Mobile Home Inspection Report
All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this
completed Inspection Report and copies of both sides of the Title to the home.
All used Mobile homes must be Wind Zone II certified.
Owner: W MA(E &-o& eQRP Date:
(Print or type)
Address:
Year / Manufacturer
r r
Widthg7 Length Single
C = In Compliance N = Not in Compliance
/1
l:
9025
50vgl s tt LAKES
-MR WAYS M K1P
FLA& O S3 36
Plate # FIA 6oT 337
Double t/ Wind Zoneyr—
Fire Safety / Electrical
_ 1. Smoke Detector: Installed Missing
2. Electrical System Checked: Exposed Wiring _Other
_AC, — 3. Distribution Panel: Missing Loose_ Main Missing_ Breaker Missing_
Unplugged Opening Other
4. Electrical Fixtures: Missing Installed Improperly
Improperly Wired Loose Wire_
GFCI receptacles not where required_
5. Electrical Ground: Chassis Main Panel Gas Pipe
Revisal 3/9105
Page I of 3
FILE copy
Construction
C 1. Exit Doors Operable: Front Back Other
2. Exit Door Locks: Missing Inoperable
3. Egress windows: Missing Inoperable
4. Windows: Broken Glass Inoperable
5. Screens: Missing Damaged_
6. Floor System: Joist Decking Area Damaged
7. Interior Paneling: Missing Loose _ Damaged_
8. Rodent Proofing: Bottom Board Pipe openings —Other
9. Leaks Apparent: Ceiling _ Doors _ Floor _ Roof _
10. Vertical tie -down straps: Missing _ Short _ Damaged_
_ 11. Structural modifications since manufactured: YES_ NO--V/—
12. Walls: Structurally Unsound _ Loose _ Weather tight
Plumbing
1. Trap: Missing Not connected Other
2. Plumbing fixtures: Missing _ Not installed _ Not Vented
_3. Relief Valve: Missing Inoperable Other
_4. Drain Waste and Venting Piping: Missing Not supported_
Clean outs Use of fittings _ Not capped_
Heating and Air Conditioning
1. Heating Appliances: Missing Not Connected Other
2. Deleted Heating/AC system: Not installed Other
s_3. Thermostat: Missing Inoperable
4. Air registers: Missing Inoperable
--AC,_ 5. Ducts: Not sealed Missing Collapsed
Page 2 of 3
FILE COPY
n 6. Gas furnace Water heater vent: Missing
7. Return Air: To Furnace To A/C
8. Range: Vent Hood
Loose
From rooms
9. Gas Valve: Accessible Installed improperly
10. Gas lines: Not capped Not supported Kinked
Not bonded
Summary
1. Is subject structure found to be fifty (50%) or more damaged or deteriorated? YES NO__V/
2. Willa remodeling permit be required? YES NO--%/—�—
The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent
than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be
limited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and life safety. FS 320.8232
IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO
BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY,
A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS
MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT.
NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE-
LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN
SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED.
A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX
THEIR SEAL.
Date inspected: 3.LAOAO.aO Inspected By: V' WOOD f. O
_,—_ sign rura requlred
Phone Number: (/�/�//"all
License # 3 `f 35S
Page 3 of 3
FILE COPY
STEVEN G. WOOD, P.E.
FL LICENSE W98
950 SULTAN DR
PORT ST LUCIE, FL