Loading...
HomeMy WebLinkAboutPermit Worksheete Y"°'• a ,y WON :: jy'; ,:... ., PtRiWIT NUMBER Installer/��) �' qw frir` e License # Address of home ZrJi � �4 tJA,, PFi�r( $ftrJ� �Gri �t/SSZ being Installed Manufacturer �butteS U�l�(Aab.tf LengthxWidth -&17 �4 NOTE: ' if home Is a single wide fill out one half of the blocking plan PERMIT WORK -SHEET � paye7ota New Home . ® Used Home 0— Home Installed to the Manufacturer's Installation Manual Home is installed in accordance with Rule 15-0 ®� single wide Double wide If home !s a triple or quad wide sketch In temalnder of home i nplaVduaa I understand Lateral Ann Systems cannot be used on any home (new or us where the sldewall ties exceed 5 It 4 in, Installer's Initials Typical pier lacing 2, L/ .Ila.emi I-MuLdnel Inenlega WeuPlem WINn 2'of end of hmne ®WindZonell ❑ Wind Zone111 ❑ t��Installation Decal _s���1 ® serial 0 _p(- in lnf 3 Sp. q,7 3 e r 72 q % PIER SPACING TABLE FOR USED HOMES Load 6eadng' Footar slze IVX16° 1a119'X18I12° 20'X20' 22°x22} 24'X24' . 2s'x26' eapaoliy (sq In) (.259). (342) . (400) _ (464)° (576)0 (676) 1000 s 9 00 s 4 6 8 8 ' ODD 6 200 s 6 8 8 8 3000 8 8 900. s8' 8 PIEA PAD SIZES .r ._. pier pad size er pier pad size t 2 x'Z,-4- er pad sizes (7 X2Z Draw the approximate locations of marrlag wall openings 4 foot or greater. Use this tsc symbol to show the piers, List all marriage well openings greater than 4 foot and.their pier pad sizes below. Opening Pierpad:size (4( Sr f -7 XZZ TIEDOWN CDMPONENTs Longllrtd[nat Stablflaing Device (LSD) Manufacturer�ua Jd eM-4r Longitudinal Stab] laing Device w/Lateral Ardis 'Manufacturer- (Mt.JJ'Fc'-.-�±-.. POPULAR PADsIZEs 4fty3(( FRAMETIEs Within 2' of end of homi--� spaced at S' 40 oo _ OTHER TIE6 Sidewall- Longitudinal Marriage wall shearwall POCKET PENETROMETER TEST The pocket penstrometertests are rounde5l, rn to psi orcheck here4odeclare lDOD lb. soil withouttastinq. X® X® X_ POCKET PENETROMETER TESTING METHOD i. Test the perimeter of the home at 6 locations. 2. Take the reading at the depth of the footer. 8. uxing 500 lb. increments, take the lowest reading and round down to that Increment X X®. X__ TORQUE PROBE TEST - The results of the torque probe test is inch pounds or check here if you are declaring 5' anchore without testing _ _ A test showing 275 inch pounds or less will require 5 foot anchors, Note: A state approved lateral arm system is being used and 4 ft. .anchors are allowed at the sidawall locations. I understand S.ft anefinrs are required at all centerline tie points where the torque test reading Is 275-or less and where the mobile home manufacturer may requires anchors with 40W'L `�'ng capacity. e) Installees initials ALL TESTS MUST BE PERFORMED BY A LICENSED INSTALLER Installer Name. W: A/it%Q_ 4i C Cry Date Tested "Electrical Ionnect electrical conductors between multi -wide units, but not to the main power ourae. This•Inctudesthe bonding wire between mult-wide units Pg. anneot all sewer drains to an Odsting sewar tap or septic tank Pg, onnect all potable Wafer supply piping to an ex ' g water meter, water tap, or other !dependent Water supply systems. Pg. IJERMrr ViWORKSHEET . page 2 of 2 I site PreoaraUcn Debris and organic material remoyed Water drainage: Natural Shale Pad _other ' - Fastening multi Wlde units Floor. , Type Fastener Length: 6 �i spacing: Zy Walls Type Fastener. Length: • _ spacing; Roof: Type Fastener. Length, ( rl spacing: ,v For -used homes a min. 80 gauge,!8" wide, galvanized metal strip will be centered'over the peak of the roof and fastened With gals. roofing nails at 2" on center on both sides of the centerline, - Gasket(wmth!M:..0nd r"eui 0 i understand a property Installed gasket Is a rquirement of all nowand used e homes and that condensation, mold, mellow and buckled ma 'age walls are a result of a poorly installed or no gasket being installed: I Uri ersland a strip of tape will not serve as a gasket. Installsee initials Type gasket y_ - Installed: Pg. Between Floors Yes Between Walls Yes Bottom of rfdgebsam Y� Weather aroo}Ino - - The bottomboard will be repaired andlor taped. yes ✓ Pq, Siding an units Is installed to manufacturer's specigcatlons. Yes Fireplace chimney Installed so as not to allow intrusion of min water.' Yes L/ Skirting to be.installed. Yes PNo Dryer vent installed outside R skirting. Yes ' �WA Range downflow vent installed•cutsids of skirting. Yes %`—WA Drain lines supported at 4 foot intervals. Yes Electrical crossovers protected Yes Other: Installer acqurate. and true based on tfte !say & Data � W2. o