HomeMy WebLinkAboutPLANSSTEPPING
STONES
JET PUMP
COLOR
LED
LIGHT
COLOR
LED
LIGHT
H
H
H
H
H H
1 0 f t .
H
H
4 ft.
3 f t .
4 ft.
TILED STEP EDGES
TILED BENCH EDGE
1 6 f t .
26 ft.
GENERAL NOTES:
1. SWIMMING POOL CONSTRUCTION TO COMPLY W/ FLA. BLDG. CODE AND WITH ALL LOCAL
ORDINANCES AND ZONING REGULATIONS.
2. SWIMMING POOL TO BEAR ON ROCK OR UNDISTURBED SAND. ALL WALLS AND FLOORS SHALL
BE GUNITED OR POURED IN-PLACE CONCRETE W/ MINIMUM 3,000 P.S.I. CONCRETE (@ 28 DAYS)
COMPRESSIVE STRENGTH.
3. ENGINEER SHALL BE NOTIFIED IF SOIL BEARING LESS THAN 2500 P.S.F., OR MUCK, SILT OR
LOOSE, SOFT SOIL IS FOUND. A SOIL BEARING CAPACITY OF 2,500 P.S.F. HAS BEEN USED IN THE
DESIGN.
4. REINFORCING BARS SHALL BE NEW BILLET, GRADE 40.
5. ALL POOL PIPING TO BE P.V.C. SCHEDULE 40 MIN. AND BEAR THE N.S.F. APPROVAL.
6. BACK-WASH SHALL BE IN COMPLIANCE WITH LOCAL ORDINANCES.
7. DISPOSAL OF POOL WATER SHALL CONFORM TO LOCAL ORDINANCES. SURFACE GRADING
SHALL CONTAIN WATER WITHIN PROPERTY LINES. PONDING SHALL NOT PERSIST FOR MORE THAN
ONE HOUR.
8. WATER SUPPLY & DISPOSAL SHALL BE INSTALLED SO THAT THERE IS NO CROSS CONNECTION
WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM.
9. GRATE AT MAIN DRAIN SHALL HAVE A FREE AREA OF 4X THE AREA OF THE SUCTION LINE
10. HAIR & LINT STRAINERS SHALL HAVE A REMOVABLE SCREEN W/ A MINIMUM FREE AREA OF 3X
THE AREA OF THE SUCTION LINE.
11. ELECTRICAL: INSTALL WIRING & DEVICES AS SHOWN IN "POOL DATA" HEREON. LIGHT
CONNECTION TO CONFORM TO NATIONAL ELECTRICAL CODE- LATEST EDITION.
12. ALL METALLIC CONDUITS, PIPING SYSTEMS, REINFORCED STEEL, LIGHT FIXTURES & HOUSING,
METAL PARTS OF LADDERS, HANDRAILS, DIVING BOARDS & SUPPORTS TO BE BONDED TOGETHER
& GROUNDED TO A COMMON GROUND. BONDING CONDUCTOR SHALL NOT BE SMALLER THAN #8
COPPER.
13. NO OVERHEAD OPEN WIRE OVER POOL WATER.
14. CARTRIDGE FILTER SHALL HAVE A FILTRATION RATE NOT TO EXCEED 3 G.P.M. / S.F. OF FILTER
AREA. NO BACK-WASH REQUIRED.
15. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT SITE BEFORE STARTING
THE PROJECT. CONTRACTOR SHALL VERIFY LOCATION OF ELECTRICAL SERVICE BY F.P.&L.
COMPANY.
16. SPECIAL ATTENTION SHALL BE GIVEN TO EXISTING FOUNDATION TO PREVENT UNDERMINING.
MAX. WIDTH
MIN. DEPTH
18'
SHAPE
FILL FROM EXCAVATION
TILE FILTER
PUMP HP:
TIMER
LIGHTS
TRNFORM:
MAIN DRAIN:
SKIMMER
RETURNS:
VALVED VAC LINE
DISCHARGE LINE
CHLORINATOR
HANDRAIL
DIVING BOARD
HEATER
VACUUM HEAD
VACUUM HOSE
LEAF SKIMMER
TREE / STUMP REMOVAL
REMOVE EXISITING CONCRETE
PUMP POOL PATIO
ALUMINUM RAIL FENCE
ELECTRICAL
POOL PATIO
EXISTING PATIO
DECK DRAIN
GALLON CAPACITY-POOL 18,400 GAL.
GALLON CAPACITY-SPA 900
TURN-OVER RATE
TERMITE TREAT BARRIER
MAX. LENGTH 42'
3.5'MAX. DEPTH 6'+
CUST
HAUL
ELEVATION T.B.D
INTERIOR FINISH GEM CS200
PUMP MAKE PER FBC 4501.20 JANDY FHPM, PHPM
POOL SPA 2.0 HP 141 GPM
INCL
POOL 4 COLOR LED SPA 1 100 WATT
POOL 300 WATT SPA
POOL 2 SPA 1
(1)
POOL 3 SPA 2
JETS:POOL SPA 8
INCL FILL LINE NA
TO GROUND
TRUCLEAR SALT SYSTEM
NA LADDER NA
NA SLIDE NA
INCL
INCL
INCL
POLE
BRUSH
TEST KIT
INCL
INCL
INCL
NA
NA
PRINCE THRU OWNER
A&G POOLS
TRAVERTINE
INC
6 hrs
INC POOL ALARM
NA
NA
SKIMMER MIN. FLOW 25 GPM
SURFACE AREA OF POOL –691 SQ. FT 120 LN FT
SPECIFICATIONS
100 WATT
MAX. WATER VELOCITY - 6 ft./s FROM TRUNK LINES
TO 8 ft./s SUCTION LINES, 10fps MAX RETURN LINE
JOB NAME: GATES
ADDRESS: 13320 NW BAYWOOD PLACE
PERMIT NO.:
DATE DRAWN: MAY 11, 2020
DRAWN BY: TRAVIS LEONARD
DESIGNER APPROVAL:
CHECKED BY:AARON H. ALLEN
SCALE: 1/4" = 1'
POOLS, INC.CONCRETE
THERMEAU S125 ELECTRIC DUAL STAGE HEAT PUMP
· APPROVED WITH THE 2017 FLORIDA BUILDING CODE
FOR RESIDENTIAL 6TH EDITION
FILTRATION PUMP COMPLIANT WITH ANSI/APSP/ICC-15 2011
1.65 FHPM VAR 98 GPM
Aaron H. Allen PE, FL Reg. No. 86620 FL
A. ALLEN ENGINEERING LLC, CA NO. 33042,
2367 7TH STREET, LA VERNE, CA, 91750
TO THE BEST OF MY KNOWLEDGE, THESE DRAWINGS AND
SPECIFICATIONS COMPLY MINIMUM BUILDING CODES.
F
P
H
J
PEQ. LAYOUT
S
A
L
T
FROM
POWER
SUPPLY
POOL FINISH
APPROVED
GROUND CLAMP
CONTINUOUS BOND WIRE
COMMON TO POOL STEEL,
RAILS & EQUIPMENT
1" LIGHT
CONDUITMINIMUM
WATER LEVEL
POOL PATIO
UNDERWATER
LIGHT DETAIL
(NO SCALE)
1/4" PER FT. SLOPE
6"X6" TILE
INTERIOR
FINISH
1 "
SAND SET TRAVERTINE
POOL PATIO
STEEL-TEX FORM
OR KRAFT WALL
#3 @ 12" O.C.B.W.
NOTE: FOR DEPTHS
GREATER THAN 6' ADD 1-
#3 COVE BAR @ 6" O.C.
TO PUMP
THREADED
PLUG
GRATE SHALL
BE SECURED IN
PLACE SO
THAT TOOLS
ARE REQUIRED
FOR REMOVAL
GRAVEL BED
NOTE: REMOVE GRATE &
WELL POINT PLUG FROM MAIN
DRAIN & ATTACH AUX. PUMP
LINE WHEN EMPTYING POOL
TYPICAL WALL
SECTION &
WELL POINT
(NO SCALE)
UNDERWATER
LIGHT
1 8 "TO MAIN SERVICE PANEL IN
APPROVED CONDUIT (SIZED
PER LOAD)
WIRING TO POOL LIGHT IN
APPROVED CONDUIT
UL APPROVED DECK BOX
FOR DIRECT CONNECTION
TO WET NICHE
UNDERWATER
LIGHT
NOTE: POOL PUMP MOTOR LOCATED ABOVE
GRADE. PROVIDE SEPARATE CIRCUIT FOR
PUMP MOTOR(S)AND HEATER(S) ETC
ELECTRICAL DIAGRAM AND GFI
OUTLET PER 2017 NEC
(NO SCALE)
RAIN TIGHT OUTDOOR
ELECTRICAL PANEL
(SIZED PER LOAD)
APPROVED WIRING IN 1"
SCH 40 PVC W/ #8
BONDING CONDUCTOR
POOL LIGHT SWITCH
EITHER INDOOR OR
OUTDOOR
G.F.I
OUTLET
NOTE: INSTALL 125V 15
AMP WEATHERPROOF
DUPLEX RECEPTACLE AT
LEAST 10' AWAY AND
NOT MORE THAN 20'
FROM THE INSIDE WALL
OF THE POOL
· NOTES:
· (1) POOL PANEL AND SWITCHES MUST BE AT
LEAST 5' FROM THE INSIDE WALL OF THE POOL
·
· (2) ALL ELECTRICAL WIRING AND EQUIPMENT
MUST INSTALLED IN ACCORDANCE WITH THE
2017 EDITION OF THE NATIONAL ELECTRICAL
CODE
·
· (3) PROVIDE PROPER WORKING CLEARANCE
SPACES FOR ELECTRICAL EQUIPMENT AS PER
HO-26 OF NFPA 70
OUTDOOR TIME-CLOCK
PUMP
MOTOR
RETURN LINE
WASTE
SKIMMER
PIPING SCHEMATIC
(NO SCALE)
HAIR & LINT
CATCHER
(COMPONENT OF PUMP)
MUST HOLD 35 PSI FOR AT
LEAST 30 MIN.
PRESSURE
GAUGEFILTER
PUMP
S.P.S.T. TOGGLE
SWITCH
ELECTRICAL DIAGRAM
1. ALL ELECTRICAL TO COMPLY WITH 2017 NATIONAL ELECTRIC CODE.
2. 3-#12 THHN CU WITHIN ½” MIN. CONDUIT FOR POOL LIGHT (S)
3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC, WITH #8 SOLID, BARE COPPER.
4. ALL POOL PUMPS TO GFCI PROTECTED PER NEC 680.22 (B)
5.
N.T.S.
(1) SPA LIGHT IF APPLICABLE
(GFI NOT REQUIRED)
#8 SOLID CU GROUND WIRE
TO EXISTING PANEL
80 AMP POOL PANEL
W/(3) - #6 THHN CU WITHIN 1”
ELECTRICAL CONDUIT
(4) POOL LIGHT
(GFI NOT REQUIRED)
2HP JANDY PLUS HP PUMP MOTOR &
1HP VS FLOPRO PUMP W/BUILT-IN
OVERLOAD SWITCH W/3- #10 THHN CU
WITHIN ½” MIN. CONDUIT
MANUAL MOTOR SWITCH
VARIABLE SPEED FLOPRO PUMP MOTOR
W/BUILT-IN OVERLOAD SWITCH W/3- #10
THHN CU WITH-IN ½” CONDUIT
TIME CLOCK
W.P. DISCONNECT
HEATER (ELECTRIC HEAT PUMP)
2- #6 THHN, 1#10 GROUND, 1#10 NEUTRAL CU WITHIN 3/4”
CONDUIT. (CONNECT TO 50 AMP, 2 POLE GFCI BREAKER
W.P. DISCONNECT
SALT SYSTEM W/BUILT IN OVERLOAD
SWITCH W/3-#10 THHN CU WITH-IN ½”
CONDUIT
W.L.
18" MIN.
( ENTIRE PERIMETER)
#8 SOLID COPPER
BOND WIRE W/ APPR.
CLAMPS
(ONE ON EACH SIDE OF
POOL 4 TOTAL )
8 GAUGE SOLID COPPER WIRE
EQUIPOTENTIAL BONDING GRID DETAIL
PER N.E.C. 2017 SEC. 680.26
(WHERE ADOPTED)
SOIL
MINIMUM 18" MAXIMUM 24" FROM EDGE
OF POOL AROUND ENTIRE POOL
PERIMETER BURIED 4" TO 6" DEEP
PAVER DECK OR CONCRETE DECK
N.T.S.
STEP DETAIL
1. TREAD IS MIN. OF 10" WIDE.
2. RISER NOT GREATER THAN 12" EXCEPT IF MORE THAN
(3) TREADS ARE USED.
3. ALL STEPS TO BE SOLID GUNITE 4000 PSI.
MISC. NOTES
1. ALL STEPS AND SWIMOUT BENCH EDGES
WILL HAVE 2X6 CAPTILE BORDER OF OPPOSITE
COLOR OF GEM FINISH FOR VISIBILITY
2. HAND HOLD TO BE INSTALLED AT ARE WHERE
DECK RAISED +6"
ABOVE POOL
N.T.S.
12" MAX.
10" MIN.
STEPS
#8 GROUND WIRE
HANDRAIL BONDING DETAIL
WHERE APPLICABLE
PER NATIONAL ELECTRICAL CODE
48" MAX WATER
DEPTH
OUTSIDE ANGLE OF REPOSE
6' AND FURTHER = 4" THICK WALLS W/#3 REBAR @ 12" O.C. EACH WAY
3' TO 6' = 6" THICK WALLS W/#3 REBAR @ 12" O.C. EACH WAY
0' TO 3' = 8" THICK WALLS W/#3 REBAR @ 12" O.C. EACH WAY
4 " w a l l s
6 "
5 f t .
3 ft.
6 ft.
9 ft.
8 " w a l l s
EXCAVATION INTO THE ANGLE OF REPOSE IS ALLOWABLE PROVIDED:
* SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE
SUFFICIENT TO SECURE SOILS FROM EROSION OR SETTLEMENT
* NO UNDERMINING OCCURS OR ENGINEER APPROVED IF ANY DOES
* COMPACTION TEST OF THE BACKFILLED MARTIAL ARE PROVIDED AT
C.O. OF THE SWIMMING POOL
A N G L E O F R E P O S E
FILTRATION PUMP LOW
SPEED
FILTRATION PUMP
HIGH SPEED
BULL NOSE
BRICK COPING
6"X6" TILE
4 1/2" TYP.
WALL
TRAVERTINE PATIO
STEEL-TEX FORM OR
KRAFT WALL
#3 @ 12" O.C.B.W.
TO PUMP
6" TYP.
FLOOR
(1) CHANNEL
DRAIN AND
GRATE SHALL
BE SECURED IN
PLACE SO THAT
TOOLS ARE
REQUIRED FOR
REMOVAL
GRAVEL BED
SPA WALL
SECTION
(NO SCALE)
SPA BENCH
26" BELOW
WATER LINE
SPA DETAIL
(NO SCALE)
42'
0 0
6 FT DEEP
6" THICK
WALLS SHALL NOT SLOPE
GREATER THAN 11
FLOOR SLOPES
FLOOR SLOPES SHALL BE
REASONABLY UNIFORM AND
COMPLY WITH ARTICLES 5.6.1
THRU 5.6.3
THE SLOPE OF THE FLOOR FROM
THE SHALLOW END WALL
TOWARDS THE DEEP AREA SHALL
NOT EXCEED 1 FOOT IN 7 FOOT
#3 STEEL @ 12" O/C
E.W.
1' R
6'+ DEEP
WATERLINE TILE
CYCOLAC MAIN DRAIN
3 FT 6" DEEP
SECTION THRU POOL
10'
1 2
I N .
1 2
I N .
1 2
I N .3.5'
DEEP
UNBLOCKABLE CHANNEL DRAIN
SPA DETAIL
8 FPS MAX
2.5" SUCTION LINE TO
MAX 117 G.P.M.
APPROVED MAIN DRAIN FRAMES AND
GRATES PER V.G.B. ASME/ANSI 112.19.8-2007
3" SUCTION LINE MAX 147 G.P.M.
TO JET PUMP TO FILTRATION PUMP8 FPS MAX
2.5" RETURN
LINE TO
JETS
2.5" RETURN LINE
TO FIRST TEE
· APPROVED WITH THE 2017 FLORIDA
BUILDING CODE FOR RESIDENTIAL 6TH
EDITION AND THE ANSI/APSP-7 2006 FOR
SUCTION ENTRAPMENT AVOIDANCE
SWIMOUTS WHEN PROVIDED
SHALL BE AT 20"
MAX. BELOW THE
WATERLINE
18"
N.T.S.
Per F.R.C. 4101.18 AND
ANSI/NSPI-5-2003
20" max
18"
30" MIN. CLEARANCE
IN FRONT
OF SUBPANEL
VERIFY EXACT
LOCATION IN
FIELD WITH
SUPERVISOR
BURIED POWER LINES
*LOCATION OF GFI
RECEPTACLE
TO BE DETERMINED IN
FIELD PER NEC 680
6'+ DEEP
3.5' DEEP
STEP
R
R
EXISTING COVERED LANAI AREA
HOMEOWNER TO REMOVE PAVERS
INSTALL TRAVERTINE TO MATCH POOL DECK CL
14 ft.
40 ft.
4 2 f t .
18 ft.
COLOR LED LIGHT
COLOR LED LIGHT
COLOR
LED
LIGHT
7 ft.
7 f t .
2
10 ft.
SAFETY BARRIER PER FRC 4501.17-4501.17.1.15
& ASTM5034-95, ASTM D3787-89, ASTM 653-96
&
R4501.17.1 THRU R4501.17.3
POOL BARRIER PER FRC 4501.17-41.1.17.3 AND
ANSI/NSPI-5-1995
5 6 f t .
4 2 f t .
2 f t .
3 ft.
4 f t .
3 4 f t .
TILED SPILLWAY
T I L E D
S P I L L W A Y
FILTRATION AND WATER
FEATURE PUMP
UMBRELLA
SLEEVE
1. 2.5" RETURN TO JETS
2. 3" SPA MAIN DRAIN LINE
3. 2" VACUUM LINE
4. 2.5" POOL MAIN DRAIN LINE
5. 2" SKIMMER SUCTION LINE
6. 2.5" SPA RETURN LINE TO FIRST TEE
7. 2" WATER FEATURE BUBBLER RETURN LINE
8. 2.5" POOL RETURN LINE TO FIRST TEE
9. 2.5" SPA MAIN DRAIN LINE
10. WATER BOND
11. 2.5" WATER FEATURE MAIN DRAIN LINE
12. 2.5" RETURN LINE TO FEATURES
A. JANDY FLO PRO 1.65 HP VARIABLE SPEED W/APPR HAIR & LINT
STRAINER
B. 1.5" TO WASTE OR TO GROUND
C. CARTRIDGE FILTER W/PRESSURE GAUGE AND AIR RELIEF
VALVE
D. THERMEAU ELECTRIC HEAT PUMP
E. VALVES (TYP)
F. JANDY “AQUA-PURE SALT SYSTEM
G. JANDY 2HP JET PUMP WITH APPR. HAIR & LINT STRAINER
H. JANDY FLO PRO 1.65 HP VARIABLE SPEED W/APPR HAIR AND LINT
STRAINER FOR BUBBLERS AND SCUPPER WATER FEATURES
LEGEND
11 12
E
EQUIPMENT LAYOUT
N.T.S.
7
D
C
F
8
4
6
9
10
A B
3 125
HG
DRAIN DETAIL
· APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR
RESIDENTIAL 6TH EDITION AND THE ANSI/APSP-7 2006 FOR
SUCTION ENTRAPMENT AVOIDANCE
APPROVED MAIN DRAIN FRAMES AND
GRATES PER V.G.B. ASME/ANSI 112.19.8-
2007
UNBLOCKABLE CHANNEL DRAIN
8 FPS MAX
2.5" SUCTION LINE TO PUMP
MAX 117 G.P.M.
2.5" SUCTION LINE MAX 117 G.P.M.
2.5" RETURN LINE TO
FIRST TEE
2.5" RETURN LINE
TO FIRST TEE
WATER FEATURE PUMP TO FILTRATION PUMP
VARIABLE SPEED FLOPRO PUMP MOTOR
W/BUILT-IN OVERLOAD SWITCH W/3- #10
THHN CU WITH-IN ½” CONDUIT
TIME CLOCK
W.P. DISCONNECT
1.5"1.5"1.5"
2"2"
1"2.5"
2.5"
1"
1"
1"
1"
2"
1.5"1.5"
2.5"
2.5"
2.5"
3"
TRAVERTINE
DECKING
W
P
1.5"
HYDROSTATIC
RELIEF
RAISED TILED
WALL +18" WITH (3)
SCUPPER WATER
FEATURES
1 f t .
4 ft.4 ft.
6 f t .
8 f t .
FLOATING POOL ALARM
PER NSF CERTIFIED TO
ASTM F 2208-08
POOL ALARM
FLOATING POOL ALARM PER NSF
CERTIFIED TO ASTM F 2208-08
POOL ALARM
RS4 1"
48" HIGH MECHANICAL
RAIL FENCE ON
SEPARATE PERMIT BY
PRINCE DEVELOPMENT
2"
VAC
SKIMMER 2"
R
R
R
1.5"
1.5"
1.5"
AUTOFILL AND
OVERFLOW 1"
320 SQ FT
EQ
EQUIPMENT
PAD
PER FBC
4501.22(9.2)
POOL
EQUIPMENT
ANCHORED PER
FLORIDA
BUILDING CODE
2017 6TH EDITION
ANSI-7/15
REC. PUMP/WATER FEATURE PUMP = 1.65 JANDY VARIABLE SPEED
LOW SPEED – 36 GPM MAX
HIGH SPEED = 97 GPM @ 22 TDH
3" SUCTION PIPE @ 97 GPM = 4.95 FT/SEC.
(8 FT./SEC. MAX. – SUCTION LINES)
3" BRANCH PIPE @ 48 GPM = 2.97 FT./SEC.
(6 FT./SEC. MAX. – PRESSURE LINES)
2.5" PRESSURE PIPE @ 97 GPM = 7.18 FT./SEC.
(10 FT./SEC. MAX. – PRESSURE LINES)
340 SQ. FT. CARTRIDGE FILTER X 0.375 = 127.50 GPM
BACKWASH VALVE NO
THERAPY PUMP = 2HP JANDY PHPM JET PUMP
LOW SPEED = 36 GPM MAX.
HIGH SPEED = 135 GPM @ 50 TDH
3" SUCTION PIPE @ 135 GPM = 5.81 FT./SEC.
(8FT./SEC. MAX. – SUCTION LINES)
2.5" PRESSURE PIPE @ 135 GPM = 9.18 FT./SEC.
(10 FT./SEC. MAX. – PRESSURE LINES)
LOCATION OF WATER BOND
BY POOL EQUIPMENT
PB-2008
WATER
BONDING
WIRE
TO GRID
POOLBOND PB-2008
IN ACCORDANCE WITH 680.2 C POOL WATER SHALL BE IN DIRECT
CONTACT WITH AN APPROVED CORROSION-RESISTANT
CONDUCTIVE SURFACE THAT EXPOSES NOT LESS THAN 9 INCHES
(5800 MM) OF SURFACE AREA TO THE POOL WATER AT ALL TIME.
N.T.S
SWIMOUTS WHEN PROVIDED SHALL
BE AT 20" MAX. BELOW
THE WATERLINE
18"
N.T.S.
Per F.R.C. 4101.18 AND ANSI/NSPI-
5-2003
20" max
18"
CHANNEL DRAIN
INSTALL 125V 15 AMP WEATHERPROOF DUPLEX GFCI RECEPTACLE AT LEAST 10' AWAY AND
NOT MORE THAN 20' FROM THE INSIDE WALL OF THE POOL
(NO SCALE)
(NO SCALE)
(NO SCALE)