HomeMy WebLinkAboutEMS Accordion FBC SelectedProfessional
Regulation e#r.o
ago"
BCIS Home Log In user Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact lis BCIS Site Map Links Search
bProduct
r Approval
p
USER: Public User
Product Approval Menu > Product or r Appl icatien Search > Appllcai List > Application Detail
FL #
FL1850-R11
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer American Shutter Systems Association, Inc,
Address/Phone/Email 4268 Westroads Drive
West Palm Beach, FL 33407
(561) 209-8263
bfeeley@easternmetal.com
Authorized Signature Bill Feeley
]rodriguez@easternmetal.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Shutters
Subcategory Accordion
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Walter A. Tillit, Jr., P.E.
Evaluation Report
Florida License PE -44167
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2020
Validated By John Henry Kampmann Jr.
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL1.850 R11 COI AMERICAN SHUTTER SYSTEMS, INC. DRAWING 17-
102 CERTIFICATE OF INDEPENDENCE, PDF
Standard
Year
ASTM E1886
2005
ASTM E1996
2005
ASTM E330
2002
TAS 201, 202, 203
1994
Product Approval Method Method 1 Option D
Date Submitted
10/03/2017
Date Validated
10/13/2017
Date Pending FBC Approval
10/17/2017
Date Approved
12/12/2017
5ummarf of Products
FL V Model, Number or Name
Description
1850,1 Bertha HV Accordion -Blade 3 (HVHZ)
Drawing# 17-103
Extruded aluminum blades folded together thru knuckles and
retained by tracks to provide hurricane protection.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Installation Instructions
FL1850 R11 II AMERICAN SHUTTER SYSTEMS ASSOC ,INC
DRAWING 17-103 BERTHA HV ACCORDION SHUTTER
SYST.,PDF }�
Design Pressure: N/A
Other: Large Missile Level "D", Max span is 12'-7" for 35 psf
positive ASD load and 13'-0" for 35 psf negative ASD load for
Verified By: American Test Lab of South Florida, Inc.
Created by Independent Third Party: Yes
Evaluation Reports
one specific condition shown in span tables. See additional
loads and spans on engineered drawings.
FL1850 R11 AE AMERICAN SHUTTER SYSTEMS ASSOC.,.
INC. DRAWING 17-103 PRODUCT EVALUATION REPORT,PDF
Created by Independent Third Party: Yes
1850.2Bertha HV Accordion Shutter
?Combo) - HVHZ - Drawing#17-102
Extruded aluminum interlocking blades retained by tracks (top
and bottom) for storm protection
Limits of Use
Installlation Instructions
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
FL1850 Rif 1I AMERLrAN SHUTTER SYSTEMS, INC.
DRAWIN 17-102 BERTHA HV ACCORDION SHUTTER,
SYSTEM.PDF
Design Pressure: N/A
Other: Large Missile Level "D". Max. span is 13'-2" for 30 psf
positive ASD load w/o window blade, 16-0" for 30 psf negative
ASD load for HVI. blade w/o window blade for conditions
indicated on schedule #1, sheet 12. And 12'-3" for 30 psf
positive ASD load w/o window blade and 1S`-5 for 30 psf
negative ASD load for HV2 blade w/o window blade, See sheets
number 12, 25, 28 and 28A of installation drawings for other
Verified By: American Test Lab of South Florida, Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FLIB50._all AE AMERICAN SHUTTER_USTEMS, INC,
DRAWING 17-102 PRODUCT EVALUATION REPORT.PDF
Created by Independent Third Party: Yes
spans and pressures,
1850.3
Bertha HV Accordion Shutter - Blade
1 Only (HVHZ) - Drwg# 17-122
Extruded aluminum interlocking blades retained by tracks (top
and bottom) for storm protection
Limits of Use
Approved for use In HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large missile level "D". Max, span is 16'-0" and 14'-9"
for 30 psf ASD negative load depending on centermates and
locking rod configuration for the HV1 blade, 8'-0" for +64, -72
psf load for HV blade for Keystone mountings T-0" for +75, -75
psf for metals stud mountings and 8'-0" for 110 psf. for HV1
Installation Instructions
FL1850 R11 II AMERICAN SHUTTER SYSTEMS ASSOC. INC
DRAWING 17-122 BERTHA HV ACCORDION SYST PDF
Verified By: American Test Lab of South Florida, Inc,
Created by Independent Third Party: Yes
Evaluation Reports
FLi85,,-(j R11 AE AMERICAN SHUTTER $Y5TEMS ASSOC INC
DRAWING 17-122 PRODUCT EVALUATION REPORT PDF
Created by Independent Third Party: Yes
and HV1A working in unison. See sheets 7, 11, 20 and 19
respectively of installation drawings for other spans and
pressures.
Contact Us :: 2501 Blair. Stone Road, Tallahassee F 3�.. 2399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Zayydght 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional waif, If you have any questions, please contact 850,487,1395, -Pursuant m Section 455,275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F,B, must provide the Department with an email address ff they have one, The emails
provided may be used for official commun}cation with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the. public, To determine If you are a licensee under Chapter 455, F.S., please click here
Product Approval Accepts:
MW W2 FOX Ed
Credit Card
Safe