Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval - Shingles
1/3/2020 Florida Building Code Online s ! ✓ d -. t r° � r x t i Lx*.i { lac U. L a¢aH'i .., ...�"mow., .. .. Y2 .,',✓w d.,.�.� rL�z�v�� e„sCCa�+u-p �5wxNF+4��z�L"soagnR. v, BCIS Home Log In User Registration Hot Topics j submit surcharge "�, Stats a Fads Publications Contact Us BCIS Site Map Links ! Search db'r ,,$epProduct Approval is°' USER: Public User Product Approval Menu > Protluct or Application Search > Application List> Application Detail FL # FL10674-R15 Application Type 7r Revilsion Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 greg. keeler@owenscorning.com Authorized Signature Greg Keeler greg. keeler@owenscorn ing.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419)376-8360 mel.sancrant@owenscomig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report -Hardcopy Received Florida Engineer or Architect Name who developed the Robert J.M. Niernmen Evaluation Report Florida License PE -59166 Quality Assurance Entity PRI Construction Materials Technologies, LLC. Quality Assurance Contract Expiration Date 01/01/2099 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL10674 RIS COI 2019 01 COI NIEMINEN gdf Standard ASTM D1970 ASTM D3161 ASTM D3462 ASTM D7158 Year 2015 2016 2010 2011 hftps://www.floridabuilding.org/pr/pr_app_dfl.aspx?param=wGEVXQwtDgtBNbEYSV%2boQTe/a2b6w7ahReglCQ8ucR6ixEDL76gG32Q9MA%3d%3d 1/2 1/3/2020 H Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Sus of Products Florida Building Code Online Method 1 Option D 08/15/2019 08/15/2019 08/21/2019 10/15/2019 FL # Model, Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3 -tab, 4 -tab, 5 -tab, laminated, starter and hip &ridge shingles Shingles and Starters Limits of Use Installation Instructions Approved for use in HVHZ: No FL1.0674 R15 II 2019 08 FINAL ER OC ASPHALT SHINGLES FL10674-RSS.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE - 59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER, Section S. 1 Evaluation Reports FL10674 R15 AE 2019 08 FINAL ER OC ASPHALT SHINGLES FL10674-R15 pdf Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stene Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an WEED employer. Cogynght 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant to section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The smalls provided may be used for official communication with the license. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 2hec6 -ns securityntmr cres I https://www.floridabuilding.org/pr/pr_app_ d.aspx?param=wGEVXQwtDgtBNbEYSV%2boQT%2b6w7ahReglCQ8ucR6ixEDL76gG32Q9MA%3d%3d 2/2 MEMO 1 etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY Owens Corning Evaluation Report 037940.02.12-R10 One Owens Corning Parkway FL10674-R15 Toledo, OH 43659 Date of Issuance: 02/06/2012 (740) 404-7829 Revision 10: 08/15/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: oNj "•.., - Pt � } Robert J.M. NLeminen, P.E. The facsimile seal appearing was authorized by Robert "•, �'ti c: Nieminen, P.E. on 08/15/2019. This does not serve as an Florida Registration No. 59166, Florida DCAANE2983,. 5. ` electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOI etc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO [etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMOI etc. nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018, NEMO ETC, LLC ROOFING SYSTEMS EVALUATION: 4.1 ACCESSORY STARTERS: 4.1.1 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter are starter strips for asphalt roof shingles. Meets ASTM D3462. 4.1.2 Starter Shingle Roll is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen starter strip, nominal 7.2 -inch wide x 33 -ft 4 -inch long roll, for use with asphalt shingles. Meets ASTM D1970. 4.2 ASPHALT SHINGLES: 4.2.1 Classic" and Supreme` are fiberglass reinforced, 3 -tab asphalt roof shingles. Meets ASTM D3462. 4.2.2 Berkshire' are fiberglass reinforced, 4 -tab asphalt roof shingles. Meets ASTM D3462. 4.2.3 Duration', TruDefinition' Duration ; Duration' Premium Cool, TruDefinition` Duration' Designer Color Collection, TruDefinition° Oakridge ; Oakridge' and WeatherGual HP are fiberglass reinforced, laminated asphalt roof shingles. Meets ASTM D3462. 4.3 HIP & RIDGE SHINGLES: 4.3.1 Berkshire' Hip & Ridge Shingles with Sealant, DuraRli Hip & Ridge Shingles with Sealant, ProEl Hip & Ridge Shingles and WeatherGuard' HP Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. Meets ASTM D3462. NEMO ETC, LLC Evaluation Report 037940.01 Certificate of Authorization#32455 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R76 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 2 of 10 Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 6" Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. r •r Section Propert Standard Year 1507.2.4, R905.2.3 Physical Properties ASTM D1970 2015 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2011 Enti Examination Reference Date Owens Corning Declaration Equivalency Declaration 08/06/2019 PRI (TST5878) ASTM D1970 OCF-382-02-01 10/24/2017 UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs Various PRI (QUA9110) Quality Control Service Confirmation 04/05/2020 4.1 ACCESSORY STARTERS: 4.1.1 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter are starter strips for asphalt roof shingles. Meets ASTM D3462. 4.1.2 Starter Shingle Roll is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen starter strip, nominal 7.2 -inch wide x 33 -ft 4 -inch long roll, for use with asphalt shingles. Meets ASTM D1970. 4.2 ASPHALT SHINGLES: 4.2.1 Classic" and Supreme` are fiberglass reinforced, 3 -tab asphalt roof shingles. Meets ASTM D3462. 4.2.2 Berkshire' are fiberglass reinforced, 4 -tab asphalt roof shingles. Meets ASTM D3462. 4.2.3 Duration', TruDefinition' Duration ; Duration' Premium Cool, TruDefinition` Duration' Designer Color Collection, TruDefinition° Oakridge ; Oakridge' and WeatherGual HP are fiberglass reinforced, laminated asphalt roof shingles. Meets ASTM D3462. 4.3 HIP & RIDGE SHINGLES: 4.3.1 Berkshire' Hip & Ridge Shingles with Sealant, DuraRli Hip & Ridge Shingles with Sealant, ProEl Hip & Ridge Shingles and WeatherGuard' HP Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. Meets ASTM D3462. NEMO ETC, LLC Evaluation Report 037940.01 Certificate of Authorization#32455 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R76 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 2 of 10 ONEMOIetc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5_4 Wind Classification: 5.4.1 The Owens Corning asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating acceptable use in all wind zones up to Vaw =150 mph (VuIc =194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Note: Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.2 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter noted in Section 4.1.1 and the Owens Corning hip & ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating acceptable use in all wind zones up to Vam =150 mph (Vaft =194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners manufacturer's minimum requirements. FBC 1507.2 / R905.2 and the shingle 6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and published installation instructions. 6.2 ACCESSORY STARTERS: 6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens Corning current published instructions, using minimum five (5) nails per strip. Figure 1: Minimum Nailing, Starter Strip Figure 2: Minimum Nailing, Starter Strip Plus MEMO ETC, LLC Evaluation Report 037940.02.12-R10 Certificate of Authorization#32455 6'H EDITION (2017) FOC NON-HVHZ EVALUATION FL10674-RlS Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 3 of 10 ONEMOjetc. 6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions. Drip edge Dnp edge Starter Shingle Roll adhered directly to underlayment and primed drip edge Self-sealing adhesive positioned along eaves Figure 3: Starter'Shingle Roll 6.3 ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire' shingles require minimum five (5) nails per shingle. ➢ WeatherGuard' HP shingles require minimum six (6) nails per shingle. Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required Refer to Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Classic® & Supreme: Normal Mansard or Area para Wind Areas High Wind desvanes y Area para vientos normsras Areas vientos fumes 5"Exposure Exposfcidn Figure 4: Minimum Nailing, Classic & Supreme (Standard Size) Normal Mansard or Area para Wind Areas High Wind desvanea y Area pare vientos normales Areas Wants, tuertes t12 (A) tzt t• t° z° 5 518° Exposure Exposicidn Figure 5: Minimum Nailing, Classic & Supreme (Metric Size) NEMO ETC, LLC Evaluation Report 037940.02.12-1110 Certificate of Authorization#32455 6r" EDITION (2017) FBC NON•HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 4 of 10 6.3.1.2 Berkshire®: Figure 6: 5 -Nail Pattern, Berkshire ONEMO I etc. Sealant strip U tiro de sellador V / , e Figure 7: 6 -Nail Pattern, Berkshire Sealant sUip Ld Ilyd de sellddaY ,..1 r 2, Asphae 1o4n1.0 C¢ma+,t4 de tuLode astatto Figure 8: Mansard or Steep Slope Pattern, Berkshire NEMO ETC, LLC Evaluation Report 037940.02.12-R30 Certificate of Autho6zation #32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 5 of 10 ONEMOjetc. 6.3.1.3 Duration®, TruDefinitione Duration, Duration® Premium Cool & TruDefinition' Duration` Desiener Color Collection: 4 -Nail Fastening Pattern Su el,IWI ®fastening area width Nail, Typical 12" Figure 9: Standard 4 -Nail Pattern, Duration Figure 10: 6 -Nail Pattern, Duration Fastening for Slopes Greater Than 21:12 SureNaW fastening area width Nall Typical i" 12 12" 1" �.av cwnmvsuan' • f�.: .1. "ms nnwoaweno-.: I.;. eroxe uc� msu-e�"nw ♦, 6 -Ile" 5-516" .qio. ®�2" Four 1"Spots of Asphalt Roofing Cement Figure 11: Mansard or Steep Slope Pattern, Duration NEMO ETC, LLC Evaluation Report 037940.02.12-1130 Ceniifcate of Authorization#32455 6m EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-RIS Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 6 of 10 1( I �Z)')NEMOjetc. 6.3.1.4 TruDefinition°Oakridee®,Oakridee®: 4 Nail Pattern Esquama con 4 clavos 12" ^'0 1"l 121, 55/8"ExposureNxi�fs 65/8"Exposure Expesiaidtt de 65/8putg. Clavas Exposiaun de 6518pul9. Figure 12: Standard 4-N6il Pattern, Oakridge 6 NO Pattern Esquema con 6 ciavos 9" T mure Nails 5518" 55I8"Ex sure ExP Claves Expo 'um de 55/8pulg. Exposicien de 85/9pulg. Figure 13:6 -Nail Pattern, Oakridge 12' sumna n®m:�emna area .mm � nmi, rypme� C..W Figure 14: Mansard or Steep -Slope Pattern, Oakridge NEMO ETC, LLC Evaluation Report 037940.02.12-R30 Certificate ofAuMorizadon #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL10674R15 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 7 of 10 6.3.1.5 WeatherGuard® HP: 5 5!8' Exptasa W"65sde 5 so pub. 5 Sia'v firuenfrh! do 551 peRg. Figure 1S: 6 -Nail Pattern, WeatherGuard HP 8 Nal Pattern Esquema on 6 clavus Nail V8" from bottom of shingle 5 5t8" Ex. osura 6 Fasteners Clave a 6 Vii ppulg. de la p 6 sa etaderes parte inferior de la teja Ezpasicidn rite 6 618 ping. 1 Four 1" Spots of Asphalt Roof Cement Cuarro pontos de aemento de techo de asfalto de 1 pvl ada Figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HP 6.4 HIP & RIDGE SHINGLES: 6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions. ➢ Berkshire` Hip and Ridge Shingles with Sealant and Dura Ridge® Hip & Ridge Shingles with Sealant require minimum two (2) nails per shingle. ➢ WeatherGuard' HP Hip and Ridge Shingles and ProEdge® Hip & Ridge Shingles require minimum four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations. NEMO ETC, LLC Evaluation Report 037940.02.12 -RSO Certifrcate ofAuthonzoon #32455 6- EDITION (2017) FBC NON-HVH2 EVALUATION FL10674-RlS Owens Corning Asphalt Roof Shingles Revision 10: 08115(2019 Page 8 of 10 6.4.1.1 Berkshire® Hip & Ridge with Sealant and DuraRidge® Hip & Ridge Shingles with Sealant: Fig. A Prevailing Wind Direction t— Direccidn del viento predonninante Nails — Clavos a-8' E,Z"&'re—>.I Edposni6n de 8 ping P Figure 17: Isometric View, Berkshire and DuraRidge 6.4.1.2 WeatherGuard® HP Hip & Ridge Shingles: Fig. A q 4 Prevailing wind F—Dlrectbn p A Neils"_' -------}44 1 A p I I 44 I I I I 1 I I I A 1 1 I I I 1 I I Exposure Figure 19: Isometric View. WeatherGuard Fig. B Top View Vista superior Nail clava • owenscoming SureNall' I I I� �I« dG oc' I e vl IJ I �t 12"—-i� Figure 18: Plan View, Berkshire and DuraRidge Fig. C Hip & Ridge Shingle Fastening Top Vlaw Nails Nails 7" 2" 2'• p. 1• g, Exposure 1 12' Figure 20: Plan View, WeatherGuard HP Hip & Ridge NEMO ETC, LLC Evaluation Report 037940.02.12-R10 Certificate of Authorizotion#32455 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-RIS Owens Corning Asphalt Roof Shingles Revision 10: 06/15/2019 Page 9 of 10 6.4.1.3 ProEdge® Hip & Ridge Shingles: Prevailing Wind Direction Scalant Strip A''` E" Exposure Fasten T)" Cover Exposed Fasteners with Roof Cement Figure 21: Isometric View, ProEdge ONEMOjetc. Standard 7P, Fastening Pattern 12" Sealant 711,7'1" 6„Ezposure 1 h-72" 1 Figure 22: Plan View, ProEdge 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA requirements. PRI Construction Materials Technologies, LLC— QUA9110; 813 621-5777; bwilson@pricmt.com - END OF EVALUATION REPORT - MEMO ETC, LLC Evaluation Report 037940.02.12.1110 Certificate of Authorization#32455 6n' EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 10 of 10