
�a--•
*CUL only applies to non -service rated switches
Generac Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution'" or Nexus'"
Controller. The 100, 200, and 400 amp open transition switches are available in single phase in both service equipment rated and
non -service equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated
equipment configuration.
Standard Features
Service rated (RXSW) Generac Automatic Transfer Switches are housed in an aluminum NEMA/UL Type 311 enclosure*, with
electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for
years of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All
switches are covered by a 5 year limited warranty.
* Non -service rated (RXSC) switches are housed in a steel enclosure.
DPM Technology
Through the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC
controlled) loads with no additional hardware. When used in tandem with Smart Management Modules, up to 8 more loads can be
managed as well, providing the most installation efficient power management options available.
m SU
^ zoo,:
GENERAC'
100-400 Amps, Single Phase Automatic Smart Transfer Switches
Functions
All timing and sensing functions originate in the generator controller
Utilityvoltage drop-out......................................................................................................................................................................................................................<65%
Timer to generator start ..................................................................................................
10 second factory set, adjustable between 2-1500 seconds by a qualified dealer'
Enginewarm up delay.................................................................................................................................................................................................................
5 seconds
Standbyvoltage sensor..................................................................................................................................................................................................
65% for 5 seconds
Utilityvoltage pickup ............................... .................................................................................................................................................
......................................... >80%
Re -transfer time delay...............................................................................................................................................................................................................
15 seconds
Enginecool -down timer............................................................................................................................................................................................................
60 seconds
Exerciser..............................................................................................................................................................5
or 12 minutes adjustable weekly/Ri-weekly/Monthly..
The transfer switch can be operated manually without power applied.
'When used in conjunction with units utilizing Evolution'" controls "Adjustable via the controller
Specifications
Model
RXSC100A3
RXSW1COA3
RXSW150A3
RXSC200A3
RXSW200A3
RXSW300A3
RXSC400A3
RXSW40OA3
Amps
100
100
150
200
200
300
400
400
Voltage
120/240, 1e
120/240, 1e
120/240. 1B
120/240, 1e
120/240, 1e
120/240, 1e
120/240, 1e
120/240. 1e
Wad Transition Type
(Automatic)
Open Transition
Open Transition
Service Rated
Open Transition
Service Rated
Open Transition
Open Transition
Service Rated
Open Transition
Service Rated
Open Transition
Open Transition
Service Rated
Enclosure Type
NEMAAIL 311
NEMAAIL 311
NEMA/UL 311
NEMAAIL 3R
NEMAAIL 3R
NEMAAIL 3R
NEMANL 311
NEMA/l1L 311
UL Rating
UUCUL
UL
UL
UUCUL
UL
UL
UUCUL
UL
Withstand Rating
(Amps)
10,000
10,000
22,000
1 10,000
1 22,000
22,000
22,000
22,000
,Lug Range
1/0-#14
250 MGM-#6
600 MGM -#4 or 1/0-250 MGM
Dimensions
Model
RXSG100A3
RXSW100A3
RXSW150A3
RXSC200A3
RXSW2C0A3
RXSW300A3
RXSC400A3
RXSW400A3
Height
H1
17.24/437.9
17.24/437.9
26.75/679.4
17.24/437.9
26.75/679.4
42.91/1089.9
31.251793.8
42.91/1009.9
(iNmm)
H2
20/508
20/508
30/762
20/508
30p62
48/1219.2
36/914.4
48/1219.2
Width
W1
12.61317.5
12.5/317.5
10.5/266.7
12.5/317.5
10.5/266.7
16.69/423.9
19.181487.2
16.69/423.9
(inlmm)
W2
14.6/370.8
14.6/370.8
13.5/342.9
14.6/370.6
13.5/342.9
21.82/554.2
24/609.6
21,82/554.2
Depth (inlmm)
7.09/180.1
7.09/180.1
6.3/160.1
7.09/100.1
6.31160.1
10.06/255.5
10.06/255.5
10.06/255.5
Weigh (IhsJltllas)
20/9.07
22.5/10.21
39/17.69
20/9.07
39/17.69
140/63.5
133/60.33
140/63.5
PSI
GENERAC Generac Power Systems, Inc. - S45 W29290 HWY.59, Waukesha, WI53189 - generac.com
�'��� 02017 Generac Power Systems,Inc. Alirighisreserved. All specifications are sublectto change without notice. Bulletin10000013459-A 04/24/17