Loading...
HomeMy WebLinkAboutSubmittal - CTV Chiller - SLC Rock Road Jail CTV Chiller Repl 4-14-2020 Prepared For: Salas O’Brien Date: April 14, 2020 Customer P.O. Number: Customer Project Number: Sold To: St. Lucie County Job Number: Job Name: SLC - Rock Road Jail Chiller Repl Trane U.S. Inc. is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 1 Centrifugal Water Chiller Chris Cowling Trane U.S. Inc. 6965 Vista Parkway North, Suite 11 West Palm Beach, FL 33411 Phone: (561) 683-1521 Cell: (561) 683-1521 Fax: (561) 697-8714 The attached information describes the equipment we propose to furnish for this project, and is submitted for your approval. Product performance and submittal data is valid for a period of 6 months from the date of submittal generation. If six months or more has elapsed between submittal generation and equipment release, the product performance and submittal data will need to be verified. It is the customer’s responsibility to obtain such verification. Please Note:  Please review submittal for accuracy before ordering. Submittal J:\Jobs\46\55879\2\Submittal - CVHE Chiller - SLC Rock Road Jail Chiller Repl 4-14-2020.doc Table Of Contents Product Summary ........................................................................................................................... 1 Centrifugal Water Chiller (Item A1) Tag Data .................................................................................................................................................. 3 Product Data ............................................................................................................................................ 3 Performance Data .................................................................................................................................... 5 Product Data Report-CH-2 ....................................................................................................................... 6 Mechanical Specifications ........................................................................................................................ 8 Unit Dimensions ..................................................................................................................................... 13 Weight, Clearance & Rigging Diagram ................................................................................................... 18 Accessory .............................................................................................................................................. 20 Field Wiring ............................................................................................................................................ 22 Field Installed Options - Part/Order Number Summary Centrifugal Water Chiller ........................................................................................................................ 25 SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 3 of 25 Tag Data - Centrifugal Water Chiller (Qty: 1) Item Tag(s) Qty Description Model Number A1 CVHE450 1 Centrifugal Chiller ( CTV ) CVHE0450 Product Data - Centrifugal Water Chiller Item: A1 Qty: 1 Tag(s): CVHE450 Standard ship cycle CVHE, CVHF & CVHG Centrifugal liquid chiller with 3 stage compressor Compressor size: 450 nominal tons Adaptiview controls Incoming line hertz: 60 Compressor motor hertz: 60. Incoming line voltage: 460 volt Compressor motor voltage: 460 volt 3 phase Startup Included - Trane Service must start equipment for warranty to be honored Compressor motor power: 233 kW Motor frame size: 440E Compressor impeller cutback: 230 Standard cooling Evaporator shell size: 050 short barrel Evaporator bundle size: 580 nominal tons Evaporator tubes: 0.75 inch (19.1 mm) dia. internally enhanced copper Evaporator tube wall: .025 inch (0.6 mm) thick Evaporator fluid type: Water Evaporator waterbox type: Non-marine Evaporator waterbox construction: Standard Evaporator water box passes: Two pass Evaporator waterbox pressure: 150 psig (1034 kPa) Evaporator waterbox connection: Victaulic Evap waterbox arrangement: in LH end - out LH end Thermal dispersion flow switch (IFM) - Field Installed (Fld) Condenser shell size: 050 short barrel Condenser bundle size: 500 nominal tons Condenser tube: 0.75 inch (19.1 mm) internally enhanced copper Condenser tube wall: .028 inch (0.7 mm) thick (thicker tube wall option) Condenser shell construction: Standard Condenser fluid type: Water Condenser waterbox type: non-marine Condenser waterbox construction: Standard Condenser water box passes: Two pass Condenser waterbox pressure: 150 psig (1034 kPa) Condenser waterbox connection: Victaulic Condenser waterbox arrangement: in LH end - out LH end Standard tube sheet construction Thermal dispersion flow switch (IFM) - Field Installed (Fld) Orifice size: 400 nominal tons Agency listing: U.L. listed unit (United States requirement) Factory performance test: Standard air run and vibration test Selection tolerance: AHRI Standard tolerance Brass logo with customer specified engraving No unit insulation package (field installed insulation by field insulator) AHRI Certified Complies with ASHRAE 90.1 - 2016 Generic BAS BACnet interface R514 Refrigerant Trane Supplied Refrigerant Low Voltage Wye-Delta Starters Starter type: Unit Mounted Wye-Delta Starter maximum RLA: 346 Amps Starter power connection: Circuit Breaker High-Interrupt Starter power connection maximum RLA: 296 Amps SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 4 of 25 Starter option: Surge protector/lightning arrestor Factory Start-up 10 year Parts, Labor, & Refrigerant warranty SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 5 of 25 Performance Data - Centrifugal Water Chiller Tags CVHE450 Primary cooling capacity (tons) 300.00 Primary power (kW) 166.30 Primary RLA (Incoming line) (A) 246.40 Minimum circuit ampacity (A) 306.00 Maximum overcurrent protection (A) 500.00 Compressor motor RLA (A) 237.70 Motor locked rotor amps (A) 1661.00 Actual motor voltage full load (V) 460.0 Actual motor frequency (Hz) 60.0 Primary efficiency (kW/ton) 0.5542 NPLV (kW/ton) 0.4937 Evaporator entering fluid temp (F) 54.00 Evaporator leaving fluid temp (F) 42.00 Evaporator fluid flow rate (gpm) 597.10 Evaporator pressure drop (ft H2O) 6.66 Evaporator fouling factor (hr-sq ft-deg F/ Btu) 0.000100 Evaporator fluid concentration (%) 0.00 Condenser entering fluid temp (F) 85.00 Condenser leaving fluid temp (F) 95.00 Condenser fluid flow rate (gpm) 841.90 Condenser pressure drop (ft H2O) 11.12 Condenser fouling factor (hr-sq ft-deg F/ Btu) 0.000250 Condenser fluid concentration (%) 0.00 Refrigerant charge (lb) 550.0 Shipping weight (lb) 17144.0 Operating weight (lb) 19067.0 Unit center of gravity X (in) 28.000 Unit center of gravity Y (in) 45.000 Unit center of gravity Z (in) 57.000 Left Front isolator load (lb) 4599.0 Left Rear isolator load (lb) 3621.0 Right Front isolator load (lb) 5980.0 Right Rear isolator load (lb) 4867.0 Chiller heat rejected to ambient (MBh) 2.83 Evaporator maximum fluid flow rate (gpm) 1848.40 Evaporator pressure drop maximum flow (ft H2O) 50.91 Evaporator minimum fluid flow rate (gpm) 336.10 Evaporator pressure drop minimum flow (ft H2O) 2.10 Condenser maximum fluid flow rate (gpm) 1688.90 Condenser pressure drop maximum flow (ft H2O) 37.51 Condenser minimum fluid flow rate (gpm) 460.60 Condenser pressure drop minimum flow (ft H2O) 3.74 Compressor Weight (lb) 5418.0 Motor Weight (lb) 1732.0 Starter Weight (lb) 557.0 Suction Elbow Weight (lb) 280.0 Economizer Weight (lb) 635.0 Evaporator Weight (lb) 4025.0 Evaporator Waterboxes Weight (lb) 630.0 Condenser Weight (lb) 2454.0 Condenser Waterboxes Weight (lb) 399.0 Miscellaneous Weight (lb) 1013.0 SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 6 of 25 Centrifugal Chiller Job Information Tag CH-2 Model Number CVHE0450 1 Quantity Certified in accordance with the AHRI Water-Cooled Water-Chilling and Heat Pump Water-Heating Packages Certification Program, which is based on AHRI Standard 550/590 (I-P) and AHRI Standard 551/591 (SI). Certified units may be found in the AHRI Directory at www.ahridirectory.org. ASHRAE 90.1 - 2007 Complies ASHRAE 90.1 - 2007 Add. M Complies ASHRAE 90.1-2010 Complies ASHRAE 90.1-2013 Complies ASHRAE 90.1 - 2016 Complies Unit Information Compressor size 450 CVHE Model Impeller size 230 Orifice size 400 Motor size 233 Refrigerant R-514A 60. Hz Motor frequency 460. V Motor voltage 60. Hz Incoming line frequency 460. V Incoming line voltage Evap shell size 050S Cond shell size 050S 580 Evap bundle size Cond bundle size 500 Evap tube type TECU TECU Cond tube type Evap tube thickness 0.025" Cond tube thickness 0.028" Cond passes Evap passes Two pass evap water box Two pass cond water box Design Information 300.0 tons Refrigeration capacity Refrigerant charge 550 lb Total power 166.3 kW 17144 lb Shipping weight 0.5542 kW /ton Refrigeration Efficiency 19067 lb Operating weight 0.4937 kW /ton NPLV.IP No Free cooling option W ye-delta starter type No Green Seal certification Unit Mounted WyeD Application type Standard cooling 2.84 MBh Heat rejection capacity Evaporator Information Entering fluid evap 54.00 F Evap fluid type water 42.00 F Leaving fluid evap N/A Evap fluid concentration Flow evap 597.1 gpm Fluid pressure drop evap 6.66 ft H2O Min flow evap 336.1 gpm 2.10 ft H2O Fluid pressure drop evap min flow Maximum flow evap 1848 gpm 50.9 ft H2O Fluid pressure drop evap max flow 1.990 gpm / ton Flow evap/refrigeration capacity Evap water box type non-marine Evap fouling factor 0.000100 hr-sq ft-deg F/ Btu Evap water box pressure 150 psig Condenser Information 85.00 F Entering fluid cond Cond fluid type water 95.00 F Leaving fluid cond N/A Cond fluid concentration Flow cond 841.9 gpm Fluid pressure drop cond 11.1 ft H2O Selection code revision level M0C1E111C111S00 55218 Page 1 of 2 4/14/2020 Product Version 31.8.0.0 Report Date Data generation date 4/9/2020 SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 7 of 25 Centrifugal Chiller Job Information Tag CH-2 Model Number CVHE0450 1 Quantity Min flow cond 460.6 gpm Minimum fluid pressure drop cond 3.74 ft H2O Maximum flow cond 1689 gpm Maximum fluid pressure drop cond 37.5 ft H2O Flow cond/refrigeration capacity 2.806 gpm / ton Cond water box type non-marine Cond fouling factor 0.000250 hr-sq ft-deg F/ Btu Cond water box pressure 150 psig Electrical Information 237.70 A Compressor motor RLA 1661 A Motor LRA 306 A Min circuit ampacity 246.4 A Primary RLA (Incoming line) 500 A 0.90 Un-corrected power factor Max overcurrent protection Information for LEED Projects 300.0 tons Total power 166.3 kW Refrigeration capacity Refrigerant charge 550.0 lb 0.4937 kW /ton NPLV.IP Compliant with the requirements of the LEED Energy and Atmosphere Enhanced Refrigerant Management Credit (EAc4) due to the R-514A refrige rant GWP being <2. Trane recognizes and respects the U.S. Green Building Council® mandate that a default 2% Refrigerant Leakage Rate (Lr) be used by all manufacturers of centrifugal chillers when calculating the Enhanced Refrigerant Management Credit because there is no industry standard. Trane has exhaustively documented a leak rate of less than 0.5% for CenTraVac™ chillers (models CVHE, CVHF, CVHG, CVHL, CVHS, CVHM, CDHF, CDHG, CVHH and CDHH) and utilizes an average design refrigerant charge of less than 2 lb./ton. The overall environmental performance of the CenTraVac chiller is verified in its product-specific Type III Environmental Product Declaration (EPD) in accordance with ISO 14025, further demonstrating Trane’ s commitment to safeguarding the environment. Note: The U.S. Green Building Council’ s LEED ® green building program is the preeminent program for the design, construction, maintenance and operations of high-performance green buildings. It provides independent, third -party verification that a building project meets the highest green building and performance measures. Selection code revision level M0C1E111C111S00 55218 Page 2 of 2 4/14/2020 Product Version 31.8.0.0 Report Date Data generation date 4/9/2020 SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 8 of 25 Mechanical Specifications - Centrifugal Water Chiller Item: A1 Qty: 1 Tag(s): CVHE450 Compressor-Motor Direct drive multiple-stage compressor, multi-stage capacity control guide vanes. Shrouded aluminum alloy impellers dynamically balanced. Motor-compressor assembly balanced to .15 in./sec (.0038m/sec) maximum vibration measured on motor and bearing housings. Refrigerant cooled, hermetically sealed, two-pole, squirrel cage induction motor. Two pressure lubricated bearings support the rotating assembly. A direct drive submerged oil pump motor, 3/4 hp (.560 kW) 115V/50/60/1 provides filtered and temperature controlled oil to compressor bearings. Evaporator-Condenser Shells are carbon steel plate. Evaporator includes rupture disk per BSR/ASHRAE 15 Safety Code. Carbon steel tube sheets are drilled, reamed and grooved to accommodate tubes. Tubes are individually replaceable externally finned seamless copper. Tubes are mechanically expanded into tube sheets. Eliminators are installed over entire length of the evaporator tube bundle. A multiple orifice control system maintains proper refrigerant flow. Condenser baffle prevents direct impingement of compressor discharge gas upon the tubes. Refrigerant side of the assembled unit is tested at both pressure(30.00 psi leak test) and vacuum. Water side is hydrostatically tested at one and one-half times design working pressure, but not less than 225.00 psi. Trane reserves the right to implement chiller technology enhancements that will reduce the chiller's refrigerant charge, with no impact on chiller performance. Changes may be reflected in the chiller's nameplate refrigerant charge and the quantity of refrigerant charge shipped to the jobsite, depending upon the final date of equipment manufacture. Water Boxes Drains and vents - Water boxes typically have 3/4-inch NPTI vents and drain connections provided. Evaporators have 2 vents and 2 drains, condensers have 1 vent and 1 drain. If grooved connections are offered, the design is based on Style 77. Non-marine water boxes have water connections that extend out from the end. Economizer A flash economizer with no moving parts provides power saving capability. Purge System The EarthWise(TM) purge includes a 1/4 hp 115V/60/1, 100V/50/1 air cooled condensing unit, purge tank, drier elements, and a 1/20 hp (.037 kW) 115V/60/1, 110V/50/1 pump-out compressor. The purge is designed with an activated carbon filtration system that includes an autoregeneration feature which results in automatic high-efficiency removal of noncondensibles from the chiller without manual carbon maintenance. The purge meets Green Seal GS-31 with a leak rate less than 1.0% of the charge per year and also meets ASHRAE 147 with a leak rate of less than one unit mass of refrigerant per unit of air. AdaptiView Control Panel: The Tracer(tm) AdaptiView is a microprocessor-based chiller control system that provides complete stand alone system control and monitoring for the water cooled CenTraVac (TM). It is a factory mounted package including a full complement of controls to safely and efficiently operate the CenTraVac chiller, including oil management, purge operation, interface to the starter, and comprehensive motor protection including three phase solid state motor overload. Inlet and outlet water (fluid) temperature sensors are located in the evaporator and condenser waterbox connections as standard. The display is a touch sensitive 12 1/8" diagonal color liquid crystal display (LCD) that uses color graphics and animation to ensure ease of use. The touch sensitive interface allows the operator to view the chiller graphically and receive a status indication via subsystem animations. The operator can navigate easily between the primary chiller subsystems including: compressor, evaporator, condenser, and motor. For each subsystem, you can view status and detailed operating parameters. In addition, alarms, reports, trending, and settings can all be accessed quickly from the main screen. The display is mounted on a flexible "arm" that allows extensive height and viewing angle variations. The panel supports an extensive list of languages including the default English. The data can be set to be viewed in inch pounds IP or metric units SI. For remote starters - Class 1 control panel voltage (30-115 V) are clearly labeled in the control panel. Class 2 input voltage (30V max) is also labeled in the control panel. Operating Data including: *operating hours *number of starts SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 9 of 25 *chilled water setpoint *evaporator and condenser water flow status *evaporator entering and leaving water temperatures *evaporator saturated refrigerant temperatures *evaporator approach temperature *evaporator refrigerant pressure *condenser entering and leaving water temperatures *condenser saturated refrigerant temperatures *condenser approach temperature *condenser refrigerant pressure *oil differential pressure *oil tank temperature *purge mode *purge average daily pump-out time *% RLA per phase for motor *RLA per phase *volts per phase *power factor *kw *kwh *frequency The AdaptiView also contains the following dedicated reports: Evaporator, Condenser, Compressor, Motor, Purge, and ASHRAE. Each report is comprised of a detailed listing of operational data relative to that chiller subsystem. Control functions including: *leaving chilled water temperature *percent demand limit *chiller water reset (based on return water temperature *front panel control type *setpoint source *differential to start *differential to stop Status data including: *waiting to start *running *run limit *run inhibit (adaptive) *auto *free cooling (option) *preparing to shutdown *shutting down (post lube) *stopped Safeties including: Automatic safety shutdown for: *Low chilled water temperature, *low evaporator refrigerant temperature *high condenser refrigerant pressure *evaporator and condenser flow status *low evaporator/condenser differential refrigerant pressure *low oil pressure *oil pressure overdue *high or low oil temperature *high bearing oil temperature (requires enhanced protection option) *high motor current *high motor temperature *starter function faults *critical temperature and pressure sensor faults SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 10 of 25 The devices are of a latching trip out type requiring manual reset. Non-latching safety trip outs for operating conditions external to the chiller automatically permits unit to resume normal operation when condition is corrected. Advanced motor protection monitors 3-phase current to provide latching trip out protection from adverse effects of phase loss, phase unbalance, phase reversal, loss of phase reversal protection, and electrical distribution faults (momentary power loss) by instantaneous trip out of motor. Surge protection - Detects surge and limits chiller loading through inlet vane modulation. Head relief through lowering cooling tower water temperature can be requested. If not corrected within 7 minutes, chiller is shut down. Enhanced Adaptive Control(TM) - Built in intelligence to keep the chiller on line (safely making maximum tons) while simultaneously preventing chiller damage/failure. During any chiller limiting mode of operation, the control panel enunciates the condition via a relay output. Trending: The controller provides 10 standard graphs for trending multiple parameters, The operator can add an additional 6 custom graphs if desired. On any one custom graph, the operator can choose to trend up to 10 unique parameters from a more comprehensive list. Two Y axes are available for any graph to facilitate readability. Diagnostics: AdaptiView includes comprehensive diagnostic monitoring. All active diagnostics are available, and up to 20 historic diagnostics are communicated to the operator via the 12 1/8" LCD display with graphic navigation system. Each diagnostic is time and date stamped. Service Tool: A PC-based service tool called Tracer TU, connected to the chiller via USB port, is available for additional cost and displays the last 100 diagnostics, indicating the time, date of occurrence, and system parameters at the time of the diagnostic. The service tool provides advanced troubleshooting and access to sophisticated configuration settings not needed during operation of the chiller. Security: The AdaptiView can be set to prevent unauthorized access to the chiller settings. The operator can choose to secure the operating settings with a password. Data and reports can still be accessed once the settings are locked out. The memory for the AdaptiView is non-volatile type, so if power is lost, operating settings are retained. A life time battery is standard, which is used only to support the clock function for the chiller. Chilled and Condenser water pump relays: Chilled water and condenser water pump relays are provided and it is recommended that they be used for pump control. Hardwire BAS Interface provides: Chilled Water Setpoint input - Provides for setpoint adjustment of control point from multiple sources Current Limit Setpoint input - provides for setpoint adjustment of control point from multiple sources Percent RLA Output - provides % RLA output Condenser Pressure Output - A hardwire output signal of condenser pressure, or differential pressure between the evaporator and condenser is provided. Operating Status: The following hardwire binary outputs are available: Compressor running relay Alarm relay - manual reset Alarm relay - auto reset Limit warning relay Purge alarm relay Head relief request relay Maximum capacity relay Evaporator Proof of Flow - Thermal Dispersion A factory provided, field installed thermal dispersion type proof of flow switch (IFM) is provided. The thermal dispersion controller is mounted in the chiller control panel, the piping probe and wiring is shipped lose for field installation in the ship with components box. Follow the installation instructions in the chiller installation manual. Reference specific IFM Installation manual (PART-SVN223*-EN) notes shipped with your rupture guard /contact local Trane sales office SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 11 of 25 Condenser Proof of Flow - Thermal Dispersion A factory provided, field installed thermal dispersion type proof of flow switch (IFM) is provided. The thermal dispersion controller is mounted in the chiller control panel, the piping probe and wiring is shipped lose for field installation in the ship with components box. Follow the installation instructions in the chiller installation manual. Reference specific IFM Installation manual (PART-SVN223*-EN) notes shipped with your rupture guard /contact local Trane sales office Paint All CenTraVac(TM) painted surfaces are coated with a primer and an air-dry beige primer-finisher prior to shipment. Isolation All units ship with neoprene isolator pads as standard, except when spring isolators are chosen. Enough pads are provided to cover the area under the chiller supports. Shipment All units are of hermetic design, leak tested, charged to 5.00 psi and shipped as a single factory assembled package. Full oil charge shipped in oil sump. Refrigerant shipped to jobsite from refrigerant manufacturer. The entire chiller is shrink wrapped for protection. Unit Mounted Starter Wye Delta-Reduced Voltage, NEMA 1A (vented) enclosure with a gasket. Starter factory mounted and completely prewired to compressor motor and control panel. Factory run testing assures proper circuitry and operational reliability. The Wye Delta starter is a reduced voltage starter and therefore draws ~ 33% of locked rotor amps (LRA), and the motor acceleration time is 5-12 seconds typically. The starter is designed and tested in accordance with UL 1995 Features include: 115 volt control power transformer to power chiller unit controller, purge and oil system. Therefore, with line power, no other power is needed for auxiliary equipment on the chiller. Environmental specification: Operation from sea level to 6000 ft (1829 m). Operating ambient temperature range 32.0 F to 104.0 F. Non-operating ambient temperature range -40.0 F to 158.0 F. Relative humidity, non-condensing 5% to 95% through the ambient temperature range. Voltage utilization ±10 % Top of starter includes access area for a wiring entrance area. Bottom entry for line power is not available. Terminal block connection is standard. Circuit breakers may be included as an option. See the following submittal pages for disconnect ratings and lug information on these optional disconnects if offered. Starter installer responsibilities The following are considered functions normally required of the equipment installer for unit mounted starters. Remove access area panel for line side wiring. The upper right quadrant of the starter provides recommended access to starter/disconnect lugs. The starter can accommodate top line power entry only. Provide and install field wiring to line side lugs of starter. Required Installer Responsibilities The following are considered functions normally required of the equipment installer./n Install unit on a foundation with flat support surfaces level within 1/16" and of sufficient length to support concentrated loading. (Spring isolators should be considered whenever chiller installation is planned for an upper story location.) Place isolation pads or optional spring type isolators provided by the chiller manufacturer under the unit. When spring isolators are chosen, no pads are provided. Install unit per applicable Trane Installation Manual. Complete all water and electrical connections. Where specified, provide and install valves in water piping upstream and downstream of the evaporator and condenser water boxes as means of isolating shells for maintenance and to balance and trim system. SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 12 of 25 Furnish and install a flow switch with timer or equivalent device in both the chilled water and condenser water piping properly interlocked to insure that unit can operate only when water flow is established. Furnish and install taps for thermometers and pressure gauges in water piping adjacent to inlet and outlet connections of both evaporator and condenser. Furnish and install drain valves to each water box. Install vent cocks on each water box. Furnish and install strainers upstream of chiller evaporator and condenser bundles to protect tubes from potential damage caused by debris in the circulating water. Note: Failure to install strainers in all water piping entering the chiller could result in tube plugging conditions that could damage unit components. If the circulating pumps are immediately upstream of the chiller bundles, then the strainer can be installed immediately ahead of the pumps. If the circulating pumps are downstream of the chiller bundles, then the strainers should be installed immediately ahead of the chiller bundles. Furnish sufficient refrigerant 25.0 lb per machine and dry nitrogen 50.0 lb per machine for pressure testing under manufacturer's supervision. Start-up unit under supervision of a qualified Trane field engineer. Where specified, insulate evaporator and any other portions of machine required to prevent sweating under normal operating conditions. Water connection piping must not transfer forces to the chiller. Because of cumulative tolerances in manufacture and field installation, prepiping of water connections closer than 36" is not recommended. Any problems associated with prepiping of water connections closer than 36" to the chiller are the responsibility of the installing contractor. Furnish and install vent lines for rupture disk and purge venting to atmosphere per ASHRAE 15 and unit installation manual. If RuptureGuard-Relief Valve option is ordered, remove factory rupture disk and install RuptureGuard-Relief Valve per the IOM manual. In some chiller configurations the RuptureGuard may not bolt directly to the chiller flange. Locally sourced and approved piping may be required between the chiller and the RuptureGuard. Field Disassembly With chillers that may require field disassembly (for example due to clearance concerns during unit installation) reference the Disassembly and Reassembly manual and your Trane Sales representative prior to the order being placed. Caution: if certain components are removed in the field, for example the economizer, the necessary components (gaskets, seals, etc.) are not provided as standard. Leak-Tight Warranty The CenTraVac chiller features a 5-year limited Leak-Tight Warranty which is valid for the lesser of 60 months from initial start-up or 66 months from date of shipment. The limited Leak-Tight Warranty covers models CVHE/F/L, CVHS, CVHM and CDHF chillers installed in the United States or Canada. The Company's obligations and liabilities under this warranty are limited to furnishing replacement refrigerant; no other parts or labor are covered under this limited warranty. No liability whatever shall attach to the Company until appropriate actions have been taken (acceptable to Company) to eliminate the source of the leak, and then said liability shall be limited to furnishing the replacement refrigerant. If the chiller is placed under a comprehensive Trane service and maintenance agreement (Trane Select Agreement or better) prior to the expiration of the standard Leak-Tight Warranty, the protection against refrigerant loss shall continue under the Trane Select Agreement for as long as an active Trane Select Agreement remains in effect without interruption. If a 10-Year Parts, Labor and Refrigerant Warranty was purchased for the chiller and the chiller is placed under a Trane Select Agreement (or better) prior to the expiration of the 10-Year Parts, Labor and Refrigerant Warranty, the protection against refrigerant loss shall continue under the Trane Select Agreement for as long as an active Trane Select Agreement remains in effect without interruption SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 13 of 25 Unit Dimensions - Centrifugal Water Chiller Item: A1 Qty: 1 Tag(s): CVHE450 UNLESS OTHERWISE SPECIFIED DIMENSIONAL TOLERANCE +/-1/2".COOLING COND CONNS ARE STRAIGHT OUT THE END OF THE WATER BOX.WATER BOX DRAIN AND VENT LOCATIONS ARE SHOWN ON THE WATER BOX END PLATES.EVAPORATORCOOLING COND8"8"VICTAULICVICTAULICIN REAR OUT FRONTIN BOTTOM OUT TOPCUSTOMER NOTES:FLOW DIRECTIONCONN TYPECONN DIASHELL TYPETOP VIEWLEFT SIDE VIEWFRONT VIEWRIGHT SIDE VIEWGRAPHICS ON SUBMITTAL ARE SIMPLIFIED TO SHOW MAJOR ENVELOPE COMPONENTS.UNIT STRUCTURE AND SUBCOMPONENTS MAY BE REMOVED FOR CLARITY. SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 14 of 25 Unit Dimensions - Centrifugal Water Chiller Item: A1 Qty: 1 Tag(s): CVHE450 7 3/4"25 3/16"61 5/8"1 5/8"135 7/8"UNLESS OTHERWISE SPECIFIED DIMENSIONAL TOLERANCE +/-1/2".COOLING COND CONNS ARE STRAIGHT OUT THE END OF THE WATER BOX.WATER BOX DRAIN AND VENT LOCATIONS ARE SHOWN ON THE WATER BOX END PLATES.EVAPORATORCOOLING COND8"8"VICTAULICVICTAULIC Unit MountedWye-delta StarterPurge IN REAR OUT FRONTIN BOTTOM OUT TOPCVHE 450 Nominal tons500 Ton short shell evap.500 Ton short shell cond.Without additional condenserCUSTOMER NOTES:TOP VIEWEvaporatorCondenserEconomizerCompressorFLOW DIRECTIONCONN TYPECONN DIASHELL TYPEAdaptiView Control Paneltouch screen is field installed(See accessory drawing for details)RuptureDisk 3" NPTGRAPHICS ON SUBMITTAL ARE SIMPLIFIED TO SHOW MAJOR ENVELOPE COMPONENTS.UNIT STRUCTURE AND SUBCOMPONENTS MAY BE REMOVED FOR CLARITY. SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 15 of 25 Unit Dimensions - Centrifugal Water Chiller Item: A1 Qty: 1 Tag(s): CVHE450 20 3/4"96 5/8"7 15/16"10 1/2"7 5/16"12 3/4"135"UNLESS OTHERWISE SPECIFIED DIMENSIONAL TOLERANCE +/-1/2".COOLING COND CONNS ARE STRAIGHT OUT THE END OF THE WATER BOX.WATER BOX DRAIN AND VENT LOCATIONS ARE SHOWN ON THE WATER BOX END PLATES.EVAPORATORCOOLING COND8"8"VICTAULICVICTAULICIN REAR OUT FRONTIN BOTTOM OUT TOPCVHE 450 Nominal tons500 Ton short shell evap.500 Ton short shell cond.Without additional condenserCUSTOMER NOTES:FRONT VIEWFLOW DIRECTIONCONN TYPECONN DIASHELL TYPEGRAPHICS ON SUBMITTAL ARE SIMPLIFIED TO SHOW MAJOR ENVELOPE COMPONENTS.UNIT STRUCTURE AND SUBCOMPONENTS MAY BE REMOVED FOR CLARITY. SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 16 of 25 Unit Dimensions - Centrifugal Water Chiller Item: A1 Qty: 1 Tag(s): CVHE450 44 1/2"30"15 3/8"45 1/4"44 13/16"48 1/4"27 5/8"8 7/8"62"21 1/2"UNLESS OTHERWISE SPECIFIED DIMENSIONAL TOLERANCE +/-1/2".COOLING COND CONNS ARE STRAIGHT OUT THE END OF THE WATER BOX.WATER BOX DRAIN AND VENT LOCATIONS ARE SHOWN ON THE WATER BOX END PLATES.EVAPORATORCOOLING COND8"8"VICTAULICVICTAULICIN REAR OUT FRONTIN BOTTOM OUT TOPCVHE 450 Nominal tons500 Ton short shell evap.500 Ton short shell cond.Without additional condenserCUSTOMER NOTES:LEFT SIDE VIEWFLOW DIRECTIONCONN TYPECONN DIASHELL TYPEGRAPHICS ON SUBMITTAL ARE SIMPLIFIED TO SHOW MAJOR ENVELOPE COMPONENTS.UNIT STRUCTURE AND SUBCOMPONENTS MAY BE REMOVED FOR CLARITY. SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 17 of 25 Unit Dimensions - Centrifugal Water Chiller Item: A1 Qty: 1 Tag(s): CVHE450 98 11/16"16 1/8"78"14 1/2"17 3/8"UNLESS OTHERWISE SPECIFIED DIMENSIONAL TOLERANCE +/-1/2".COOLING COND CONNS ARE STRAIGHT OUT THE END OF THE WATER BOX.WATER BOX DRAIN AND VENT LOCATIONS ARE SHOWN ON THE WATER BOX END PLATES.EVAPORATORCOOLING COND8"8"VICTAULICVICTAULICIN REAR OUT FRONTIN BOTTOM OUT TOPCVHE 450 Nominal tons500 Ton short shell evap.500 Ton short shell cond.Without additional condenserCUSTOMER NOTES:RIGHT SIDE VIEWFLOW DIRECTIONCONN TYPECONN DIASHELL TYPEGRAPHICS ON SUBMITTAL ARE SIMPLIFIED TO SHOW MAJOR ENVELOPE COMPONENTS.UNIT STRUCTURE AND SUBCOMPONENTS MAY BE REMOVED FOR CLARITY. SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 18 of 25 Weight, Clearance & Rigging Diagram - Centrifugal Water Chiller Item: A1 Qty: 1 Tag(s): CVHE450 WEIGHTS AND CENTER OF GRAVITY LEFT FRONT LEFT REAR RIGHT FRONT RIGHT REAR LEFT MIDDLE RIGHT MIDDLE LOCATION ISOLATOR LOAD*VENDOR P/N TRANE P/N ISOLATOR COLOR SHIPPING OPERATING SPRING ISOLATOR SELECTION WEIGHTS 19067.0 lb17144.0 lb 4599.0 lb 3621.0 lb 4867.0 lb 5980.0 lb N/A N/A UNIT CENTER OF GRAVITY CG X (DIMENSION FROM FRONT TO REAR) CG Y (HEIGHT DIMENSION FROM FLOOR) CG Z (DIMENSION FROM RIGHT TO LEFT) RIGHT FRONT ISOLATOR MOUNTING HOLE X Y Z COMPONENT WEIGHT* NAMEPLATE PRODUCT DESCRIPTION: COMPRESSOR WEIGHT MOTOR WEIGHT STARTER WEIGHT SUCTION ELBOW WEIGHT ECONOMIZER WEIGHT EVAPORATOR WEIGHT EVAPORATOR WATERBOXES WEIGHT CONDENSER WEIGHT CONDENSER WATERBOXES WEIGHT HEAT RECOVERY CONDENSER WEIGHT HEAT RECOVERY CONDENSER WATERBOXES WEIGHT AUXILIARY CONDENSER WEIGHT AUXILIARY CONDENSER WATERBOXES WEIGHT MISCELLANEOUS WEIGHT 57.000 in 28.000 in 45.000 in CVHE TECU 500 460 TECU 233 050S 450 228 580 050S MODL EVTM CDBS VOLT CDTM CPKW EVSZ ORSZ NTON CPIM EVBS CDSZ400 PTON 300.00 tons BOTTOM OF THIS HOLE IS 0,0,0 POINT FOR CENTER OF GRAVITY DIMENSIONS 5418.0 lb 1732.0 lb 557.0 lb 280.0 lb 635.0 lb 4025.0 lb 630.0 lb 2454.0 lb 399.0 lb N/A N/A N/A N/A 1013.0 lb *ALL PUBLISHED WEIGHTS ACCURATE TO +/- 10 % SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 19 of 25 Weight, Clearance & Rigging Diagram - Centrifugal Water Chiller Item: A1 Qty: 1 Tag(s): CVHE450 DIMENSION INCLUDES TUBESHEETS FRONT OF UNIT SEE HOLE DETAIL REFERENCED TUBE PULL IS GOOD FOR BOTH EVAPORATOR AND CONDENSER TUBE PULL CLEARANCE DIMENSION TO RIGHT HAND TUBE PULL SHOWN, APPLY LEFT END FOR LEFT HAND TUBE PULL. CLEARANCE SPACE DIMENSION INCLUDES TUBESHEETS FRONT OF UNIT SEE HOLE DETAIL REFERENCED TUBE PULL IS GOOD FOR BOTH EVAPORATOR AND CONDENSER TUBE PULL CLEARANCE DIMENSION TO RIGHT HAND TUBE PULL SHOWN, APPLY LEFT END FOR LEFT HAND TUBE PULL. CLEARANCE SPACE HOLE DETAIL TYP 2" TYP (51mm) 1 3/16" TYP (30mm) EVAPORATOR TUBESHEET 2 5/8" TYP (67mm) 5" TYP (127mm) 135" 62" 141" 34 1/4" 44 1/2" 320 1/2" 4 MAXIMUM OPERATING MAXIMUM SHIPPING FOLLOW NEC SECTION 110 AND OTHER APPLICABLE LOCAL CODES FOR CLEARANCES IN FRONT OF ELECTRICAL ENCLOSURES. 7 1. HEAVY OBJECTS! DO NOT USE CABLES (CHAINS OR SLINGS) EXCEPT AS SHOWN. EACH OF THE CABLES (CHAINS OR SLINGS) USED TO LIFT THE UNIT MUST BE CAPABLE OF SUPPORTING THE ENTIRE WEIGHT OF THE UNIT. LIFTING CABLES (CHAINS OR SLINGS) MAY NOT BE OF THE SAME LENGTH. ADJUST AS NECESSARY FOR EVEN UNIT LIFT. OTHER LIFTING ARRANGEMENTS MAY CAUSE EQUIPMENT OR PROPERTY-ONLY DAMAGE. FAILURE TO PROPERLY LIFT UNIT MAY RESULT IN DEATH OR SERIOUS INJURY. SEE DETAILS BELOW. 2. IMPROPER UNIT LIFT! TEST LIFT UNIT APPROXIMATELY 24 INCHES TO VERIFY PROPER CENTER OF GRAVITY LIFT POINT. TO AVOID DROPPING OF UNIT, REPOSITION LIFTING POINT IF UNIT IS NOT LEVEL. FAILURE TO PROPERLY LIFT UNIT COULD RESULT IN DEATH OR SERIOUS INJURY OR POSSIBLE EQUIPMENT OR PROPERTY-ONLY DAMAGE. 3. ATTACH SAFETY CHAIN OR CABLE AS SHOWN WITHOUT TENSION, NOT AS A LIFTING CHAIN OR CABLE, BUT TO PREVENT THE UNIT FROM ROLLING. 4. DO NOT FORKLIFT THE UNIT TO MOVE OR LIFT. 5. LIFTING HOLES PROVIDED ON CHILLER TO ATTACH CABLES (CHAINS OR SLINGS). 6. 36" (900 MM) RECOMMENDED CLEARANCE ABOVE HIGHEST POINT OF COMPRESSOR. OR CABLES SAFETY CHAINS 8. SPECIFIC SHIPPING AND OPERATING WEIGHTS OF THE SUBMITTED CHILLER ARE PROVIDED IF THE CENTRIFUGAL CHILLER SELECTION WAS ENTERED IN TOPSS. DETAILED LOAD POINT AND SPRING ISOLATOR APPLICATION WEIGHTS ARE AVAILABLE FROM "CENTRAVAC ISOLATOR SELECTION REPORT" AVAILABLE FROM THE REPORT GENERATOR OF THE TRANE TOPSS CHILLER SELECTION PROGRAM. CONTACT YOUR LOCAL TRANE SALES ENGINEER IF THIS DATA IS REQUIRED. (SEE NOTE 8 ABOVE) 17144.0 lb 19067.0 lb X .88 (22mm) DIA HOLES FOR ANCHORING UNIT SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 20 of 25 Accessory - Centrifugal Water Chiller Item: A1 Qty: 1 Tag(s): CVHE450 7 1/2" 16" 20" 6 5/8" 7/8" DIA HOLE 1 1/8" DIA HOLE 26 1/8" 32 3/4" 6 HOLES FOR CONTROL WIRING CONDUITS 6 3/4" 5 XTYPICAL HOME POSITION REF-BOTTOM FRONT OF PANEL DOOR NOTE: DISPLAY CAN MOVE TO AN INFINITE NUMBER OF POSITIONS. TOP VIEW AVAILABLE LOWEST POSITION ADAPTIVIEW CONTROL PANEL SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 21 of 25 Accessory - Centrifugal Water Chiller Item: A1 Qty: 1 Tag(s): CVHE450 MAX DOOR SWING 145° & 38 1/4" [972mm] MAX D OOR SWING145° & 38 1/4" [972mm] 60" 33 3/8" 38"MAX D OOR SW ING145° & 38 1/4" [972mm ] 16 5/16"13 7/16" 6 5/16" 29 7/16" ELECTRICAL ENTRANCE 7" x 14" TOP ALLOW MIN. FRONT WORKING SPACE CLEARANCE PER NEC ARTICLE 110 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS. CBIC = CIRCUIT BREAKER HIGH INTERRUPT CAPACITY 4DP 296 65,000 65,000 (2) 2/0-250 OR (1) 2/0-500 WYE-DELTA STARTERS CBIC 25" POWER FACTOR CORRECTION CAPACITORS, WHEN SELECTED, ARE NOT INCLUDED IN THE UL SHORT CIRCUIT RATING OF THE STARTER. DOOR SWINGS TO THE LEFT FOR A MAX OF 145 DEGREES & 38 1/4" UNIT MOUNTED WYE-DELTA STARTER THE NON-FUSED DISCONNECT OR CIRCUIT BREAKER IS DESIGNED FOR USE AS A SERVICE DISCONNECT ONLY. TOP FRONT CONNECTION PANEL AIC AMPS BREAKERSIZE MAX CONN RATINGS (RMS SYMETRICAL AMPS) SHORT CIRCUIT CURRENT LINE CONNECTION LUGS LENGTH INTERNAL WIRE VIEW ELEVATION RLA SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 22 of 25 Field Wiring - Centrifugal Water Chiller Item: A1 Qty: 1 Tag(s): CVHE450 CONDENSER REFRIGERENT PRESSURE OUTPUT PERCENT RLA COMPRESSOR OUTPUT EXTERNAL CURRENT LIMIT SETPOINT EXTERNAL CHILLED WATER SETPOINT CHILLED WATER RESET INPUT OR 2-10V OUTPUT (2 WIRES) 2-10V INPUT (2 WIRES)9 1010 10 10 9 9 8 8 8 8 8 8 8 PURGE REMOTE ALARM MAXIMUM CAPACITY RELAY REMOTE ALARM RELAY (LATCHING) HEAD RELIEF REQUEST RELAY LIMIT WARNING INDICATOR COMPRESSOR RUNNING RELAY REMOTE ALARM RELAY (NON-LATCHING) REQUIRED. CONTACTS ARE NO/NC RATINGS - 2.88 INDUCTIVE 1/3 H.P.(.25 kW) AT 115 VAC. 2 OR 3 WIRES(N.O. &/OR N.C.), 115 VAC CIRCUIT, SEPARATE 115 VAC POWER SUPPLY IS8 MOUNTED (SEE NAMEPLATE) STARTER UNIT VOLTAGE LINE TRACER OR OTHER TRANE REMOTE DEVICE (COMMUNICATIONS INTERFACE) SHIELDED PAIR. 30 VOLT OR LESS CIRCUIT. MAX LENGTH 1500 FT. BELDON TYPE 8760 RECOMMENDED. (2 WIRES) 12 12 LOW VOLTAGE (30V MAX) DO NOT RUN WITH HIGHER VOLTAGE CIRCUITS ARE N.O. CONTACT RATING - 2.88 INDUCTIVE 1/3 H.P.(.25 kW) AT 115 VAC OPTIONAL. 2 WIRES, 115 VAC CIRCUIT, SEPARATE POWER SUPPLY IS REQUIRED. MINIMUM CONTACT RATING AT 115 VAC - 2.88 INDUCTIVE 1/3 H.P.(.25 kW) AT 115 VAC REQUIRED. 2 WIRES, 115 VAC CIRCUIT, SEPARATE POWER SUPPLY IS REQUIRED. CONTACTS ALL CUSTOMER CONTROL CIRCUIT WIRING MUST HAVE A MINIMUM RATING OF 150 VOLTS. EVAPORATOR AND CONDENSER FLOW SWITCHES ARE REQUIRED. THEY MUST BE INSTALLED AND WIRED TO THE TRANE PANEL BY THE INSTALLING CONTRACTOR. CAUTION - DO NOT ENERGIZE UNIT UNTIL CHECK-OUT AND START-UP PROCEDURES HAVE BEEN COMPLETED. * CONNECTION DIAGRAMS ARE AVAILABLE AT THE WEBPAGE SHOWN IN THE MECHANICAL SPECIFICATIONS SECTION OF THIS SUBMITTAL. DASHED LINES INDICATE RECOMMENDED FIELD WIRING BY OTHERS. CHECK SALES ORDER TO DETERMINE IF WIRING IS REQUIRED FOR SPECIFIC OPTIONS. THE UNIT CONTROL PANEL (ADAPTIVIEW) SUPPLIES A CONTACT SHOWN BELOW. MAXIMUM FUSE SIZE PER DEVICE - 15 AMPS. OUTPUT TO CONTROL THE CUSTOMER SUPPLIED DEVICES CHILLED WATER PUMP STARTER CONDENSER WATER PUMP STARTER CHILLED WATER PUMP PUMP WATER COND COND 6 7 PURCHASE OF SWITCHES FROM TRANE IS OPTIONAL. 1. 2. REQUIRED 5. 3. 6 7 NOTES: EMERGENCY STOP NORMAL/TRIP (CONTACT) EXTERNAL AUTO/STOP (CONTACT) 115 VOLTS CONTROL VOLTAGE FRONT ELEVATION EVAP PANEL CONTROL LEAVING CONDENSER WATER LEAVING CHILLED WATER REMOTE DISCONNECTS AND FOLLOW LOCK OUT FAILURE TO DO THE ABOVE BEFORE SERVICING COULD RESULT IN DEATH OR SERIOUS INJURY. HAZARDOUS VOLTAGE! AND TAG PROCEDURES BEFORE SERVICING. INSURE THAT ALL MOTOR CAPACITORS HAVE DISCHARGED STORED VOLTAGE. UNITS WITH VARIABLE SPEED DRIVE, REFER TO DRIVE INSTRUCTIONS FOR CAPACITOR DISCHARGE. DISCONNECT ALL ELECTRIC POWER INCLUDING WARNING DAMAGE TO THE EQUIPMENT. USE COPPER CONDUCTORS ONLY! CAUTION FAILURE TO DO SO MAY CAUSE OTHER TYPES OF CONDUCTORS. UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT COUNTRIES APPLICABLE NATIONAL AND/OR LOCAL REQUIREMENTS SHALL APPLY. (NEC), STATE AND LOCAL REQUIREMENTS. OUTSIDE THE UNITED STATES, OTHER ALL FIELD WIRING MUST BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE4. 5-LEAD JACKETED CABLE DETECTION SENSORS REQUIRED COND WATER FLOW 5-LEAD JACKETED CABLE DETECTION SENSORS OPTIONAL EVAP WATER FLOW SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 23 of 25 Field Wiring - Centrifugal Water Chiller Item: A1 Qty: 1 Tag(s): CVHE450 (SEE UNIT NAMEPLATE) LINE VOLTAGE CUSTOMER SUPPLIED L1GND L3L2 L1G L2 L3 2Q1 OR 2S1 DISCONNECT OR 2X3 TERMINAL BLOCK PUMP MOTOR; 1PH 3/4 HP, 11.7 FULL LOAD AMPS AT 115VAC. 14 AWG MAX WIRE SIZE. TWISTED, SHIELDED PAIR, 30VDC, MAX LENGTH 1500 FT 24VDC, 12MA RESISTIVE LOAD, 14 AWG MAX WIRE SIZE (BELDEN TYPE 8760 RECOMMENDED) CIRCUIT PROTECTED AT 20A, 115VAC 1PH, 10 AWG MAX WIRE SIZE CONTACT RATING; 2.88A INDUCTIVE, 1/3 HP, 0.25KW AT 115VAC. 14 AWG MAX WIRE SIZE. * TAPPED CONTROL CONDUCTORS 5S1*, 5S2*, 3B* AND 4B* 5S3 THRU 5S8 WB4 ALL REMAINING LLID TERMINALS 9A* AND 10A* 1A* SUPPLY AND MOTOR LEADS WIRE NO OR DEVICE 4000VA AT 115VAC, 8 AWG MAX WIRE SIZE SEE NAMEPLATE; MINIMUM CIRCUIT AMPACITY FIELD WIRING CIRCUIT SELECTION INFORMATION AND START-UP PROCEDURES HAVE BEEN COMPLETED. DO NOT ROUTE LOW VOLTAGE (30V) WITH CONTROL VOLTAGE (115V) AND DO NOT POWER UNIT UNTIL CHECK-OUT DASHED LINES INDICATE FIELD WIRING BY OTHERS. WIRE NUMBERS SHOWN ARE RECOMMENDED BY TRANE. 2. 1. NOTES: 2A* AND GRN/YEL 4000VA AT 115VAC, 8 AWG MAX WIRE SIZE (WITHOUT OPTIONAL CPTR) 2A* AND GRN/YEL CIRCUIT PROTECTED AT 20A, 115VAC 1PH, 10 AWG MAX WIRE SIZE (WITH OPTIONAL CPTR) DEVICE PREFIX CODE = MAIN UNIT CONTROL PANEL DEVICE = REMOTE MOUNTED DEVICE = UNIT MOUNTED DEVICE 1 2 4 = CUSTOMER PROVIDED DEVICE5 AND TAG PROCEDURES BEFORE SERVICING. FAILURE TO DO SO MAY CAUSE DAMAGE TO THE EQUIPMENT. OTHER TYPES OF CONDUCTORS. UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT FAILURE TO DO THE ABOVE BEFORE SERVICING COULD RESULT IN DEATH OR SERIOUS INJURY. INSTRUCTIONS FOR CAPACITOR DISCHARGE. VARIABLE SPEED DRIVE, REFER TO DRIVE DISCHARGED STORED VOLTAGE. UNITS WITH INSURE THAT ALL MOTOR CAPACITORS HAVE USE COPPER CONDUCTORS ONLY! CAUTION HAZARDOUS VOLTAGE! REMOTE DISCONNECTS AND FOLLOW LOCK OUT DISCONNECT ALL ELECTRIC POWER INCLUDING WARNING TRANE SUPPLIED UNIT MOUNTED LOW VOLTAGE WYE-DELTA STARTER PANEL SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 24 of 25 Field Wiring - Centrifugal Water Chiller Item: A1 Qty: 1 Tag(s): CVHE450 NH 5K1 5K2 1A5 J2-6 1A5 J2-3 1A5 J2-4 1A5 J2-1 EVAPORATOR WATER CONDENSER WATER 1A13 J2-1 1A13 J2-2 1A13 J2-3 1A13 J2-4 5S3 5S4 EXTERNAL AUTO STOP (REMOVE JUMPER 1W2 IF USED)1W2 1W3EMERGENCY STOP (REMOVE JUMPER 1W3 IF USED) PUMP RELAY OPTIONAL PUMP RELAY REQUIRED GND GRN/YEL 115VAC 15A CUSTOMER PROVIDED POWER MAIN UNIT CONTROL PANEL TERMINAL CONNECTIONS 1X1-G EN1 WB16 FACTORY CONNECTED IN CONTROL PANEL 1A22 ETHERNET 1A2-J4 POWER CUSTOMER TO CONNECT ETHERNET AND POWER CABLES TO 4A2 ADAPTIVIEW DISPLAY MONITOR (DEFAULT) OPTIONAL OPTIONAL OPTIONAL 1A9 J2-1 1A9 J2-4 1A9 J2-3 1A9 J2-6 1A8 J2-10 1A8 J2-12 1A8 J2-6 1A8 J2-4 1A5 J2-12 CHILLER MAXIMUM CAPACITY CHILLER RUNNING CHILLER HEAD RELIEF REQUEST 5H10 OPTIONAL 5H11 CHILLER LIMIT WARNING INDICATOR 5H7 OPTIONAL 5H6 OPTIONAL (ALTERNATE) TO ANY ALTERNATE ALARM OR STATUS DEFAULT OUTPUTS MAY BE REPROGRAMMED CHILLER ALARM INDICATOR 1A9 J2-9 1A9 J2-7 1A8 J2-1 1A8 J2-7 1A8 J2-9 1A8 J2-3 OPTIONAL 5H15 CHILLER MAR CHILLER MMR PURGE ALARM (LATCHING) ALARM INDICATOR (DEFAULT) 5H2 OPTIONAL 5H4 5H1 OUTPUT LISTED BELOW (NON-LATCHING) INDICATOR ALARM INDICATOR (DEFAULT) (DEFAULT) INDICATOR (DEFAULT) INDICATOR (DEFAULT) INDICATOR (DEFAULT) CONDENSER REFRIGERANT PRESSURE OR EVAPORATOR/CONDENSER DIFFERENTIAL PRESSURE OUTPUT CURRENT LIMIT SETPOINT EXTERNAL CHILLED 2-10VDC OR 4-20MA 2-10VDC EXTERNAL 1A16 J2-3 1A16 J2-6 1A16 J2-5 1A15 J2-6 1A16 J2-2 %%% RLA COMPRESSOR OUTPUT 2-10VDC 2-10VDC (GENERIC BAS)1A15 J2-3 1A15 J2-4 1A15 J2-1 WATER SETPOINTAND TAG PROCEDURES BEFORE SERVICING. FAILURE TO DO SO MAY CAUSE DAMAGE TO THE EQUIPMENT. OTHER TYPES OF CONDUCTORS. UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT FAILURE TO DO THE ABOVE BEFORE SERVICING COULD RESULT IN DEATH OR SERIOUS INJURY. INSTRUCTIONS FOR CAPACITOR DISCHARGE. VARIABLE SPEED DRIVE, REFER TO DRIVE DISCHARGED STORED VOLTAGE. UNITS WITH INSURE THAT ALL MOTOR CAPACITORS HAVE USE COPPER CONDUCTORS ONLY! CAUTION HAZARDOUS VOLTAGE! REMOTE DISCONNECTS AND FOLLOW LOCK OUT DISCONNECT ALL ELECTRIC POWER INCLUDING WARNING 1K26-4 1X1-5 PUMP INTERLOCK EVAPORATOR WATER OPTIONAL AUX 5S13 4 BY CUSTOMER TO BE INSTALLED 4R17 EVAPORATORGRY BLK BRN BLU WHT WB11 DETECTION SENSORWATER FLOW4R172 3 1 5 GRY BLK BRN BLU WHT1K26-17 1K26-18 1K26-19 1K26-20 1K26-21 4 1K27-4 1X1-6 PUMP INTERLOCK CONDENSER WATER REQUIRED AUX 5S14 1K27-21 1K27-20 1K27-19 1K27-18 1K27-17 WHT BLU BRN BLK GRY 5 4 1 3 2 4R18 WATER FLOWDETECTION SENSORWB12 WHT BLU BRN BLK GRY CONDENSER4R18 TO BE INSTALLED BY CUSTOMER 4 58A 5W 59A 5T 1K26 EVAPORATOR AND/OR 1K27 CONDENSER WATER FLOW DETECTION CONTROLLERS: ALL COMPONENTS ARE SUPPLIED BY TRANE. THE CONTROLLERS ARE FACTORY INSALLED IN THE MAIN UNIT CONTROL PANEL. 4R17 EVAPORATOR AND/OR 4R18 CONDENSER WATER FLOW DETECTION SENSORS ARE CUSTOMER INSTALLED AND WIRED TO THE CONTROLLERS WITH SUPPLIED WB11 AND/OR WB12 JACKETED CABLES. THE USE OF SEPARATE WATER PUMP CONTROL RELAYS WITH AUX INTERLOCK CONTACTS WIRED AS SHOWN ARE REQUIRED. 4 ETHERNET 1 1A27EN2 BACNET OVER ETHERNET 4 4 SLC - Rock Road Jail Chiller Repl March 17, 2020 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 25 of 25 Field Installed Options - Part/Order Number Summary This is a report to help you locate field installed options that arrive at the jobsite. This report provides part or order numbers for each field installed option, and references it to a specific product tag. It is NOT intended as a bill of material for the job. Product Family - Centrifugal Water Chiller Item Tag(s) Qty Description Model Number A1 CVHE450 1 Centrifugal Chiller ( CTV ) CVHE0450 Field Installed Option Description Part/Ordering Number Thermal dispersion flow switch (IFM) - Field Installed Thermal dispersion flow switch (IFM) - Field Installed