HomeMy WebLinkAboutLetter
90 MATAWAN ROAD, 5TH FLOOR, MATAWAN, NJ 07747
TEL: (732) 383-2200 KHOV.COM
St. Lucie County Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, Florida 34982
May 15, 2020
Community Name: Waterstone
Location: Fort Pierce, Florida
Plan Name: Lelia ESP - Lot 55
Subject: RE: Permit No. 2003-0746
Dear Mr. Halter:
In response to your review of the above noted permit application and community, please note the following
responses related to the architectural plans in black, italic font.
Issue - Building Review:
Please provide material product approvals, per 107.2 of the Florida Building Code 6th Edition, 2017.
Response: Please refer to the product material approvals included in this resubmission.
Issue - Building Review:
Please provide flame and smoke indices, per R302.9.1, R302.9.2, R302.10.1 and R302.10.2 of the Florida
Building Code 6th Edition, 2017.
Response: Per code sections R302.9.1, R302.9.2, R302.10.1 and R302.10.2 of the FBC 2017, the plan
set has been updated to include flame and smoke indices. Please refer to sheet CS2 for updated
information.
Issue - Building Review:
Please correct “clothes dryer exhaust duct shall not exceed 25 feet” under exhaust fans and venting notes #3 on
sheet CS2 of plan set, per M1602.4.5.1 of the Florida Residential Building Code 6th Edition 2017.
Response: Per code section M1602.4.5.1 of the FBC 2017, the clothes dryer exhaust duct note has
been updated to 35 feet in lieu of 25 feet. Please refer to sheet CS2 for updated information.
Issue - Building Review:
Please label egress door, per R311.2 of the Florida Residential Building Code 6th Edition, 2017.
Response: Per code section R311.2 of the FBC 2017, the front door has been labeled as an egress
door. Please refer to sheet A1.1 for updated information.
90 MATAWAN ROAD, 5TH FLOOR, MATAWAN, NJ 07747
TEL: (732) 383-2200 KHOV.COM
Issue - Building Review:
Please provide column anchor detail from Typ. CMU Column at Lanai/Porch on sheet A5.2 of plan set, per
R407.3 of the Florida Residential Building Code 6th Edition, 2017.
Response: The details located on sheet A5.2 reflect architectural specifications and finishes only.
Please refer to detail 7 on sheet SD-1 of the structural documents for detailed anchoring and
connection related information.
Issue - Building Review:
Please add second lav to plumbing riser diagram for OS Bath, per 107.2 of the Florida Building Code 6th
Edition, 2017.
Response: The plumbing riser diagram has been updated to include a second lavatory in the OS
Bath. Please refer to sheet P1.1 for updated information.
Feel free to contact me should you have any questions or require additional information.
Regards,
Dawn Boggio-Korbelak, RA
Director, Product Development
Florida Architectural License Number: 94880