Loading...
HomeMy WebLinkAboutPLANSSTEPPING STONES JET PUMP COLOR LED LIGHT COLOR LED LIGHT H H H H H H 1 0 f t . H H 4 ft. 3 f t . 4 ft. TILED STEP EDGES TILED BENCH EDGE 1 6 f t . 26 ft. GENERAL NOTES: 1. SWIMMING POOL CONSTRUCTION TO COMPLY W/ FLA. BLDG. CODE AND WITH ALL LOCAL ORDINANCES AND ZONING REGULATIONS. 2. SWIMMING POOL TO BEAR ON ROCK OR UNDISTURBED SAND. ALL WALLS AND FLOORS SHALL BE GUNITED OR POURED IN-PLACE CONCRETE W/ MINIMUM 3,000 P.S.I. CONCRETE (@ 28 DAYS) COMPRESSIVE STRENGTH. 3. ENGINEER SHALL BE NOTIFIED IF SOIL BEARING LESS THAN 2500 P.S.F., OR MUCK, SILT OR LOOSE, SOFT SOIL IS FOUND. A SOIL BEARING CAPACITY OF 2,500 P.S.F. HAS BEEN USED IN THE DESIGN. 4. REINFORCING BARS SHALL BE NEW BILLET, GRADE 40. 5. ALL POOL PIPING TO BE P.V.C. SCHEDULE 40 MIN. AND BEAR THE N.S.F. APPROVAL. 6. BACK-WASH SHALL BE IN COMPLIANCE WITH LOCAL ORDINANCES. 7. DISPOSAL OF POOL WATER SHALL CONFORM TO LOCAL ORDINANCES. SURFACE GRADING SHALL CONTAIN WATER WITHIN PROPERTY LINES. PONDING SHALL NOT PERSIST FOR MORE THAN ONE HOUR. 8. WATER SUPPLY & DISPOSAL SHALL BE INSTALLED SO THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM. 9. GRATE AT MAIN DRAIN SHALL HAVE A FREE AREA OF 4X THE AREA OF THE SUCTION LINE 10. HAIR & LINT STRAINERS SHALL HAVE A REMOVABLE SCREEN W/ A MINIMUM FREE AREA OF 3X THE AREA OF THE SUCTION LINE. 11. ELECTRICAL: INSTALL WIRING & DEVICES AS SHOWN IN "POOL DATA" HEREON. LIGHT CONNECTION TO CONFORM TO NATIONAL ELECTRICAL CODE- LATEST EDITION. 12. ALL METALLIC CONDUITS, PIPING SYSTEMS, REINFORCED STEEL, LIGHT FIXTURES & HOUSING, METAL PARTS OF LADDERS, HANDRAILS, DIVING BOARDS & SUPPORTS TO BE BONDED TOGETHER & GROUNDED TO A COMMON GROUND. BONDING CONDUCTOR SHALL NOT BE SMALLER THAN #8 COPPER. 13. NO OVERHEAD OPEN WIRE OVER POOL WATER. 14. CARTRIDGE FILTER SHALL HAVE A FILTRATION RATE NOT TO EXCEED 3 G.P.M. / S.F. OF FILTER AREA. NO BACK-WASH REQUIRED. 15. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT SITE BEFORE STARTING THE PROJECT. CONTRACTOR SHALL VERIFY LOCATION OF ELECTRICAL SERVICE BY F.P.&L. COMPANY. 16. SPECIAL ATTENTION SHALL BE GIVEN TO EXISTING FOUNDATION TO PREVENT UNDERMINING. MAX. WIDTH MIN. DEPTH 18' SHAPE FILL FROM EXCAVATION TILE FILTER PUMP HP: TIMER LIGHTS TRNFORM: MAIN DRAIN: SKIMMER RETURNS: VALVED VAC LINE DISCHARGE LINE CHLORINATOR HANDRAIL DIVING BOARD HEATER VACUUM HEAD VACUUM HOSE LEAF SKIMMER TREE / STUMP REMOVAL REMOVE EXISITING CONCRETE PUMP POOL PATIO ALUMINUM RAIL FENCE ELECTRICAL POOL PATIO EXISTING PATIO DECK DRAIN GALLON CAPACITY-POOL 18,400 GAL. GALLON CAPACITY-SPA 900 TURN-OVER RATE TERMITE TREAT BARRIER MAX. LENGTH 42' 3.5'MAX. DEPTH 6'+ CUST HAUL ELEVATION T.B.D INTERIOR FINISH GEM CS200 PUMP MAKE PER FBC 4501.20 JANDY FHPM, PHPM POOL SPA 2.0 HP 141 GPM INCL POOL 4 COLOR LED SPA 1 100 WATT POOL 300 WATT SPA POOL 2 SPA 1 (1) POOL 3 SPA 2 JETS:POOL SPA 8 INCL FILL LINE NA TO GROUND TRUCLEAR SALT SYSTEM NA LADDER NA NA SLIDE NA INCL INCL INCL POLE BRUSH TEST KIT INCL INCL INCL NA NA PRINCE THRU OWNER A&G POOLS TRAVERTINE INC 6 hrs INC POOL ALARM NA NA SKIMMER MIN. FLOW 25 GPM SURFACE AREA OF POOL –691 SQ. FT 120 LN FT SPECIFICATIONS 100 WATT MAX. WATER VELOCITY - 6 ft./s FROM TRUNK LINES TO 8 ft./s SUCTION LINES, 10fps MAX RETURN LINE JOB NAME: GATES ADDRESS: 13320 NW BAYWOOD PLACE PERMIT NO.: DATE DRAWN: MAY 11, 2020 DRAWN BY: TRAVIS LEONARD DESIGNER APPROVAL: CHECKED BY:AARON H. ALLEN SCALE: 1/4" = 1' POOLS, INC.CONCRETE THERMEAU S125 ELECTRIC DUAL STAGE HEAT PUMP · APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL 6TH EDITION FILTRATION PUMP COMPLIANT WITH ANSI/APSP/ICC-15 2011 1.65 FHPM VAR 98 GPM Aaron H. Allen PE, FL Reg. No. 86620 FL A. ALLEN ENGINEERING LLC, CA NO. 33042, 2367 7TH STREET, LA VERNE, CA, 91750 TO THE BEST OF MY KNOWLEDGE, THESE DRAWINGS AND SPECIFICATIONS COMPLY MINIMUM BUILDING CODES. F P H J PEQ. LAYOUT S A L T FROM POWER SUPPLY POOL FINISH APPROVED GROUND CLAMP CONTINUOUS BOND WIRE COMMON TO POOL STEEL, RAILS & EQUIPMENT 1" LIGHT CONDUITMINIMUM WATER LEVEL POOL PATIO UNDERWATER LIGHT DETAIL (NO SCALE) 1/4" PER FT. SLOPE 6"X6" TILE INTERIOR FINISH 1 " SAND SET TRAVERTINE POOL PATIO STEEL-TEX FORM OR KRAFT WALL #3 @ 12" O.C.B.W. NOTE: FOR DEPTHS GREATER THAN 6' ADD 1- #3 COVE BAR @ 6" O.C. TO PUMP THREADED PLUG GRATE SHALL BE SECURED IN PLACE SO THAT TOOLS ARE REQUIRED FOR REMOVAL GRAVEL BED NOTE: REMOVE GRATE & WELL POINT PLUG FROM MAIN DRAIN & ATTACH AUX. PUMP LINE WHEN EMPTYING POOL TYPICAL WALL SECTION & WELL POINT (NO SCALE) UNDERWATER LIGHT 1 8 "TO MAIN SERVICE PANEL IN APPROVED CONDUIT (SIZED PER LOAD) WIRING TO POOL LIGHT IN APPROVED CONDUIT UL APPROVED DECK BOX FOR DIRECT CONNECTION TO WET NICHE UNDERWATER LIGHT NOTE: POOL PUMP MOTOR LOCATED ABOVE GRADE. PROVIDE SEPARATE CIRCUIT FOR PUMP MOTOR(S)AND HEATER(S) ETC ELECTRICAL DIAGRAM AND GFI OUTLET PER 2017 NEC (NO SCALE) RAIN TIGHT OUTDOOR ELECTRICAL PANEL (SIZED PER LOAD) APPROVED WIRING IN 1" SCH 40 PVC W/ #8 BONDING CONDUCTOR POOL LIGHT SWITCH EITHER INDOOR OR OUTDOOR G.F.I OUTLET NOTE: INSTALL 125V 15 AMP WEATHERPROOF DUPLEX RECEPTACLE AT LEAST 10' AWAY AND NOT MORE THAN 20' FROM THE INSIDE WALL OF THE POOL · NOTES: · (1) POOL PANEL AND SWITCHES MUST BE AT LEAST 5' FROM THE INSIDE WALL OF THE POOL · · (2) ALL ELECTRICAL WIRING AND EQUIPMENT MUST INSTALLED IN ACCORDANCE WITH THE 2017 EDITION OF THE NATIONAL ELECTRICAL CODE · · (3) PROVIDE PROPER WORKING CLEARANCE SPACES FOR ELECTRICAL EQUIPMENT AS PER HO-26 OF NFPA 70 OUTDOOR TIME-CLOCK PUMP MOTOR RETURN LINE WASTE SKIMMER PIPING SCHEMATIC (NO SCALE) HAIR & LINT CATCHER (COMPONENT OF PUMP) MUST HOLD 35 PSI FOR AT LEAST 30 MIN. PRESSURE GAUGEFILTER PUMP S.P.S.T. TOGGLE SWITCH ELECTRICAL DIAGRAM 1. ALL ELECTRICAL TO COMPLY WITH 2017 NATIONAL ELECTRIC CODE. 2. 3-#12 THHN CU WITHIN ½” MIN. CONDUIT FOR POOL LIGHT (S) 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC, WITH #8 SOLID, BARE COPPER. 4. ALL POOL PUMPS TO GFCI PROTECTED PER NEC 680.22 (B) 5. N.T.S. (1) SPA LIGHT IF APPLICABLE (GFI NOT REQUIRED) #8 SOLID CU GROUND WIRE TO EXISTING PANEL 80 AMP POOL PANEL W/(3) - #6 THHN CU WITHIN 1” ELECTRICAL CONDUIT (4) POOL LIGHT (GFI NOT REQUIRED) 2HP JANDY PLUS HP PUMP MOTOR & 1HP VS FLOPRO PUMP W/BUILT-IN OVERLOAD SWITCH W/3- #10 THHN CU WITHIN ½” MIN. CONDUIT MANUAL MOTOR SWITCH VARIABLE SPEED FLOPRO PUMP MOTOR W/BUILT-IN OVERLOAD SWITCH W/3- #10 THHN CU WITH-IN ½” CONDUIT TIME CLOCK W.P. DISCONNECT HEATER (ELECTRIC HEAT PUMP) 2- #6 THHN, 1#10 GROUND, 1#10 NEUTRAL CU WITHIN 3/4” CONDUIT. (CONNECT TO 50 AMP, 2 POLE GFCI BREAKER W.P. DISCONNECT SALT SYSTEM W/BUILT IN OVERLOAD SWITCH W/3-#10 THHN CU WITH-IN ½” CONDUIT W.L. 18" MIN. ( ENTIRE PERIMETER) #8 SOLID COPPER BOND WIRE W/ APPR. CLAMPS (ONE ON EACH SIDE OF POOL 4 TOTAL ) 8 GAUGE SOLID COPPER WIRE EQUIPOTENTIAL BONDING GRID DETAIL PER N.E.C. 2017 SEC. 680.26 (WHERE ADOPTED) SOIL MINIMUM 18" MAXIMUM 24" FROM EDGE OF POOL AROUND ENTIRE POOL PERIMETER BURIED 4" TO 6" DEEP PAVER DECK OR CONCRETE DECK N.T.S. STEP DETAIL 1. TREAD IS MIN. OF 10" WIDE. 2. RISER NOT GREATER THAN 12" EXCEPT IF MORE THAN (3) TREADS ARE USED. 3. ALL STEPS TO BE SOLID GUNITE 4000 PSI. MISC. NOTES 1. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2X6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY 2. HAND HOLD TO BE INSTALLED AT ARE WHERE DECK RAISED +6" ABOVE POOL N.T.S. 12" MAX. 10" MIN. STEPS #8 GROUND WIRE HANDRAIL BONDING DETAIL WHERE APPLICABLE PER NATIONAL ELECTRICAL CODE 48" MAX WATER DEPTH OUTSIDE ANGLE OF REPOSE 6' AND FURTHER = 4" THICK WALLS W/#3 REBAR @ 12" O.C. EACH WAY 3' TO 6' = 6" THICK WALLS W/#3 REBAR @ 12" O.C. EACH WAY 0' TO 3' = 8" THICK WALLS W/#3 REBAR @ 12" O.C. EACH WAY 4 " w a l l s 6 " 5 f t . 3 ft. 6 ft. 9 ft. 8 " w a l l s EXCAVATION INTO THE ANGLE OF REPOSE IS ALLOWABLE PROVIDED: * SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE SUFFICIENT TO SECURE SOILS FROM EROSION OR SETTLEMENT * NO UNDERMINING OCCURS OR ENGINEER APPROVED IF ANY DOES * COMPACTION TEST OF THE BACKFILLED MARTIAL ARE PROVIDED AT C.O. OF THE SWIMMING POOL A N G L E O F R E P O S E FILTRATION PUMP LOW SPEED FILTRATION PUMP HIGH SPEED BULL NOSE BRICK COPING 6"X6" TILE 4 1/2" TYP. WALL TRAVERTINE PATIO STEEL-TEX FORM OR KRAFT WALL #3 @ 12" O.C.B.W. TO PUMP 6" TYP. FLOOR (1) CHANNEL DRAIN AND GRATE SHALL BE SECURED IN PLACE SO THAT TOOLS ARE REQUIRED FOR REMOVAL GRAVEL BED SPA WALL SECTION (NO SCALE) SPA BENCH 26" BELOW WATER LINE SPA DETAIL (NO SCALE) 42' 0 0 6 FT DEEP 6" THICK WALLS SHALL NOT SLOPE GREATER THAN 11 FLOOR SLOPES FLOOR SLOPES SHALL BE REASONABLY UNIFORM AND COMPLY WITH ARTICLES 5.6.1 THRU 5.6.3 THE SLOPE OF THE FLOOR FROM THE SHALLOW END WALL TOWARDS THE DEEP AREA SHALL NOT EXCEED 1 FOOT IN 7 FOOT #3 STEEL @ 12" O/C E.W. 1' R 6'+ DEEP WATERLINE TILE CYCOLAC MAIN DRAIN 3 FT 6" DEEP SECTION THRU POOL 10' 1 2 I N . 1 2 I N . 1 2 I N .3.5' DEEP UNBLOCKABLE CHANNEL DRAIN SPA DETAIL 8 FPS MAX 2.5" SUCTION LINE TO MAX 117 G.P.M. APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B. ASME/ANSI 112.19.8-2007 3" SUCTION LINE MAX 147 G.P.M. TO JET PUMP TO FILTRATION PUMP8 FPS MAX 2.5" RETURN LINE TO JETS 2.5" RETURN LINE TO FIRST TEE · APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL 6TH EDITION AND THE ANSI/APSP-7 2006 FOR SUCTION ENTRAPMENT AVOIDANCE SWIMOUTS WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE WATERLINE 18" N.T.S. Per F.R.C. 4101.18 AND ANSI/NSPI-5-2003 20" max 18" 30" MIN. CLEARANCE IN FRONT OF SUBPANEL VERIFY EXACT LOCATION IN FIELD WITH SUPERVISOR BURIED POWER LINES *LOCATION OF GFI RECEPTACLE TO BE DETERMINED IN FIELD PER NEC 680 6'+ DEEP 3.5' DEEP STEP R R EXISTING COVERED LANAI AREA HOMEOWNER TO REMOVE PAVERS INSTALL TRAVERTINE TO MATCH POOL DECK CL 14 ft. 40 ft. 4 2 f t . 18 ft. COLOR LED LIGHT COLOR LED LIGHT COLOR LED LIGHT 7 ft. 7 f t . 2 10 ft. SAFETY BARRIER PER FRC 4501.17-4501.17.1.15 & ASTM5034-95, ASTM D3787-89, ASTM 653-96 & R4501.17.1 THRU R4501.17.3 POOL BARRIER PER FRC 4501.17-41.1.17.3 AND ANSI/NSPI-5-1995 5 6 f t . 4 2 f t . 2 f t . 3 ft. 4 f t . 3 4 f t . TILED SPILLWAY T I L E D S P I L L W A Y FILTRATION AND WATER FEATURE PUMP UMBRELLA SLEEVE 1. 2.5" RETURN TO JETS 2. 3" SPA MAIN DRAIN LINE 3. 2" VACUUM LINE 4. 2.5" POOL MAIN DRAIN LINE 5. 2" SKIMMER SUCTION LINE 6. 2.5" SPA RETURN LINE TO FIRST TEE 7. 2" WATER FEATURE BUBBLER RETURN LINE 8. 2.5" POOL RETURN LINE TO FIRST TEE 9. 2.5" SPA MAIN DRAIN LINE 10. WATER BOND 11. 2.5" WATER FEATURE MAIN DRAIN LINE 12. 2.5" RETURN LINE TO FEATURES A. JANDY FLO PRO 1.65 HP VARIABLE SPEED W/APPR HAIR & LINT STRAINER B. 1.5" TO WASTE OR TO GROUND C. CARTRIDGE FILTER W/PRESSURE GAUGE AND AIR RELIEF VALVE D. THERMEAU ELECTRIC HEAT PUMP E. VALVES (TYP) F. JANDY “AQUA-PURE SALT SYSTEM G. JANDY 2HP JET PUMP WITH APPR. HAIR & LINT STRAINER H. JANDY FLO PRO 1.65 HP VARIABLE SPEED W/APPR HAIR AND LINT STRAINER FOR BUBBLERS AND SCUPPER WATER FEATURES LEGEND 11 12 E EQUIPMENT LAYOUT N.T.S. 7 D C F 8 4 6 9 10 A B 3 125 HG DRAIN DETAIL · APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL 6TH EDITION AND THE ANSI/APSP-7 2006 FOR SUCTION ENTRAPMENT AVOIDANCE APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B. ASME/ANSI 112.19.8- 2007 UNBLOCKABLE CHANNEL DRAIN 8 FPS MAX 2.5" SUCTION LINE TO PUMP MAX 117 G.P.M. 2.5" SUCTION LINE MAX 117 G.P.M. 2.5" RETURN LINE TO FIRST TEE 2.5" RETURN LINE TO FIRST TEE WATER FEATURE PUMP TO FILTRATION PUMP VARIABLE SPEED FLOPRO PUMP MOTOR W/BUILT-IN OVERLOAD SWITCH W/3- #10 THHN CU WITH-IN ½” CONDUIT TIME CLOCK W.P. DISCONNECT 1.5"1.5"1.5" 2"2" 1"2.5" 2.5" 1" 1" 1" 1" 2" 1.5"1.5" 2.5" 2.5" 2.5" 3" TRAVERTINE DECKING W P 1.5" HYDROSTATIC RELIEF RAISED TILED WALL +18" WITH (3) SCUPPER WATER FEATURES 1 f t . 4 ft.4 ft. 6 f t . 8 f t . FLOATING POOL ALARM PER NSF CERTIFIED TO ASTM F 2208-08 POOL ALARM FLOATING POOL ALARM PER NSF CERTIFIED TO ASTM F 2208-08 POOL ALARM RS4 1" 48" HIGH MECHANICAL RAIL FENCE ON SEPARATE PERMIT BY PRINCE DEVELOPMENT 2" VAC SKIMMER 2" R R R 1.5" 1.5" 1.5" AUTOFILL AND OVERFLOW 1" 320 SQ FT EQ EQUIPMENT PAD PER FBC 4501.22(9.2) POOL EQUIPMENT ANCHORED PER FLORIDA BUILDING CODE 2017 6TH EDITION ANSI-7/15 REC. PUMP/WATER FEATURE PUMP = 1.65 JANDY VARIABLE SPEED LOW SPEED – 36 GPM MAX HIGH SPEED = 97 GPM @ 22 TDH 3" SUCTION PIPE @ 97 GPM = 4.95 FT/SEC. (8 FT./SEC. MAX. – SUCTION LINES) 3" BRANCH PIPE @ 48 GPM = 2.97 FT./SEC. (6 FT./SEC. MAX. – PRESSURE LINES) 2.5" PRESSURE PIPE @ 97 GPM = 7.18 FT./SEC. (10 FT./SEC. MAX. – PRESSURE LINES) 340 SQ. FT. CARTRIDGE FILTER X 0.375 = 127.50 GPM BACKWASH VALVE NO THERAPY PUMP = 2HP JANDY PHPM JET PUMP LOW SPEED = 36 GPM MAX. HIGH SPEED = 135 GPM @ 50 TDH 3" SUCTION PIPE @ 135 GPM = 5.81 FT./SEC. (8FT./SEC. MAX. – SUCTION LINES) 2.5" PRESSURE PIPE @ 135 GPM = 9.18 FT./SEC. (10 FT./SEC. MAX. – PRESSURE LINES) LOCATION OF WATER BOND BY POOL EQUIPMENT PB-2008 WATER BONDING WIRE TO GRID POOLBOND PB-2008 IN ACCORDANCE WITH 680.2 C POOL WATER SHALL BE IN DIRECT CONTACT WITH AN APPROVED CORROSION-RESISTANT CONDUCTIVE SURFACE THAT EXPOSES NOT LESS THAN 9 INCHES (5800 MM) OF SURFACE AREA TO THE POOL WATER AT ALL TIME. N.T.S SWIMOUTS WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE WATERLINE 18" N.T.S. Per F.R.C. 4101.18 AND ANSI/NSPI- 5-2003 20" max 18" CHANNEL DRAIN INSTALL 125V 15 AMP WEATHERPROOF DUPLEX GFCI RECEPTACLE AT LEAST 10' AWAY AND NOT MORE THAN 20' FROM THE INSIDE WALL OF THE POOL (NO SCALE) (NO SCALE) (NO SCALE)