Loading...
HomeMy WebLinkAboutSPEC SHEET CRAIG REYNOLDSSS-GASPT www.goodmanmfg.com 6/19 Supersedes 6/18 Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons Contents Air Handler Nomenclature ....................2 Heater Kit Nomenclature ......................2 Product Specifications ...........................3 Dimensions ............................................4 Airflow Data ...........................................6 Heat Kit Data ..........................................8 Wiring Diagram ....................................15 Accessories ..........................................18 Product Features • Internal factory-installed thermal expansion valves for cooling and heat pump applications • Direct drive, multi-speed ECM blower motor • All-aluminum evaporator coil • Coil mounting track for quick repositioning • Optimized for use with R-410A refrigerant • Cabinet air leakage less than 2.0% at 1.0 inch H₂O when tested in accordance with ASHRAE standard 193 • Cabinet air leakage less than 1.4% at 0.5 inch H₂O when tested in accordance with ASHRAE standard 193 • AHRI certified; ETL listed • Rigid SmartFrame™ cabinet • Horizontal or vertical configuration capabilities • 21” depth for easier attic access • DecaBDE-free thermoplastic drain pan with secondary drain connections • Screw-less sides and back helps to reduce condensation when installed in humid locations • Foil-faced insulation covers the internal casing to reduce cabinet condensation • Galvanized, leather grain-embossed finish • Glue-less cabinet insulation retention • Tool-less filter access • Field Installed 3 kW – 25 kW electric heater kits available * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. ASPT Series 2 www.goodmanmfg.com SS-GASPT Nomenclature HKS X 03 X A AA 123456,7 Unit  Type Revisions HKS Heat  Kit  for  Engineering  Revisions Air  Handlers Phase Circuit  Breaker E      Three  Phase  240  V X No  circuit  breaker F      Three  Phase  208/240  V C Circuit  Breaker G      Three  Phase  460  V A      Single  Phase  208  V B      Single  Phase  240  V C      Single  Phase  208/240  V D      Three  Phase  208  V Heating  Capacity  @  240  Volts 03 3.0  kW 15 14.4  kW Cabinet  Size  (MAX) 05 4.5  kW 19 19.2  kW  wth  150F  limit C      C  Cabinet 06 6.0  kW 20 19.2  kW  with  170F  limit D      D  Cabinet 08 8.0  kW 25 25.0  kW X      All  Cabinet  Sizes 10 9.6  kW B 1 7 8 Brand Engineering  * A Single-­‐piece Major/  Minor  Revisions Air  Handler *   Not  used  for  inventory  management Unit  Application Refrigerant  Charge C Ceiling  Mount  PSC  Motor 4  =  R-­‐410A D Downflow  PSC  Motor E Multi-­‐Position  Variable-­‐Speed  Motor Electrical R Multi-­‐Position  PSC  Motor 1      208/240  V,  1  Phase,  60  Hz S Multi-­‐Position  EEM  Motor W Wall  Mount  PSC  Motor Cabinet  Width B    17½" Cabinet  Finish C    21" U Unpainted D      24½" P Painted N Uncased Nominal  Capacity  Range  @  13  SEER 47 –  3½  Tons Expansion  Device 49 –  4  Tons F Flowrater 59, 61 –  5  Tons T Expansion  Valve 25, 29, 33 – 2 Tons 35, 37 – 2½ Tons 37, 39 – 3 Tons   S 2 5,6 18 1 A AA 11,12 P 3 T 4 10 4 SS-GASPT www.goodmanmfg.com 3 Product Specifications ASPT 25B14* ASPT 29B14* ASPT 33C14* ASPT 35B14* ASPT 37B14* ASPT 37C14* ASPT 39C14* ASPT 47C14* ASPT 49C14* ASPT 59C14* ASPT 47D14* ASPT 49D14* ASPT 61D14* Nominal Ratings Cooling (Btu/h)24,000 24,000 24,000 28,000 30,000 36,000 36,000 42,000 48,000 60,000 42,000 48,000 60,000 Blower Diameter 9½"9½"10⅝”9½"9½"10⅝"10⅝”10⅝"10⅝”10⅝"10⅝"11¹⁵⁄₁₆"11¹⁵⁄₁₆" Width 6"6"8”6"6"8"8”10⅝"8”10⅝"10⅝"10⅝"10⅝" Coil Connections Liquid ⅜"⅜"⅜”⅜”⅜"⅜"⅜”⅜"⅜”⅜"⅜"⅜"⅜" Suction ¾"⅞"⅞”¾”⅞"⅞"⅞”⅞"⅞”⅞"⅞"⅞"⅞" Coil Drain Connect (FPT)¾"¾"¾”¾”¾"¾"¾”¾"¾”¾"¾"¾"¾" Electrical Data Voltage 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 Minimum Circuit Ampacity 5.8 / 5.8 5.8 / 5.8 4.9 / 4.9 5.6/5.6 5.6 / 5.6 5.6 / 5.6 4.9/ 4.9 4.9 / 4.9 7.1 / 7.1 7.9 / 7.9 5.6 / 5.6 8.6 / 8.6 8.6 / 8.6 Max. Overcurrent Device (Amps)15 / 15 15 / 15 15 / 15 15/15 15 / 15 15 / 15 15 / 15 15 / 15 15 / 15 15/15 15 / 15 15 / 15 15 / 15 Minimum VAC 197 197 197 197 197 197 197 197 197 197 197 197 197 Maximum VAC 253 253 253 253 253 253 253 253 253 253 253 253 253 Blower Motor Full Load Amps (FLA)4.6 4.6 3.9 4.5 4.5 4.5 3.9 3.9 5.7 6.3 4.5 6.9 6.9 Horsepower (HP)¾¾¾¾¾¾¾¾¾1 ¾1 1 Ship Weight (Lbs.)116 129 118 129 129 144 118 144 125 144 155 167 167 *Airflow rate @.3 static Note: Assumes dry coil; SCFM correction for wet coil = 4% (208V / 240V) 4 www.goodmanmfg.com SS-GASPT Dimensions -2_MIN- -2_MIN--2_MIN- C B .55"(1.40 cm).55"(1.40 cm) 2.17" (5.51cm) DE 21" 9.21" 11.3" (28.70 cm) .55" (1.40 cm) A 45.00 21.0316.4117.63 9.21 14.97 .6 .6 11.5 58.0021.0323.3424.63 9.2111 .528.7725.772.17.6.61.63 17.97 1.67 1.67 17.66 F INLET(FRONT VIEW) 1" (2.54 cm) .55" (1.40 cm) 19.5" (49.5 cm) INLET(RIGHT SIDE VIEW) 1.73 1.73" (4.39 cm) 1.73" (4.39 cm) 14.16 1.00 .54 1.73 1.7321.16 .99.54 19.52 19.52 2.17 1.45" (3.68 cm) 3.08"(7.82 cm) 1.63" (4.13 cm) 2.91" (7.39 cm) 2.93" (7.44 cm) G H 1.638.78 11.91 12.28 12.41 4.50" (11.43 cm) 4.50 4.502.91 2.91 2.93 2.93 3.07 1.45 3.08 1.45 1.4" (3.6 cm) 3.1" (7.9 cm) 5.2" (13.3 cm) 7.5" (19.1 cm) 1.8" (4.6 cm) 1.413.085.167.541.78 1.413.085.167.54 1.78 PLASTICBREAKER COVER LOGO LOCATION SEE DRAIN PORT DETAIL LIQUID LINE SUCTION TUBE INLETTUBE 0270AOO676 DRAIN PORT DETAIL Model A"B"C"D"E"F"G"H" ASPT25B14*45 16⅜17½15¼12 14 9 12 3/4 ASPT29B14*53½16⅜17½ 235/8 20½ 14 9 7⅝ ASPT33C14*49 19⅞21 179/16 14⅜171⁄2 109/16 121⁄2 ASPT35B14*45 16⅜17½15¼12 14 9 123/4 ASPT37B14*531⁄2 16⅜ 17½ 235/8 20½ 14 9 7⅝ ASPT37C14*531⁄2 19⅞21 2113/16 18½ 17½ 107/8 6⅞ ASPT39C14*49 19⅞21 179/16 14⅜17½109/16 121⁄2 ASPT47C14*531⁄2 19⅞21 2113/16 18⅝ 17½107/8 6⅞ ASPT47D14*531⁄2 233/8 24½21½185/16 21 12⅝6⅞ ASPT49C14*49 19⅞21 179/16 14⅜17½109/16 121⁄2 ASPT49D14*58 233/8 24½26⅛22⅞21 12⅝131/4 ASPT59C14*531⁄2 19⅞21 2113/16 18⅝ 17½107/8 6⅞ ASPT61D14*58 233/8 24½26⅛22⅞21 12⅝131/4 SS-GASPT www.goodmanmfg.com 5 Dimensions (Cont.) 6 www.goodmanmfg.com SS-GASPT Airflow Data Model Speed Tap Static Pressure (in w.c) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 ASPT 25B14AB 1 640 585 580 545 510 490 410 340 280 2 800 765 725 700 670 645 595 565 490 3 840 805 800 760 740 700 670 625 580 4 985 950 920 885 850 815 800 760 725 5 1,475 1,440 1,400 1,375 1,335 1,305 1,270 1,240 1,150 ASPT 29B14AB 1 595 590 565 530 505 455 380 305 260 2 790 775 745 705 665 625 585 515 445 3 865 820 790 770 735 695 645 595 530 4 1,015 980 955 925 880 840 795 770 720 5 1,505 1,465 1,430 1,410 1,385 1,350 1,315 1,285 1,220 ASPT 33C14BA 1 865 685 615 540 480 410 335 270 215 2 935 875 820 785 720 655 600 550 490 3 1110 1050 1000 955 905 855 795 760 710 4 1355 1310 1260 1220 1180 1135 1095 1055 1005 5 1560 1515 1475 1430 1395 1370 1330 1295 1260 ASPT 35B14AB 1 875 845 845 825 795 780 730 680 630 2 985 945 925 915 905 880 845 795 760 3 1,070 1,025 990 985 980 960 940 905 860 4 1,245 1,205 1,170 1,135 1,115 1,115 1,100 1,090 1,035 5 1,310 1,275 1,230 1,190 1,155 1,135 1,085 1,080 1,040 ASPT 37B14AB 1 1,025 985 945 910 875 830 795 735 690 2 1,150 1,105 1,065 1,025 995 950 915 870 825 3 1,240 1,200 1,160 1,120 1,085 1,050 1,010 970 925 4 1,425 1,400 1,355 1,320 1,290 1,250 1,215 1,180 1,145 5 1,490 1,455 1,415 1,390 1,355 1,320 1,285 1,250 1,205 ASPT 37C14AC 1 980 935 895 860 825 800 755 710 665 2 1,125 1,075 1,045 1,000 965 930 880 845 820 3 1,235 1,190 1,155 1,120 1,085 1,045 1,005 965 920 4 1,485 1,450 1,425 1,390 1,355 1,315 1,275 1,230 1,190 5 1,565 1,535 1,510 1,480 1,240 1,390 1,365 1,320 1,280 ASPT 39C14BA 1 865 685 615 540 480 410 335 270 215 2 935 875 820 785 720 655 600 550 490 3 1110 1050 1000 955 905 855 795 760 710 4 1355 1310 1260 1220 1180 1135 1095 1055 1005 5 1560 1515 1475 1430 1395 1370 1330 1295 1260 ASPT 47C14BA 1 955 895 855 840 780 735 675 615 560 2 1,100 1,050 1,005 965 925 870 815 770 705 3 1,205 1,160 1,120 1,075 1,035 990 940 885 830 4 1,445 1,410 1,365 1,320 1,275 1,235 1,190 1,140 1,095 5 1,525 1,480 1,435 1,400 1,360 1,320 1,275 1,230 1,180 ASPT 47D14AC 1 1,055 1,015 950 895 830 785 730 680 620 2 1,210 1,165 1,110 1,070 1,015 960 900 840 785 3 1,335 1,290 1,250 1,205 1,145 1,100 1,050 980 910 4 1,625 1,580 1,530 1,495 1,455 1,405 1,350 1,295 1,230 5 1,720 1,670 1,625 1,580 1,540 1,490 1,435 1,390 1,325 ASPT 49C14AC 1 1325 1280 1240 1200 1160 1115 1065 1025 985 2 1465 1420 1380 1355 1315 1280 1240 1195 1155 3 1505 1465 1425 1390 1355 1330 1290 1245 1205 4 1600 1565 1530 1490 1460 1425 1385 1365 1290 5 1690 1660 1625 1585 1555 1520 1485 1400 1250 ASPT 49D14AC 1 1,485 1,435 1,380 1,320 1,265 1,200 1,230 1,015 930 2 1,570 1,525 1,480 1,430 1,370 1,315 1,235 1,155 1,035 3 1,680 1,600 1,570 1,555 1,475 1,430 1,360 1,280 1,185 4 1,800 1,765 1,715 1,670 1,625 1,590 1,510 1,465 1,390 5 2,215 2,160 2,120 2,085 2,040 2,000 1,970 1,930 1,865 See notes on page 7. SS-GASPT www.goodmanmfg.com 7 Airflow Data (cont.) Model Speed Tap Static Pressure (in w.c) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 ASPT 59C14AC 1 1,370 1,330 1,295 1,255 1,215 1,180 1,140 1,100 1,060 2 1,535 1,500 1,465 1,430 1,405 1,370 1,335 1,300 1,210 3 1,680 1,645 1,615 1,575 1,545 1,510 1,440 1,330 1,205 4 1,905 1,855 1,780 1,690 1,605 1,515 1,425 1,330 1,205 5 1,940 1,855 1,775 1,700 1,605 1,505 1,420 1,320 1,205 ASPT 61D14AC 1 1,545 1,495 1,440 1,390 1,335 1,260 1,180 1,080 1,030 2 1,745 1,695 1,625 1,575 1,525 1,475 1,400 1,360 1,275 3 1,905 1,855 1,815 1,770 1,725 1,670 1,635 1,575 1,500 4 2,155 2,105 2,090 2,045 2,000 1,970 1,935 1,890 1,830 5 2,340 2,310 2,265 2,220 2,185 2,165 2,120 2,080 2,030 Notes • The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. • Use the CFM adjustment factors of .98 for horizontal left, .95 for horizontal right & .96 for downflow orientations. • Assumes dry coil with filter in place. • All models are shipped from the factory with the speed tap set on T4. • Assumes dry coil; SCFM correction for wet coil = 4% • All ASPT models are shipped from the factory with the speed tap set on T4. 8 www.goodmanmfg.com SS-GASPT Heat Kit Data See notes on page 14. Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit Heater Amps MCA¹MOP²Heater Amps MCA¹MOP²MCA¹MOP² ASPT25B14AB 0/0 5.8/5.8 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 19 20 --------------- HKSX05XC - 208 V 17.3 27 30 --------------- HKSX06XC - 208 V 21.6 33 35 --------------- HKSX08XC - 208 V 28.8 42 45 --------------- HKSX10XC - 208 V 34.6 49 50 --------------- HKSC05XC - 208 V Breaker 17.3 27 30 --------------- HKSC08XC - 208 V 28.8 42 45 --------------- HKSC10XC - 208 V 34.6 49 50 --------------- HKSX03XC - 240 V No Breaker 12.5 21 25 --------------- HKSX05XC - 240 V 20.0 31 35 --------------- HKSX06XC - 240 V 25 37 40 --------------- HKSX08XC - 240 V 33.3 47 50 --------------- HKSX10XC - 240 V 40.0 56 60 --------------- HKSC05XC - 240 V Breaker 20.0 31 35 --------------- HKSC08XC - 240 V 33.3 47 50 --------------- HKSC10XC - 240 V 40.0 56 60 --------------- ASPT29B14AB 0/0 5.8/5.8 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 19 20 --------------- HKSX05XC - 208 V 17.3 27 30 --------------- HKSX06XC - 208 V 21.7 33 35 --------------- HKSX08XC - 208 V 28.9 42 45 --------------- HKSX10XC - 208 V 34.7 49 50 --------------- HKSC05XC - 208 V Breaker 17.3 27 30 --------------- HKSC08XC - 208 V 28.9 42 45 --------------- HKSC10XC - 208 V 34.7 49 50 --------------- HKSC15XA - 208 V 34.7 49 50 17.3 22 25 71 80 HKSX03XC - 240 V No Breaker 12.5 21 25 --------------- HKSX05XC - 240 V 20 31 35 --------------- HKSX06XC - 240 V 25 37 40 --------------- HKSX08XC - 240 V 33.3 47 50 --------------- HKSX10XC - 240 V 40 56 60 --------------- HKSC05XC - 240 V Breaker 20 31 35 --------------- HKSC08XC - 240 V 33.3 47 50 --------------- HKSC10XC - 240 V 40 56 60 --------------- HKSC15XB - 240 V 40 56 60 20 25 25 81 90 ASPT33C14BA 0/0 4.9/4.9 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 18.4 20 --------------- HKSX05XC - 208 V 17.3 27 30 --------------- HKSX06XC - 208 V 21.7 32 35 --------------- HKSX08XC - 208 V 28.9 41 45 --------------- HKSX10XC - 208 V 34.7 48 50 --------------- HKSC05XC - 208 V 17.3 27 30 --------------- HKSC08XC - 208 V Breaker 28.9 41 45 --------------- HKSC10XC - 208 V 34.7 48 50 --------------- HKSC15XB 3 - 208 V 34.7 48 50 17.3 21.7 25 69.9 70 SS-GASPT www.goodmanmfg.com 9 Heat Kit Data (cont.) See notes on page 14. See notes on page 14. Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit Heater Amps MCA¹MOP²Heater Amps MCA¹MOP²MCA¹MOP² HKSX03XC - 240 V No Breaker 12.5 21 25 --------------- HKSX05XC - 240 V 20 29.9 30 --------------- HKSX06XC - 240 V 25 36.1 40 --------------- HKSX08XC - 240 V 33.3 46.5 50 --------------- HKSX10XC - 240 V 40 54.9 60 --------------- HKSC05XC - 240 V 20 29.9 30 --------------- HKSC08XC - 240 V Breaker 33.3 46.5 50 --------------- HKSC10XC - 240 V 40 54.9 60 --------------- HKSC15XB - 240 V 40 54.9 60 20 25 25 79.9 80 ASPT35B14AB 0/0 5.6/5.6 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 19 20 --------------- HKSX05XC - 208 V 17.3 27 30 --------------- HKSX06XC - 208 V 21.7 33 35 --------------- HKSX08XC - 208 V 28.9 42 45 --------------- HKSX10XC - 208 V 34.7 49 50 --------------- HKSX15XC - 208 V 34.7 49 50 --------------- HKSC05XC - 208 V Breaker 17.3 27 30 --------------- HKSC08XC - 208 V 28.9 42 45 --------------- HKSC10XC - 208 V 34.7 49 50 --------------- HKSC15XC - 208 V 34.7 49 50 17.3 22 25 71 80 HKSX03XC - 240 V No Breaker 12.5 21 25 --------------- HKSX05XC - 240 V 20.0 31 35 --------------- HKSX06XC - 240 V 25 37 40 --------------- HKSX08XC - 240 V 33.3 47 50 --------------- HKSX10XC - 240 V 40.0 56 60 --------------- HKSX15XC - 240 V 40 56 60 --------------- HKSC05XC - 240 V Breaker 20.0 31 35 --------------- HKSC08XC - 240 V 33.3 47 50 --------------- HKSC10XC - 240 V 40.0 56 60 --------------- HKSC15XC - 240 V 40.0 56 60 20 25 25 81 90 ASPT37B14AB 0/0 5.6/5.6 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 19 20 --------------- HKSX05XC - 208 V 17.3 27 30 --------------- HKSX06XC - 208 V 21.7 33 35 --------------- HKSX08XC - 208 V 28.9 42 45 --------------- HKSX10XC - 208 V 34.7 49 50 --------------- HKSC05XC - 208 V Breaker 17.3 27 30 --------------- HKSC08XC - 208 V 28.9 42 45 --------------- HKSC10XC - 208 V 34.7 49 50 --------------- HKSC15XA - 208 V 34.7 49 50 17.3 22 25 71 80 HKSX03XC - 240 V No Breaker 12.5 21 25 --------------- HKSX05XC - 240 V 20 31 35 --------------- HKSX06XC - 240 V 25 37 40 --------------- HKSX08XC - 240 V 33.3 47 50 --------------- HKSX10XC - 240 V 40 56 60 --------------- 10 www.goodmanmfg.com SS-GASPT Heat Kit Data (cont.) See notes on page 14. Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit Heater Amps MCA¹MOP²Heater Amps MCA¹MOP²MCA¹MOP² HKSC05XC - 240 V Breaker 20 31 35 --------------- HKSC08XC - 240 V 33.3 47 50 --------------- HKSC10XC - 240 V 40 56 60 --------------- HKSC15XB - 240 V 40 56 60 20 25 25 81 90 ASPT37C14BA 0/0 5.6/5.6 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 19 20 --------------- HKSX05XC - 208 V 17.3 27 30 --------------- HKSX06XC - 208 V 21.7 33 35 --------------- HKSX08XC - 208 V 28.9 42 45 --------------- HKSX10XC - 208 V 34.7 49 50 --------------- HKSC05XC - 208 V Breaker 17.3 27 30 --------------- HKSC08XC - 208 V 28.9 42 45 --------------- HKSC10XC - 208 V 34.7 49 50 --------------- HKSC15XA - 208 V 34.7 49 50 17.3 22 25 71 80 HKSC19CA - 208 V 34.7 49 50 34.7 43 45 92 100 HKSC15XF - 208 V ^0 5.6 15 30 38 40 ------ HKSX03XC - 240 V No Breaker 12.5 21 25 --------------- HKSX05XC - 240 V 20 31 35 --------------- HKSX06XC - 240 V 25 37 40 --------------- HKSX08XC - 240 V 33.3 47 50 --------------- HKSX10XC - 240 V 40 56 60 --------------- HKSC05XC - 240 V Breaker 20 31 35 --------------- HKSC08XC - 240 V 33.3 47 50 --------------- HKSC10XC - 240 V 40 56 60 --------------- HKSC15XB - 240 V 40 56 60 20 25 25 81 90 HKSC19CB - 240 V 40 56 60 40 50 50 106 110 HKSC15XF - 240 V ^0 5.6 15 34.6 43 45 ------ ASPT39C14BA 0.0/0.0 4.9/4.9 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 18.4 20 --------------- HKSX05XC - 208 V 17.3 27 30 --------------- HKSX06XC - 208 V 21.7 32 35 --------------- HKSX08XC - 208 V 28.9 41 45 --------------- HKSX10XC - 208 V 34.7 48 50 --------------- HKSC05XC - 208 V Breaker 17.3 27 30 --------------- HKSC08XC - 208 V 28.9 41 45 --------------- HKSC10XC - 208 V 34.7 48 50 --------------- HKSC15XB 3 - 208 V 34.7 48.2 50 17.3 21.7 25 69.9 70 HKSC19CH - 208 V 34.7 48.2 50 34.7 43.3 45 91.5 100 HKSC15XF - 208 V ^0 4.9 15 30 37.5 40 ------ HKSX03XC - 240 V No Breaker 12.5 21 25 --------------- HKSX05XC - 240 V 20 29.9 30 --------------- HKSX06XC - 240 V 25 36.1 40 --------------- HKSX08XC - 240 V 33.3 46.5 50 --------------- HKSX10XC - 240 V 40 54.9 60 --------------- SS-GASPT www.goodmanmfg.com 11 Heat Kit Data (cont.) See notes on page 14. Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit Heater Amps MCA¹MOP²Heater Amps MCA¹MOP²MCA¹MOP² HKSC05XC - 240 V Breaker 20 29.9 30 --------------- HKSC08XC - 240 V 33.3 46.5 50 --------------- HKSC10XC - 240 V 40 54.9 60 --------------- HKSC15XB - 240 V 40 54.9 60 20 25 25 79.9 80 HKSC19CB - 240 V 40 54.9 60 40 50 50 104.9 110 HKSC15XF - 240 V ^0 4.9 15 34.6 43 45 ------ ASPT47C14BA 0/0 4.9/4.9 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 18.4 20 --------------- HKSX05XC - 208 V 17.3 27 30 --------------- HKSX06XC - 208 V 21.7 32 35 --------------- HKSX08XC - 208 V 28.9 41 45 --------------- HKSX10XC - 208 V 34.7 48 50 --------------- HKSC05XC - 208 V Breaker 17.3 27 30 --------------- HKSC08XC - 208 V 28.9 41 45 --------------- HKSC10XC - 208 V 34.7 48 50 --------------- HKSC15XA - 208 V 34.7 48.2 50 17.3 22 25 69.9 70 HKSC19CA - 208 V 34.7 48.2 50 34.7 43.3 45 91.5 100 HKSC15XF - 208 V ^0 4.9 15 30 38 40 ------ HKSX03XC - 240 V No Breaker 12.5 21 25 --------------- HKSX05XC - 240 V 20 29.9 30 --------------- HKSX06XC - 240 V 25 36.1 40 --------------- HKSX08XC - 240 V 33.3 46.5 50 --------------- HKSX10XC - 240 V 40 54.9 60 --------------- HKSC05XC - 240 V Breaker 20 29.9 30 --------------- HKSC08XC - 240 V 33.3 46.5 50 --------------- HKSC10XC - 240 V 40 54.9 60 --------------- HKSC15XB - 240 V 40 54.9 60 20 25 25 79.9 80 HKSC19CB - 240 V 40 54.9 60 40 50 50 105 110 HKSC15XF - 240 V ^0 4.9 15 34.6 43 45 ------ ASPT47D14AC 0/0 5.6/5.6 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 19 20 --------------- HKSX05XC - 208 V 17.3 27 30 --------------- HKSX06XC - 208 V 21.7 33 35 --------------- HKSX08XC - 208 V 28.9 42 45 --------------- HKSX10XC - 208 V 34.7 49 50 --------------- HKSC05XC - 208 V Breaker 17.3 27 30 --------------- HKSC08XC - 208 V 28.9 42 45 --------------- HKSC10XC - 208 V 34.7 49 50 --------------- HKSC15XA - 208 V 34.7 49 50 17.3 22 25 71 80 HKSC20DA - 208 V 34.7 49 50 34.7 43 45 92 100 HKSC15XF - 208 V ^0 5.6 15 30 38 40 ------ HKSC20XF - 208 V ^0 5.6 15 37.5 47 50 ------ 12 www.goodmanmfg.com SS-GASPT Heat Kit Data (cont.) See notes on page 14. Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit Heater Amps MCA¹MOP²Heater Amps MCA¹MOP²MCA¹MOP² HKSX03XC - 240 V No Breaker 12.5 21 25 --------------- HKSX05XC - 240 V 20 31 35 --------------- HKSX06XC - 240 V 25 37 40 --------------- HKSX08XC - 240 V 33.3 47 50 --------------- HKSX10XC - 240 V 40 56 60 --------------- HKSC05XC - 240 V Breaker 20 31 35 --------------- HKSC08XC - 240 V 33.3 47 50 --------------- HKSC10XC - 240 V 40 56 60 --------------- HKSC15XB - 240 V 40 56 60 20 25 25 81 90 HKSC20DB - 240 V 40 56 60 40 50 50 106 110 HKSC15XF - 240 V ^0 5.6 15 34.6 43 45 ------ HKSC20XF - 240 V ^ 0 5.6 15 43.3 54 60 ------ ASPT49C14AC 0.0/0.0 7.1/7.1 15/15 --------------- HKSX03XC - 208 V No Breaker ------------------------ HKSX05XC - 208 V 17.3 28.8 30 --------------- HKSX06XC - 208 V 21.7 34.2 35 --------------- HKSX08XC - 208 V 28.9 43.2 45 --------------- HKSX10XC - 208 V 34.7 50.5 60 --------------- HKSC05XC - 208 V Breaker 17.3 28.8 30 --------------- HKSC08XC - 208 V 28.9 43.2 45 --------------- HKSC10XC - 208 V 34.7 50.5 60 --------------- HKSC15XB 3 - 208 V 34.7 50.5 60 17.3 21.7 25 72.1 80 HKSC19CH - 208 V 34.7 50.5 60 34.7 43.3 45 93.8 100 HKSC15XF - 208 V ^0 7.1 15 30 37.5 40 ------ HKSX03XC - 240 V No Breaker ------------------------ HKSX05XC - 240 V 20 32 35 --------------- HKSX06XC - 240 V 25 38 40 --------------- HKSX08XC - 240 V 33.3 49 50 --------------- HKSX10XC - 240 V 40 57 60 --------------- HKSC05XC - 240 V Breaker 20 32 35 --------------- HKSC08XC - 240 V 33.3 49 50 --------------- HKSC10XC - 240 V 40 57 60 --------------- HKSC15XB - 240 V 40 57 60 20 25 25 82 90 HKSC19CB - 240 V 40 57 60 40 50 50 107 110 HKSC15XF - 240 V ^0 7.1 15 34.6 43 45 ------ ASPT49D14AC 0/0 8.6/8.6 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 22 25 --------------- HKSX05XC - 208 V 17.3 30.3 35 --------------- HKSX06XC - 208 V 21.7 36 40 --------------- HKSX08XC - 208 V 28.9 45 45 --------------- HKSX10XC - 208 V 34.7 52 60 --------------- SS-GASPT www.goodmanmfg.com 13 Heat Kit Data (cont.) See notes on page 14. Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit Heater Amps MCA¹MOP²Heater Amps MCA¹MOP²MCA¹MOP² HKSC05XC - 208 V Breaker 17.3 30.3 35 --------------- HKSC08XC - 208 V 28.9 45 45 --------------- HKSC10XC - 208 V 34.7 52 60 --------------- HKSC15XB 3 - 208 V 34.7 52 60 17.3 22 25 74 80 HKSC20DH - 208 V 34.7 52 60 34.7 43 45 95 100 HKSC15XF - 208 V ^0 8.6 15 30 38 40 ------ HKSC20XF - 208 V ^0 8.6 15 37.5 47 50 ------ HKSC25DA - 208 V 52 74 80 35 43 45 117 125 HKSX03XC - 240 V No Breaker 12.5 24 25 --------------- HKSX05XC - 240 V 20 34 35 --------------- HKSX06XC - 240 V 25 40 40 --------------- HKSX08XC - 240 V 33.3 50.3 60 --------------- HKSX10XC - 240 V 40 59 60 --------------- HKSC05XC - 240 V Breaker 20 34 35 --------------- HKSC08XC - 240 V 33.3 50.3 60 --------------- HKSC10XC - 240 V 40 59 60 --------------- HKSC15XB - 240 V 40 59 60 20 25 25 84 90 HKSC20DB - 240 V 40 59 60 40 50 50 109 110 HKSC15XF - 240 V ^0 8.6 15 34.6 43 45 ------ HKSC20XF - 240 V ^0 8.6 15 43.3 54 60 ------ HKSC25DB - 240 V 60 84 90 40 50 50 134 150 ASPT59C14AC 0.0/.0.0 7.9/7.9 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 21 25 --------------- HKSX05XC - 208 V 17.3 30 30 --------------- HKSX06XC - 208 V 21.7 35 35 --------------- HKSX08XC - 208 V 28.9 44 45 --------------- HKSX10XC - 208 V 34.7 51 60 --------------- HKSC05XC - 208 V Breaker 17.3 30 30 --------------- HKSC08XC - 208 V 28.9 44 45 --------------- HKSC10XC - 208 V 34.7 51 60 --------------- HKSC15XB 3 - 208 V 34.7 51 60 17.3 22 25 73 80 HKSC19CH - 208 V 34.7 51 60 34.7 43 45 95 100 HKSC15XF - 208 V ^0 7.9 15 30 38 40 ------ HKSX03XC - 240 V No Breaker 12.5 24 25 --------------- HKSX05XC - 240 V 20 33 35 --------------- HKSX06XC - 240 V 25 39 40 --------------- HKSX08XC - 240 V 33.3 50 50 --------------- HKSX10XC - 240 V 40 58 60 --------------- HKSC05XC - 240 V Breaker 20 33 35 --------------- HKSC08XC - 240 V 33.3 50 50 --------------- HKSC10XC - 240 V 40 58 60 --------------- HKSC15XB - 240 V 40 58 60 20 25 25 83 90 HKSC19CB - 240 V 40 58 60 40 50 50 108 110 HKSC15XF - 240 V ^0.0 7.9 15 34.6 43 45 ------ 14 www.goodmanmfg.com SS-GASPT Heat Kit Data (cont.) Heating kW Correction Factor Supply Voltage 240 230 220 210 208 Correction Factor 1.00 0.92 0.84 0.77 0.75 Multiply the 240-volt heating capacity by correction factors. ¹ Minimum Circuit Ampacity (Heater Amps + Motor Amps) X 1.25 ² Maximum Overcurrent Protection = 2.25 X Motor Amps + Heater Amps ^ Circuit 1: Single-phase for Air Handlers Circuit 2: Three-phase for HKR3 Heater Kits --- indicates Not Required Note: The 208 or 240 in the heat kit part number field is for clarification of the nominal voltage for this model. 3 Notation is correct as XB because technically the 240V heater kit application can be used here without any issues. Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit Heater Amps MCA¹MOP²Heater Amps MCA¹MOP²MCA¹MOP² ASPT61D14AC 0/0 8.6/8.6 15/15 --------------- HKSX03XC - 208 V No Breaker 10.8 22 25 --------------- HKSX05XC - 208 V 17.3 30.3 35 --------------- HKSX06XC - 208 V 21.7 36 40 --------------- HKSX08XC - 208 V 28.9 45 45 --------------- HKSX10XC - 208 V 34.7 52 60 --------------- HKSC05XC - 208 V Breaker 17.3 30.3 35 --------------- HKSC08XC - 208 V 28.9 45 45 --------------- HKSC10XC - 208 V 34.7 52 60 --------------- HKSC15XB 3- 208 V 34.7 52 60 17.3 22 25 74 80 HKSC20DH - 208 V 34.7 52 60 34.7 43 45 95 100 HKSC15XF - 208 V ^0 8.6 15 30 38 40 ------ HKSC20XF - 208 V ^0 8.6 15 37.5 47 50 ------ HKSC25DA - 208 V 52 74 80 35 43 45 117 125 HKSX03XC - 240 V No Breaker 12.5 24 25 --------------- HKSX05XC - 240 V 20 34 35 --------------- HKSX06XC - 240 V 25 40 40 --------------- HKSX08XC - 240 V 33.3 50.3 60 --------------- HKSX10XC - 240 V 40 59 60 --------------- HKSC05XC - 240 V Breaker 20 34 35 --------------- HKSC08XC - 240 V 33.3 50.3 60 --------------- HKSC10XC - 240 V 40 59 60 --------------- HKSC15XB - 240 V 40 59 60 20 25 25 84 90 HKSC20DB - 240 V 40 59 60 40 50 50 109 110 HKSC15XF - 240 V ^0 8.6 15 34.6 43 45 ------ HKSC20XF - 240 V ^0 8.6 15 43.3 54 60 ------ HKSC25DB - 240 V 60 84 90 40 50 50 134 150 SS-GASPT www.goodmanmfg.com 15 Wi r i n g i s s u b j e c t t o c h a n g e . A l w a y s re f e r t o t h e w i r i n g d i a g r a m o n t h e un i t f o r t h e m o s t u p - t o - d a t e w i r i n g . ⚠ Wa r n i n g Hi g h V o l t a g e : D i s c o n n e c t a l l p o w e r b e f o r e s e r v i c i n g o r i n s t a l l i n g t h i s u n i t . M u l t i p l e p o w e r so u r c e s m a y b e p r e s e n t . F a i l u r e t o d o s o m a y c a u s e p r o p e r t y d a m a g e , p e r s o n a l i n j u r y , o r d e a t h . ⚡ BK BL BK L1 L 2 BK BK HT R 1 TL HT R 1 RD 987 R WH BL PU TL BK 5 634PL F BK RD 1 2 WH RD L2 L 1 BK BK RD BK RD RHT R 2 TL L1 BK 6 8 972 RD PU 4 53 BK RD 1PL F BK L2 L 1 L2 RDYL M1 M2 BK RD YL RD R1M4 RD BK M3 HT R 3 TL HT R 2 HT R 1 TL TL PU M2 R2 YL M1 BL WH BRBL RD BK RD BK TL HT R 1 BKHT R 4 HT R 3 HT R 2 BK RD 978 L2 L1 L1 L2 2 5 634PL F 1 RD M1 YL BK M2 BL WH 6 BL RD BK YL 8 97 M6M5 M3 R1 M4 RD PU M7 R2 M8BL TL TLTLYL BL RDBK RD BL BR 4 532 BK PL F 1 ON E ( 1 ) E L E M E N T R O W S TW O ( 2 ) E L E M E N T R O W S TH R E E ( 3 ) E L E M E N T R O W S FO U R ( 4 ) E L E M E N T R O W S FL M1 M2 FL FL M1 M2 M3 M4 FL FL FL FL FL FL FL CO P P E R P O W E R S U P P L Y (U S E R A T I N G P L A T E ) US E M I N . 7 5 ° C F I E L D W I R E 0 14 0A 0 0 0 6 3 - B PL M PL F TR FA C T O R Y W I R I N G FI E L D W I R I N G N O T ES : 1) R E D W I R E S T O B E O N T R A N S F O R M E R T E R M I N A L " 3 " F O R 2 4 0 V O L T S A N D O N TE R M I N A L " 2 " F O R 2 0 8 V O L T S . 2) S E E C O M P L E T E W I R I N G D I A G R A M S I N I N S T A L L A T I O N I N S T RU C TI O N S F O R PR O P E R L O W V O L T A G E W I R I N G CO NN EC T I O N S . 3) C O N F I R M S P E E D T A P S E L E C T I O N I S A P P R O P R I A T E F O R A P P L I C A T I O N . I F SP E E D T A P N E E D S T O B E C H A N G E D , C O NN EC T P UR PL E W I R E F R O M T E R M I N A L 4 OF C R R E L A Y T O A P P R O P R I A T E T A P A T T B 4) B R O W N A N D W H I T E W I R E S A R E U S E D F O R H E A T K I T S O N L Y . 5) F U S E : 3 A , 2 5 0 V , 3 A G C A R T R I D G E F U S E . RE L A Y EV A P O R A T O R M O T O R TE R M I N A L B O A R D REM TB BK RD BLYL BL U E BL A C K RE D YE L L O W CO M P ON EN T C O D E BR O W N PU R P L E GR E E N PU BRGR FE M A L E P L U G C O NN EC T O R MA L E P L U G C O NN EC T O R TR A N S F O R M E R H I G H V O L T A G E L O W V O L T A G E H I G H V O L T A G E L O W V O L T A G E PL F 2 CO L O R C O D E TR 6 5 P L M 4 4 2 4 V 5 1 23 EM W IR IN G C O D E 20 8 / 2 4 0 V O L T S 11 PL F PL M L1 PL M 2L2 IF R E P L A C E M E N T O F T H E O R I G I N A L W I R E S SU P P L I E D W I T H T H I S A S S E M B L Y I S N E C E S S A R Y , US E W I R E T H A T C O N F O R M S T O T H E N A T I O N A L EL E C T R I C C O D E . FL FU S E L I N K TL TH E R M A L L I M I T HT R H E A T E L E M E N T S CR C O N T R O L R E L A Y NO T E : WH E N I NS T AL LI N G H EA TE R K I T , E N S UR E SP E ED T A P D O E S N O T EX CE E D M I N I M U M B L O W E R S P EE D ( M B S ) S PE CI F I E D F O R T H E A I R H A N D L E R / H E A T E R K I T C O M B I N A T I O N O N T H I S UN I T ' S S & R P L A T E . A FT ER I N S T A L L I N G O P T I O N A L H E A T K I T , MA R K A " X " I N T H E B O X P R O V I D E D AB OV E . M A R K A C C O R D I N G T O NU MB E R O F H E A T E R E L E M E N T R O W S I N S T A LL ED . NO M A R K IN D I C A T ES N O H E A T K I T I NS T A L L E D . WH I T E WH LG N W2 R W1 C G 4 Y1 O Y2 1 DH 32 5 A B 1 C EM 2 43 5 4 7 CR FU S E HO L D E R (O P T I O N A L ) 1 SE E N O T E 1 U S E C O P P E R W IR E E Q U IP M E N T G R O U N D B L E M Y L B L 5 B K C B K P L F B K1 R D2 3 2 4 0 2 4 V 4 1 2 3 T R R D B L B R 4 5 W H6 7 8 9 P L M G R D 1 2 3 4 5 6 7 8 9 A B17 4 C R S E E N O T E 2 2 1 4 3 5 N C G L R D P U B L B R W H B L R D G R R D o r B KBL R D B K R D W 2 R W 1 C G 4 Y 1 O Y 2 1 D H 3 2 5 R D o r B K P U B R W H O R W H W H B LGR R D o r B K B L F U S E H O L D E R (O P T I O N A L ) L 2 L 1 SE E NO T E 1 SE E NO T E 4 1 354 2 AL T E RN AT E H E A T RE L A Y P U R D G R W H 1 3 2 4 CR 5 AL T E RN AT E H E A T RE L A Y Air Handler Wiring Diagram NOTE: The five element, 25 kW heater kit is not shown above. 16 www.goodmanmfg.com SS-GASPT Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.⚠ Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.⚡ M9 M10 TL FLHTR1 HTR2 HTR3 HTR4 M6 M5 L2L2L1 RD BL BK YL RD BK BK RD M1 M3 YL BL BK RD M2 R1 M4 PU 9 8 WH M8 7 6 BR 5 M7 R2 BL RD BL 4 3 2 BL YL BK 1 PC RD BK HTR5 L1L2L1 BL R3 PU PU 1L 2L CB4 CB3 CB1 CB2 WH PU TL FLTL FL TL FL TL FL COLOR CODE BK = BLACK BL = BLUE BR = BROWN PK = PINK RD = RED WH = WHITE YL = YELLOW WIRING CODE: HIGH VOLTAGE LOW VOLTAGE COMPONENT CODE PC = 9 PIN CONNECTOR HTR = HEATER ELEMENT TL = THERMAL LMT RS = RELAY/SEQUENCER TB = TERMINAL BLOCK CB = CIRCUIT BREAKER CC = CONTACTOR FL = FUSE LINK TR = TRANSFORMERSR = STRAIN RELIEF EM = EVAPORATOR MOTOR EBTDR = ELEC. BLOWER TIME DELAY RC = RUN CAPACITOR GR = GREEN OR = ORANGE PU = PURPLE 0140M00274-A NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXCEED OR EQUAL THE MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER / HEATER KIT COMBINATION ON THIS UNIT'S SERIAL PLATE.AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED BELOW. NO MARK INDICATES NO HEAT KIT INSTALLED. FIVE (5) ELEMENT ROWS NOTE:- THIS LABEL MUST BE ATTACHED ON THE AIRHANDLER IN A PROMINENT LOCATION BK RD BK RD Five-Element Heater Kit Wiring Diagram SS-GASPT www.goodmanmfg.com 17 RC BR BR EM 3 5 2 1 4 RD TR WH BR BK L2 L1 RD RD BL BK PU BLPU RELAY/SEQUENCER THERMAL LIMIT TRANSFORMER RUN CAPACITOR ELEC. BLOWER TIME DELAY RELAY EVAPORATOR MOTOR HEAT ELEMENTHTR EBTDR EM RS TL TR RC COMPONENT CODE 24 VOLT TR RC EM EBTDR EBTDR COM NONC 208/240 VOLTS 0140M00273-A WH BK GND L3 T3 CC L2 L1 BL T2 T1 R BL RD BR M3 M4 PU M2 PU WH M1 WH WH RS BL WH PU BL RD 1 2 3 5 7 8 9 6 4 WH PC EBTDR TERMINAL BLOCK CONTACTOR 9-PIN CONNECTORPC CC TB M2 RS M1 M 3M 4 L1 L2 LOW HIGH CC HEATER CONTROL AR POWER SUPPLY 1 2 3 4 5 6 7 8 9 PC (CIRCUIT 1) NC SPEEDUP GR C RD XFMR-RXFMR-C M1 COMK1 NOK1 L1 RDGR PK BL PU SR STRAIN RELIEF M1 YL YELLOW BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RD RED WH WHITE COLOR CODE (CIRCUIT 2) HKR POWER SUPPLY L1 L2 L3 FL SR FUSE LINK W2 W1 WBRGRBLPK GRCRD T1 T2 T3 123 4 5 FL HTR3 TL FL HTR2 TL FL HTR1 TL TLFLHTR3 TLFLHTR2 TLFLHTR1 CB CIRCUIT BREAKER L1L2L3 BKBK BK BK BK BK BK BK BK BK BK BK BK BK BK BK BK BK BK WIRING CODE HIGH VOLTAGE LOW VOLTAGE BK NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXCEED OR EQUAL THE MINIMUM BLOWER SPEED (MBS)SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S SERIAL PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED BELOW. NO MARK INDICATES NO HEAT KIT INSTALLED. NOTE:- THIS LABEL MUST BE ATTACHED ON THE AIRHANDLER IN A PROMINENT LOCATION BK RD TB L1 L2 CIRCUIT 11 PH 208-240V CIRCUIT 23 PH. 208-240V Three-Phase Heater Kit Wiring Diagram Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.⚠ Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.⚡ 18 www.goodmanmfg.com SS-GASPT Accessories Downflow Insulation Kit DFK-B DFK-C DFK-D ASPT24B14**ASPT42C14**ASPT42D14** ASPT35B14**ASPT48C14**ASPT48D14** ASPT60D14** ASPT61D14** Filters Chassis Part #Size B ALFH16201E 16.0” x 20.0” C ALFH1912201E 19.5” x 20.0” D ALFH20231E 23.0” x 20.0”