Loading...
HomeMy WebLinkAboutTrussBBraden & Braden, AIA, PA AZ&F& 9"#AAC000032 417 Coconut Ave. Stuart, FL. 34996 • (772) 287-8258 St. Lucie County Building Dept. Wynne Development Date: Address: Permit #: % i�� — � To whom it mag concern, This detail applies to the insulation in the ends of the vaulted ceilings. If you have any questions please feel free to call me at 112-281-8258 R-19 Sincer I D R. Braden AIA Braden i Braden AIA PA Trusses at 2q" o.c. re shop drawings bg others ceiling transition =� ded using metal studs erifg exact conFiguration :es vLL E� i• ) U G. cam Ui W V f R-30 Batts batts Drywall ceding see typical section eiling transition Insulation Detail nts \� C� RE: M11455 MiTek USA, Inc. THE COTTAGE 6904 Parke East Blvd. Tampa, FL 33610-4115 Site Information: Customer: WYNNE DEVELOPMENT Project Name: M11455 Lot/Block: Model: Address: UNKNOWN City: ST LUCIE COUNTY Subdivision: State: FL General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.3 Wind Code: ASCE 7-10 Wind Speed: 165 mph Roof Load: 37.0 psf Floor Load: N/A psf , This package includes 18 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date I T18621009 a 11/11/2019 2 T18622010 al 11/11/2019 3 T18622011 a2 11/11/2019 4 T18622012 a3 11/11/2019 5 T18622013 ata 11/11/2019 6 T18622014 sib 11/11/2019 7 T18622015 b 11/11/2019 8 T18622016 bl 11/11/2019 9 T18622017 b2 11/11/2019 10 T18622018 b3 11/11/2019 11 T18622019 gra 11/11/2019 12 T18622020 grb 11/11/2019 13 T18622021 j1 11/11/2019 14 T18622022 j3 11/11/2019 15 T18622023 j5 11/11/2019 16 T1862202 j7 11/11/2019 17 T18622025 j7p 11/11/2019 18 T18622026 kj7 11/11/2019 The truss drawing(s) referenced above have been prepared by MiTek USA, Inc under my direct supervision based on the parameters provided by Chambers Truss. Truss Design Engineer's Name: Albani, Thomas My license renewal date for the state of Florida is February 28, 2021. Florida COA: 6634 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any:particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/rPI 1, Chapter 2. - rF-. OF :W�.. J� <ORtOP��`. /O N A���,%' '1111111r10, Thomas A Albans PE N0.39380 M1fek Usk Inc. FL Cert 6634 6904 Padre East Bid. Tampa FL 33610 November 11, 2019 1 of 1 Albani, Thomas Job Thus Truss Type qry Ply r T78622009 Mi1455 A Roof Special 7 1 �THECOTTAGE Job Reference a tional Chambers Truss, Inc., Fort Pierce, FL 8.320 a Uct 29 2019 MI Iex Industnes, Inc. Mon NOV 11 0/29:142U1 iI scale = 1:60.3 4.00 12 54 = RR 14 13 6x8 = 3x5 = 3x4 = 5.8 W18HS = 3x12 = 2.00 12 9-11-1 15{+0 1 17_ 1 24-11-0 i 35-0-0 9-11-1 5-6-15 2-0-0 7-SA 10-1-0 oI9 - Plate Offsets (XY)- [2.0-1-2 Edge1 [4:0-0-00-3-01 [7:0-4-12 03-0], [9:0-1-15 Edael [13:0-1-12 0-2-81 LOADING (psi) SPACING- 2-0-0 GSI. DEFL in floc) Wall Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.75 Ven(LL) -0.59 11 >711 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.95 Vert(CT) -1.08 11 >388 240 MT16HS 244/190 BCLL 0.0 ' Rep Stress Incr YES WB 0.98 HOrz(CT) 0.38 9 nta n/a BCOL 10.0 Code FBC2017/TPI2014 Matrix -MS Wind(LL) 0.80 11 >522 240 Weight: 161 lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-2-1 oc puffins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 WEBS 2 Rows at 113 pis 7-12 REACTIONS. (Ib/size) 2=1349/0-8-0, 9=1349/0-8-0 Max Hoa 2=179(LC 11) Max Uplift 2=-625(LC 12), 9=-825(LC 12) FORCES. fib).- Max. Comp -/Max. Ten. -All tomes 250 (lb) or less except when shown. TOP CHORD 2-3=-3241/2130, 3-4=-3030/2042, 4-5=-2295/1599, 5-6= 2218/1620, 6-7= 2308/1622, 7-8=-5432/3544, 6-9=-5684/3648 BOT CHORD 2-14— 1885/3038,.13-14=-1708/2834, 12-13=-1240/2181, 11-12=3315/5376, 9-11=.3386/5407 WEBS 4-14= 261/511, 4-13=-885/601, 7-11=-111411991, 3-14=-345/323, 6-12=-604/1026, 7-12=-3412/2219 NOTES- 1) Unbalanced roof live loadshave been considered for this. design. 2) Wind: ASCE 7.10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=4511; L=351t; eave=58; Cat. II; Fxp C; Encl.. GCpi=0.18; MW FRS (directional) and C-C Extedor(2) -1-0-0 to 2-6-0, Interior(l) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to 21-0-0. Interior(1) 21-M to 36-0-0 zone;C-C for members and farces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of,20.Opsf, on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=825, 9=825. Thomas A. Alban! PE No.39380 h Tek USA, Inc. FL Cert 0834 6904 Parke East Blvd. Tampa FL 33610 Date: November 11,2019 Q WARNING- VezfrydeslgnpVwnetersend READ NOTES ON. THIS AND 1NCLODED4ffTEKREFERANCEPAGEMW4Mn,.. 1aWe201S BEFORE USE Design validfor use onlywiltrMTekOconnectors. This design is based only upon parameters shcwn.and Is for an Inc Mduol building component not �r- ■` . a truss system. Before use, me laureling designer must verify the applicabiny of design parameters and properly Incorporate this design Into hie overall burdingdesign. BracinglnoscatedIstoprevent bucklingofIndividual truss web and/or chord members only. .AdOBlpnaltemporary and pemonentbrocing M!Tek' Is ahvays required for s1clally and to prevent collapse with possible personal Injury and properly damage. For general guidance regarding the fobr ootlon. storage, delivery, erection and brocing of trusses and truss systems seeANS9rP11 Cua@v Cr6M o, DSM9 and BC51 Building Component 69M Parke East Blvd. Safety Mfermatlonovolloble from True plate Institute. 218 N. lee Sheet Suite 312. Alexandria VA 22 14. Tampe, FL 3361 O Job Truss Truss Type Oty Ply ` T18622010 Mii455 Al Hip 2 1 �THECOTTAGE Job Reference (optional) Chambers Tess, Inc., Fort Pierce, FL cI d 8.320 s Oct 29 2019 MiTek Industries, Inc. Mon Nov 11 07:29:15 2019 Page 1 ID:AXCVr6ubfdeoJ57JCdyWPDyLFMw-Xv A%_vyoRlogZdoiBRWvIOOH7VveZAk75KYbyKK71 e-11.1 1-0a e-1a 6-114 15 naa a z3b1 za11-0 zsao zeal asaa peo4 1^aa &1.3 0 -11 i 6a15 { 1ac 5-b1 %a1s M 1 za2 I W14 1ao 93 Scale=1:62.3 4.00 12 airs II 5 Sx8 MT18HS = 14 13 UB = 3x5 = 3x4 = 5 8 = 3x12 2.00 12 &1-14 i 9-11-1 15£-0 VV ffl 24-11E11-0 0- l-0 25012 35-00 taA taq 12 9-11< d Plate Offsets 04Y)— f2:0-1-2Edael I4:0-3-00-3-01 (7:0.3-0Edgel f9.0-1-15Edoe1 f13:0-2-402-01 LOADING (psf) SPACING- 2-0-0 CSI. DEFL in (too) Udefl Ud PLATES GRIP TCLL 20.0 Plate Grip POL 1.26 TC 0.75 Ven(LL) -0.60 11 >701 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.94 Vent(CT) -1.10 11 >382 240 MT18HS 244/190 BCLL 0.0 ' Rep Stress Incr YES WB 0.99 Horz(CT) 0.39 9 n1a n/a BCDL 10.0 Code FBC2017fTPI2014 Matrix -MS Wind(LL) 0.82 11 >515 240 Weight: 160 It, FT=20% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING - TOP CHORD Stmctuml wood sheathing directly applied or 2-2-1 pc purlins. BOTCHORD Rigid ceiling directly applied or 2-2-0oc bracing. WEBS 2 Rows at 1/3 pts 7-12 REACTIONS. (lb/size) 2=1349/0-8-0, 9=1349/0-8-0 Max Horz 2=-177(LC 10) Max Uplift 2— 825(LC 12), 9=-825(LC 12) FORCES. (lb) - Max CompJMax Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3240/2183, 3-4=-3025/2104, 4-5= 2311/1658, 5-6=-222511676, 6-7=-2322/1684, 7-8=5442/3689,8-9=-5685/3760 BOT CHORD 2-14=-1952/3038, 13-14=-1786/2833, 12-13=-1298/2195, 11-12=-3502/5450, 9-11=-3493/5408 WEBS 4-14= 261/512, 4-13=-867/611, 7-12=-3462/2358, 3-14=-359/334, 6-12=593/978, 7-11=-1144/2008 NOTES- 1) Unbalanced mof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=T.2psf; BCOL=3.Opsf; h=15ff, B=45fF L=35D; eave=5D; Cat. II; Exp C; Encl., GCpi=0.18; MNFRS (directional) and C-C Extehor(2) -1-" to 2-8-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to 22-5-6. Interior(1) 22-5-6 to 36-0-0 zone;C-C for members and fames & MWFRS for reactions shaven; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) - This truss has been designed for a live load of 20.Opsf.on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of beating surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) except at=1b) 2=825, 9=825. Thomas A Albani PE No.39380 MiTek USA, Inc. FL Cent 6634 6904 Parke East Blvd. Tampa FL 33610 Date: November 11,2019 O WARNNG -Veriy design parameters antl BEAD NOTES ON THIS AND NCLUDED aerEK REFERANCE PAGE W74M rev. floe 15 BEFORE USE Design vdld for use only wm1 M1fekG oonnectors. This design is based oNy upon parmmeters shown. and Isfor on Individual Wrong component, not �� a truss system. Before use. the DWtling designer must vent' the opplicablWy of design Wameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual buss web and/or chard members wly. Additional temporary and permanent brocing isalwaysrequ'redfo,sta ily and prevent collapse with possible personal and property carnage. For general guidance regcrdhgthe MiTek- fobricofidn, sbrage, delNery. erecHw and brocing of frussets and Visa systems, saeAN5VIP11 Quality Clepda, DSB419 and BC516u9dbD Component 6904 Parke East Blvd. SoleN Infommtbnwo0oble from Truss Rate InsillNe, 218 N. Lee Street Suite 312, Alexandria. VA 22314. Tampa, FL 336101 Job Truss Truss Type (hy Ply THE COTTAGE T18622011 M11455 A2 Hip 1 1 Job Reference (olAbonaft cnamoers i rues, me., con coerce, ri- ...,., ,,,._,,,_ ... ID:AXCVr6ubfdeoJSaCdyWPDyLFMw-UH7gbBOAUChT18i?w7DvcKNnA5m2NgPTCRaRcUyKK7G 't-0. 7-7-2 11-0-0 17-8-0 24-0-0 27-<-14 35.0.0 6.0- -D 7-7-2 3-414 fi-6-0 66.0 3-4-14 7-7-2 1-0- Scale =1:60.5 4x8 = 2YJ II 4x8 = 4.00 12 4 25 26 5 27 28 6' 16 15 14 13 12 11 10 3x6 = 2x3 II 4x6 = 3x8 = 3.4 = 2x3 II US = 3x4'= 4x6 = LOADING (psl TCLL 20.0 TCDL 7.0 BCLL 0.0 ' BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017/rPI2014 CS'. TC 0.47 BC 0.62 WB 0.46 Matdx-MS DEFL. in (too) Well Ud Verl -0.26 13 >999 360 Vert(CT) -0.4912-13 >857 240 Horz(CT) 0.13 8 rda rda Wind(LL) 0.37 13 >999 240 PLATES GRIP MT20 244/190 Weight: 164 lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directlyapplied or 3-5-15 oc puffins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or4-B-8 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (Wsize) 2=134910-8-0, 8=1349/0-8-0 Max Horz 2=-117(LC 10) Max Uplift 2=-825(LC 12), 8=-825(LC 12) FORCES. (lb) - Max. ComplMax. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3306/2465, 3-0=-2825/2179, 4-5=-3132/2434, 5-6=-3132/2434, 6-7=-2825/2179, 7-8=-3306/2465' BOT CHORD 2-16=-2226/3099, 14-16=-2226/3099, 13-14=-1826/2656, 12-13=-1834/2656, 10-12=-2234/3099,8-10=-2234/3099 WEBS 3-14=-569/506,4-14=-263/411;4-13=A51/683, 5-13=4105/454, 6-13=-451/683, 6-12=263/411, 7-12= 569/506 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDLr3.OpsF h=151b B=45ft; L=35ft; eave=5ft; Cat II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-0-0 to 2-1 Intedor(1) 2-6-0 to 11-0-0, Exterior(2) 11-M to 15-11-6, Intedor(1) 15-11-6 to 24-0-0, Extedor(2) 24-0-0 to 28-11-6. Interior(1) 28-11-6 to 36-0-0 zone;C-C for members and forces 8 -MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 5) • This truss has been designed for a live load of.20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 fall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except 6t=1b) 2=825, 8=825. Thomas A. Mbmi PE No.39380 MiTek USA, Inc. FL Cad 6634 6904 Parke East Blvd. Tampa FL 33610 Date: November 11,2019 Q WABNWG-Vedfy EeslgnparemeteramdR AD NOTES ON TN/SANBWCLUBEOMREKREFEAANCEPAGENl47413re, 1W0111a15BEFOBE USE Design valid for use only with MBek®tonnectors. Thh design Is based only upon parametersshown and Is form mtlNidual building component, not a truss system. Before roe, the building designer must verity the applicabllily of design parameters and properly Incorporate this design Into the overoll budding design &going Indicated is to prevent buckling of Individual rule web and/or chord members only. AddlAonat temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal lolury and propeM damage. For general guidance regarding the 69N Parke East Blvd. fabrication, storage, delivery. erection and bracing of trusses and buss systems WANSIM11 Quality Criteria, DSB-89 and BCSI Building Component Safety mfarmatbryrvodoble from Truss Rafe Instihde, 218 N. Lee Street, sure 312. Alexanddo, VA 22314, Tampa, FL W610 Job Truss Truss Type Ory Ply THE COTTAGE T18622012 M11455 A3 Hip 1 1 Jab Reference o liana) I,namuars puss, mc., ran nerce, rL o.aeu a ua eV zu rU MI I ea mousmes, Inc. man Nov I I ur rea:1 a zU IV raga 1 NI d dxS = 2x3 It 6.00 12 4 26 a 4,,6 = 3x4 = 4XS = 2.3 6 7 27 a 9 Scale = 1:60.3 17 16 15 14 13 12 3x6 = 4x6 = axis = 3x4 = 3xd = 4z5 = 3x4 = 4x6 = 94)-0 I 148-9 20.&7 c-o-o o.rvr J I? 1i Plate Offsets (XY)- 12:0-0-2 Edge] [4:0-5-4,0-2-0] [6:0,M Edger [8:0-5.4 0-2-01 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Ltd PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.45 Ved(LL) -0.33 14-15 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.62 Vetl(CT) -0.6214-15 >682 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.53 Hoa(CT) 0.14 10 Na n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Wind(L-) 0.4614-15 >910 240 Weight: 161111 FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or3-6-4 oc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-7-3 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (Ib/size) 2=1349/0-8-0, 10=1349/0-8-0 Max Horz 2=97(LC 11) Max Uplift 2=-825(LC 12), 10=-825(LC 12) FORCES. (Ib)-Max. ComplMax.Ten. -All forces 250(I1b) or less except when shown. TOP CHORD 23=3318r2529, 3-4=-3076/2343, 4-5=-3677/2800, 5-7=3677/2800, 7-8=3678r2802, 8-9=-3076/2343, 9-10=3318/2529 BOT CHORD 2-17=-2291/3118,15-17=-2004/2903, 14-15=-2567/3678, 12-14=-2012/2902, 10-12=-2299/3118 WEBS 3-17= 3321418,4-17=-269/424,4-15=-702/983, 5-15=-320/368,7-14=-363/368, 8-14=-705/984, 8-12=-269/424, 9-12=332/418 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; 1i=15ft;. B=45ft; L=35ft; eave=5ft; Cat. 11; Exp C; Encl.. GCpi=0.18; MW FRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Intedor(1) 2-6-0 to 9-0-0, Exterior(2) 9-0-0 to 13-11-6, Intedor(1) 13-113 to 26-0-0, Extedor(2) 26-M to 30-11-6, Intedor(1) 30-11.6 to 36-0-0zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This buss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=825, 10=825. Thomas A Alban) PE No.39380 MITek USA, Inc. FL Ced 8034 6904 Parke East Blvd. Tampa FL 33810 Date: November 11,2019 O WABNWG-Vedlydss19epa1emeren;.d BEADNOTES ON THISAND NCLUDED a amEKBEFENANCEPAGEdf47473rev. 10UP2015BEFOBE USE Design valid for use onrywith MRek®connectors, this design Is based only upon porameters shown. and 6 for an Individual building camponent not ��- a truss system. Before use. the bWtling designer mustverify the applicability of tlesign parameters and properly incorporate this design into ma overall buadmg deggm Bracing lnUicatetl is to prevent buckling of individual truss web and/or chord members only. AtldiHonal temporory and permanent bracing M!Tek- 9 always required for slabeily, antl to pe rent collapse with possible peocnal inlury and property damage. For general gddonce recording the fabraatiort storage, delivery, erection end bracing of trusses and Muss systems sseANS91F11 Quality CMikda, DS549 and BCSI Building Component 6904 Parke East Blvd. Safety Infonnationov aaoble from Truss Rote InsBhrte, 218 N. We Street. Suite 312, Alexandra, VA 22314. Tampa, FL M610 Job Truss Truss Type Oty Ply THE COTTAGE T18622013 M11455 ATA ATTIC 1 1 Job Reference a (tonal Chambers Truss, Inc., Fort Pierce, FL 8.320 s Oct 29 2019 MITek Industries, Inc. Mon NOV 11 07:29:19 2U19 rage 1 ID:AXCVr6ubfdeoJ5ziCdyWPDyLFMw-Og7O0s1 O01 xAHRsOlYFNNS79uUfm6103XhMyKK7E ' iSD-0 22-03 1-0Q aStS 12-It-13 13b12 260e 21-fOd 26-Et 3l 3FI}Q 1 bits 1 aSt 1-I' S I s-0-0 t-16d H a-Sta 8-515 T140 4104 0-0.16 Scale =1:61.8 4.00 r12 3x6 - 3x6 3x5 � 3x5 5 6 7 8 18 16 15 13 3x4 II 5x8 = 3x4 = 3x4 = Sx6 = 3x4 II LOADING (psQ TCLL 20.0 TCDL 7.0 BCLL 0.0 ' BCDL 10.0 SPACING- 2-0-0 Plate Gdp DOL 1.26 Lumber DOL 1.25 Rep Stress lncr YES Code FBC2017/TPI2014 CSI. TC 0.51 BC 0.48 WB 0.51 Matrii DEFL Vert(LL) Vert(CT) Horz(CT) Wind(LL) in (loc) Well L/d -0.33 15-16 >999 360 -0.58 15-16 >726 240 0.11 11 n/a n1a 0.2715-16 >999 240 PLATES GRIP MT20 244/190 Weight: 186 lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 - TOP CHORD Structural wood sheathing directly applied or3-0-15 oc puffins. BOT CHORD 2x6 SP 240OF 2.0E BOT CHORD Rigid ceiling directly applied or7-5-13 oc bracing. WEBS 2x4 SP No.3 *Except* WEBS 2 Rows at 113 pts 5-8 5-8: 2x4 SP M 30 REACTIONS. (lb/size) 2=1511/0-8-0, 11=1511/0-8-0 Max Horz 2=155(LG 11) Max Uplift 2=-698(LC 12), 11=-698(LC 12) Max Grav 2=1634(LC 18), 11=1634(LC 19) FORCES. (lb) - Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-4294/2007, 4-5=3767/1591, 5-6=-961/565, 6-7=910/561, 7-8=-961/565, 6-9=-3767/1591, 9-11= 4292/2008 BOT CHORD 2-18=-1778(4135, 16-18=-1778/4135, 15-16=-1223/3526, 13-15=-1787/4017, 11-13=-178714017 WEBS - 4-18=-96/330,4-16=-917/657, 5-16=-246/804,5-8=-2670/1014, 8-15=-246/804, 9-15=-917/657, 9-13=-98/330 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi-=i MW FRS (directional) and C-C Extedor(2) -1-0-0 to 2-6-0, Intedor(1) 2-6-0 to 15-0-0, Extedor(2) 15-0-0 to 24-11-6, Intedor(t) 24-11-6 to 36-0-0zone;C-C for members and tomes & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) 150.01b AC unit load placed on the top chord, 17-6-0 from left end, supported at two points, 5-0-0 apart. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Ceiling dead load (5.0 pi on member(s). 5-8 8) Bottom chord live load (40.0 psQ and additional bottom chord dead load (5.0 psQ applied only to room. 15-16 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joiut(s) except Qt=1b) 2=698, 11=698. 10) ATTIC SPACE SHOWNISDESIGNED AS UNINHABITABLE. Thomas A. Albani PE No.3936D MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: November 11,2019 Q WARNING-Vedfydeslgnparomelersand READNOMSON W6MDINCLUDEDMIFEKREFERANCEPA0EM&74Mrs. lWeV2015DEFOREUSE Design valid for use any ur m MeekO connectors. Mils design Is based only upon parameters shown, and B for an Individual bu0tling component, not • a Truss system. Before use. the building designer must vedfy me applicability of design parameters and propedy incorporate mis design Into the overall tiuld'mgdesign.Bracing Indcotecil Is to ons,tent buckling of Individual trusivielb ondfor chord Members only. Additional temporary and pennonentbrocing MiTek' Is alwoys required for staba6y and to prevent collapse with possible personal injury and property damage. For general guidance regarding me fabrication storage, delivery, erection and bmcing of trusses and huss systems. seeANSVWI1 6uT2 CRarl ; DSBA9 and SCSI Building Component 69M Parke East Blvd. Safety lnformatbrnvalable from Truss Plate Institute. 218 N. Lee Street. Suite 31Z AlexaMrla VA 22 14. Tampa. FL 33610 Job Truss Thus Type O)y. Ply M11455 ATB ATTIC 1 FECOTTAGET18622014 1b Reference (optional) unamoers I nlss, Inc., Fort Fierce, FL 8.32u s LIVE 2u 2u1u Inc. Man Nov 11 U1: 11: 12Wll Scale-1:60.7 4.00 12 6x8 = 6x6 = 4 21 22 23 24 25 26 5 14 '" 12 11 '" 9 3x4 II 5x6 3x4 = 3x4 = 5x6 = 3.4 II 0.515 I !X-I 2w-_1.n 4.a&n1 35-0-0 Plate Offsets (XY)-- [2:0-5-2 0-1-10] [4:0-3-8 0-2-31, [5:0-3-8 0-2-31 17:052 0-1-101 LOADING (psf) SPACING- 2-M CSI. DEFL. in (loc) Well List PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.64 Vert(LL) -0.31 11-12 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.48 Vert(CT) -0.5711-12 >743 240 BCLL 0.0 ' Rep Stress Incr YES WB OA6 Hoa(CT) 0.11 7 n/a n/a BCDL 10.0 Code FBC2017(rP12014- Matrix -MS Wind(LL) 0.2711-12 >999 240 Weight: 180 lb FT=20% LUMBER - TOP CHORD 2x4 SP M 30'Except' 4-5: 2x6 SP 240OF 2.0E BOT CHORD- 2x6 SP 2400F 2.0E WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1513/0-8-0, 7=1513/0-8-0 Max Horz2=136(LC 11) Max Uplift 2= 697(LC 12), 7=-697(LC 12) Max Gmv 2=1641(LC 18), 7=1641(LC 19) BRACING - TOP CHORD Structural wood sheathing directly applied or3.0-4 oc pudins. BOTCHORD Rigid ceiling directly applied or 7-4-12 oc bracing. FORCES. (lb) - Max ComplMax Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2.3- 4303/2049, 3A-2800/1611, 4-S=-3601/1567, 5-6=-38D0/1611, 6-7=-4302/2050 BOT CHORD 2-14=-1817/4128, 12-14=-1817/4128, 11-12=-1255/3598, 9-11=-182154024, 7-9_ 1826/4024 WEBS 3-14=-84/310,3-12=-826r673,6-9=-84/310, 5-11=-216(772, 4-12= 216f772, 6-11=-826/673 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10: Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=151t; B=45ft; L=35tt; eave=5ft; Cat. II; Exp C; Encl.,.GCpi--0.18; MWFRS (directional) and C-C Emeriar(2) -1-0-0 to 2-6-0, Intedor(1) 2-6-0 to 13-0-0. Exterior(2) 13-0-0 to 17-11-6. Interior(1) 17-11-6 to 22-0-0. Exterior(2) 22-M to 26-11-6. Interior(1) 26-11-6 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) 150.O1b AC unit load placed on the top chord, 17-6-0 from left end, supported at two points, 5-0-0 apart 4) Provide adequate drainage to prevent water pending. 5) This truss has been designed for a 10.0 psf bottom chord live toad nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Ceiling dead load (5.0 psi) on member(s). 4-5 8) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0.pst) applied only to room. 11-12 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) except (jt=lb) 2=697, 7=697. 10) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE. Thomas A. Alban! PE No.39360 MiTek USA, Ina FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: November 11,2019 0 WARN9G-VerKy Cesrynpmzmefersand READNOTES OMMISANDINCLUDEDMI KREFERANCEPAGEM674mrev. tatsa2U15BEFOREUSE. Deslgnvold foruseonlywith MRek®connactors. IDb design bbaseConlyupon peramefensnown, and is foran lndMdual buading component, not - a buss system. Before use, Me building designer must verify toe oppricabBity of design parameters and properly Incorporate this design Into Me overall butdingdedgn &ocNglndicotedbtowr entbuckllrgofind dudM "bwdlorchordmembenoNy. Addlhonaltemporary and permanent bracing Is always required for stabeily and to prevent calopse with pos able personal Wa<y care property damage. For general guidance, regarding the tddk:bnort storage, tleWery, erection ata boc4g of trusses and huts systems seeAN31/IPII Cual2ry1CMerlp, DSBd9 and BGSI Building component Safely Inforrilutbrava0obe from Truss Hate Institute, 218 N. Lee Sheet Suite 312. Alexandria VA 2214. �I1 MOW 6904 Parke East BN4. Tampa, R. Met Job Truss Truss Type Oly Ply T78622015 M11455 B Hip 1 �THECOTTAGE 1 Job Reference (optional) unamaers I was, Inc., ran rierce, rL oam b VIA 4 V 4V ro nii I e¢ Inuu5,nee, nm. mV, uvVv , , V f of 3x5 = 24 4.00 FIT 5a8 = 4.8 = 67 8 2x3 \\ 3x4 i 4xB -- S 3 4� 15 17 16 3x6 = 3x4 = Sx12 = 2.00 12 2x3 G Sx6 9 SxB MTiBHS c 10 11 14 7x8 MTIBHS = 25 Scale=1:62.3 302 = B-1-4 9-11-1 1580 2 o P4-11-0 25-0-12 35-0-0 I 7 er o-1 e I Plate Offsets(XY)— [2:D-1-2Edae1 [3:0-3-0Edael [6:0-5-120-2-121 [6:0-M0-1-121 P:0-1-120-0-01 [8:0-540-2-0I [11:0-0-0Edgel [12:0-1-15Edge] LOADING (psf) SPACING 2-0-0 CSL DEFL in (loc) Udell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.73 Vert(LL) -0.54 14 >784 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.94 Vert(CT) -0.98 14 >429 240 MT18HS 244/190 BCLL 0.0 ' Rep Stress [nor YES WB 0.76 Horz(CT) 0.36 12 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MS Wind(LL) 0.74 14 >570 240 Weight: 1641b FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-4-1 oc puffins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1Row at micipt 9-15 REACTIONS. (lb/size) 2=1349/0-8-0, 12=134910-8-0 Max Horz 2=155(LC 11) Max Uplift 2=-825(LC 12), 12=-825(LC 12) FORCES. (lb) - Max CompJMax. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-3239/2355, 4-5=-3010/2262, 5-6=-2338/1838, 6-7= 2192/1812, 7-8=-2205/1818, 8-9=-2754/2106.9-10=-538313914I 10-12=-5697/4073 BOT CHORD 2-17=-2119/3038, 16-17=-192512802, 15-16=-175at2665, 14-15=-3567/5158, 12-14=3794/5420 WEBS 8-15=-643/1022, 9-14=-1284/2004, 10-14=-335/317,7-16=-263/463, 9-15=-2822/2043; 5-16=-719/552, 5-17=-288/536,4-17=-411/382, 8-16=-697/471 NOTES- 1) Unbalanced roof live loadshave been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft;.3=45ft; L=35ft; eave=5ft;.Cat. II; Exte C; Encl.. GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-" to 2-", Interior(1) 2-6-0to 15-0-0, Exterior(2) 15-M to 24-11-0, Interior(1) 24-11-0to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load noncorx:urrent with any other live loads. 6) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joints) 12 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others). of truss to bearing plate capable of withstanding 100 Be uplift at joint(s) except (jt=lb) 2=825, 12=825. Thomas A. Alban) PE No.39380 MTek USA, Ire. FL Cad 6634 6904 Parke East BNO. Tampa FL 33610 Date: November 11,2019 Q WARNWG.Ve fydeslgnp efems dREADNOT£SONMOMDWCLUDWWR REFERANCEPAGEM&74m rev. 1O 015aEFOREUSE Design valid for use only with MBekee connectors. This desgn Is based only upon parameters shown. and Is for an Individual bustling component, not ■■ a toss system. Before use, the ouadng des0ner must verify Me applk:abtiity of design parameters and properly incciporola this design Into me overall bullding design. Bracing Indicated Is to budding of individual toss web and/or chord members only.Additional temporary and permanent bracing MITek prevent Is always required for stability and to prevent collapse vM possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection ehd bracing of trusses and muss systems. seeANSWI I QuamBtyCMate. DS049 and SCSI Building Component 69M Parke East Blvd. Safety NfprmMWltwoaode from Toss Rate Institute. 218 N. Leo Steel. Suite 31Z Alexandria. VA 22314. Tampa. FL 33610 Job Truss Truss Type Cty Ply THECOTTAGE T78622016 M11455 B1 Hip 1 1 Job Reference (optional) unamoem I mss, Inc., ran rierce, rL 4.00 FIT aAZu s um eu zule mi tex Inauslnes, mC. Man Nov 11 UCz9:zu zule regal aojsnCdyW PDyLFMw-I RMxsE5x3GSc13A9GOKKrbdlsWkPnKBLaM11g7yKK7A 5x5 = 2x3 II 4x10 = 4 24 5 25 26 27 6 five a Scale = 1:61.3 15 14 13 3x5 = 2x3 II 3x4 = 5xB MT18HS= 3x12 = 2.00 12 E412 7-34i 13-0-0 15E-0 22-0-0 24-11-02&D-12 35-a0 'Ne nia� lain o.an aan v.t to o.tt Plate Offsets (X,Y)-- t2:0-1-6,Edael, 16:0-7-0,0-2-01. 19:0-1-15 Edgel LOADING (psf) SPACING. 2-0-0 CSI. DEFL in (loc) Udell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.72 Vert(L-) -0.55 11-12 >757 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.94 Vert(CT) -1.0212-13 >410 240 MT18HS 244/190 BCLL 0.0 ' Rep Stress Incr YES We 0.76 Horz(CT) 0.35 9 n/a n/a BCDL 10.0 Code F13C2017frP12014 Matrix -MS Wind(L-) 0.7611-12 >550 240 Weight: 160 to FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD 2x4 SP M 30 BOT CHORD WEBS 2x4 SP No.3 WEBS REACTIONS. (lb/size) 2=1349/0-8-0, 9=1349/0-8-0 Max Horz 2=-136(LC 10) Max Uplift 2=-825(LC 12), 9=-825(LC 12) FORCES. (lb) - Max. Comp,/Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3313/2430, 3-4=-2689/2057, 4-5=-2521/2030, 5-6=-2517/2023, 6-7=3409/2582, 7-8=-5345/3923, 8-9=-5700/4162 BOT CHORD 2-15=-2200/3109, 14-15=--2POO/3109, 13-14=-1709/2521, 12-13=-2267/3348, 11-12=-3543/5101, 9-11=-3878/5424 WEBS 4-14= 343/531, 6-13=-1030/679, 6-12=-814/1242, 7-11=-1344/1986, 8-11= 394/387, 7-12=-2262/1640,3-14=-701/544 Structural wood sheathing directly applied or 2-4-5 oc puffins. Rigid ceiling directly applied or 2-2-0 oc bracing. 1 Row at midpt 6-13 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2pst BCDL=3.Opsf; h=15ft; B=45ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl.. GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-M to 2-6-0, Intenor(1) 2-6-0 to 13-0-0, Extedor(2) 13-0-0 to 17-11-6, Inlenor(1) 17-11-6 to 22-0-0, Extedor(2) 22-0-0to 26-10-0, Intedor(1) 26-10-0 to 36-0-0 zone;C-C for members and forces & MWFRS.for reactions shaven; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4),All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) except at=lb) 2=825, 9=825. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Ced 6634 6904 Parke East Blyd. Tampa FL 33610 Date: November 11,2019 Q WARNING- Vedtydesfenps...Wrsend REAONOTES ON TNISANDINCLUOEDM KBEMRANCEPAGEM&74 mv. Ina,2015BEFOBE USE. Design valid for use only with MTek9connectors. This de9gn h based only upon parameters shown, antl I5 for on InWduai building component, not - a fuss system. Before use, the bulcng designer musiverity me applicability of tleslgn parametersantl properly Incorporate this design Into the overall buIlchg design. Bradng lndeated B to prevent buckling of hdK6d=l Muss web and/or chord members only. Additional femporary and permanent bracing MiTek' Is always required for stab9ny, and to prevent collapse with pasebie personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems. seeAN5VTP11 Quality Criteria, DSB-e9 and BCSI Building Component 5904 Parke East Blvd. Safely mfosmatbravollabie from Truss Rote Institute. 218 N. We Street Suite 312 Alexantlda. VA 22314. Tampa, FL M610 Job Truss Truss Type 01y Ply THECGTTAGE T76622017 M11455 B2 HIP 1 1 Job Reference (optional) unamoers i russ, Inc., ron rlerce, rL 4x8 = 4.00 F12 4 a.Jm 5 V. ztl za Itl ran nx nNusuiei, mu. 20 II 4x8 = 2z3 II 25 26 5 27 28 6 7 2x3 raye , r9cWgaVpOnlMayKK79 6-0 0- Scale=1:60.4 10 3x4 = 2x3 11 US = 4xB = 2x3 II 3x5 = 3x4.= 502 MT18HS = 7-7.2 I 17-0.0 I 17.6cl,.0 I 24n.0.n.0-0 35.0.0 c1-'JJf a.1Mn I Plate Offsets (X Y)— [4:0-5.4 0-2-01 I6:0-5-12 0-2-01 [9:D-0-14 Edael [71:0-6-0 0-3-01 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Gap DOL 1.25 .TC 0.51 Ven(LL) 0.47 11-22 >257 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.62 Vert(CT) -0.3011-22 >406 240 MT18HS 2441190 BCLL 0.0 ' Rep Stress [nor YES We 0.56 Horz(CT) 0.04 11 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 164 lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD 2x4 SP M 30 BOT CHORD WEBS 2x4 SP No.3 WEBS REACTIONS. (lb/size) 2=941/0-8-0, 11=1427/0-8-0, 9=330/0-8-0 Max Horz 2= 117(LC 10) Max Uplift 2=-575(LC 12). 11=-1078(LC 12), g=-007(LC 12) Maz Gmv 2=947(LC 21), 11=1427(LC 1), 9=361(LC 22) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2065/1469, 3-4=-1560/1164, 4-5>1250/920, 5-6=-1250/920, 6-7=-293/21 BOT CHORD 2-16=-1281/1923, 14-16=-1281/1923, 13-14— 861/1454, 12-13=-79/380, 11-12=-70/352 WEBS 3-14=598/530, 4-14= 261/410, 4-13=-244/257, 5-13=-428/461, 6-13=-l151/1459, 6-12=-372f753,7-11=-940/0, 8-11=268/694 - Structural wood sheathing directly applied or 4-7-2 oc puffins. Rigid ceiling directly applied or 6-M oc bracing. 1 Row at midpt 6-13 NOTES- 1) Unbalanced root live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL--4.2psf; BCDL=3.Opsf; h=1511; B=45ft L=35tt; eave=5ft; Cat. II; E1gr C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-0-0 to 2-6-0, Interor(1) 2-6-0 to 41-0-0, Exierior(2) 11-0-0 to 15-11-6, Inteaor(1) 15-11-6 to 24-0-0, Extedor(2) 24-0-0 to 28-11-6, Inteaor(1) 28-11-6 to 36-M zone; porch right exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate gap DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 pat bottom chard live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of.20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) except Qt=lb) 2=575, 11=1078, 9=407. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Carl 6634 6904 Parke East Blvd. Tampa FL 33610 Date: November 11,2019 Q WARNING. Verily Ceslgnamersters antl BEAD NOTES ON THISAND INCLUDEDMITEKREFEBANCEPAGE0I-7473 rev. 10,1131201SBEFOREUSE Design volid for use only wlth fill connectors. This design Is based only upon parameters shown, antl Is for an Indivtual building component, not ��- - atruer system. Before use, the bWtling designer must verythe opplicabaity of tleslgn parameters and properly Incorporate tw design Into Me overall building tleslgn. Bracing indicated a to prevent bucWing of individual truss web and/or chord members only, Additional temporary and permanent bracing MiTek' Is always required for stabalty and to prevent collapse wiM possible personal Injury and property damage. For general guidance regarding the Parke East Blvd. fobricotbn. storage, delivery, erection and bracing of trusses and truss systems. seegN5U1P11 Quo'y Critelli.. DSB-89 and BCSI BU9dfng Component 6904 Safety Mformatlonavoitoble from Truss Plate Institute, 21 B N. Lee Street Suite 312, Aleeandda, VA 22314. Tampa, FL 33610 Job Truss Truss Type Oly Ply THE COTTAGE T1862201B M11455 83 HIP 1 1 Job Reference (optional) unroll , russ, no., ran rlerce, rL i1-a-q 6.70-13 -0- 6-10-13 48 = 4.00 12 4 1;-4 d o.Jzu s v.'e I.Ie ml rex mou5'u.a. 'nu. ,vNn nw , , V r:<tl:c] cu,0 rays , Scale = 1:60.4 2x3 (I 3x6 = 3x8 = 2.3 II 3.6 = 526 6 7 27 8 9 2x3 3x4 = 3,6 = 3.8 = 2x3 II 5x10 = 3x6 = 3x4 = LOADING lost) SPACING- 2-0-0 CSI. DEFL. in (too) Vdefl L/d PLATES GRIP TCLL 20.0 Plate Gdp DOL 1.25 TC 0.45 Vert(LL) 0.48 13-23 >252 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.48 Vert(CT) -0.32 13-23 >380 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.50 HOrz(CT) 0.04 13 n/a n1a BCDL 10.0 Code FBC20171TP12014 Matdx-MS Weight: 163 lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or4-11-9 oc purins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 *Except* WEBS 1 Row at midpt 7-13 8-13: 2x6 SP No.2 REACTIONS. (lb/size) 2=86010-8-0, 13=1711/0-8-0. 11=127/0-8-0 Max Horz 2=-97(LC 10) Max Uplift 2=-5301LC 12), 13- 1237(LC 12). 11=-293(LC 12) Max Grav 2=869(LC 21), 13=1711(LC 1), 11=161(LC 22) FORCES. (lb) - Max CompJMax. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3- 1835/1348, 3-4=-1580/1150,4-5=-1382/984, 5-7=-1382/984,7-8=-636/851, B-9=-658/876, 9-10=-672/903, 10-11=-247/672 BOT CHORD 2-17- 1173/1714, 15-17=-869/1479, 14-15=-106/635, 13-14=-106/635, 11-13=-611/320 WEBS 3-17=-356/442, 4-17= 281/437, 8-13=-455/397, 5-15=-312/354,7-15=-759/899, 7-13=-1620/1109,10-13=-528/804 NOTES- 1) Unbalanced roof live loads have been considered forthis design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15N; B=45ft; L=35f : eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.1Q MW FRS (directional). and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 9-", Exterior(2) 9-0-0 to 13-11-6. Interior(1) 13-11-6 to 26-", Exterior(2) 26-0-0 to 30-11-6, Interior(1) 30-11-6 to 36-0-0 zone; porch right exposed;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 pat bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100.Ito uplift at joint(s) except at=lb) 2=530, 13=1237, 11=293. Thomas A, Albani PE No.39380 MTek USA, Inc. FL Cad 6634 6904 Parka East Blvd. Tampa FL 33610 Date: November 11,2019 Q WARNING- Vedyydce9nparamefasend READNOTES ON THMAND INCLUDED 111RENREFERANCEPAGEM67473 rev. IdOYle15BEFORE USE Design valid for use only with Wake, connectors; This design is based only upon parameters shown, and Is for an Individual burring component, not ��- • atruss system. Before use. the bullring designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with goo le personal Injury and property damage. For general guidance regarding the fdbncotion, storage, delivery, erection and bracing of trusses and truss systems, seeAN81/IPII gil Cmeda, OSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Infarmatlondvallabie From Truss Plate Institute. 218 N. Lee Street Suite 312 Alexandra, VA 22 14. Temp., FL 33610 Job Truss Truss Type O!y Ply THE COTTAGE T18622019 M11455 GRA Hip Girder 1 2 Job Reference (optional) unampers i russ, Inc., ran rierce, rL �11 _ 5x8 MT18HS = 4.00 F12 3x4 = 5x8 MT1SHS = 3x4 = 3 23 24 4 25 26 27 528 29 30 31 32 6 33 34 5x8 MTI BHS = 7 Scale=1:6D.3 16 35 15 36 14 37 3B 73 39 4041 42 t2 43 11 44 10 4x8 = 2x3 II Sx6 WB= 4x4 = 3x8 = 4x4 = 5.6 ,wa= 2x3 II 4x6 = LOADING (psf) SPACING- 2-M C51. DEFL, in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.65 Vert(L-) 1.04 12-13 >405. 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.96 Vert(CT) -1.04 12-13 >402 240 MT18HS 244/190 BCLL 0.0 ' Rep Stress Incr NO WB 0.65 Horz(CT) 0.19 8 n/a nJa BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 316 lb FIF=20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 - - TOP CHORD BOT CHORD 2x4 SP M 30 BOT CHORD WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=283310-8-0, 8=2835/0-8-0 Max Harz 2=78(LC 24) Max Uplift 2=-2199(LC 8). 8=-2255(LC 8) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250.(lb) or less except when shown. TOP CHORD 2-3=-7950/6160, 3-4=-10549/8106, 4-5=-11568/9029, 5-6=-11568/9029, 6-7=-10563/8444, 7-8=-7952/6320 BOTCHORD 2-16=-5728(7490, 14-16=-576117530,.13-14=-7944/10549, 12-13=-8281/10563, 10-12= 5910/753118-10=-588117492 WEBS 3-16=-5371685, 3-14=-2389/3417,4-14=-1134/1004, 4-13=-1015/1162,5-13=-538/487, 6-13=-644/1146,6-12=-945/674,7-12=-2596/3432,7-10=481/670 Structuml wood sheathing directly applied or4-1-5 oc purlins. Rigid ceiling directlyapplied or 5-1-15 oc bmcing. NOTES- 1) 2-plytruss to be connected together with 10d (0.131'x3') nails as follows: Top chords connected as follows: 2x4 -1 row at 0-7-0 oc. Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Webs connected as follows: 2x4 -1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (S), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15fb B=45f ; L=35ff, eave=5f ; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed fora 10.0 psf bottom chord live load nonconcument with any other live loads. 8) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=11a) 2=2199,8=2255. - Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cad 6634 6904 Parke East Elvd. Tampa FL 33610 Date: November 11,2019 Q WARNING -Verity design parnmeremend RE4W NOTES ON TNISANOINCLUO£OMR KREPERANCEPAGEMM174Mmr 10=015SUORE USE Dedgn valid for use only with Mfrokw connoctors.,lhis design Is based only upon parameters shown, and Is for an Individual bullding component, not ��- - a truss system. Before use. the building designer must verify the applicobYlty of design parameters and properly Incorporate ails design Into the overall building desgn. Bracing Indicated is to prevent buckling of lndlvidual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal lrJury and property damage, For general guidance regarding the fobriwMon. storage, delivery, election and bracing of fusses and truss systems, seeANSUTPII Quality Cdfeda. OSB49 and BC51 Buildhsp Component seat Pahl East Blvd. Safety Informafbnavollable from Truss Plate Institute, 218 N. Lee Street, Suits 312, Alexondao, VA 22314. Tampa, FL 33610 Job Truss Truss Type PlyTHE'COTTAGET16622019 M11455 GRA Hip Girder ry 2 Job Reference (optional) Chambers Truss, Inc., Fart Pierce, FL 6.320 sum 2e 2U19 MI I eK Industries, mc. Mon Nov 11 uC2a:3U Lulu rage I D:AXCVrGubfdeoJ5ziCdyW PDyLFMw-bnlaKdAKOPKd57CVAMyzd3Oz7K6iwVXNByEdaDyKK73 NOTES- 10) Hanger(s) or other connection devices) shall be provided sufficient to support concentrated load(s) 137 lb down and 231 Ib up at 7-0-0, 116 to down and 171 lb up at 9-0-12, 116 Ib down and 171 lb up at 11-0-12, 116 lb down and 171 lb up at 13-0-12, 11616 down and 171 It, up at 15-0-12, 116 Ib down and 171 lb up at 17-0-12, 116 lb down and 171 lb up at 17-11-4, 80 lb down and 59 lb up at 19-11-4,.80 lb down and 59111 up at 21-11-4. 1161b down and 171 Ito up at 23-11-4, and 116 lb down and 171 Ib up at 25-114, and 137 lb dam and 231 Its up at 28-0-0 on top chord, and 4691b down and 578 Ib up at 7-0-0, 80111 down and 29111 up at 9-0-12, BO lb down and 29 Ile up at 11-0-12, 80 to down and 29 Its up at 13-0-12, 80111 down and 29 lb up at 15-0-12, 80 lb down and 29 lb up at 17-0-12, 80 lb down and 29 lb up at 17-11-4, 1791b down and 2761b up at 19-114, 179 Its down and 276 lb up at 21-114, 80 lb down and 29 lb up at 23-114, and 80 Its down and 29 Ib up at 25-114, and 469 lb down and 578 lb up at 27-114 on bottom chord. The design/selection of such connection device(s) Is the responsibility of others. LOAD CASE(S) Standard 1) Dead+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pig Vert: 1-3— 54, 3-7=-54, 7-9=-54, 17-20=-20 Concentrated Loads (Ib) Vert: 3=-116(F) 7=-116(F) 16=469(F) 10=-469(F) 23=-116(F) 24=-116(F)25=-116(F) 27=-116(F) 28— 116(F) 29=-116(F) 30=-6(F) 32_ 6(F) 33=-116(F) 34=-116(F) 35=-63(F) 36=-63(F) 37=-63(F) 38=-63(F) 39=-63(F) 40=-63(F) 41=-179(F) 42=-179(F) 43=-63(F) 44=-1 O WARNING - Verity Eesignpammetetrand READ NOTES ON TN/SANDINCLUDED UNEKREFERANCEPAGEMIF7J .J .. local BEFORE USE Design valid for use only with Mite& connectors. This design Is based only upon parameters shown, and Is for an Individual bulltlNg component, not a truss system. Before use, the, bulldIng designer must verify Me applicability of design parameters and properly Incorporote this tleslgn Into the overall building tleslgn. Bracing Indicated Is to prevent budding of Individual truss web and/or chard members only. Additional temporary and permanent brociog M)Tek Is always repaired for stability and to prevent collapse with passible personal injury end property damage. For general guidance regarding me fabricoflon. storage, delivery, erection and brocing of trusses and truss systems, seeANSVIPI1 Qua[ Hv CMoM, DSB-89 and BCBI Building Component 6900PerKe East Blvd. Safety Informafbmvalloble from Truss Plate lml ltute, 218 N. Ise Street, Suite 312, Rexantlrla. VA 22 14. Tampa, FL 33610 Jab Truss Truss Type City Ply M11455 GRB HIP GIRDER 1 1b FECOTTAGET78622020 Reference (optional) unamoers I FUSS, Inc., Von rlerce, 1-1. O.... . V.' CO GV I el.. tlM1 III..]a I0.. II IY. I�1.II I— 11—.ca.ac cv,a Scale =1:60.3 2.3 It - 4.00 12 6x8 3xd = 4x6 = Sx12 = 2x3'11 seats MT18HS = 3 25 426 27 28 29 5 6 30 731 32 33 34 8 35 Rep 9 2 10 11 n N b b 18 36 17 16 37 3a 39 15 40 41 14 4243 46 13 65 12 46 = 2x3 11 5x6 WB= 5x10 = 2x3 11 7xl4MT18HS = 2x3 It 3x4 = 3xd = 7-0-0 11-5-8 15-T1-0 20-4-8 24-10.1 28-0.0 35-0-0. 0 45-8 4S8 l 4-5-8 4-&B 3-2-0 700 Plate Offsets (X V)-- [3:0-5-12 0-2-12] [6:0-3-0 Ednel [9'0-5-8 0-2-81 [13.0-5-12 Ednel LOADING (psf) SPACING- 2-0-0 CSI. DEFL, in (lop) Well Ud PLATES GRIP TOLL 20.0 Plate Grip DOL 1.25 TC 0.76 Vert(LL) 0.38 16 >782 240 MT202441190 TOOL 7.0 Lumber DOL 1.25 BC 0.76 Vert(CT) -0.43 15-16 >690 240 MT18HS 2441190 BCLL 0.0 ' Rep Stress Incr NO W B 0.98 Horz(CT) 0.09 13 n/a Fda BCDL 10.0 Code FBC2017frP12014 Matrix -MS Weight: 163 lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood.sheathing directly applied or2-11-12 oc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or4-3-12 oc bracing. WEBS 2x4 SP No.3 *Except* WEBS '1 Row at midpt 7-13 4-15,7-15: 2x4 SP M 30, 8-13: 2x6 SP No.2 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=1602/0-8-0, 13=4305/0-8-0, 10=-239/0-8-0 Max Horz 2=78(LC 7) Max Uplift 2=-1201(1-C 8), 13=-3423(LC 8), 10=-566(LC 25) Max Grav 2=1604(LC 17), 13=4305(LC 1), 10=212(LC 7) FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4134/3062, 3-0=-4232/3012, 4-5=3226/2172, 5-7= 3226/2172, 7-8=-2413/3408, e-9=-2436/3435, 9-10= 732/1777 BOT CHORD 2-18=-2791/3872, 16-18=-2825/3913, 15-16=-2849/4232, 14-15=-206/680, 13-14=-206/680, 12-13=-1623/722, 10-12=-1668/785 WEBS 3-18=-542/665, 3-16=-92/505, 4-15=-1145/952, 5-15=-551/497, 7-15=-2056/2887, 7-14=0/366,7-13=-4569/3111,8-13=-414/347, 9-13=-2479/2391, 9-12— 1024/780 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASIDE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2ps1; BCDL=3.Opsf; h=1SM B=45tt; L=351t.eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) All plates are MT20 plates unless othenviseindicated. 5) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with anyother live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in ail areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joints) except Qt=lb) 2=1201, 13=3423, 10=566. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support Concentrated loads) 137 lb down and 231 Ile up at 7-0-0, 1161b down and 171 lb up at 9-0-12, 116 lb down and 171 lb up at 11-0-12, 116 to down and 171 Ib up at 13-0-12, 116 lb down and 171 Ib up at 15-0-12, 116 Ito down and 171 lb up at 17-0-12, 116 lb down and 171 lb up at 17-11-4. 116 lb down and 171 lb up at 19-11-4, 116 lb down and 171 lb up at 21-11-4,116 lb down and 171 lb up at 23-11-4, and 80 to down and 59 lb up at 25-11-4. and 106 Ile down and 119 lb up at 28-0-0 on top chord, and 469 lb down and 578 lb up at 7-0-0, 80 It, down and 29 lb up at Thomas A. Albani PE No.39380 9-0-12, 80 to down and 29 lb up at 11-0-12, 80 lb down and 29 lb up at 13-0-12, 80 lb down and 29 lb up at 15-0-12, 80 lb down MTek USA, Inc. FL Cart 6634 and 29 lb up at 17-0-12, 80 Ito down and 29 Ib up at 17-11-4, 80 lb down and 29 Ito up at 19-11-4. 80 lb down and 29 Ib up at 6904 Parke East Blvd. Tampa FL 33810 21-11-0, 80 Ito down and 29 to up at 23-11-4, and 179 lb down and 2371b. up at 25-11-4, and 5851b down and 727 lb up at 27-11-4 on bottom chord. The design/selection of such connection device(s) Is the responsibility of others. Date: 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (8). November 1 1,2019 Q WARNING -Verity dealgnpammeteraand BEAD NOTES ON MIS AND INCLUDED M/1EKBE17RANCEPAGEMh7473rev. 102132015BEFONEUSE Design valid for use only with MROW Connectors. IDh design a based only upon parameters shown, and u for an Individual building component, not a truss system. Before use, the building designer must verify the appllcablllN of design parameters and properly Incorporate this design Into the overall beading design. Bracing Indicated is to prevent buckling of Individual Ines web and/or chord members oNy. Additional temporary and permanent bracing M[Tek* is olwoys required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeAN3VB'I I ®IlalBy Cdteda, DS8419 and SCSI Building Component Inlormotionovollable from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22 14. 6904 Parke East Blvd.Saloty Tampa, FL 33810 Job Truss Truss Type Oty Ply THE COTTAGE ' T18622020 M11455 GRB HIP GIRDER 1 1 Job Reference o lional unarri r nsss, Inc., ron runce, rt- , os— I D:AXCVr6ubfdeoJ5riCdyW PDyLFMw-XAPUJCayl aKKRM ulrs_RiUVHxasNOKxgeGlle6yKK71 LOAD CASE(S) Standard 1) Dead+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plo Vert: 1-3=-54, 3-9=-54, 9-11=-54, 19-22— 20 Concentrated Loads (lb) Vert: 3=-116(B)6=-116(B)9= 6(B) 18=-469(B) 12=-585(B) 25=-116(B) 2116(8) 27=-116(B)29=-116(B)30=116(B)31=-116(8)33=-116(B)34=-116(B) 35=.6(B) 36=-63(8) 37=-63(B) 38=-63(B)39=-63(B) 40=-63(B)41=-63(B)42=-63(B)43— 63(B) 44=-63(B)45=-179(B) ,&WARNING-Verltydealen Paramefen and READ NOTES ON TRISAND INCLUDED MREKREFERANCEPAGEMIA74M.Y. 16N12015 BEFORE USE. Design volld for use only with M6ek® connectors. This design Is based only upon parameters ' shown , and Is for an Individual bullding component, not �1 a hum system. Before use, the butting designer must verify the of polcotailty of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to buckling of lndivlldual hum web and/or chord members only. Addlllonal temporary and permanent brocing j M!Tek' prevent Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance legal the fabrication, storage, delivery, erection cnd bracing of trusses and hum systems seeANSVMII Cuallly Citadel DSB49 and SCSI Building Component 6904 Parke East Blvd. Safety Informelencvailoble from Truss Plate Institute. 218 N. Lee SVBet, Suite 312, Alexandria, VA 22 14. Tampa, FL 33610 Job Truss Truss Type Oty Ply , ' T78622021 M11455 J1 JACK -OPEN 8 1 �THECOTTAGE Joh Reference o tional Chambers Truss, Inc., Fort Pierce, FL LOADING (psq SPACING- 2-0-0 CSL TCLL 20.0 Plate Grip DOL 1.25 TIC 0.18 TCOL 7.0 Lumber DOL 1.25 BC 0.02 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2017/TP12014 MaMx-MP LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 3=9/Mechanical, 2=118/0-8-0, 4=0/Mechanical Max Hom 2=48(LC 12) Max Uplift 3=-4(LC 9), 2— 140(LC 12) Max Gran, 3--1 O(LC M. 2=118(LC 1), 4=17(LC 12) FORCES. (Ib) - Max. Comp./Max. Ten. -All tomes 250 (lb) or less except when shown 3.3Zu sum 2B Zulu MI I eK InGG510eS, Inc. Men Nov l l u/:ze:33 Zulu rage 1' ID:A%CVrGubfdeoJ5ziCdyW PDyLFMw-OMzjyfCCjKiBybx4sUVgfl2boYNB7OTptwSHAYyKK70 3x4 = DEFL. in (too) Well Ud Vert(LL) -0.00 5 >999 360 Vert(CT) -0.00 5 >999 240 Horz(CT) 0.00 4 n/a n/a Wind(LL) -0.00 5 >999 240 Scale = 1:6.1 PLATES GRIP MT20 244/190 Weight: 5lb FT=20( BRACING - TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc puffins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASIDE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsh h=15ft; B=45ft; L=24ft; save=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Extedor(2) zone; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrem with any other live loads. 3) ' This truss has been designed for a live load of 20.0psf on the bottom chord In. all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) 3 except (jt=lb) 2=140. Thomas A Albans PE No.39380 MiTek USA, Inc. FL Cut 6634 6904 Parka East Blvd. Tampa FL 33610 Date: November 11,2019 AWARNING- varllydea/gnparamatersand READ NOTES ON THIS AND/NCLUDEDMREKBEFEBANCE PAGE MIF74M.. 10413W015 BEFORE USE. Deslgn valid for use only with MOek® connectors. This design Is based only upon parameters shown, and Is for on Indlvlduol building component, not ��- a truss system. Before use, the building designer must verity the appliccUllty of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse wlth possible personal Injury and property damage.. For general guldonce regording the fobticatlon. storage, delivery, erection and bracing of trusses and truss systems. seeANSVrPII Quality Cmerla, DSBA9 and SCSI BuBding Component 6904 Parke East Blvd. Safety Informallonow llcble from Truss Plate Institute. 218 N. Lee Street, Suite 312, Aiexandrlo. VA 22314, Tampa, FL 33610 Job Truss Truss Type Cry Ply THE COTTAGE T78622022 M11455 J3 JACK -OPEN 8 1 Job Reference (optional_ GrlannDers INSs. Inc., Mon Force, hL 3x4 = d.azu s um ze eme ml I eK inausmes, mc. man Nov 11 urzsaa zulu rage t ID:AKCVr6ubfdeoJSziCdyW POyLFMw-OMziylcgKiBybx4sUVgR2Z3YJo7OTptwSHAYyKK70 LOADING (psf) SPACING- 2-0-0 CS'. DEFL in (lac) VdeO Ud TCLL 20.0 Plate Gdp DOL 1.25 TC 0.29 VeR(LL) 0.02 4-7 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.30 Vert(CT) -0.01 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES We 0.00 Horz(CT) -0.00 3 rda Iva BCDL 10.0 Code FBC2017/TP12014 Matdx-MP LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 Seale - 1:9.4 PLATES GRIP MT20 244/19D Weight: 11 lb FT=20% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc puffins. BOT CHORD Rigid ceiling directly applied or 10-0.0 oc bracing. REACTIONS. (lb/size) 3=63/Mechanical, 2=172/0-8-0, 4=36/Mechanical Max Horz 2=85(LC 12) Max Uplift 3=-67(LC 12), 2=-207(LC 12), 4=-51(LC 12) Max Gray 3=63(LC 1), 2=172(LC 1), 4=50(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft B=45D; L=24f1; eave=oft Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extenior(2) -1-0-0 to 2-0-0, Intenior(1) 2-0-0 to 2-114 zone; pooh left and night exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads, 3) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at Joint(s) 3, 4 except Qt=lb) 2=207. Thomas A Alban! PE No.39380 MiTek USA, Inc. FL Cert $634 6904 Parke East Blvd. Tampa FL 33610 Date: November 11,2019 Q WARNING -Verily dadgnparamafarsand READ NOTES ONTNISAND/NCLUDEDMREKREFERANCEGAGEMIF74YJrev. tOPo12015BEFOREUSE Design valid for use only with MII connectors. This design Is based only upon parameters shown, and Is for an Individual buliding component, not ��- a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall bullding design, Bracing Indicated is o prevent buckling of Individual Muss web and/or chord members only. Additional temporary and permanent bracing WOW Is always required for stability, and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication. storage, deft ery, erection and bracing of busses end hum systems, seeANSVIPIT CualMMyy Cdleda, DSSd9 and SCSI Building Component 6904 Parke East Blvd, Safety Infoanallonoveilabie from Truss Plate Inst Me. 218 N. Lee Street, Suite 312. Neaontlrlo. VA 22314, Tampa, FL 33610 Job Truss Truss Type O1Y Ply THECOTTAGE ' T78622023 M11455 J5 JACK -OPEN 8 1 Job Reference (optional) warmers I was, mc., ran tierce, rL 3x4 = aye ,. ID:AXCVr6ubfdeoJ5ziCdy W PDyLFMw-UZXSA?DgUeg2al W GPC7 vovajgxUXsTjz6aCgj_yKK7? Scale =1:12.7 Ica . l LOADING (psf) SPACING- 2-0-0 CSI. DEFL. In (loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.35 Vert(LL) 0.13 4-7 >455 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.91 Ved(CT) -0.05 4-7 >999 240 BCLL 0.0 ' Rep Stress ]nor YES WB 0.00 Horz(CT) -0.00 3 WE rda BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 171b FT 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD 2x4 SP No.3 BOT CHORD REACTIONS. (lb/size) 3=119/Mechanical, 2=242/0-8-0, 4=59/Mechanical Max Horz 2=123(LC 12) Max Uplift 3— 126(LC 12), 2=-278(LC 12), 4= 87(LC 12) Max Gray 3=119(LC 1), 2=242(LC 1), 4=84(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown Structural wood sheathing directly applied or 5-0-0 oc pudins. Rigid ceiling directly applied. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15h; B=45ft; L=24ft; eave=oft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exte ior(2) -1-0-0 to 2-M, Interior(1) 2-0-0 to 4-11-4 zone; porch left and right exposed;C-C for members and forces 8 MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom'. chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) 4 except at=lb) 3=126, 2=278. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cad 6634 8934 Parke East Blvd. Tampa FL 33610 Data: November 11,2019 Q MINING. Verlfydesignparamefersand HEAD NOTES ON TN/SANDINCLUDED MREKHEFERANCEPAGEMMM rev. 1ND14p15BEFOREUSE. Design valid for use only with MnekO connectors. This design Is based only upon parameters shown, and Is for on Individual building component, not a truss system. Before use, the bulltling designer must verify the appllcablllty of design parameters and properly Incorporate this design Into the overall is buckling buss web chord members only. Additional temporary and permanent bracing building design. Bracing Indicated to prevent oflnd'Ividuol and/or 6 always requited for slabllily, and to prevent collapse vAM possible personal Injury and property damage. For general guldonc s regarding the fobacalion, storage, delivery, erection and bracing of trusses and truss systems. seeANSI/[PII Cua1Nv Criteria, DSM9 and SCSI Building Component MiTek' 69N Parke East arm. Salefy Nlormvlbnwaloble from Truss Plate Institute. 218 N. Lee Sheet. Suite 312 Alexandria. VA 22 14. Tampa, FL 33610 Jab Truss Truss Type Cry Ply COTTAGET78622024 M11455 J7 JACK -OPEN 20 1b FE Reference (optional) UnamDers I cuss, Inc., Fan Ylerce, FL Udzu a Ucl zB z01 B MI l ex Industries, Inc. Mon Nov 11 U/:LB:Jb 2U18 Page 1 ID:AXCVr6ubfdeoJ5ziCdyW PDyLFMw-yl5TNLES EyyvBv4TvYBK77slLpRbwz6LExOFRyKK7_ -1-0-0 7-0-0 1.0.0 I 7-0-0 Scale: 3/4'=1- 3x4 = Plate Offsets (X.Y)— 12:0-1-14 Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (lac) .Vciefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.47 Vert(LL) -0.10 4-7 >857 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.99 Vert(CT) -0.21 4-7 >388 240 BCLL 0.0 ' Rep Stress Incr YES W B 0.00 HOt2(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MP Wind(LL) 0.18 4-7 >469 240 Weight: 23111 FT=20% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 3=170/Mechanical, 2=31510-8-0, 4=83/Mechanical Max Horz 2=161(LC 12) Max Uplift 3=-156(LC 12). 2=-21 O(LC 12), 4=-9(LC 12) Max Gmv 3=170(LC 1), 2=315(LC 1), 4=120(LC 3) FORCES. (Ib) - Max. CompJMax. Ten. -All forces 260 (lb) or less except when shown. BRACING - TOP. CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOTCHORD Rigid ceiling directly applied. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) -1-0-0 to 2-", Interior(l) 2-0-0 to 6-11-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 last bottom chord live load nonconcunent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift at joint(s) 4 except Qt=1b) 3=156, 2=210. Thomas A. Aftsmi PE No.39380 MiTek USA, Inc. FL Cent 6834 6904 Parke East Blvd. Tampa FL 33610 Dale: November 11,2019 ,&WARNING-Vedrydeslgnperamatweend READ NOTES ON THIS AND INCLUDED MREKNEFEBANCEPAGEMIF7473mm lNaYf016BEFOBE USE Design valid for use only wain MBekO connectors. This design Is based only upon parameters shown and b for on Individual building component, not ��- a truss system. Before use, the building designer must verity the applicability of design parameters and property Incorporate this design Into Me overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Add renal temporary and permanent bracing MiTek' is always rewired far stability end to prevent callopse with possible personal Injury and property damage. For general guidance regarding me fabrication, storage, delivery, erection and bracing of busses and truss systems, seeANSVTRI Cu,rryy Criteria, D5Bd9 and BCSI Building Component 6904 Parke East BNU. Safety NlormalbNvollable from Truss Plate Institute, 218 N. Lee Sheet. Suite 312, Alexandra¢ VA 22314. Tampa, FL 33610 I Job Tess Truss Type y Ply ' T78622025 M11455 J7P �Qt JACK -OPEN 4 1 �THECOTTAGE Job Reference (optional) unamoers I was, mc., ran rleroe, rL k71-� 0amaval ce mre run eer,uu ESEyyra. ry NLyFbiA6LExOFRyKK7_ - rayo O:AXCVr6ubfdeoJ5ziCdyW PDyLFMw-y15TNLSEyyvBv4TrvV8K77 Scale: 314'=1' Plate Offsets (X.Y)-- f2:0-0-2 0-0-01 LOADING (pst) SPACING- 2-0-0 CSI. DEFL in (roc) Vdefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.41 Verl 0.22 6-9 >376 240 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.43 Ven(CT) -0.12 6-9 >721 240 BCLL 0.0 ' Rep Stress Mor YES WB 0.24 HOrz(CT) -0.00 5 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MP Weight: 28 to FT=20% LUMBER - TOP CHORD 2x4 SP M 30 SOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 4=54/Mechanica1, 2=315/0.8-0, 5=199/MechanimI Max Horz 2=161(LC 12) Max Uplift 4=-50(LC 12), 2=-353(LC 12), 5=-256(LC 12) Max Grav 4=60(LC M. 2=315(LC 1).5=199(LC 1) FORCES. Ilia) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-335/554 BOT CHORD 2-6=-741/316 WEBS 3-6=349/819 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOT CHORD Rigid ceiling direcdyapplied or7-1-11 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ff; L=24ff; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) -1-M to 2-0-0. Interior(1) 2-0-0 to 6-11-4 zone; porch left and Fight exposed;C-C for members and forces R MW FRS for reactions shown; Lumber DOL=1.60 plate gdp DOL=1.60 2) This truss has been designed fora 10.0 pal bottom chord live load nonconcunent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer togirder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of Moss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 2=353,5=256. Thomas A Albani PE No.39380 31iTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: November 11,2019 Q WARNWG- Verdydezlenparemetexaend Rf54ON0TE50NMSMDWCLUOEG4IREKRPFERANCEPAGEM 74M., 70=015OU01 USfl Design valid far use only with Mgei, connectom fits design Is booed only upon parameters shown, and IS for On hdMdual building component not a russ system. Before use, the budding designer must veMy the applicability of design parameters and properly hCOrparate fink design into the overall bustling design. Bracing lndIcafed is to prevent buck gof individual tnss web and/or chord members only. Addiflonol temporary and permanent brodng MiTek' Is always required for stablity and to prevent conopse with possble personal injury and property damage. For general guldonce regarding ire fabriccfon, storage, delivery. erection and bracing of trusses and hrm systems, seeANSVTPII Cually Caloric, 1336d9 and SCSI Building Component 6904 Parke East Bind. Safety InformalbnovoloNe from Two Nate ImMure. 218 N. Lee Street Suite 312, Aloxandda, VA 22314. Tampa, FL M610 Job Truss Truss Type. OtY Ply 'T18622026 M11455 KJ7 DIAGONAL HIP GIRDER 4 1ob [HECOTTAGE Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.320 s Oct 292019 MiTek Industries, Inc. Mon Nov 11 07:29:37 2019 Pagel IO:AXCVr6ubfdeoJ54CdyW PDyLFMw-ueD EoOFmZDdRCEr5KacPYCF79gc31LPoYOUJJyKK6y Scale = 1:21.2 3x4 = zxo it 5 6x8 = 6-8-12 3-1-5 LOADING (PSO . SPACING- 2-0-0 CS]. DEFL in (too) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TO 0.28 Vert(LL) 0.14 7-10 >820 240 MT20 244/190 TOOL 7.0 Lumber DOL 1.25 BC 0.31 Vert(CT) -0.11 7-10 >999 240 BOLL 0.0 - Rep Stress Incr NO WB 0.33 Horz(CT) -0.01 5 n/a rJa ' BCDL 10.0 Code FBC2017/rPI2014 Matdx-MS Weight: 38 lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 cc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or7-2-13 oc bracing.. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 4=3alMechanical, 2=501/0-10-15, 5=435/Mechanical Max Harz 2=161(LC 8) Max Uplift 4=39(LC 8), 2=-574(LC 8). 5=-521(LC 8) FORCES. (lb) - Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-866/902 BOT CHORD 2-7— 95W823, 6-7=-958/823 WEBS 3-7=359/323,3-6=-949/1105 NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=411; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed fare 10.0 psf bottom chord live load nonconcurent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girders) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joints) 4 except Ut=lb) 2=574,5=521. 6) Hangers) or other connection device(s) shall be provided sufficient to support Concentrated load(s) 38 to down and 80lb up at 4-4-0, 38 lb down and 801b up at 4-4-0. and 67 Ib down and 149 lb up at 7-1-15, and 67 lb down and 1491b up at 7-1-15 on top chord, and 67 Ito down and 3 Ito up at 1.6-1, 6716 down and 3 lb up at 1-0-1, 21 Ito down and 4lb up at 4-4-0, 21 Ib down and 4Ib up at 4-4-0, and 36 Ito down and 441b up at 7-1-15, and 36lb down and 441b up at 7-1-15 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-54, 5-8=-20 Concentrated Loads (lb) Vert: 11=3(F— 1, B— 1) 12=84(F=-42, B=-42) 13=-7(F=-3, B=-3) 14=-20(F=-10, B=-10) 15=-61(F=30, B=30) Thomas A. Alban! PE No.39380 M!Tek USA, Inc. FL Cert6634 6904 Parks East Blvd. Tampa FL 33610 Date: November 11,2019 O WARNING- V dfydesign parsmelersen✓READ NOTES ON THIS AND INCLUDED MNEKREFERANCEPAGEMa7M.a .. iWDS2015REFORE USE. Design valid for use oNywith MirelolD connectors. Mis cosign Is based only upon parametersshown and star on hcMduol building component, not ��- a truss system. Before use, Me budding designer must verify me cpplicobnity of design parometers and properly Incorporate this design Into the overall building design. Bracing indkaled is to prevent bucWhg of individual truss web and/or Chad members only. Additional temporcry and permanent bracing MiTek- Is always required fa UoWly anal to prevent collapse with "bie personal Injury and Wopeny damage. For general guidance regarding the fabrication. stooge. delivery. erection anal bracing of busses and truss systems. seeANSUIPII Au CrI DS849 and BCSI Building Component Safety bdcrrmalbrwWcba from Truss Rote InsilMe, 218 N. Lee Street, Suthe 312, Alexandria. VA 22314. 6904 Parke East Blvd. Tampa, FL 33610 Symbols PLATE LOCATION AND ORIENTATION 13 74 Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0 �fldr For 4 x 2 orientation, locate plates 0-1 from outside edge of truss. This symbol indicates the required direction of slots in connector plates. Plate location details available in MTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate width measured perpendicular 4 x 4 to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION own and/or by text In by symbol section of th by Text in The bracing section of the output. Use T or I bracing If indicated. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only, Industry Standards: ANSI/TPII: National Design Specification for Metal Plate Connected Wood Truss Construction, DSB-89: Design Standard for Bracing. SCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses, Numbering System I 6-4-8 I dimensions shown Inffsixteenths t scale) III (Drawings not o scale) 2 3 TOP CHORDS JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERSAETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR-131 1, ESR-1352, ESR1988 ER-3907, ESR-236Z ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSIfrPI 1 section 6.3 These truss designs rely on lumber values established by others. 2012 MiTek® All Rights Reserved mm W1 Jo MiTek® MITek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015 A General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal orX-bracing. Is always required. See BCSI. 2. Truss bracing must be designed by on engineer. For wide truss spacing, Individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on Inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor. property owner and all other Interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/1PI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19%at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber Is a non-structural consideration and Is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions Indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and In all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing Indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling Is Installed. unless otherwise noted. 16, Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless Indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone Is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI I Quality Critero.