HomeMy WebLinkAboutMobile Home Inspection ReportI S'•r zJ'� Rai St Lucie County Building & Zoning 2300 Virginia Avenue Ft Pierce, FL 34982 Mobile Home Inspection Report All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this completed Inspection Report and copies of both sides of the Title to the home. All used Mobile homes must be Wind Zone II certified. Owner: W MA(E &-o& eQRP Date: (Print or type) Address: Year / Manufacturer r r Widthg7 Length Single C = In Compliance N = Not in Compliance /1 l: 9025 50vgl s tt LAKES -MR WAYS M K1P FLA& O S3 36 Plate # FIA 6oT 337 Double t/ Wind Zoneyr— Fire Safety / Electrical _ 1. Smoke Detector: Installed Missing 2. Electrical System Checked: Exposed Wiring _Other _AC, — 3. Distribution Panel: Missing Loose_ Main Missing_ Breaker Missing_ Unplugged Opening Other 4. Electrical Fixtures: Missing Installed Improperly Improperly Wired Loose Wire_ GFCI receptacles not where required_ 5. Electrical Ground: Chassis Main Panel Gas Pipe Revisal 3/9105 Page I of 3 FILE copy Construction C 1. Exit Doors Operable: Front Back Other 2. Exit Door Locks: Missing Inoperable 3. Egress windows: Missing Inoperable 4. Windows: Broken Glass Inoperable 5. Screens: Missing Damaged_ 6. Floor System: Joist Decking Area Damaged 7. Interior Paneling: Missing Loose _ Damaged_ 8. Rodent Proofing: Bottom Board Pipe openings —Other 9. Leaks Apparent: Ceiling _ Doors _ Floor _ Roof _ 10. Vertical tie -down straps: Missing _ Short _ Damaged_ _ 11. Structural modifications since manufactured: YES_ NO--V/— 12. Walls: Structurally Unsound _ Loose _ Weather tight Plumbing 1. Trap: Missing Not connected Other 2. Plumbing fixtures: Missing _ Not installed _ Not Vented _3. Relief Valve: Missing Inoperable Other _4. Drain Waste and Venting Piping: Missing Not supported_ Clean outs Use of fittings _ Not capped_ Heating and Air Conditioning 1. Heating Appliances: Missing Not Connected Other 2. Deleted Heating/AC system: Not installed Other s_3. Thermostat: Missing Inoperable 4. Air registers: Missing Inoperable --AC,_ 5. Ducts: Not sealed Missing Collapsed Page 2 of 3 FILE COPY n 6. Gas furnace Water heater vent: Missing 7. Return Air: To Furnace To A/C 8. Range: Vent Hood Loose From rooms 9. Gas Valve: Accessible Installed improperly 10. Gas lines: Not capped Not supported Kinked Not bonded Summary 1. Is subject structure found to be fifty (50%) or more damaged or deteriorated? YES NO__V/ 2. Willa remodeling permit be required? YES NO--%/—�— The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be limited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and life safety. FS 320.8232 IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX THEIR SEAL. Date inspected: 3.LAOAO.aO Inspected By: V' WOOD f. O _,—_ sign rura requlred Phone Number: (/�/�//"all License # 3 `f 35S Page 3 of 3 FILE COPY STEVEN G. WOOD, P.E. FL LICENSE W98 950 SULTAN DR PORT ST LUCIE, FL