Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-13 16:17:26 Right-Suite® Universal 2019 19.0.19 RSU27054 Page 1 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: N 629Job:Load Short Form Oct 29, 2019Date:House Vicki Lynne BarenbergBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Dunn, Groza Builders, IncFor: 0 Slash Pine Trail, Fort Pierce, FL 34951 Design Information InfiltrationClgHtg SimplifiedMethod9041Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1529Design TD (°F) L-Daily range 5030Inside humidity (%) 572Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade LENNOX Model Cond 14ACXS030-230A** AHRI ref Coil CBA27UHE-030-230*++TDR AHRI ref 10259390 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW6.9 Sensible cooling Btuh20020 Heating output Btuh23547 Latent cooling Btuh8580 Temperature rise °F22 Total cooling Btuh28600 Actual air flow cfm953 Actual air flow cfm953 Air flow factor cfm/Btuh0.043 Air flow factor cfm/Btuh0.047 Static pressure in H2O0.60 Static pressure in H2O0.60 Space thermostat Load sensible heat ratio 0.77 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Bed 3 174 2171 1319 94 62 Bath 2 54 634 278 27 13 Lin 8 0 0 0 0 Bed 2 159 2603 1780 113 83 Hall 30 0 0 0 0 Laundry 52 472 936 20 44 Kit/Nook 326 2854 5088 123 237 Great Room 408 4452 5891 193 275 M Lin 9 0 0 0 0 M Bath 132 2593 1398 112 65 Wtr Clst 26 607 230 26 11 Closet 21 0 0 0 0 WIC 42 645 240 28 11 Master Suite 337 4995 3271 216 153 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-13 16:17:26 Right-Suite® Universal 2019 19.0.19 RSU27054 Page 2 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: N House d 1777 22025 20430 953 953 Other equip loads 1522 808 Equip. @ 0.95 RSM 20261 Latent cooling 6407 TOTALS 1777 23547 26668 953 953 2020-May-13 16:17:26 Right-Suite® Universal 2019 19.0.19 RSU27054 Page 1 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: N 629Job:Building Analysis Oct 29, 2019Date:House Vicki Lynne BarenbergBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Dunn, Groza Builders, IncFor: 0 Slash Pine Trail, Fort Pierce, FL 34951 Design Conditions Location: CoolingHeatingIndoor:7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Other Ceilings Floors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 14.634272.2Walls 8.319439.0Glazing 0.3773.7Doors 12.028191.6Ceilings 22.853733.03.0Floors 13.431461.9Infiltration 22.35239Ducts 00Piping 00Humidification 6.51522Ventilation0Adjustments 100.023547Total Cooling Walls Glazing Other Ceilings Infiltration Ducts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 12.626671.7Walls 19.4411419.1Glazing 0.4783.7Doors 10.221721.2Ceilings 000Floors 4.18790.5Infiltration 27.85900Ducts 3.8808Ventilation 21.84620Internal gains 00Blower 0Adjustments 100.021238Total Latent Cooling Load = 6407 Btuh Overall U-value = 0.203 Btuh/ft²-°F Data entries checked. 2020-May-13 16:17:26 Right-Suite® Universal 2019 19.0.19 RSU27054 Page 1 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: N 629Job:Component Constructions Oct 29, 2019Date:House Vicki Lynne BarenbergBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Dunn, Groza Builders, IncFor: 0 Slash Pine Trail, Fort Pierce, FL 34951 Design Conditions Location: CoolingHeatingIndoor: 7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Blk Wall, Stucco Ext, R-9 Ext Bd Ins, 8" Thk, 1/2" DW 0.071411n 7071.728432.0510.0 491.72582.0510.00.07128ne 2691.723212.0510.00.071156e 471.72562.0510.00.07128se 6811.728132.0510.00.071396s 6161.727362.0510.00.071358w 23691.7228282.0510.00.0711378all Partitions Frm Wall, 1/2" DW Ext, R-11 Cav Ins, 1/2" DW Int Fnsh, 2"x4" Wood Frm, 16" OC STUD 2981.465992.9411.00.101204 Windows Impact: Impact; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 14.6 ft sep.); 6.67 ft head ht 1627.072008.7000.30023n Impact, OBSC: Impact, OBSC; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (2 ft window ht, 1 ft sep.); 6.67 ft head ht 287.07358.7000.3004n Impact: Impact; NFRC rated (SHGC=0.19); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 6.67 ft head ht 24216.01368.9900.31015ne 31520.21408.9900.31016e 63020.22808.9900.31031e 24615.31448.9900.31016se 1419.061408.9900.31016s 31520.21408.9900.31016w 188817.39828.9900.310109all Impact: Impact; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (1 ft window ht, 1 ft sep.); 6.67 ft head ht 238.80218.1200.2803s Impact: Impact; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 6.67 ft head ht 49421.52008.7000.30023w 2020-May-13 16:17:26 Right-Suite® Universal 2019 19.0.19 RSU27054 Page 2 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: N Impact: Impact; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (7 ft window ht, 8 ft sep.); 6.67 ft head ht 107425.64029.5700.33042w Impact, OBSC: Impact, OBSC; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (4 ft window ht, 1 ft sep.); 6.67 ft head ht 25821.51048.7000.30012w Doors DftDoor: Fbrgl 783.73773.697.00.12721e Ceilings R-20 Icynene: Attic, Shingle Roof, R-20 Spray Foam, 1/2" DW 21.00.4051777 21721.2228191.59 Floors On Grade, Tile Flr 00537328.700.989187 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-13 16:17:26 Right-Suite® Universal 2019 19.0.19 RSU27054 Page 1 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: N 629Job:Project Summary Oct 29, 2019Date:House Vicki Lynne BarenbergBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Dunn, Groza Builders, IncFor:0 Slash Pine Trail, Fort Pierce, FL 34951 Notes: Design Information St Lucie Co Intl, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F41 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F29 Design TD °F15Daily range L Relative humidity %50Moisture difference gr/lb57 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh16785 Structure Btuh14530 Ducts Btuh5239 Ducts Btuh5900Central vent (48 cfm) 1522 Btuh Central vent (48 cfm) Btuh808 Outside air Outside airHumidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh23547 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh20261 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh2808 Ducts Btuh1753Central vent (48 cfm) Btuh1846 CoolingHeating Outside air17771777Area (ft²) Equipment latent load Btuh6407 1558515585Volume (ft³)Air changes/hour 0.200.38 Equipment Total Load (Sen+Lat)Btuh26668 Equiv. AVF (cfm) 5299 Req. total capacity at 0.70 SHR ton2.4 Heating Equipment Summary Cooling Equipment Summary Make Make LennoxTrade Trade LENNOX Model Cond 14ACXS030-230A**AHRI ref Coil CBA27UHE-030-230*++TDR AHRI ref 10259390Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW6.9 Sensible cooling Btuh20020Heating output Btuh23547 Latent cooling Btuh8580 Temperature rise °F22 Total cooling Btuh28600Actual air flow cfm953 Actual air flow cfm953 Air flow factor cfm/Btuh0.043 Air flow factor cfm/Btuh0.047Static pressure in H2O0.60 Static pressure in H2O0.60 Space thermostat Load sensible heat ratio 0.77 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-13 16:17:26Right-Suite® Universal 2019 19.0.19 RSU27054 Page 1...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: N 629Job:Right-J® Worksheet Oct 29, 2019Date:House Vicki Lynne BarenbergBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name House Bed 3 2 Exposed wall 187.3 ft 15.0 ft 3 Room height 8.8 dft 8.0 heat/coolft 4 Room dimensions ft173.8x1.0 5 Room area 1776.8 ft²173.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nn 2.052.05 1.721.72 438 411 843 707 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.077.07 23 0 200 162 0 0 0 0 .GG Impact, OBSCImpact, OBSC 0.3000.300 nn 8.708.70 7.077.07 4 0 35 28 0 0 0 0 .WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nene 2.052.05 1.721.72 44 28 58 49 0 0 0 0 11 GG ImpactImpact 0.3100.310 nene 8.998.99 15.9715.97 15 0 136 242 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ee 2.052.05 1.721.72 224 156 321 269 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.1820.18 16 0 140 315 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.1820.18 31 0 280 630 0 0 0 0 DD DftDoorDftDoor 0.1270.127 ee 3.693.69 3.733.73 21 21 77 78 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 sese 2.052.05 1.721.72 44 28 56 47 0 0 0 0 GG ImpactImpact 0.3100.310 sese 8.998.99 15.3415.34 16 2 144 246 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ss 2.052.05 1.721.72 414 396 813 681 120 104 214 180 GG ImpactImpact 0.2800.280 ss 8.128.12 8.808.80 3 3 21 23 0 0 0 0 GG ImpactImpact 0.3100.310 ss 8.998.99 9.069.06 16 13 140 141 16 13 140 141 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ww 2.052.05 1.721.72 451 358 736 616 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.5021.50 23 0 200 494 0 0 0 0 GG ImpactImpact 0.3100.310 ww 8.998.99 20.1820.18 16 0 140 315 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 25.5725.57 42 0 402 1074 0 0 0 0 GG Impact, OBSCImpact, OBSC 0.3000.300 ww 8.708.70 21.5021.50 12 0 104 258 0 0 0 0 PP Frm Wall, 1/2" DW Ex 0.101Frm Wall, 1/2" DW Ex 0.101 --2.942.94 1.461.46 204 204 599 298 120 120 353 175 CC R-20 IcyneneR-20 Icynene 0.4050.405 --1.591.59 1.221.22 1777 1777 2819 2172 174 174 276 212 FF On Grade, Tile Flr 0.989On Grade, Tile Flr 0.989 --28.6828.68 0.000.00 1777 187 5373 0 174 15 430 0 6 c) AED excursion 186 -41 Envelope loss/gain 13640 9030 1413 667 12 a) Infiltration 3146 879 234 65 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 4 920 0 0 Appliances/other 3700 200 Subtotal (lines 6 to 13)16785 14530 1647 932 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 8 6 14 Subtotal 16785 14530 1654 938 15 Duct loads 31%41%5239 5900 31%41%516 381 Total room load 22025 20430 2171 1319 Air required (cfm)Air required (cfm)953 953 94 62 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-13 16:17:26Right-Suite® Universal 2019 19.0.19 RSU27054 Page 2...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: N 629Job:Right-J® Worksheet Oct 29, 2019Date:House Vicki Lynne BarenbergBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bath 2 Lin 2 Exposed wall 6.0 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft6.0x9.0 ft2.5x3.0 5 Room area 54.0 ft²7.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nn 2.052.05 1.721.72 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.077.07 0 0 0 0 0 0 0 0 .GG Impact, OBSCImpact, OBSC 0.3000.300 nn 8.708.70 7.077.07 0 0 0 0 0 0 0 0 .WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nene 2.052.05 1.721.72 0 0 0 0 0 0 0 0 11 GG ImpactImpact 0.3100.310 nene 8.998.99 15.9715.97 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ee 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 DD DftDoorDftDoor 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 sese 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 sese 8.998.99 15.3415.34 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ss 2.052.05 1.721.72 48 45 93 78 0 0 0 0 GG ImpactImpact 0.2800.280 ss 8.128.12 8.808.80 3 3 21 23 0 0 0 0 GG ImpactImpact 0.3100.310 ss 8.998.99 9.069.06 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ww 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ww 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 25.5725.57 0 0 0 0 0 0 0 0 GG Impact, OBSCImpact, OBSC 0.3000.300 ww 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" DW Ex 0.101Frm Wall, 1/2" DW Ex 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC R-20 IcyneneR-20 Icynene 0.4050.405 --1.591.59 1.221.22 54 54 86 66 8 8 12 9 FF On Grade, Tile Flr 0.989On Grade, Tile Flr 0.989 --28.6828.68 0.000.00 54 6 172 0 8 0 0 0 6 c) AED excursion -8 0 Envelope loss/gain 372 159 12 9 12 a) Infiltration 94 26 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)465 185 12 9 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 17 13 -12 -9 14 Subtotal 483 198 0 0 15 Duct loads 31%41%151 80 31%41%0 0 Total room load 634 278 0 0 Air required (cfm)Air required (cfm)27 13 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-13 16:17:26Right-Suite® Universal 2019 19.0.19 RSU27054 Page 3...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: N 629Job:Right-J® Worksheet Oct 29, 2019Date:House Vicki Lynne BarenbergBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bed 2 Hall 2 Exposed wall 26.5 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft158.8x1.0 ft8.5x3.5 5 Room area 158.8 ft²29.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nn 2.052.05 1.721.72 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.077.07 0 0 0 0 0 0 0 0 .GG Impact, OBSCImpact, OBSC 0.3000.300 nn 8.708.70 7.077.07 0 0 0 0 0 0 0 0 .WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nene 2.052.05 1.721.72 0 0 0 0 0 0 0 0 11 GG ImpactImpact 0.3100.310 nene 8.998.99 15.9715.97 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ee 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 DD DftDoorDftDoor 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 sese 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 sese 8.998.99 15.3415.34 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ss 2.052.05 1.721.72 112 112 230 193 0 0 0 0 GG ImpactImpact 0.2800.280 ss 8.128.12 8.808.80 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ss 8.998.99 9.069.06 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ww 2.052.05 1.721.72 100 84 173 145 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ww 8.998.99 20.1820.18 16 0 140 315 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 25.5725.57 0 0 0 0 0 0 0 0 GG Impact, OBSCImpact, OBSC 0.3000.300 ww 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" DW Ex 0.101Frm Wall, 1/2" DW Ex 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC R-20 IcyneneR-20 Icynene 0.4050.405 --1.591.59 1.221.22 159 159 252 194 30 30 47 36 FF On Grade, Tile Flr 0.989On Grade, Tile Flr 0.989 --28.6828.68 0.000.00 159 27 760 0 30 0 0 0 6 c) AED excursion 92 -2 Envelope loss/gain 1555 939 47 35 12 a) Infiltration 413 115 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 200 0 Subtotal (lines 6 to 13)1968 1254 47 35 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 15 11 -47 -35 14 Subtotal 1984 1266 0 0 15 Duct loads 31%41%619 514 31%41%0 0 Total room load 2603 1780 0 0 Air required (cfm)Air required (cfm)113 83 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-13 16:17:26Right-Suite® Universal 2019 19.0.19 RSU27054 Page 4...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: N 629Job:Right-J® Worksheet Oct 29, 2019Date:House Vicki Lynne BarenbergBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Laundry Kit/Nook 2 Exposed wall 0.5 ft 20.0 ft 3 Room height 8.0 heat/coolft 9.5 heat/coolft 4 Room dimensions ft6.5x8.0 ft326.0x1.0 5 Room area 52.0 ft²326.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nn 2.052.05 1.721.72 4 4 8 7 76 53 109 91 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.077.07 0 0 0 0 23 0 200 162 .GG Impact, OBSCImpact, OBSC 0.3000.300 nn 8.708.70 7.077.07 0 0 0 0 0 0 0 0 .WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nene 2.052.05 1.721.72 0 0 0 0 0 0 0 0 11 GG ImpactImpact 0.3100.310 nene 8.998.99 15.9715.97 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ee 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 DD DftDoorDftDoor 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 sese 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 sese 8.998.99 15.3415.34 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ss 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.2800.280 ss 8.128.12 8.808.80 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ss 8.998.99 9.069.06 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ww 2.052.05 1.721.72 0 0 0 0 114 91 187 157 GG ImpactImpact 0.3000.300 ww 8.708.70 21.5021.50 0 0 0 0 23 0 200 494 GG ImpactImpact 0.3100.310 ww 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 25.5725.57 0 0 0 0 0 0 0 0 GG Impact, OBSCImpact, OBSC 0.3000.300 ww 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" DW Ex 0.101Frm Wall, 1/2" DW Ex 0.101 --2.942.94 1.461.46 84 84 247 123 0 0 0 0 CC R-20 IcyneneR-20 Icynene 0.4050.405 --1.591.59 1.221.22 52 52 82 64 326 326 517 398 FF On Grade, Tile Flr 0.989On Grade, Tile Flr 0.989 --28.6828.68 0.000.00 52 1 14 0 326 20 574 0 6 c) AED excursion -29 39 Envelope loss/gain 352 164 1786 1341 12 a) Infiltration 8 2 370 103 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 2 460 Appliances/other 500 1700 Subtotal (lines 6 to 13)360 666 2156 3605 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 19 14 14 Subtotal 360 666 2175 3618 15 Duct loads 31%41%112 270 31%41%679 1469 Total room load 472 936 2854 5088 Air required (cfm)Air required (cfm)20 44 123 237 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-13 16:17:26Right-Suite® Universal 2019 19.0.19 RSU27054 Page 5...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: N 629Job:Right-J® Worksheet Oct 29, 2019Date:House Vicki Lynne BarenbergBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Great Room M Lin 2 Exposed wall 32.5 ft 6.0 ft 3 Room height 9.5 heat/coolft 8.0 heat/coolft 4 Room dimensions ft408.3x1.0 ft3.0x3.0 5 Room area 408.3 ft²9.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nn 2.052.05 1.721.72 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.077.07 0 0 0 0 0 0 0 0 .GG Impact, OBSCImpact, OBSC 0.3000.300 nn 8.708.70 7.077.07 0 0 0 0 0 0 0 0 .WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nene 2.052.05 1.721.72 0 0 0 0 0 0 0 0 11 GG ImpactImpact 0.3100.310 nene 8.998.99 15.9715.97 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ee 2.052.05 1.721.72 176 124 254 212 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.1820.18 31 0 280 630 0 0 0 0 DD DftDoorDftDoor 0.1270.127 ee 3.693.69 3.733.73 21 21 77 78 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 sese 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 sese 8.998.99 15.3415.34 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ss 2.052.05 1.721.72 0 0 0 0 24 24 49 41 GG ImpactImpact 0.2800.280 ss 8.128.12 8.808.80 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ss 8.998.99 9.069.06 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ww 2.052.05 1.721.72 133 91 187 156 24 24 49 41 GG ImpactImpact 0.3000.300 ww 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ww 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 25.5725.57 42 0 402 1074 0 0 0 0 GG Impact, OBSCImpact, OBSC 0.3000.300 ww 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" DW Ex 0.101Frm Wall, 1/2" DW Ex 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC R-20 IcyneneR-20 Icynene 0.4050.405 --1.591.59 1.221.22 408 408 648 499 9 9 14 11 FF On Grade, Tile Flr 0.989On Grade, Tile Flr 0.989 --28.6828.68 0.000.00 408 33 932 0 9 6 172 0 6 c) AED excursion 3 -5 Envelope loss/gain 2780 2653 285 88 12 a) Infiltration 602 168 94 26 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 2 460 0 0 Appliances/other 900 0 Subtotal (lines 6 to 13)3381 4181 378 115 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 12 9 -378 -115 14 Subtotal 3393 4189 0 0 15 Duct loads 31%41%1059 1701 31%41%0 0 Total room load 4452 5891 0 0 Air required (cfm)Air required (cfm)193 275 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-13 16:17:26Right-Suite® Universal 2019 19.0.19 RSU27054 Page 6...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: N 629Job:Right-J® Worksheet Oct 29, 2019Date:House Vicki Lynne BarenbergBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name M Bath Wtr Clst 2 Exposed wall 21.5 ft 6.5 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft131.5x1.0 ft6.5x4.0 5 Room area 131.5 ft²26.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nn 2.052.05 1.721.72 52 52 107 89 52 48 98 83 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.077.07 0 0 0 0 0 0 0 0 .GG Impact, OBSCImpact, OBSC 0.3000.300 nn 8.708.70 7.077.07 0 0 0 0 4 0 35 28 .WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nene 2.052.05 1.721.72 0 0 0 0 0 0 0 0 11 GG ImpactImpact 0.3100.310 nene 8.998.99 15.9715.97 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ee 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 DD DftDoorDftDoor 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 sese 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 sese 8.998.99 15.3415.34 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ss 2.052.05 1.721.72 40 40 82 69 0 0 0 0 GG ImpactImpact 0.2800.280 ss 8.128.12 8.808.80 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ss 8.998.99 9.069.06 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ww 2.052.05 1.721.72 80 68 140 117 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ww 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 25.5725.57 0 0 0 0 0 0 0 0 GG Impact, OBSCImpact, OBSC 0.3000.300 ww 8.708.70 21.5021.50 12 0 104 258 0 0 0 0 PP Frm Wall, 1/2" DW Ex 0.101Frm Wall, 1/2" DW Ex 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC R-20 IcyneneR-20 Icynene 0.4050.405 --1.591.59 1.221.22 132 132 209 161 26 26 41 32 FF On Grade, Tile Flr 0.989On Grade, Tile Flr 0.989 --28.6828.68 0.000.00 132 22 617 0 26 7 186 0 6 c) AED excursion 89 -7 Envelope loss/gain 1258 782 361 135 12 a) Infiltration 335 94 101 28 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1593 876 462 164 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 383 118 0 0 14 Subtotal 1976 994 462 164 15 Duct loads 31%41%617 404 31%41%144 66 Total room load 2593 1398 607 230 Air required (cfm)Air required (cfm)112 65 26 11 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-13 16:17:26Right-Suite® Universal 2019 19.0.19 RSU27054 Page 7...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: N 629Job:Right-J® Worksheet Oct 29, 2019Date:House Vicki Lynne BarenbergBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Closet WIC 2 Exposed wall 0 ft 7.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft7.0x3.0 ft7.0x6.0 5 Room area 21.0 ft²42.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nn 2.052.05 1.721.72 0 0 0 0 56 56 115 96 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.077.07 0 0 0 0 0 0 0 0 .GG Impact, OBSCImpact, OBSC 0.3000.300 nn 8.708.70 7.077.07 0 0 0 0 0 0 0 0 .WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nene 2.052.05 1.721.72 0 0 0 0 0 0 0 0 11 GG ImpactImpact 0.3100.310 nene 8.998.99 15.9715.97 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ee 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ee 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 DD DftDoorDftDoor 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 sese 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 sese 8.998.99 15.3415.34 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ss 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.2800.280 ss 8.128.12 8.808.80 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ss 8.998.99 9.069.06 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ww 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ww 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 25.5725.57 0 0 0 0 0 0 0 0 GG Impact, OBSCImpact, OBSC 0.3000.300 ww 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" DW Ex 0.101Frm Wall, 1/2" DW Ex 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC R-20 IcyneneR-20 Icynene 0.4050.405 --1.591.59 1.221.22 21 21 33 26 42 42 67 51 FF On Grade, Tile Flr 0.989On Grade, Tile Flr 0.989 --28.6828.68 0.000.00 21 0 0 0 42 7 201 0 6 c) AED excursion -1 -8 Envelope loss/gain 33 25 382 140 12 a) Infiltration 0 0 109 30 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)33 25 491 171 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -33 -25 0 0 14 Subtotal 0 0 491 171 15 Duct loads 31%41%0 0 31%41%153 69 Total room load 0 0 645 240 Air required (cfm)Air required (cfm)0 0 28 11 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-13 16:17:26Right-Suite® Universal 2019 19.0.19 RSU27054 Page 8...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: N 629Job:Right-J® Worksheet Oct 29, 2019Date:House Vicki Lynne BarenbergBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Master Suite 2 Exposed wall 45.8 ft 3 Room height 8.8 heat/coolft 4 Room dimensions ft337.3x1.0 5 Room area 337.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area Load number (Btuh/ft²-°F)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Blk Wall, Stucco Ext 0.071 n 2.05 1.72 198 198 406 340 .G Impact 0.300 n 8.70 7.07 0 0 0 0 .G Impact, OBSC 0.300 n 8.70 7.07 0 0 0 0 .W Blk Wall, Stucco Ext 0.071 ne 2.05 1.72 44 28 58 49 11 G Impact 0.310 ne 8.99 15.97 15 0 136 242 W Blk Wall, Stucco Ext 0.071 e 2.05 1.72 48 33 67 56 G Impact 0.310 e 8.99 20.18 16 0 140 315 G Impact 0.310 e 8.99 20.18 0 0 0 0 D DftDoor 0.127 e 3.69 3.73 0 0 0 0 W Blk Wall, Stucco Ext 0.071 se 2.05 1.72 44 28 56 47 G Impact 0.310 se 8.99 15.34 16 2 144 246 W Blk Wall, Stucco Ext 0.071 s 2.05 1.72 70 70 144 121 G Impact 0.280 s 8.12 8.80 0 0 0 0 G Impact 0.310 s 8.99 9.06 0 0 0 0 W Blk Wall, Stucco Ext 0.071 w 2.05 1.72 0 0 0 0 G Impact 0.300 w 8.70 21.50 0 0 0 0 G Impact 0.310 w 8.99 20.18 0 0 0 0 G Impact 0.330 w 9.57 25.57 0 0 0 0 G Impact, OBSC 0.300 w 8.70 21.50 0 0 0 0 P Frm Wall, 1/2" DW Ex 0.101 -2.94 1.46 0 0 0 0 C R-20 Icynene 0.405 -1.59 1.22 337 337 535 412 F On Grade, Tile Flr 0.989 -28.68 0.00 337 46 1315 0 6 c) AED excursion 65 Envelope loss/gain 3003 1894 12 a) Infiltration 787 220 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 200 Subtotal (lines 6 to 13)3790 2314 Less external load 0 0 Less transfer 0 0 Redistribution 17 12 14 Subtotal 3807 2326 15 Duct loads 31%41%1188 945 Total room load 4995 3271 Air required (cfm)216 153 Bold/italic values have been manually overridden 2020-May-13 16:17:27 Right-Suite® Universal 2019 19.0.19 RSU27054 Page 1 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: N 629Job:Duct System Summary Oct 29, 2019Date:House Vicki Lynne BarenbergBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Dunn, Groza Builders, IncFor: 0 Slash Pine Trail, Fort Pierce, FL 34951 CoolingHeating External static pressure in H2O0.60in H2O0.60 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.60in H2O0.60 Supply / return available pressure 0.471 / 0.129 in H2O in H2O0.471 / 0.129 Lowest friction rate in/100ft0.135in/100ft0.135 Actual air flow cfm953cfm953 Total effective length (TEL) ft446 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st3200.031.8VlFx0x04.00.2031633634hBath 2 st3200.030.2VlFx0x07.00.2051001352603hBed 2 st2200.010.8VlFx0x06.00.224741132171hBed 3 st4300.046.1VlFx0x08.00.1361651162945cGreat Room st1205.034.2VlFx0x08.00.1971651162945cGreat Room-A st2200.013.0VlFx0x07.00.221142742544cKit/Nook st3200.028.1VlFx0x07.00.207142742544cKit/Nook-A st2200.011.4VlFx0x04.00.2235225936cLaundry st4300.046.8VlFx0x07.00.136781352593hM Bath st1205.038.7VlFx0x07.00.193921302497hMaster Suite st1205.046.5VlFx0x07.00.187921302497hMaster Suite-A st4300.044.3VlFx0x04.00.1371333645hWIC st4300.050.2VlFx0x04.00.1351331607hWtr Clst Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st4 Peak AVF 315 269 0.135 578 10.0 0x0 VinlFlx st1 st1 Peak AVF 690 617 0.135 646 14.0 0x0 VinlFlx st2 Peak AVF 211 269 0.221 608 9.0 0x0 VinlFlx st3 Peak AVF 242 258 0.203 583 9.0 0x0 VinlFlx 2020-May-13 16:17:27 Right-Suite® Universal 2019 19.0.19 RSU27054 Page 2 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb5 0x 1350 100 69.5 0.185 506 7.0 x0 0 VlFx rt1 rb3 0x 2930 197 95.7 0.135 537 10.0 x0 0 VlFx rt1 rb4 0x 1130 74 43.3 0.297 574 6.0 x0 0 VlFx rb2 0x 6030 774 62.0 0.208 554 16.0 x0 0 VlFx rt1 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 1031 1070 0.135 490 20.0 0x0 VinlFlx 2020-May-13 16:17:27 Right-Suite® Universal 2019 19.0.19 RSU27054 Page 1 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: N 629Job:Manual S Compliance Report Oct 29, 2019Date:House Vicki Lynne BarenbergBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Dunn, Groza Builders, IncFor: 0 Slash Pine Trail, Fort Pierce, FL 34951 Cooling Equipment Design Conditions °F77.0Entering coil DB:Btuh21238Sensible gain:°F90.4Outdoor design DB: °F64.1Entering coil WB:Btuh6407Latent gain:°F77.4Outdoor design WB: Btuh27645Total gain:°F75.0Indoor design DB: cfm953Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ACEquipment type: 14ACXS030-230A**+CBA27UHE-030-230*++TDRModel:LennoxManufacturer: cfm953Actual airflow: % of load94Btuh20020Sensible capacity: % of load134Btuh8580Latent capacity: %70SHR:% of load103Btuh28600Total capacity: Heating Equipment Design Conditions °F68.0Entering coil DB:Btuh23547Heat loss:°F41.0Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Elec stripEquipment type: Model:Manufacturer: cfm953Actual airflow: °F51Temp. rise:% of load100kW6.9Output capacity: Meets all requirements of ACCA Manual S. Job #: 629 Performed by Vicki Lynne Barenberg for: Dunn 0 Slash Pine Trail Fort Pierce, FL 34951 Air Calcs, LLC 7550 Hidden Hammock Ln Vero Beach, FL 32966 Phone: 772.800.8413 vickilynne@aircalcs.com Scale: 1 : 240 Page 1 Right-Suite® Universal 2019 19.0.19 RSU27054 2020-May-13 16:17:57 ...ft HVAC\Dunn Residence Groza.rup N Level 1 Garage Bed 3 Bath 2 Lin Bed 2 Hall Laundry Kit/Nook Great Room M Lin M Bath Wtr Clst Closet WIC Master Suite 10 x 10 165 cfm6 x 6 52 cfm 36 x 18 774 cfm 8 x 4 33 cfm 10 x 10 142 cfm 10 x 10 142 cfm 12 x 8 135 cfm 12 x 12 135 cfm 12 x 12 113 cfm 6 x 6 33 cfm 18 x 18 293 cfm 10 x 10 130 cfm 6 " 20 " 10 " 7 " 4 " 7 " 7 " 4 " 7 " 9 "9 " 10 " 4 " 14 " 8 " 7 " 10 x 10 165 cfm 10 x 10 135 cfm 8 x 4 31 cfm 10 x 10 130 cfm 12 x 8 113 cfm 8 " 7 "4 " 7 " 6 "