HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT
Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE
�' �1
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Zf
, Permit Number:
Owner: WYNNE BUILDING CORP.
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From .Plans)
9. Wall Types(1718.3 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1155.40 112
b. Concrete Block- Int Insul, Adjacent
•R=11.0 282.92 ft2
3. Number of units, if multiple family
1
c. Frame - Wood, Adjacent
R=11.0 240.00 ft2
4. Number of Bedrooms
1
d. other (see details)
R= 40.00 ft2
5. is this a worst case?
Yes
10. Ceiling Types ,(1336.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1306.00 ft2
6. Conditioned floor area above grade (ft2)
1306
b. Knee Wall (Vented)
R=19.0 30.60 ft2
Conditioned floor area below grade (ft2)
0
c. N/A
R= ft2
1.1. Ducts
R ft2
7. Windows(128.9 sqft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 120
a. U-Factor. Sgl, U=1.02
76.04 ft2
SHGC: SHGC=0.29
b. U-Factor. Sgl, U=1:03
40.00 ft2
12. Cooling systems
kBlu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
29.0SEER:14.00
c. U-Factor: Sgl, U=1.02
12.85 112
SHGC: SHGC=0.26
13. Healing systems
kBtulhr Efficiency
d. U-Factor: NIA
ft2
a. Electric Heat Pump
27.0 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth:
4.701 ft.
Area Weighted Average SHGC:
0.281
14. Hot water systems
8. Floor Types (1306.0 sgft.)
Insulation Area
a. Electric
Cap: 50 gallons
.
a. Slab -On -Grade Edge Insulation
R=0.0 1306.00 ft2
b. Conservation features
EF: 0.950
b. NIA
R= ft2
None
c. NIA
R= ft2
15. Credits
None
Glass/Floor Area: 0.099
Total Proposed Modified Loads:' 43.39
PASS
Total Baseline
Loads: 44.12
I hereby certify that the plans and specifications covered by
Review of the plans and
Of-10ES7A,
this calculation are in compliance with the Florida Energy
specifications covered by this
e p
A.l
Code.
calculation indicates compliance
= ?'�
with the Florida Energy Code.
° len
< xxr '�. O
PREPARED BY: O
��k�
Before construction is completed
r� o
DATE: 1-9-20
this building will be inspected for
compliance.with Section 553.908
y
I "q y
c
I hereby certify that this building, as designed ' in compliance
Florida Statutes..
`
with the Florida Energy
OWNER/AGI
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
REVIEWED FOR
CODE COMPLIANCE
1/8/2020 5:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Editiorb f) Lom '6 I MO U NTY Page 1 of 5
BOCC
FORM R405-2017 INPUT SUMMARY' CHECKLIST REPORT
PROJECT
Title: WYNNE BUIDLING-THE CO Bedrooms: 1
Address Type:
Street Address
Building Type. User Conditioned Area: 1306
Lot#
Owner Name: WYNNE BUILDING CORP. Total Stories: 1
Block/Subdivision:
# of Units: 1 Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING CORP. Rotate Angle: 180
Street:
THE COTTAGE
Permit Office: ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie
Jurisdiction: Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1306 10576.2
SPACES
Number Name Area Volume IGtchen Occupants
Bedrooms
InfilID Finished Cooled
Healed
1 MASTER BEDROO 234 1895.4 No 0
1
1 Yes
Yes
Yes
2 DEN 144 1166.4 No 0
1 Yes
Yes
Yes
3 SINK AREA 42 340.2 No 0
1 Yes
Yes
-Yes
4 CLOSET 63 510.3 No 0
1 No
Yes
Yes
5 GREAT ROOM 452 3661.2 No 2
1 Yes
Yes
Yes
6 MASTER BATH 50 405 No 0
1 Yes
Yes
Yes
7 POWDER 25 202.5 No 0
1 No
Yes
Yes
8 KITCHEN 232. 1879.2 Yes 0
1 Yes
Yes
Yes
9 LAUNDRY 40 324 No 0
1 No
Yes
Yes
10 STORAGE 24 192 No 0
0
1 Yes
'Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio MASTER BEDRO 31 it .0
234 ft'
_
0 1
0
2Slab-On-Grade,Edge lnsulatio DEN 24 It 0
144 ft'
_
0 1
0
3Slab-On-Grade EdgeJnsulatio SINKARFA 7ft 0
42ft'
0 1
0
4 Slab -On -Grade Edge lnsulatio CLOSET 1 ft 0
63 ft'
____
0 1
0
5 Slab -On -Grade Edge lnsulatio GREAT ROOM 32 It 0
452 It'
_
0 1
0
6Slab-On-Grade Edge lnsulatio MASTER BATH 5 ft 0
50 ft'
_
0 1
0
7Slab-On-Grade Edge lnsulatio POWDER 1 ft '0
25 fN
0 1
0
1/8/2020 5:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
8 Slab -On -Grade Edge Insulatio KITCHEN 38 ft 0
232 ft'
0
1
0
9 Slab -On -Grade Edge Insulatio LAUNDRY t ft
0
40 ft2
_
0
1
0
10Slab-On-Grade Edge Insulatio STORAGE 21 ft
0
24 ft2
_
0
0
1
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pilch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Metal 1376 ft2
0 ft2
.Light
N
0.8
No 0.9
No 0
18.4
ATTIC
/
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1306 ft'
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) MASTER BEDRO
30
Blown
234 ft'
0.1
Wood
2
Under Attic (Vented) DEN
30
Blown
144 ft'
0.1
Wood
3
Under Attic (Vented) SINKAREA
30
Blown
42ft'
0.1
Wood
_
4
Under Attic (Vented) CLOSET
30
Blown
63-ft'
0.1
Wood
5
Under Attic (Vented) GREAT ROOM
30
Blown
452 ft'
0.1
Wood
6
Under Attic (Vented) MASTER BATH
30
Blown
50 ft2
0.1
Wood
7
Under Attic (Vented) POWDER
30
Blown.
25ft2
0.1
Wood
,
_
8
.Under Attic (Vented) KITCHEN
30
Blown
232 ft2
0.1
Wood
9
Under Attie (Vented) LAUNDRY
30
Blown
40ft2
0.1
Wood
_
10
Under Attic (Vented) STORAGE
30
Blown
24 ft'
0.11
Wood
11
Knee Wall (Vented) GREAT ROOM
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing .Solar
Below
0
_ 1
S=>N
Exterior Concrete Block -'Int InsNASTER BE
4.1 18
0 8
1
145.5 ft2
0
0
0:3
0
_ 2
W=>E
Exterior Concrete Block - Int Ins01ASTER BE
4.1 13
0 8
1
105.1 ft2
0
0
0.3
0
_ 3
N=>S
Exterior Concrete Block- Int Insul DEN
4.1 12
0 8
1
97.0 ft2
0
0
0.3
0
4
W=>E
Exterior Concrete Block. Int Insul DEN
4.1 12
0 8
1
97.0 ft2
0
0
0.3
0
_5
S=>N
Exterior Concrete Block- Int lnsuBINK AREA
4.1 7
0 8
1
56.6 ft2
0
0
0.3
0
_ 6
N=>S
Exterior Concrete Block - Int InsGREAT ROO
4.1 22
0 8
1
177.8 ft2
0
0
0.3
0
_ 7
W=>E
Exterior Concrete Block - Int Ins01REAT ROO
4.1 10
0 8
1
80.8 ft'
0
0
0.3
0
_ 8
S=>N
Exterior Concrete Block- Int InsiMASTER BA
4.1 5
0 8
1
40.4 ft2
0
0
0.3
0
_9
N=>S
Exterior Concrete Block- Int lnsulKITCHEN
4.1 17
0 8
1
137.4 ft2
0
0
0.3
0
10
E=>W
Exterior Concrete Block- Int InsulKITCHEN
4.1 16
0 8
1
129.3 ft2
0
0
0.3
0
11
S=>N
Exterior Concrete Block - Int InsulKITCHEN
4.1 5
0 8
1
40.4 ft'
0
0
0.3
0
1/8/2020 5:04 PM EneryyGauye®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT. SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Spam :Cavity Width
P
Height
, Sheathing Framing Solar
Below
o
_ 12 N=>S Garage Concrete Block- Int Insu1KITCHEN 11 35 8
13. N=>S Exterior Concrete Block- Int InsuSTORAGE 4,0999 6 8
14 N=>S Garage Concrete Block- Int InsuSTORAGE - 4.0999 5 8
15 N=>S Garage Frame -Wood MASTER BE 11 30 8
1 282.9 ft2
48.0 ft2
40:0 ft2
0 240.0 ft2
0 0 0.3
0. 0 0.3
0 0 0.3
0 0.23 0.3
0
'0
0
0
DOORS
# Omt Door Type
Space Storms
U-Value
Ft
Width Height
In R In
Area
1 E=>W Insulated
KITCHEN None
.32 3
6 8
20ft2
WINDOWS
Orientation shown Is the entered orientation => changed to Worst Case.
/ Wall
V # Ornt ID Frame Panes
'NFRC U-Factor SHGC Imp
Overhang
Area Depth Separation Int Shade
Screening
' 1 W=>E 2 Metal Low-E Single
2 W=>E 4, Metal Low-E Single
_ 3 N=>S 6 Metal Low-E Single
_ 4 W=>E 7 Metal Low-E Single
_ 5 S=>N 8 Metal Low-E Single
6 E=>W 10 Metal Low-E Single
Yes 1.02 0.29 N
Yes 1.02 0.29 N
Yes 1.02 0.29 N
Yes 1.03 0.27 N
Yes 1.02 0.29 N
Yes 1.02 0.26 N
32.4 112 1 It 5 in
18A ft' 1 It 5 in
18.4 ft2 1 ft 5 in
40.0 ft2 12 It 0In
6.9 ft2 1 ft 5In
12.8 ft2 1 It 5 in
1 ft 5 in None
1 ft 51n None
1 ft 5 in None
1 ft 5 in None
1 It 5 in None
1 ft 5 In None
None
None
None
None
None
None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wag Insulation
1 280 ft2 280 ft2 35 ft
8.1 R
11
INFILTRATION
# Scope Method -
SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000257
881.4 48.38 90.99 .0896
5
HEATING SYSTEM
# System Type
Subtype Speed Efficiency ' Capacity
Block
Ducts
_ 1 Electric Heat Pump/
Split Singl HSPF:8.2
27 kBtulhr
1
COOLING SYSTEM
JDucts
# System Type
Subtype Subtype Efficiency
Capacity Air Flow SHR Block
1 Central Unit/
Split Singl SEER: 14
29 kBtulhr
cfm. 0.8 1
1/812020 5:04 PM EnergyGauge® USA 6.0.02.(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHE6KLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.95
50 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # Company Name
System Model # Collector Model
# Area Volume
FEF
None None
ft'
DUCTS
/ —Supply—
---Return--
Air
CFM 25
CFM25
HVAC#
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic
6 120 ft'
Attic
45 ft'
Default: Leakage
Attic,,
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Cooling Jan Feb
Venting Jan Feb
jjXj] Mar
Mar
Apr
Apr
May
May
Jun 4Xjj Jul
Aug
Sep
jj jj Oct
Nov
Dec
H
[X]
Jun [ ] Jul
Aug
Sep
[X] Oct X.Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4
5 6
7
8
9 10
11
12
Cooling (WD) AM
78
78 78
78
78 78
78
78
78 78
78
.78
PM
78
78 78
78
78 78
78
78
78 78
78
78
Cooling(WEH) AM'
78
78 78
78
78 78
78
78
78 78
78
78
PM
78
78 78
78
78 78
78
78
78 78
78
78
Heating (WD) PM
68
68 68
68
68 68
68
68
68 68
68
68
Heating (WEH) AM
68
68 68
68
68 68
68
68
68 68
68
68
PM
68
68 68
68
68 68
68
68
68 68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(B Ibs/sq.ft.
0 ft'
0 ft
0.3
MASTER BEDR00
Defaull(8lbs/sq.ft.
ft'
ft
0.3
DEN
Default(8lbs/sq.ft.
ft'
ft
0.3
SINKARFA
Default(8 lbslsq.fL
ft'
ft
0.3
CLOSET
Default(8 lbs/sq.ft.
ft'
ft
-0.3
GREAT ROOM
Default(8 lbs/sq.ft.
ft'
ft
0.3
MASTER BATH
Default(8 lbslsq.ft.
ft'
ft
0.3
POWDER
Default(81bs/sq.ft.
ft'
ft
0.3
KITCHEN
_
Default(8 lbs/sq.ft.
ft'
ft
0.3
LAUNDRY
. Default 8 lbsls .ft.
-
0 ft'
- 0 ft .
0.3
-
STORAGE
1/8/2020 6:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FIdRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE Permit Office: ST.LUCIE000NTY
City, State, Zip: FT. PIERCE, FL, - Permit Number:
Y
U
Owner: WYNNE BUILDING CORP. Jurisdiction:
_
Design Location: FL, Fort Pierce
o
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be Installed in the buildingenvelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier In dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air bardershall be sealed.
shall be aligned with the air barrier.
.Access. openings, drop down stairs or knee wall doors to
unconditioned attics aces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame wails
The junction. of the top plate and the too of exterior walls shall be
shall be insulated,by completely filling the cavity
'
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per Inch minimum.
Exterior thermal envelope insulation for framed
walls shall be Installed'In substantial contact and
continuous alignment with the air barrier.
Windom, skylights
The space between Wndow/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framingcavity insulation shall be Installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking,, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous Insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor Insulation, insulation
a Class I vapor retarder with overlapping joints taped.
'shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
,
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation: that on
•
Installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and condifioned'spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures Installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and Wring
Batt insulation shall be cut neatly to fit around wiring
and plumbing In exterior walls, or Insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier Installed at exterior walls adjacent to showers and
Exterior wallsadjacent to showers and tubs shall
on exterior wail
tubs shall separate them from the showers and tuffs.
be insulated.
Electdcal/phone box or
The air barder.shall be Installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be Installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall. ,
Concealed
When required to be sealed, concealed fire sprinklers.shall only be
d
sprinklers
sealed in•a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire snrinkler comaUlates and walls or ceilings I
a. In addition, inspection of logwalls snail be in accordance with the provisions of ]CC-400.
1/8/2020 5:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017FBC 6th Edition.(2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & Insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU.location
Attic
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 1
13. Cooling system: Capacity
29.0
a) Split system SEER
14.0
5. Is this a worst case? (yes/no)
5. Yes
b) Single package SEER
c) Ground./water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1306
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(welghted average) 7a. 1.023
b) Solar Heat Gain Coefficient'(SHGC) 7b. 0.281
c) Area 7c. 128.9
8. Skylights
a) U-factor.(weighted average) Be. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b). Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
10131. 11.0
10B2. varies
14. Heating system: Capacity 27.0
a) Split system heat pump HSPF . 8.2
b) Single package heat pump HSPF
c) Electric resistance COP
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.95
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
f) Heat recovery unit HeatReO/o
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a. 30.0 b) Cross ventilation No
11b. c) Whole house fan No
11c. 19.0 d) Multizone cooling credit
11d. No e) Multizone heating credit
f) Programmable thermostat No
`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
savingfeatures which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features. C/
Builder Signature: Date:
Address of New Home: THE COTTAGE X City/FL Zip: FT. PIERCE. Fl-
1/8/2020 5:04:49 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1