Loading...
HomeMy WebLinkAboutConstruction Plans14.9kW SOLAR ARRAY PLANS W F P 0 PROJECT DESCRIPTION: m O 8fZX79 S FOR 48 MODULES - MISSION SOLAR: MSE310SQ8T GENERA NOTES: 2 INVERTERS - SUNNY BOY: SMA 7.7 WI LLIAM FAGAN THIS IS L CERTIFY THAT F, THE BEST OF MY KNOWLEDGE AND BUILDING THESE PLANS ( A F �411 GOVERNING CODES: WO�Fo� WITHFLORIDAENTTSS AND ADDIHONS. 2017 % , A' Z 2017 FLORIDA PLUMBING CODE, 6TH EDITION DITION 2, ALL PRODUCTS TO BE INSTALLED PER T�S DD 7803 LAKESIDE WAY FILE' Copy 2017 FLORIDA BUILDING RES2017 FLORIDA BUILDING IDENTIAL E, 6TH ECODE, 6TH EDITION MANUFACTURER'S WRITTEN SPECIFICATIONS. 2017 FLORIDA MECHANICAL CODE, 6TH EDITION I, ANDREW D. HALL PE 87479 AN ENGINEER FORT PIERCEFLORIDA�' °' s...li •• FLO R I DA 3 49 51 NEC 2014 LICENSED PURSUANT TO CHAPTER 471, CERTIFY �7 1 NFPA 1 2015 E ECTRICAPCO PONEINTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FBC, FBI x 107. w U 11`( ClV' CJ Wind Design Data o JAN 2 2020 Wind speed 16omph m Risk Category ]I `2 c S-F. Lucie County, Permitting Exposure C ¢ o Gust Factor f0.18 o N "A" Dimension 5.1 ft EAVE Roof Pressure for Components and Cladding Zone 1 21.47 psf -33.75 psf .2 Zone 2 21.47 psf -59.40 psf O M Zone 3 21.47 psf -87.75 psf P ,n J3�o In In�o z v Z w o N1 klh1MM'UN•1 S `k s. 1 LLOJ I r,IiI 3' MR 1YP -' gN w �il3U s M ..��s M. RIDGE ZLu a n ® INVERTER & DISCONNECT Q a IN. 4' CLEARANCE DESTRUCTION T, Z PER NEC 1() H MISSION SOLAR: MSEJIOSQBTOBi (nP) S 0 DRAWING INDEX: :2 U TtP. FAVE w �. 3 S-1 COVER ti MODULE ROOF LAYOUT S-2 ARRAY LAYOUT & DETAILS S-3 ELECTRICAL s Lu S-4 NOTES S-5 SPECIFICATIONS N w S-6 SPECIFICATIONS S-7 SPECIFICATIONS DK NO. S-1 �� •' CEN� !~� No7479 s-10 _ i. �JG`STTATTEOF L 'OADIR -- ���L PV MODULE QMR-UMC FL# 87479 CLIP a 3/8"-16 X 3/4" HEX HEAD BOLT QMR Y 3/8" - 16 FLANGE NUT CROSSRAIL STANDARD U (TYP) QUICK MOUNT PV KIT QUICK MOUNT PV KIT (TYP) QMR I CROSSRAIL STANDARD TYP � U TOP VIEW EXISTING UNDERLAYMENT NTS EXISTING ROOF TRUSS 1/2" PLYWOOD a :2 Z 5/16" DIA SS LAG SCREW M 2-1/2" EMBED MIN. TYPICAL SHINGLE ROOF ATTACHMENT o 3 M in NTS w W O I M k.b N Z N 'ZMd M W yv W z � O d M Z QUICK MOUNT PV KIT 48" MAX O.C.— QMR-UMC CLIP QMR-UEC CLIP (TYP) QMR-UEC (TYP) w a s N M Z W Q Q J V¢ 3 LL W QMR-UMC CUP QMR-RS14 (TYP) QMR-UEC CLIP (TYP) 3 QUICK MOUNT PV KIT (TYP) TYPICAL LAYOUT w o 0 (TYP) MS ' � 5 U a DWG. NO. S-2 (TYP) (TYP) W MISSION SOLAR: MISSION SOLAR: MSE310SQ8T QMR-UMC CLIP MSE310SQ8T (TYP) (TYP) (TYP) z W d NOTES: 1. ALL ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT REPRESENTED IN THIS DOCUMENT SHALL COMPLY WITH THE MANUFACTURERS RECOMMENDATIONS/SPECIFICATIONS AND ALL CODES, STATUES AND STANDARDS ADOPTED BY THE STATE AND THE LOCAL AUTHORITY HAVING JURISDICTION. 2. ALL COMPONENTS MUST BE GROUNDED PER NEC 690.43. 3. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(D). 4. THE INFORMATION PROVIDED IN THESE DOCUMENTS IS NOT EXHAUSTIVE. IT REMAINS THE CONTRACTORS RESPONSIBILITY TO ACHIEVE THE PROPOSED INSTALLATION, IN FULL EXERCISE OF AND COMPLIANCE WITH THE ITEMS IDENTIFIED IN NOTE 1. 5. PER NEC 690.17 PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS BE ENERGIZED IN THE OPEN POSITIONS. SIGN SHALL READ 'WARNING -ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS - TERMINALS ON BOTH UNE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION OR EQUIVALENT. 6. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. 7. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12. 8. PV METER MAY OR MAY NOT BE REQUIRED BY THE AHJ AND/OR UTILITY FOR INTERCONNECTION. 9. CONDUCTOR SIZING OF THIS DESIGN IS BASED ON RACEWAYS LOCATED OUTSIDE ATTICS OR NOT EXPOSED TO DIRECT SOUGHT. WHERE TWO DIFFERENT AMPACDIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE HIGHER AMPACITY SHALL BE PERMITTED TO BE USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO 3.OM (1DR) OR 10 PERCENT OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICH EVER IS LESS. NEC 310.15 (B)(2) 10. ALL CONDUCTORS AND RACEWAYS SHALL BE SUPPORTED ON INTERVALS AND BY METHODS REQUIRED BY THE NEC. 12. UNE TAPS TO BE MADE WITH ILSCO KUP-L-TAP INSULATION PIERCING CONNECTOR. 13. GFI BUILT IN TO ALL SUNNY BOY INVERTERS. #3 THWN-2 (3 CONDUCTOR) 1" EMT, FMC, FOR EXTERIOR APPLICATION USE PVC OR LFMC CONDUIT PV AC DISCONNECT r100A 240V 2-POLE 80A RK-1 FUSE METER O 100A SUB PANEL PV AC DISCONNECT (2) 40A 2-POLE BREAKERS NEUTRAL BONDED TO GROUND AC PANEL 200 AMP/240V L1 SUNNY BOY: 7.7-US W/ SUNNY BOY RSB-2S-US-10 & RSC-IX-US-10 SYSTEM RAPID SHUT DOWN COMPONENTS PER NEC 690.12 #6 THWN-2 (3 CONDUCTOR) 3/4" EMT, FMC, FOR EXTERIOR APPLICATION USE PVC OR LFMC CONDUIT Li \AC L2 N -#6 THWN-2 G #6 THWN-2 (3 CONDUCTOR) 3/4" EMT, FMC, FOR EXTERIOR APPLICATION USE PVC OR LFMC CONDUIT ii [� DC #3 THWN-2 CU CONDUCTOR G W/ (1) #6 E.G.C. IN 1" EMT, FMC, FOR EXTERIOR #6 THWN-2 APPLICATION USE PVC OR LFMC CONDUIT SUNNY BOY: 7.7-US W/ SUNNY BOY RSB-2S-US-10� #6 BARE COPPER GEC & RSC-iX-US-10 SYSTEM RAPID SHUT DOWN COMPONENTS PER NEC 690.12 016 #10 THWN-2 3/4" EMT OR FMC CONDUIT SOLADECK COMBINER BOX 60OV/ NON -FUSED #10 THWN-2 3/4" EMT OR FMC SOLADECK COMBINER BOX 60OV/ NON-FU: #10 AWG CU WIRE POSITIVE & NEGATIVE 3/4" MNLT CONDUIT L1 F• No A_V479 (i STATE, OF t 4U I m 0 0 #10 AWG CU WIRE 3 POSITIVE & NEGATIVE o o 3/4" MNLf CONDUIT v J J V) M z 12 MISSION SOLAR: > > o L1 MSE310SQ8T (TYP) J 3 M U 0 0 L2 z Z�� g a m W o Lu U = v M L1 12 MISSION SOLAR: z N L2 MSE310SQ8T (TYP) L C�J a z Z G D 12 MISSION SOLAR: MSE310SQ8T (TYP) 12 MISSION SOLAR: MSE31OSQ8T (TYP) W � r U 3 p g GEC BOND AT RACKING SYSTEM U (SEE NOTE #2) Z w S-3 MODULE SPECIFICATION MODULE MAKE MISSION SOLAR MODULE MODEL MSE310SQ8T FSEC CERTIFICATION III PMAX (STC) 310 W VOC (STC) 40.12 V VMPP (SIC) 33.17 V ISC (STC) 9.76 A IMPP (STC) 9.35 A NOCT 46 C TC ISC 0.039 %/C TC VOC -0.280 9./C TC PMPP -0.377 R/C OPERATING TEMP. -40-+85 C SAFETY LABELS AND MARKINGS GENERAL NOTES: 1. EQUIPMENT SUCH AS INVERTERS AND SOLAR MODULES HAVE PRE -APPLIED LABELS FOUND HEREIN SHALL BE APPLIED TO SUCH EQUIPMENT FOR INFORMATIONAL PURPOSES. 2. LABELS AND MARKINGS SHALL BE APPLIED TO COMPONENTS IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF NEC. SAFETY LABELS AND MARKINGS LEGEND A. LOCATION OF SERVICE DISCONNECTING MEANS. APPLY TO MAIN SERVICE DISCONNECTING MEANS AND PV DISCONNECTING MEANS AT POCC. MAIN SERVICE DISCONNECT MARKING A LABEL SHALL BE PERMANENTLY AFFIXED TO THE MAIN SERVICE DISCONNECT PANEL SERVING ALTERNATING CURRENT (AC) AND DIRECT CURRENT (DC) PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL BE RED WITH WHITE CAPITAL LETTERS AT LEAST 3/4 IN. IN HEIGHT AND IN A NONSERIF FONT, TO READ: 'WARNING: PHOTOVOLTAIC POWER SOURCE." THE MATERIALS USED FOR THE LABEL SHALL BE REFLECTNE, WEATHER RESISTANT, AND SUITABLE FOR THE ENVIRONMENT. CIRCUIT DISCONNECTING MEANS MARKING A PERMANENT LABEL SHALL BE AFFIXED ADJACENT TO THE CIRCUIT BREAKER CONTROLUNG THE INVERTER OR OTHER PHOTOVOLTAIC SYSTEM ELECTRICAL CONTROLLER SERVING AC AND DC PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL HAVE CONTRASTING COLOR WITH CAPITAL LETTERS AT LEAST 3/8 IN. HEIGHT AND IN A NONSERIF FONT, TO READ: "PHOTOVOLTAIC DISCONNECT." THE LABEL SHALL BE CONSTRUCTED OF DURABLE ADHESIVE MATERIAL OR OTHER APPROVED MATERIAL INVERTER SPECIFICATION INVERTER MAKE SMA SUNNY BOY INVERTER MODEL SMA 7.7-US MAX AC POWER OUTPUT 76BO kW MAX. INPUT VOLTAGE 480 V NOM. DC VOLTAGE ® 240V 380 V NOM. AC VOLTAGE 240 V MAX. CONTINUOUS OUTPUT CURRENT 32 A MAX. DC CURRENT 18.0 A MAX. DC POWER (STC) 7950 W CEC EFFICIENCY 97 % N AN EMERGENCY CONTACT ALTECH ELECTRIC 1-863-399-2175 "ACAUTION THIS SERVICE IS SUPPLIED BY MULTIPLE SOURCES. SEE DISCONNECTS BELOW. Ai PHOTOVOLTAIC S67N EQUIPPED WITH RAPID SYSTEM SHUNOWN SOLAR PHOTOVOLTAIC SYSTEM Ai -WARNING- AUTHORIZED PERSONNEL ONLY RATED AC CURRENT: BOA NOMINAL AC VOLTAGE 240V LOCATION: MAIN PV PANEL PHOTOVOLTAIC DISCONNECT Ai -WARNMO- EIECIRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. a 4``�• Gvorxv. f>y �sss e r[No 479 10. ss S�'Rr i�11:� 874,7YN`1�'` _® ELECDUC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED AUTHORIZED PERSONNEL ONLY LOCATION: DISCONNECTS, INVERTERS, JUNCTION BOXES, OTHER ENCLOSES HOLDING DC CONDUCTORS DIRECT -CURRENT PHOTOVOLTAIC POWER SOURCE Ai -WARNING-- AUTHORIZED PERSONNEL ONLY RATED MAXIMUM POWER -POINT CURRENT: 46.8A RATED MAXIMUM POWER -POINT VOLTAGE 410V MAXIMUM SYSTEM VOLTAGE 410V SHORT CIRCUIT CURRENT: 48.BA LOCATION: INVERTER MILF� 0 d 8 Y U x U V J J An M Z o¢ J 3 n o {n J<9 _ ZwoM ix Lu o W �_ U Z M C~D N Z N Z"'aM Lu N Lu 7 0 or H Z S-4 m 0 PERC; O Flecakal PararneteaeStallard Te r mu= Modulelype.,* , - MSE3005QBL .MSE49sQBT MSE2105Q8T Power Output Pmax Wp 300 305 310 M6duleEificericy`,.8.05"" ` .'' 18.35- 48.65 Tolerance 0-+3% 0-+3% 0"+3% Short-CircultCuimnt_.' Open Circuit Voltage Ise Vac A. V ,95,71 40.08 9.66A� 40.10 `,a 9:760: 40.12 led £urtent" '°x imp,*.':'A<' :9A58 '. `,#92021 .'79.345. Rated Valtage VmP V 33.12 33.14 33.17 fuSeRating _ - '" T5 ` 20 . 40 � 1xJoiinzl Operating Cell TempenttirelNOCTI� - " 4b.09°C (?2°Cj Temperature Coefficient of Pmax -0.377%/°C nT^., efip`' CnBV'" ",. ,`... %° 20C Temperature Ccettxient of Isc 0.039%/°C h 'mum SyStemVolTage 3;000VOC. "" _ Operating TemperatureRange -40°C(-40F)to+85°C (385°F) um Sedes Fux Ratlmi 20q Fi Safety Classification Class tFrunt&Bark Lead(UL standard} HUL1703 sfamlardTested toy _ Hall Safety lmpactVelocty 25mm 923 m/s SolafCells-;P-t(pe MonoAcFystal(uie5ih�om(156JSmmT ` Cell odentation 60 cells (6x10), 5 busbar Weight 182 kg (40.1 lb) Frame Anodized aluminum alloy 1-Box Protection Bass IP67 with 3 bypass -diodes PVCpre;lmp9,3710.i. 4m_nQ12AAWG ,'.-nt°',- Connector MC4 INFORMATIONSHIPPING COntafh rF7 `.. aid fi ; rh-sa Patletsa Pa '+'z305W.+... 7-71 57 Double stack 36 936 28548 kW Panels Weight Height Width Length ➢et`„.,s4'45 SO" b7.00' a ' '2g105 Mission Salnr Enegy reserves the fight In matr sDmlhwHon changes without notice u 10 CL , S;LEADlNG 300-310W CERTIFfitATIONS &'��f,.eESTS 1W. ° IEC 61215/ 61730/ 61701 UL 170311sted gQa3 P�yye�GU^rd= CEC MSE305SQST: 305WP, 60CELL SOLAR MODULE CURRENT -VOLTAGE CURVE Voltage M Current-voltuie characteristics with dependence on irmdance and module temperature BASIC DESIGN (UNITS: mm) FrontVi w Bade Vlew x� MISSION SOLJ�R ENERGY Mlashon Solar Energy I W03 S. New araW.N Ave., San Antonio. Tenn 74235 Info•meslonsohuom Iwww.mlalonsolaccom T cMualao�a s�nnrner_6.nus -"s,�rysey7.ous'" suMr.noy77us <<._�.:. R,_.:.6e'v":':9P'"�-ie'ov"'J.l•"•—ia v""''a i.o_v^,+t@' me'v-... .. arov. .. General amo F nu POWER+ SOLUTION The SMA Power+ Solution combines legendary SMA inverter performance and intelligent DC module -level electronics in one cost-effective, comprehensive package. This means that you can achieve maximum solar power production for your customers while also realizing significant installation savings. 11 � NEWI Advanced communication interface allows for 50% faster setup and commissioning thanks to reduced components and a simplified process. Visit www.SMA-Americo.com for more information. f`l 479 , �F • ' 411 m 0 V J e) M Z oa 0 � m� o J 3 M U V) J C N rn W C7 LU i a M N 2'1 N ZMar�i LU y v W w � o O Z Z 7 '-. SUPERIORINiEGf.A710NJ N WITH THE ' P0YAR+:$0LUB01l4P' WZ Q � �- 3 W Z V co n 0 U w U ll Oo S-5 D t .rtek Tow g1�ltaeA55u�, .. AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Parry Authorized To Apply Mark. Applicant: Quick Mount PV Address: 2700 Mitchell Dr. Bldg. 2 Walnut Creek, CA 94598 Country: USA Contact: Benjamin Kuttesch Duane Menton Phone: (925) 478-8743 (925) 476-8847 FAX: (925) 478-8765 Manufacturer: Quick Mount PV Address: 2700 Mitchell Dr. Bldg. 2 Walnut Creek, CA 94598 Country: USA Contact: Benjamin Kuttesch Duane Menton Phone: (925) 478-8743 (925)478-8847 FAX: (925) 478-8765 ben.kuttesch@quickmountpv.com Email: duane.menton@qulckmountpv.com Email: Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA Control Number: 4008516 Authorized by: ben.kuttesch@qulckmountpv.com duane.menton@quickmountpv.com 900 0901DVIUS Iniertek This document supersedes all previous Authorizations to Mark for the noted Report Number. MbSMNomedanak is faWm uae Mina %CEeN aad is pmeedquaaNmtlo ceNAalloa qae tbeavasa krtedakand M Ca2lnnma'[nlupdnu'huNe,q 4WV are f imdayaemeaL lnleMkemnresro Gatilflytourypvry, o9a Wn b W Clam h emEa,m x ft ayaaaaml( any IMS, exfamma,alanageoacaaWned by heu ahislwOwdmdon to Ma&0*Na Cent a auhalzed W pemtll mpytlq wau, Jon ofM NMatrelM to a ak aa, Men wNh h endmLy. use of lntaake CaNf Eon ms:, .uitt aMeo O.ns lald a WMMaegeel„enteM in weAaMa .d MaA. My NMausa duet Iaaa,kare l ft sale aaMa.Naf Ma tssa, maad, pmd.a,u avmmat Nabs applied mn§M by hallek. WW Falory Assaa,prdseM Fapm, up sa Sam Im Me M,aum aMe M eppaplaa umpaatla Ce,EflmEan makh aaadanaaaiM he e9l mast Mryere Wfadm rylpow NpWuNmavallgands mat dolotrelie4e Ma MentalMNIoWOahe aiaa mapam Intertek Testing Services NA Inc. 645 East Algonquin Road, Adinglon Heights, 11160005 Telephone 800-345-3851 or 947-439-5667 Fax 312-283-1672 Standard(s): Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat - Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.t) Product: Photovoltaic Racking System QRall - Installed Using Quick Mount PV's QRail Series Installation Manual,Jan-2019 Rev 4 Brand Name: Quick Mount PV Models: ORO ATM for Report 101786065LAX-001 Page 1 of 2 ATM Issued: 5-Feb-2019 W 16.3.15 n0Apr-M Mandatory �lyV7,rul d ural: .� SENGSNU,ITY�: fng®nrifty fr"t:,EA qi : rthg Cuick Mount P �` :. 'RES PECTITHE,t2O0F' Rail Spans for Quick Mount PV QRail Standard System Mean Roof Height: 0 < h 515 ft Panel Orientation: Portrait Table 1 Roof Angle: O< B 5 7 degrees Exposure Category: C Roof Ground Wind Speed (mph) Wind Zone Snow Load 100 110 1 115 120 130 140 150 160 1 170 175 180 190 0 116 116 ';7tf5*'114, "::104 95'. ,89„a.§;z$2-; 77 :�,. .75 r.73t?..69a 10 ,.102. 102 .f ROE 1' ,r 100 95 89;; '; 42y_� 75,,, ;;73;.�` yugkj. 20 '86 86` "'a4104'6.,$6; ? 86 86= 86 -= t'32i77'". 7S, . mr73=s;""§$+�; 30 :74 14 " --7 44 "i4 .' 74 74< .. 7h " 74= , -73` Zone 40 <65 65 ;.-63^' '65, ''65 65-! 65, ?65,-?�65 :-765.!R,.6Sr, 1 50 59 59 '.59r"' 59 5960 54 54 a'S4d =.54" 2 54 54 `: , .54 « '" �4 =� ;- 54,' :70 E44 50 = 50 i$( u so =50_'' 50, ` '" 0 �$0 `` `SC)?`: "80 48 48 48 48 48 48 48 48 48 48 48 90 44 44 44 44 44 44 44 44 44 44 44 0 100 ;, 90 96'`°,_' 82 75 69 65 ' 'S7, 55 °53` 10 100 90 „85 "s 82 75 69 . 65 ',60 ' 57 55 a-53'`' 20 '96 : 86 `6ff "¢+'$2 : 75 69 1 65 Qkr 0:57 55 v :53ru1 �,50' 30 74 = 74 ; 74 ;Zq "' 74 69 6 7)t0 57 ,` S5 53 Zone 40 65 65 fx4,f`776 7 _, 65: ; 65. 6S." `d60, : `57 : 55,,. ;53`YN 2 50 59 r 59 , .59'= ' 59 *. 59 ' S9' ,59. i59 - ;.r.57 55 a 531'€ „�TSO , 60 54 ` 54 SA 54 . 54'. 54 70 50 50 :.50k ,: '0 so So- 80 48 48 48 48 48 48 48 48 48 48 48 48 90 44 44 44 44 44 44 44 44 44 44 44 44 0 79 - 71 1';6&' 55 : 51 ' 48 45 44 42 40 10 79 71, 56 ,.'s5'' 59 55- 48 45 44 42 40 20 79 t 71 ; ;a,68xb r 65 ,!; 59 ,;. ,55':; i51 48 45 44 42 40 30 74 ' 71 .: Lt',fs'82a ` .65= '1= 59 . ,"' 55:] , Sl.;,;. 48 45 44 42 40 Zone 40 65 48 45 44 42 40 3 50 59 - 5 !' 59 '; !, g"' 55 C:"' 51,' : 48 45 44 42 40 60 54 '. 54 :`54., 54 ',54 54.': 51 48 45 44 42 40 70 50'' ;50 "' SD.y,. '"SD .; 50 50" 50,. 48 45 44 42 40 80 48 48 48 4848 48 48 48 45 44 42 40 90 1 44 44 44 44 1 44 44 44 44 44 1 44 1 42 1 40 Notes: 1. Tables are based on critical rail span for load combinations as specified in chapter 2 of the ASCE 7-10 and allowable design loads per the 2015 Aluminum Design Manual. 2. Panels are assumed to be in portrait orientation with a maximum length of 67.5'1 959 Larchmont Court, Aurora, IL 60504 630-219-1997 (P) www.structuralenginuityinc.com 3/4/2019 C1 .eelellutrr.. ea' 5 `y yJ U / JJJ N0.BZ479 -- U -.a {n M Z a F o JLn O ¢ Z� w m W o LU = v t� Pj F CtINz N Z a M W y LU w � o a Z 7 S-6 0 0 .`"ttuennNrvr, L-Mount Installation Instructions Installation Toots Required: tape measure, roofing bar, chalk line, stud finder, caulking gun, sealant compatible with roofing materials, drill with 7/32" or 1/8" bit, drill or impact gun with 1/2" socket. Locate, choose, and mark centers of rakers to be Carefully lift composition roof shingle with roofing Insert flashing between lst and 2nd course. Slide mounted. Select the courses of shingles where bar, just above placement of mount. Remove up so top edge of flashing Is at least I/V higher mounts will be placed. nails as required and backfill holes with aproved than the bun -edge of the 3rd course and lower sealant See 'Proper Flashing Placement' on next flashing edge is above the bumedge of lst course. page. Mark center for drilling. Ifattaching With lag bolt use a bit (Lag). Use a Clean off any sawdust, and fill holewith sealant place L-foot onto elevated flute and rotate L-foot to Wblt(ST)forattachingwith thestmctural screw. compatible with roofing materials. desiredodentation. Drill pilot hole into roof and rafter, taking care to drill square to the root Do not use mount as a drill guide Drill a 2" deep hole Into rafter. Prepare lag bolt or structural screw with sealing You are now ready for the mck of your choice. washer. Using a 9rinch socket on an Impact gun, Follow all the directions of the mck manufacturer drive prepared lag bolt through Woot until L-foot as well as the module manufactures NOTE: Make can no longer easily rotate. DO NOT over -torque. wretopofL-Footmakessolid contactwith racking NOTE: Structural screw can be driven with T-30 hex head bit BI 7.2.3-44 Jul-2018 Rev4 L-Mount I QMLM / QMLM-ST Elevated Water Seal Technology® REM, DESCRIPTION QTY THIS EDGE TOWARDS ROOF RIDGE NO. I FLASHING, ROUNDED CORNERS, C X 17 X.040',.438'HOLE. 5052. 1 MILL 2 L-FOOT, 2'X 3.3D'FOR.436'O.D.FASfENER, 2-1/16'SLOi. 6061- I Td 6005A-T61 MILL 3 WASHER, SEALING, 5/16° ID X 3/4' 00, EPDM BONDED SS 1 4 LAG SCREW: HEX HEAD, 5/16" x4", 1" SS 1 .5 STRUCTURAL SCREW, QMPV. TH S WASHER HEAD, 5/16"X 12.00 '5 VIAVAILABLEINMILL, p (4.20) RALE ON 5T 4.50 ONLY 9.002.00 - 0.397 -1.00 2.09 3.30.90) MILL, NISHES ( Quick Mount PW .040 TITLE (3.sa i a.0a QMLM & QMLM-ST: L-MOUNT, c2—!o) —11_ 2'7—t5 2-1/16"SLOT QMLM QMLM ST �xaEmfLR® SRE DRAWN BY: R&D R R,c' ma`s w1 A DATE. 7,,,.m 9 ,w au ruvn u..wu M SGue IimtinwfFWtlMLL eM SC91EI WBGMI.Id3J�3XFFlOfI ,,,,n�md .-..WYn _CO[OIGII(09116WQMWM9.. .. ___ ...__ BI 7.2.3-44 quick Mount W RESPECT THE ROOF Jul-2018 Rev 4 r� ` `• E NJCSNLC' � e No V, : fi^ i/�/ 1 U_. OjF� : /y/ < 'o "DREWD' m ¢ 8 Y U W U U J J N Z rn o ¢ so J 3 O O J d- W O W U2'd ltJNz N M� ua w W w O � a Z S-7