HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT
Builder Name: WYNNE BUILDING CORP.
THE CERCEGFL, ST. LUCIE COUNTY
`
S ('D
CityStreeState, Zip: Fr PIt:
l Penn t Nu ber;
Owner: WYNNE BUILDING CORP. C,%`
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(1718.3 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1155.40 ft2
b. Concrete Block -.Int Insul, Adjacent
R=11.0 282.92 ft2
3. Number of units, if multiple family 1
c. Frame - Wood, Adjacent
R=11.0 240.00 ft'
4. Number of Bedrooms 1
d, other (see details)
R= 40.00 ft'
5. Is this a worst case? Yes
10. Ceiling Types (1336.0 still.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1306.00 ft2
6. Conditioned floor area above grade (ft� 1306
b. Knee Wall (Vented)
R=19.0 30.00 112
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft'
1.1. Ducts
R ft'
7. Windows(128.9 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 120
a. U-Factor: Sgl, U=1.02 76.04 ft2
SHGC: SHGC=0.29
-
b. U-Factor. Sgl, U=1.03 40.00 ft2
12. Cooling systems
kBlu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
29.0 SEER:14.00
c. U-Factor: Sgl, U=1.02 12.85 ft2
SHGC: SHGC=0.26
13. Heating systems
kBtulhr Efficiency
d. U-Factor. WA ft2
a. Electric Heat Pump
27.0 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 4.701 ft.
Area Weighted Average SHGC: 0.281
14. Hot water systems
8. Floor Types (1306.0 sqft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1308.00 ft'
b. Conservation features
EF: 0.950
b. N/A R= ft2
None
c. NIA R= ft'
15. Credits
None
Glass/Floor Area: 0.099! Total Proposed Modified Loads: 43.39
PASS
Total Baseline Loads: 44.12
1 hereby certify that the plans and specifications covered by
Review of the plans and
D� T1iRST.gTe
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
n�
with the Florida Energy Code.
enna• <" Yr O
PREPARED BY: 1y 100
Before construction is completed
a '
DATE: 1-9-20
this building will be inspected for
compliance with Section 553.908
hereby certify that this building, as designed, is in compliance
Florida Statutes.
!,),
with the Florida Energy Code.
OWNER/AG NI
BUILDING OFFICIAL:
DATE: \
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R4024.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00'ACH50 (R402.4.1.2).
1/8/2020 5:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE BUIDLING-THE CO Bedrooms: 1
Address Type:
Street Address
Building Type: User Conditioned Area: 1306
Lot #
Owner Name: WYNNE BUILDING CORP. Total Stories: 1
Block/Subdivision:
# of Units: 1 Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING CORP. Rotate Angle., 180
Street:
THECOTTAGE
Permit Once: ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie
Jurisdiction: Whole House Fan: No
City, State, Zip:
FT. -PIERCE ,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
_ / Design Temp
Int Design Temp Heating
Design DallyTemp
V Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1306 10576.2
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 MASTER BEDROO 234 1895.4 No 0
1
1 Yes
Yes
Yes
2 DEN 144 1166.4 No 0
1 Yes
Yes
Yes
3 SINKAREA 42 340.2 No 0
1 Yes -
Yes
Yes
4 CLOSET 63 510.3 No 0
1 No
Yes
Yes
5- GREAT ROOM 452 3661.2 No 2
1 Yes
Yes
Yes
6 MASTER BATH 50 405 No 0
1 Yes
Yes
Yes
7 POWDER 25 202.5 No 0
1 No
Yes
Yes
8 KITCHEN 232 1879.2 Yes 0
1 Yes
Yes
Yes
9 LAUNDRY 40 324 No 0
1 No
Yes
Yes
10 STORAGE 24 192 No 0
0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio MASTER BEDRO 31 ft -0.
234 ft2
0 1
0
2 Slab -On -Grade Edge Insulatio DEN 24 ft 0
144 ft2
—
0 1
0
3SIab-On-Grade Edge Insulatio SINK AREA 7 ft 0
42 ft2
—
0 1
0
4SIab-On-Grade Edge Insulatio CLOSET t ft 0
63 ft2
—
0 1
0
5SIab-On-Grade Edge Insulatio GREAT ROOM '32ft 0
452 ft2
_
0 1
0
6 Slab -On -Grade Edge Insulatio MASTER BATH sit 0
50 ft2
_
0 1
0
7SIab-On-Grade Edge Insulatio POWDER 1 ft 0
25 ft2
r
0 1
0
1/8/2020 5:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio ' KITCHEN 38It 0
232 ft'
_
0
1
0
9 Slab -On -Grade Edge Insulatio LAUNDRY 1 ft
0
40 ft'
0
1
0
10SIab-On-Grade Edge Insulatio STORAGE 21 It 0
24 W
_
0
0
1
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emift
Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Metal 1376 ft2
Oft'
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1306 ft'
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) MASTER BEDRO 30
Blown
234 ft2
0.1
Wood
_
2
Under Attic (Vented) DEN
30
Blown
144 ft'
0.1
Wood
_
3
Under Attic (Vented) SINKAREA
30
Blown
42ft'
0.1
Wood
_
4
Under Attic (Vented) CLOSET
30
Blown
63 IF
0.1
Wood
5
Under Attic (Vented) GREAT ROOM
30
Blown
452 ft'
0.1
Wood
_
6
Under Attic (Vented) MASTER BATH
30
Blown
50 W
0.1
Wood
7
Under Attic (Vented) POWDER
30
Blown
25 ft'
0.1
Wood
8
Under Attic (Vented) KITCHEN
30
Blown
232 ft'
0.1
Wood
_
9
Under Attic (Vented) LAUNDRY
30
Blown
40ft'
0.1
Wood
_
10
Under Attic (Vented) STORAGE
30
Blown
24 ft'
0.11
Wood
11
Knee Wall (Vented) GREAT ROOM
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar
Below
_ 1
S=>N
Exterior Concrete Block- Int InsOEASTER BE
4.1 18
0 8
1
145.5 fl'
0
0
0.3
0
_ 2
W=>E
Exterior Concrete Block- Int InsWASTER BE
4.1 13
0 8
1
105.1 ft'
0
0
0.3
0
_ 3
N=>S
Exterior Concrete Block - Int Insul DEN
4.1 12
0 8
1
97.0 R'
0
0
0.3
0
_ 4
W=>E
Exterior Concrete Block- Int Insul DEN
4.1 12
0 8
1
97.0 ft'
0
0
0.3
0
_ 5
S=>N
Exterior Concrete Block- Int InstSINK AREA
4.1 7
0 8
1
56.6 ft'
0
0
0.3
0
_ 6
N=>S
Exterior Concrete Block- Int InsGREAT ROO
4.1 22
0 8
1
177.8 ft'
0
0
0.3
0
_ 7
W=>E
Exterior Concrete Block - Int InsGREAT ROO
4.1 10
0 8
1
80.8 ft'
0
0
0.3
0
_ 8
S=>N
Exterior Concrete Block- Int Ins01ASTER BA
4.1 5
0 8
1
40.4 ft'
0
0
0.3
0
_ 9
N=>S
Exterior Concrete Black- Int InsuIKITCHEN
4.1 17
0 8
1
137.4 ft'
0
0
0.3
0
_ 10
E=>W
Exterior Concrete Block- Int InsuIKITCHEN
4.1 16
0 8
1
129.3 ft'
0
0
0.3
0
11
S=>N
Exterior Concrete Block- Int Insu]KITCHEN
4.1 5
0 8
1
40.4 ft2
0
0
0.3
0
1/8/2020 5:04 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space ,Cavity Width
Height
Sheathing Framing Solar Below
12 N=>S Garage Concrete Block - Int InsuIKITCHEN 11 35 8
13 N=>S Exterior Concrete Block- Int InsuBTORAGE 4.0999 6 8
_ 14 N=>S Garage Concrete Block- Int InsuBTORAGE 4.0999 5 8
15 N=>S Garage Frame - Wood MASTER BE 11 30 8
1 282.9 ft'
48.0 ft
40.0 ft'
0 240.0 ft'
0
0
0
0
0 0.3
0 0.3
0 0.3
0.23 0.3
0
0
0
0
DOORS
# Omt
Door Type Space Storms
U-Value Width
Ft In
Height
Ft In
Area
1 E=>W
Insulated KITCHEN None
.32 3
6 8
20 fN
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
# Omt ID Frame
Panes NFRC U-Factor SHGC Imp
Overhang
Area Depth Separation
Int Shade
Screening
_ 1 W=>E 2 Metal
_ 2 W=>E 4 Metal
3 N=>S 6 Metal
4 W=>E 7 Metal
5 S=>N 8 Metal
6 E=>W 10 Metal
Low-E Single Yes 1.02 0.29 N
Low-E Single Yes 1.02 0.29 N
Low-E Single Yes 1.02 0.29 N
Low-E Single Yes 1.03 0.27 N
Low-E Single Yes 1.02 0.29 N
Low-E Single Yes 1.02 0.26 N
32.41t' 1 ft 5 In
18.4 ft' 1 ft 5 in
18.4 ft' 1 ft 5 in
40.0 R' 12 it 0 in
6.9 ft' 1 ft 5 in
12.8 IF 1 ft 5 in
1 ft 5 in
1 ft 5 in
1 ft 5 in
1 It 5 in
1 ft 5 in
1 ft 5 in
None
None
None
None
None
None
None
None
None
None
None
None
GARAGE
# Floor Area
Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 280 ft'
280 ft' 35 ft
8.1 It
11
INFILTRATION
# Scope Method
SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000257 881A 48.38 90.99 .0896
5
HEATING SYSTEM
# System Type
Subtype Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split Singl HSPF:8.2
27 kBlu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype Subtype Efficiency
Capacity Afr Flow SHR Block
Ducts
1 Central Unit/
Split Sing] SEER: 14
29 kBtulhr
cfm
0.8 1
sys#1
1/812020 5:04 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.95
50 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model
# Area Volume
FEF
None None
ft
DUCTS
_ / —Supply—
—Return'—
Air
CFM 25
CFM25
HVAC#
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic
6 120 ft'
Attic
45 ft'
Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programablre T]hermostar[t:�]N
Crreiling Fans:
Heating Jan Feb
r[Xj,]
H Mar
[ ]
L a Apr
I May
rl JMay un Jul
Aug
Sep
[. ]
1.1 Oct
Nov
r�7(,�
Venting [[[[ IIII Jan [[[ III Feb
l l l l
[[[[�XXX]))) Mar
lxl
[
Jun Jul
[[[ ]]] Aug
]]] Sep
lxl
[ ] Dec
Thermostat Schedule: HERS 2006 Reference
I
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78 78
78
78
78 78
78
78
PM
78
78
78
78
78 78
78
78
7878
78
78
Cooling (%,WH) AM
78
78
78
78
78 78
78
78
78 78
78
78
PM
78
78
78
78
78 78
78
78
78 78
78
78
Heating (WD) AM
68
68
fib
68
68 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
68
68
Heating (WEH) AM
68
68
68
68
68 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Defaull(81bs/sq.fL
0 ft2
0 ft
0.3
MASTER BEDROO
Defaull(8lbs/sq.ft.
ft'
ft
0.3
DEN
Default(8lbslsq.ft.
ft'
ft
0.3
SINKARFA
Default(8 lbslsq.ft.
ft'
ft
0.3
CLOSET
Default(8 lbs/sq.ft.
ft'
ft
0.3
GREAT ROOM
Default(81bs/sq.fL
fl'
ft
0.3
MASTER BATH
Default(8 lbs/sq.ft.
ft'
ft
0.3
POWDER
Default(81bs/sq.fL
ft'
ft
0.3
KITCHEN
Default(8lbslsq.ft.
ft'
ft
0.3
LAUNDRY
Default 8lbs/s .fL
Oft'.
Oft
0.3
STORAGE
1/8/2020 5:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, - Permit Number.
cYi
Owner. WYNNE BUILDING CORP. Jurisdiction:
_
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier,
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The Insulation Ina dropped ceiling/soffit
/soffit
the insulation and any gaps in the air barier,shall be sealed.
shall be aligned withth ai the air bander.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per Inch minimum.
Exterior thermal envelope Insulation for framed
walls shall be Installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shag be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation Installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space wails
Exposed earth In unvenled crawl spaces shall be covered with
Where provided instead of floor insulation, Insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spar
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures Installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt Insulation shall be cut neatly to fit around wiring
and plumbing in exterlorwalis, or Insulation that on
Installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electricallphone box or
The air barrier shall be Installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition, inspection or log wails snail bean accordance win me provisions or IUU-4uu.
1/812020 5:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy
Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 1
13. Cooling system: Capacity
29.0
a) Split system SEER
14.0
5. Is this a worst case? (yes/no)
5. Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1306
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor.(weighted average)
7a. 1.023
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.281
14. Heating system: Capacity
27.0
c) Area
7c. 128.9
a) Split system heat pump HSPF
8.2
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
_
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
t0A2. 4.1
10131. 11.0
10132. varies
11a. 30.0
11 b.
11c. 19.0
11d. No
15. Water heating system
a) Electric resistance EF 0.95
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
1) Heat recovery unit HeatRec%
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
b) Cross ventilation No
c) Whole house fan No
d) Multizone cooling credit
e) Multizone heating credit
f) Programmable thermostat No
`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in. this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: s Date:
Address of New Home: THE COTTAGE Sto fi?�oi c�:Sh City/FL Zip: FT. PIERCE. FL
1/8/2020 5:04:49 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1