Loading...
HomeMy WebLinkAbout001 Wilson Metal Building - Signed and Sealed Plan - 372 Cyclone DrPlanning & Development Services Department s Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553 Certification for Design Load Compliance Project Name: WILSON Project Address: 372 CYCLONE DR. FORT PIERCE, FL Permit ti: Occupancy Type: S Construction Type: V INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the It above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code 2017 Edition with 20 _Supplements using ASCE 7-20 2. Structure Designed as (check one): X Enclosed Partially Enclosed _Open 3. Risk Category: _I XII_III _IVExposure Category: _B X C_D 4. Design Wind Velocity 160 mph 124 ASD N/A LRFD End Zone Width: 5 ft S. Mean Roof Height: 17 ft Roof Pitch: t :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on allplan openings): 16.0 16.0 16.0 33.6 33.6 31.4 Zone 1: - 16.0 Zone 2: .56.3 Zone 3: -84.7 Zone 4: _36.4 Zone S: _44.9 Garage: _34.2 7. Design Loads: Floor: 100 PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony:. N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF / CONCENTRATED S. Were Shear Walls Considered For Structure?. X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure:. 2000 PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Paul Welch P.E. 29945 / 5115 Print Name Cert If & Co. Cert Auth. Paul Welch Inc. ON PLAN 5/15/2020 Signature, Date, and Seal 1984 S.W.'Biltmore St. Suite #114 Port St. Lucie, FL SLCCOV Form # 020-12 Revised 3/15/12 OCompany Name & Address 5) i PROJECT DATA: NAME: WILSON ADDRESS: 372 CYCLONE DR. FORT PIERCE, FL SQUARE FOOTAGE: 1575 SQ. FT. OCCUPANCY CLASSIFICATION: GROUPS OCCUPANCY LOAD: PER FBC TABLE 1004.1.2 1575 / 500 = 4 PEOPLE TYPE OF CONSTRUCTION: V NOTES: 1) THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT. 2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. 3) ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 4) ALL CONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING CODE (FBC) 2017. STRUCTURAL NOTES 1) DESIGN LOADS IN ACCORDANCE WITH ASCE7-10. 2) SOIL BEARING CAPACITY: 2000 PSF (MIN.). 3) SLAB / FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE STRENGTH AT 28 DAYS. SEE PLAN FOR SIZES & STEEL REQUIREMENTS. 4) MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTINGS: 3" BEAMS: I %" SUSPENDED SLABS: 1'/2" 5) LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS EXCEPT AS NOTED GRADE 60 STEEL MINIMUM IN BEAMS AND COLUMNS. 6) SPLITING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALATION OF HARDWARE IS NOT PERMITED. 7) UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD PRACTICIES. 8) ALL METAL BUILDING FRAMING, SIDING, ROOF, ECT... DESIGNED BY IRONBUILT STEEL BUILDINGS, DAVID M. TAMBORSKI P.E. LIC04502 DATED 4/22/2020. `. WINDOW / DOOR SCHEDULE MARK DESCRIPTION APPLIED DESIGN PRESSURE 1 144" W X 168" I -I ROLL UP DOOR +31.4 / -34.2 PSF 2 36" W X 80" 1-1 SOLID CORE DOOR +33.4 / -36.2 PSF 3 144" W X 168" H ROLL UP DOOR +31.4 / -34.2 PSF 4 144" W X 168" H ROLL UP DOOR +31.4 / -34.2 PSF FOUNDATION SCHEDULE MARK DESCRIPTION F-1 36" X 36" X 24" DEEP (2500 PSI) CONCRETE PAD FOOTING W/ #5 BARS AT 8" O.C. BOTH WAYS F-2 54" X 54" X 24" DEEP (2500 PSI) CONCRETE PAD FOOTING W/ #5 BARS AT 8" O.C. BOTH WAYS F-3 100" X 100" X 24" DEEP (2500 PSI) CONCRETE PAD FOOTING W/ #5 BARS AT 8" O.C. BOTH WAYS F-4 16" D X 16" W (2500 PSI) CONCRETE MONOLITHIC FOOTING W/ (2) #5 BARS CONTINUOUS S-1 4" THK (2500 PSI) CONCRETE SLAB W/ FIBERMESH OR 6"/ 6" 10/10 W WM OVER VAPOR BARRIER ON CLEAN COMPACTED CHEMICALLY TREATED FILL u'�rt" i vel 0 �• N Planning & Development Services Department Building & Regulations Division -- Product Review Affidavit Building Permit # Owners Name XI1 Applicant: Product Opening Design Pressures Product Rated Design Pressure Manufacturer Model Number Product Approval Number 0 Method of Attachment . Windows Mullions Fixed Glass Block Glass I . Skylights ` 0 �• N Planning & Development Services Department Building & Regulations Division -- Product Review Affidavit Building Permit # Owners Name XI1 Applicant: Product Opening Design Pressures Product Rated Design Pressure Manufacturer Model Number Product Approval Number Glass Type Method of Attachment . Windows Mullions Fixed Glass Block Glass I . Skylights ` Sliding Glass Doors SwingTypeDoors +si '<{--3(a, f- o C'.LCep TLPlo- �l. l(r+3�'�,2 r..t�� 2).•�i o`�s A -T. French Doors N � Gara eDoors TI0(�, F'�i` 1/ 4z4 ;tl a A t� 4 J< 1" t�Ft�a AT S,444%,C, Hurricane Protection Roof Ventilation Roofing Material FQ� µKI" Y�ki't.- .AN.t:QICA� �yrAN� I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. Name: A.Au.t iEtLL\ Signature: seal Design Prof: Y ;4Ut. A S.- Lr- LA T-"; Cert. No. z.Cn- 4ys Date: 4P64 t,.1"` 22' cn" i.I- Z.2) fit, F--� f -Z v� K' I 1 Q„ I �i P I^-) .. .... ... . PAUL WELCH INC. _ -MECHANICAL * ELECTRICAL * CIVIL ENGINEERING 1984 S.W. BILTMORE ST. SUITE#1 14 PORT SAINT LUC IE, FL 34984 PHONE EMAIL (772) 785.9888 PWELCHINC@AOL.COM MAY 1 8 7020 PAUI-.1A!FI.P:I4 P.E. Ff..., ?o9/r5 E 0 U