Loading...
HomeMy WebLinkAboutEnergy CodeBraden & Braden, AIA, PA AL & Y" #AA0000032 417 Coconut Ave. Stuart, FL 34996 •(772) 287-8258 St. Lucie Countg Building Dept. Wynne. Development Date: --A Address: CA Permit (a3� To whom it mag concern, This detail applies to the insulation in the ends of the vaulted ceilings. If you have ang questions please feel free to call me at 112-281-8258 R-19 Since ly D 1 1 Braden AIA Braden t Braden AIA PA 10 C)ji, D�C� H 0C'a® M ®r ZZ(� 4Z® M C 0 m Trusses at 24" o.c. ae shop drawings by others ceiling transition k- ded using metal studs erd'y exact configuration :es 0 R-30 Batts -19 batts Drywall ceding see typical section Gelling transition Insulation Detail nts FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE � Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL. \ vs Permit Number: Owner: WYNNE BUILDING CORP. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1718.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Inl Insul, Exterior R=4.1 1155.40 ft2 b. Concrete Block- Int Insul, Adjacent R=11.0 282.92 ft- 2. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=11.0 240.00 ft2 4. Number of Bedrooms 1 d. other (see details) R= 40.00 112 5. Is this a worst case? Yes 10. Ceiling Types (1336.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1306.00 ft2 8. Conditioned floor area above grade (ft� 1306 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (ft� 0 c. N/A R= ft2 11. Ducts R ft2 7. V indows(128:9 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 120 a. U-Factor: Sgl, U=1.02 76.04 112 SHGC: SHGC=0.29 ' b. U-Factor. Sgl, U=1.03 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 29.0 SEER:14.00 c. U-Factor: Sgl, U=1.02 12.85 ft2 SHGC: SHGC=0.26 13. Heating systems kBtulhr Efficiency d. U-Factor. WA ft2 a. Electric Heat Pump 27.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 4.701 ft. Area Weighted Average SHGC: 0.281 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1306.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1306.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.099 Total Proposed Modified Loads: 43.39 PASS Total Baseline Loads: 44.12 1 hereby certify that the plans and specifications covered by Review of the plans and 52, this calculation are in compliance with the Florida Energy specifications covered by this 04 _ ; O Code. calculation indicates compliance /�_ with the Florida Energy Code. /� PREPARED BY: A %00 Before construction is completed DATE: 1-9-20 this building will be inspectedfork�'- compliance with Section 553.908 R. I hereby certify that this building, as designed, is in compliance Florida Statutes. !__ with the Florida Energy Code._ - CODyy¢'Y¢ �� OWNER/Aft>1�gCl� BUILDING OFFICIAL: DATE: \ DATE: N o Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordanc V4r&W.FQI ISQ nQect requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (I7i jbt COMPLIANCE (ST..,JL�UCIE COUNTY BOCC 1/8/2020 5:04 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 'FORM R405-2017 , INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE BUIDLING-THE CO Bedrooms: 1 Address Type: Street Address Building Type: User Conditioned Area: 1306 Lot# Owner Name: WYNNE BUILDING CORP. Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING CORP. Rotate Angle: 180 Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, Stale, Zip: FT. PIERCE, Family Type: Single-family FL, New/E)dsting: New (From Plans) Comment: CLIMATE _ / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.6 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1306 10676.2 SPACES Number Name Area Volume IGtchen Occupants Bedrooms InfiilID Finished Cooled Heated 1 MASTER BEDR00 234 1895.4 No 0 1 1 Yes Yes Yes 2 DEN 144 1166.4 No 0 1 Yes Yes Yes 3 SINKAREA 42 340.2 No 0 1 Yes Yes Yes 4 CLOSET 63 510.3 No 0 1 No Yes Yes 5 GREAT ROOM 452 3661.2 No 2 1 Yes Yes Yes 6 MASTER BATH 50 405 No 0 1 Yes Yes Yes 7 POWDER 25 202.5 No 0 1 No Yes Yes 8 KITCHEN 232 1879.2 Yes 0 1 Yes Yes Yes 9 LAUNDRY 40 324 No 0 1 No Yes Yes 10 STORAGE 24 192 No 0 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 31 it .0 234 ft' _ 0 1 0 2 Slab -On -Grade Edge Insulatio DEN 24 ft 0 144 ft' — 0 1 0 35lab-On-Grade Edge Insulatio SINK AREA 7 ft 0 42 ft' _ 0 1 0 -� 4SIab-On-Grade Edge Insulatio CLOSET 1 ft 0 63 ft' _— 0 1 0 5 Slab -On -Grade Edge Insulatio GREAT ROOM 32 It 0 452 ft' _ 0 1 0 6 Slab -On -Grade Edge Insulatio MASTER BATH 5 ft 0 5o ft' _ 0 1 0 7 Slab -On -Grade Edge Insulatio POWDER 1 ft 0 25 fl' _ 0 1 0 1/8l2020 5:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017. INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio KITCHEN 38 ft - 0 232 ft2 0 1 0 9SIab-On-Grade Edge Insulatio LAUNDRY 1 ft 0 40 ft' - 0 1 0 10Slab-On-Grade Edge Insulatio STORAGE 21 ft 0 24 ft2 _ 0 0 1 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area - Area Color Barr Absoc Tested Tested Insul. (deg) 1 Hip Metal 1376 ft' 0 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1306 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 234112 0.1 Wood _ 2 Under Attic (Vented) DEN 30 Blown 144 ft' 0.1 Wood 3 Under Attic (Vented) SINK AREA 30 Blown 42ft2 0.1 Wood 4 Under Attic (Vented) CLOSET 30 Blown 63ft' 0.1 Wood 5 Under Attic (Vented) GREAT ROOM 30 Blown 452 ft' 0.1 Wood 6 Under Attic (Vented) MASTER BATH 30 Blown 50 ft' 0.1 Wood _ 7 Under Attic (Vented) - POWDER 30 Blown 25111' 0.1 Wood- _ 6 Under Attic (Vented) KITCHEN 30 Blown 232 ft2 0.1 Wood 9 Under Attic (Vented) LAUNDRY 30 Blown 40112 0.1 Wood 10 Under Attic (Vented) STORAGE 30 Blown 24 ft2 0.11 Wood 11 Knee Wall (Vented) GREAT ROOM 19 Blown 30 112 0.11 Wood WALLS Adjacent Cavity Width Space Height Sheathing Framing Solar Below _ 1 S=>N Exterior 'Concrete Block - Int InsNASTER BE 4.1 18 0 8 1 145.5 ft' 0 0 0.3 0 _ 2 W=>E Exterior Concrete Block - Int Ins00ASTER BE 4.1 13 0 8 1 105.1 ft' 0 0 0.3 0 3 N=>S Exterior ConcreteBlock-Int Insul DEN 4.1 12 0 8 1 97.0 ft2 0 0 0.3 0 _ 4 W=.>E Exterior Concrete Block- Int Insul DEN 4.1 12 0 8 1 97.0 ft' 0 0 0.3 0 _ 5 S=>N Exterior Concrete block- Int InsLSINK AREA 4.1 7 0 8 1 56.6 ft' 0 0 0.3 0 _ 6 N=>S Exterior Concrete Block- Int InsGREAT ROO 4.1 22 0 8 1 177.8 ft2 0 0 0.3 0 7 W=>E Exterior Concrete Block- Int Ins01REAT ROO 4.1 10, 0 8 ' 1 80.8 ft2 0 0 0.3 0 _ 8 S=>N Exterior Concrete Block- Int InsNASTER BA 4.1 5 0 8 1 40.4 1`12 0 0 0.3 0 _ 9 N=>S Exterior Concrete Block - Int Insu1KITCHEN 4.1 17 0 8 1 137A 112 0 0 0.3 0 ' 10 E=>W Exterior Concrete Block- Int lnsulKITCHEN 4:1 16 0 8 1 129.3 ft2 0 0 0.3 0 11 S=>N Exterior Concrete Block- Int InsulKITCHEN 4.1 5 0 8 1 40.4 f12 0 0 0.3 0 1/8/2020 5:04'PM EnergyGaugeS USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARYCHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 12 N=>S Garage Concrete Block- Int InsulKITCHEN 11 35 8 13 N=>S Exterior Concrete Block- Int InsuSTORAGE 4.0999 6 8 _ 14 N=>S Garage Concrete Block- Int InsuBTORAGE 4.0999 5 8 15 N=>S Garage Frame - Wood MASTER BE 11 30 8 1 282.9 ft' 48.0 ft2 40.0 ft' 0 240.0 ft2 0 0 0.3 0 0 0.3 0 0 0.3 0 0.23 0.3 0 0 0 0 DOORS # Omt Door Type Space Stones U-Value Width Height Ft In Ft In Area 1 E=>W Insulated KITCHEN None .32 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => chantled to Worst Case. - / Wall V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening _ 1 W=>E 2 Metal 2 W=>E 4 Metal 3 N=>S 6 Metal 4 W=>E 7 Metal _ 5 S=>N 8 Metal 6 E=>W 10 Metal Low-E Single Yes 1.02 0.29 N Low-E Single Yes 1.02 0.29 N Low-E Single Yes 1.02 0.29 N Low-E Single Yes 1.03 0.27 N Low•E Single Yes 1.02 0.29 N Low-E Single Yes 1.02 0.26 N 32.4 ft2 . 1 It 5 in 18.4 ft2 1 It 51n 18.4 ft' 1 ft 5 in 40.0 ft2 12 it 0 in 6.9 ft' 1 it 5 In 12.8 112 1 ft 5 in 1 ft 5ln None 1 it 5 in None 1 ft 5 in None 1 ft -yin None 1 ft 5ln None 1 it 5 in None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 280 ft2 280 ft2 35 ft 8.1 It 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000257 881.4 48.38 90.99 .0896 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.2 27 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 14 29 kBtu/hr cfm. 0.8 1 sys#1 1/8/2020 5:04 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 'FORM R405-2017 INPUT SUMMARY'CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Carl# Company Name System Model# Collector Model# Area Volume FEF None None ft' DUCTS — Supply — — Return -- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 120 ft' Attic 45 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES ProgramablCoolingrje ThermostaJant: Ceiling Fans: 1jN j[Febr[X��j Jan Venting Feb ki rjr layIjX �jX IjX (jXj� jj jj Ort jjXjj NOV j�Xjj Dec [ ] [ ] Mar [Xj Apr [ ] May [ Jun [ Jul [ Aug [ ] Sep [X] Oct [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78. 78 Heating (WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.fL 0 fF 0 ft 0.3 MASTER BEDROO Defaull(B Ibs/sq.fL ft' ft 0.3 DEN Default(8 lbs/sq.ft. ft' ft 0.3 SINKAREA Default(81bs/sq.8. ft' ft 0.3 CLOSET Default(8 Ibs/sq.ft. ft' ft 0.3 GREAT ROOM Default(8 Ibs/sq.fL ft' ft 0.3 MASTER BATH Default(8 lbs/sq.fL ft' _ ft 0.3 POWDER Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft' ft 0.3 LAUNDRY Default(8 Ibs/s .ft. 0 ft' Oft 0.3 STORAGE 1/8/2020 5:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE. COTTAGE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. U Owner: WYNNE BUILDING CORP. Jurisdiction: w Design Location: FL, Fort Pierce c=.i COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable Insulation shall requirements The exterior thermal envelope contains a continuous air barter. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceilinglal is The air barrier in anydropped ceiling/soffit shall be aligned with The Insulation in any dropped ceiling/soffit the Insulation and any gaps in the air barder,shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee wells shall be sealed. per inch minimum. Exterior themlal envelope Insulation for framed walls shall be Installed In substantial contact and continuous alignment with the air barter. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall Include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity Insulation shall be Installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side -floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity, spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac Bs. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures Installed In the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and Wdng Bari Insulation shall be cut neatly to fit around Wring and plumbing in exterior walls, or Insulation that on installation readily conforms to available space shall extend behind pining an wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electricallphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be Installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklersshall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire snrinkler cover niates and walls or ceilinas a. In addition,inspection of log walls shall be in accordance with the provisions of ICC400. 1/8/2020 5:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level ' a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 1 13. Cooling system: Capacity 29.0 a) Split system SEER 14.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c)Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1306 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.028 b) Solar Heat Gain Coefficient'(SHGC) 7b. 0.281 c) Area 7c. 128.9 8. Skylights a) U-factor.(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b), Single assembly c) Knee walls/skylight walls d) Radiant barrier installed. 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 14. Heating system: Capacity 27.0 a) Split system heat pump HSPF 8.2 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas. AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.95 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ 0 Heat recovery unit HeatRec% g) Other 10B1. 11.0 1082. varies 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. 19.0 d) Multizone cooling credit 11d. No e) Multizone heating credit 9 Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Dater Address of New Home: THE COTTAGE �`� City/FL Zip: FT. PIERCE, FL 3 \A -t 1/8/2020 5:04:49 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1