HomeMy WebLinkAboutAtlantic FL17796_R1_II_FL 17796 1.0 Nail Strip 24GA over 15_32 Plywood - 2017 Code RR9/19/2018 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqs%2bbt23mL8HofjKv7zYVGsdytxRV640WTjfC3zOhF3BRA%3d%3d 1/3
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL17796-R1
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Atlantic Metal II of Vero Beach
Address/Phone/Email 4020 43rd Avenue Vero Beach, FL 32960 (772) 257-5730 FLvalidation@yahoo.com
Authorized Signature William Lasky FLvalidation@yahoo.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the
Evaluation Report
LOCKE BOWDEN
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 06/11/2025
Validated By Zachary R. Priest, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence FL17796_R1_COI_FL 17796 1.0 Nail Strip 24GA over 15_32 Plywood -
2017 Code RR.pdf
Referenced Standard and Year (of Standard)Standard Year
TAS 100 1995
TAS 125 2003
TAS110 2000
UL 1897 2012
UL 580 2006
Equivalence of Product Standards Certified By
Sections from the Code
9/19/2018 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqs%2bbt23mL8HofjKv7zYVGsdytxRV640WTjfC3zOhF3BRA%3d%3d 2/3
Product Approval Method Method 1 Option D
Date Submitted 01/24/2018
Date Validated 02/14/2018
Date Pending FBC Approval 02/20/2018
Date Approved 04/10/2018
Summary of Products
FL #Model, Number or Name Description
17796.1 1 1/2" Nail Strip 1 1/2" Nail Strip 15 1/2" Wide over 1/2" Plywood - HVHZ.
Complianr with FBC 2017 6th ed.
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: 78.5 psf @ 11" o.c. -116.0 psf @ 6 1/2" o.c. Install per
manufacturers details. For use in HVHZ Zones.
Installation Instructions FL17796_R1_II_FL 17796 1.5 Nail Strip 24GA over Plywood -
2017 Code RR.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17796_R1_AE_FL 17796 1.5 Nail Strip 24GA over Plywood -
2017 Code RR.pdf Created by Independent Third Party: Yes
17796.2 1 1/2" Snap Lock 1 1/2" Snap Lock 24 Ga. over 16" Wide 1/2" Plywood
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101.0PSF Other: -86.0 psf @ 24" o.c. -108.5 psf @ 12" o.c. -116.0 psf
@ 6" o.c. Install per manufacturers details. For use in HVHZ
Zones.
Installation Instructions FL17796_R1_II_FL 17796 1.5 Snap Lock 24GA SS over
Plywood - 2017 Code RR.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17796_R1_AE_FL 17796 1.5 Snap Lock 24GA SS over
Plywood - 2017 Code RR.pdf Created by Independent Third Party: Yes
17796.3 1" Mechanical Lock 1" Mechanical Lock 0.032" Aluminum 16" Wide over 1/2"
Plywood
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101.0PSF Other: -63.5 psf @ 24" o.c. -101.0 psf @ 6" o.c. Install per
manufacturers details. For use in HVHZ Zones.
Installation Instructions FL17796_R1_II_FL 17796 1.0 Mechanical Lock .032 or .040
Alum - 2017 Code RR.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17796_R1_AE_FL 17796 1.0 Mechanical Lock .032 or .040
Alum - 2017 Code RR.pdf Created by Independent Third Party: Yes
17796.4 1" Nail Strip 1" Nail Strip 24 Ga. 16" Wide over 1/2" Plywood
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +N/A/-153.5PSF Other: -59.75 psf @ 16" o.c. -101.0 psf @ 6 3/4" o.c. -153.5
psf @ 6 3/4" o.c. 12" o.c. Install per manufacturers details. Not
for use in HVHZ Zones.
Installation Instructions FL17796_R1_II_FL 17796 1.0 Nail Strip 24GA over 15_32
Plywood - 2017 Code RR.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17796_R1_AE_FL 17796 1.0 Nail Strip 24GA over 15_32
Plywood - 2017 Code RR.pdf Created by Independent Third Party: Yes
17796.5 1" Snap Lock 1" Snap Lock 24 Ga. 17" Wide 1/2" Plywood
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131.0PSF Other: -67.3 psf @ 24" o.c. -131.0 psf @ 6" o.c. Install per
manufacturers details. For use in HVHZ Zones.
Installation Instructions FL17796_R1_II_FL 17796 1.0 Snap Lock 24GA SS over
Plywood - 2017 Code RR.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17796_R1_AE_FL 17796 1.0 Snap Lock 24GA SS over
Plywood - 2017 Code RR.pdf Created by Independent Third Party: Yes
17796.6 5V Crimp 26 Ga. 5V Crimp Roof Panel over Plywood
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A
Installation Instructions FL17796_R1_II_FL 17796 5V Crimp 24GA or 26GA Min. Thru
Fastened over Plywood - 2017 Code RR.pdf Verified By: Locke Bowden, P.E. 49704
9/19/2018 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqs%2bbt23mL8HofjKv7zYVGsdytxRV640WTjfC3zOhF3BRA%3d%3d 3/3
Design Pressure: +N/A/-156.5PSF Other: -108.5 psf @ 12" o.c. -156.5 psf @ 6" o.c. Install per
manufacturers details. For use in HVHZ Zones.
Created by Independent Third Party: Yes Evaluation Reports FL17796_R1_AE_FL 17796 5V Crimp 24GA or 26GA Min. Thru
Fastened over Plywood - 2017 Code RR.pdf Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
Product Manufacturer: Atlantic Metal II of Vero Beach, Inc.
4310 45th Street
Vero Beach, FL 32966
(772)257-5730
Florida Product Approval #17796 Sub-Category: Metal Roofing Method: 1-0
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant Quality Assurance Program: Keystone Certifications
FBC Sections: 1504.3.2, 1506, 1507.4.3, 1517, 1518.9, 1523.6.5.2.4 Underlayment: See Section 1507, Table 1507.1.1
Non-Structural ApplicationFL 17796 1.5 Nail Strip 24GA Roof Panel Over Plywood HVHZ
24GA steel FOR HVHZ: ASTM A653 G90 FOR NON-HVHZ: ASTM A792 unpainted or painted w/ Valspar Fluropon See Table 1507.4.3(2)
15 ½" Wide
Panel Fastener:
Female Rib: 1 ¼" tall Male Rib: ¾" tall rib w/ slotted strip Panel Seam: Snap Lock
Corrosion Resistant Compliant; ALL to penetrate min. ¼" through plywood Min. 50ksi
Through Panel Slot: (1) #12-11 x 1" tall Pancake Type A In Pan of Panel: (2) #10-11 x 1" Eclipse Head Type A
FOR HVHZ Construction: 19/32" or greater APA Plywood or wood plank. In reroofing applications add 15/32" plywood where roof
is less than 19/32" thick (min. 15/32") the attachment of the decking shall be no less than 8D annual ring shank nails@ 6"o.c.
FOR NON-HVHZ Construction: min. 15/32" APA Plywood over supports at max. 24" o.c.
Fire Barrier: Any approved fire barrier having a current NOA.
**Design Pressure: Panel Slot Fastener Spacing: Panel Pan Fastener Spacing:
-78.S PSF 11"O.C. N/A
-116 PSF 6½"O.C. 12"O.C. -. . - ---- ---· - ----------. . - ---FL 17796 1.5 Snap Lock 24GA Standing Seam Roof Panel Over Plywood Non-Structural Application HVHZ
24GA steel FOR HVHZ: ASTM A653 G90 FOR NON-HVHZ: ASTM A792 unpainted or painted w/ Valspar Fluropon See Table 1507.4.3 (2)
16" Wide Rib: 1 ½" Panel Seam: Snap Lock Roof Panel Clip: 1SOOSNS, Fixed, 18GA, 3 ½" Long
Corrosion Resistant Clip Fastener: (2) #12-11 Pancake Type A to penetrate min.¼" thru plywood.
FOR HVHZ Construction: 19/32" or greater APA Plywood or wood plank. In reroofing applications add 15/32" plywood add 15/32"
plywood where roof is less than 19/32" thick (min. 15/32") the attachment of the decking shall be no less than 8D annual ring
shank nails@6"o.c.
FOR NON-HVHZ Construction: min. 15/32" APA Plywood over supports at max. 24" o.c.
Fire Barrier: Any approved fire barrier having a current NOA.
** Design Pressure: Clip Spacing: Fasteners per Clip:
-86.0 PSF 24"O.C. 2
-108.5 PSF 12"O.C. 2
-116.0 6"O.C. 2 . ' . . . . . . • !il!fflPl'PITTWffiWifJPJWlil'fT¥•11'1'Bl'lrll'\!lltW91iffmt11W't1Hrw·n·-sr,,s:rw·i,,·,r11rW?'f1!1'l!-..mlilll • 032" or .040" Aluminum, 3105 H-24 unpainted or painted with Valspar Fluropon conforming to FBC 2017 6 ed. Min. 22.7 ks!
16" Wide Rib Height: 1" Panel Seam: 180 ° Seam, Double Lock w/ mechanical seamer
Roof Panel Clip: UC-3 Stainless Steel Butterfly Clip Assembly, Two-Piece Slider
Corrosion Resistant Clip Fastener: (2) #U-11 x 1" Pancake Type A to penetrate min.¼" thru plywood
FOR HVHZ Construction: 19/32" or greater APA Plywood or wood plank. In reroofing applications add 15/32" plywood where roof
is less than 19/32" thick (min. 15/32") the attachment of the decking shall be no less than 8D annual ring shank nails@ 6" o.c.
FOR NON-HVHZ Construction: min. 15/32" APA Plywood over supports at max. 24" o.c.
Fire Barrier: Any approved fire bar h 0 rier aving a current N A.
**Design Pressure: Clip Spacing: Fasteners per Clip:
-63.5 PSF 24" o.c.2
-101.0 PSF 6"O.C. 2
FL 17796 1.0 Na il Strip 24GA Roof Panel Over i5/32" Piywo.od -- -Non-Structural Application NON-HVHZ
24GA Steel, conforming to FBC 2017 6111 ed. Yield Strength: Min. 50 ksi
16" Wide Female Rib: 1" tall Male Rib: ¾" tall rib w/ slotted strip Panel Seam: Snap Lock
Panel Fastener: Corrosion Resistant Compliant; ALL to penetrate ¼" min. through plywood
Through Panel Slot: (1) #10-13 x 1" GP Pancake Type A In Pan of Panel: (2) #10-11 x 1" Eclipse Head Type A
Substrate: Min. 15/32" APA Plywood over supports at max. 24" o.c. Min. slope shall comply w/ FBC 2017 6111 ed.
**Design Pressure: Panel Slot Fastener Spacing: Panel Pan Fastener Spacing:
-59.75 PSF 16"O.C. N/A
-101.0 PSF 6¾"O.C. N/A
-153.5 PSF 6 ¾" o.c.12"O.C.
Self-adhered roofing underlayment min. 40 mil thickness.
Min. 50ksi
HVHZ
Min. 50ksi
24GA steel FOR HVHZ: ASTM A653 G90 FOR NON-HVHZ: ASTM A792 unpainted or painted w/ Valspar Fluropon See Table 1507.4.3 (2)
24GA steel FOR HVHZ: ASTM A653 G90 FOR NON-HVHZ: ASTM A792 unpainted or painted w/ Valspar Fluropon See Table 1507.4.3 (2)
Min. 50ksi
ATLANTIC METAL II OF VERO BEACH
1.0 Nail Strip 24GA over Plywood – INSTALLATION DETAILS
ATLANTIC METAL II OF VERO BEACH
1.0 Nail Strip 24GA over Plywood – INSTALLATION DETAILS
FIELD HEMMED PANEL END
ATLANTIC METAL II OF VERO BEACH
1.0 Nail Strip 24GA over Plywood – INSTALLATION DETAILS
HIGH PROFILE RAKE
ATLANTIC METAL II OF VERO BEACH
1.0 Nail Strip 24GA over Plywood – INSTALLATION DETAILS
VALLEY
ATLANTIC METAL II OF VERO BEACH
1.0 Nail Strip 24GA over Plywood – INSTALLATION DETAILS
ATLANTIC METAL II OF VERO BEACH
1.0 Nail Strip 24GA over Plywood – INSTALLATION DETAILS