Loading...
HomeMy WebLinkAboutBuilding PlansST LUCIE BLVD N LOCATION MAP nts SCREW ANCHOR STUCCO EXTERIOR FRAME WALL EXTERIOR DRYWALL CONTINOUS CAULKING /4- SHIM WINDOW ANCHOR THROUGH FIN FRAME SUBSTRATA —e.T. SDDTHERN NNE(S W) Mln. EMBEDMENT — 1_3/�2' Mln. EDGE MSTANCE i Max D.C. DISTANCE — 1T-e/1e• a Hw /91 6 20' .mob. M. CORNER DISTANCE - 8-1/2• WINDOW FRAME SILL STUCCO L1/4- SHIM DRYWALL SCREW ANCHOR EXTERIOR FRAME WALL SECTION SINGLE HUNG RMEll 4060 Single Hung ASS -Type 1/8 ANNEALED_.TINTED Wind Pressure + WIND ZONE 4 PROVIDED /— 43.9 psf CALCULATED +28.9 psf / —31.5 psf WINDOW SIZE 48"x 60" BUCK OPENING 47"x 59" ALL WINDOW FRAMES, SASHES SHALL BE EXTRUDED ALUMINUM 6063—T5 ALLOY PROVIDE APPROVED TYPE STORM PANEL PROTECTION FOR ALL WINDOWS (NEW) Existing Mono Slope Roof Overhang 'sTU PLATE TIE ( RSP4 TOP of WINDOW 5/8" CD PLYWOOD SHEATHING SECURED TO 2x4 WOOD STUDS TOP AND BOTTOM PLATES AND EXISTING WOOD BEAM SMALL DIAMOND MESH LATH PAPER BACKED STUCCO FINISH CONTINOUS CAULK PERIMETER i0 Grade / Con Existing Roof Joists Existing Wood Beam Existing Pipe Column supporting Existing wood beam TO REMAIN NON BEARING Existing FRAME WALL PORTION AREA TO BE REPLACED 2x4 WOOD TOP PLATE SECURE TO EXISTING WOOD BEAM 16d NAILS ® 12" o.c. —R-11 INSULATION 2x4 TREATED WOOD BASE PLATE FIBERGLASS BATT 3-1/2" CAVITY r-11 SECURE TO CONCRETE w/ TAPCON SCREWS 1/4" x 1-1/2" EMBED SPACED 16" D.C. " FROM ENDS SIMPSON STUD PLATE TIE (RSP4 ) DO (EACH SIDE 1/2" NAIL PLATE/STUD 2x4 WOOD STUDS SPACED 0 16" O.C. 2x4 WOOD BASE PLATE Existing STUD PLATE TIE Finish Floor Elevation (RSP4 ) 4 .'Existing CONCRETE SLAB . '4r `i� " e'. •d SECTION S-1 sc 3/4" = 1'- 0" THESE DOCUMENTS HAVE BEEN PREPARED ACCORDING TO THE FOLLOWING REQUIREMENTS- FLORIDA BUILDING CODE 6th EDITION 2017. ASCE 7-10 160 MPH CATEGORY "C" FBC EXISTING BUILDINGS BS 606.2 BS; 606.2.1 REPAIRS FOR LESS THAN SUBSTANTIAL STRUCTURAL DAMAGE RESTORED TO THEIR PREDAMAGED CONDITION) - CONTRACTOR AND SUB CONTRACTORS SHALL VISIT SITE AND VERIFY ALL CONDITIONS BEFORE PROCEEDING WITH ANY COMMENCEMENT OF WORK OR ANY MATERIAL ORDERING. NOTIFY THIS ARCHITECT AND ENGINEERS OF ANY ERRORS, OMISSIONS OR CHANGES BEFORE COMMENCEMENT OF PROJECT. - ALL WOOD IN CONTACT WITH CONCRETE SHALL BE TREATED OR OTHERWISE PROTECTED WITH TYPE 30 FELT MEMBRANE BARRIER. \ I - WOOD GRADE FOR STUDS AND TOP PLATES SHALL BE SOUTHERN PINE - STANDARD GRADE. BASE PLATES SHALL BE No. 2 SOUTHERN PINE TREATED SURFACE DRY USED AT MAX. 19% MOISTURE CONTENT. - STRUCTURAL GRADE LUMBER SHALL BE MIN. Fb = 1,200 PSI UNLESS OTHERWISE SPECIFIED. NAILS FOR - STUD TO STUD PLATE - (2) 16d STUD TO SOLE PLATE / TOE NAIL- (2) 8d DOUBLE TOP PLATE- (2) 16d NAIL ® 12"o.c. - TOP PLATES IN BEARING WALLS SHALL BE DOUBLED AND LAPPED AT INTERSECTION OF WALLS AND PARTITIONS. JOINTS SHALL BE LAPPED NOT LESS THAN (4) FEET - CORNER OF STUD WALLS SHALL BE FRAMED SOLID BY NOT LESS THAN 3 STUDS WITH 16d NAILS ® 12" o.c.. CORNER STUD SECURED TO (3) MEMBER STUDS (2) 16d NAILS ® 6"o.c.. T TOP PLATES IN NON -BEARING PARTITIONS SHALL BE SINGLE - SOLE PLATES IN NON -BEARING PARTITIONS SECURE TO CONCRETE SLAB WITH TAPCON FASTENER 1/4"x 1-1/2" EMBED or HILTI POWDER ACTUATED FASTENER PIN DIN 72 P08 x 0.145 SHANK Dia. - WHERE VERTICAL PIPES POSITIONS NECESSITATE THE CUTTING OF PLATES, A METAL TIE 1"x 1/8" SHALL BE PLACED EACH SIDE OF WOOD PLATE ACROSS THE OPENING 6" PAST AND NAILED WITH (2) 16d ad 8d COMMON NAILS AT EACH END. — — I - HEADERS OR LINTELS OVER STUD WALL OPENINGS SHALL BEAR NOT LESS THAN (3) 2x J JACK STUDS or HANGER SECURED TO NOT LESS THAN (3) KING STUDS. - PLYWOOD SHEATHING - 5/8" CD FASTENERS- NAILS (8d ) COMMON, SPACED ® (6") ON CENTER OVER ALL SUPPORTS AND BLOCKING UNLESS SPECIFIED OTHERWISE - WALLBOARD SHALL BE ASTM C36-85 REGULAR 1/2" / ASTM C36-85 TYPE "X" FIRE RATED / ASTM C117 (MOISTURE RESISTANT) UNLESS SPECIFIED OTHERWISE. —JOINT TREATMENT SHALL BE COMPOUND AND TAPE (READY MIX) ASTM C475-88 CORNER BEAD ASTM C1047-85 PANEL ADHESIVE SHALL BE STA-STUCK SS-200, ASTM C-557-73 - PROVIDE MIN. 1/2" AIR GAP BETWEEN FLOOR AND WALLBOARD BOTTOM - ATTACHMENTS FOR WALLBOARD TO SUPPORTS SHALL BE - METAL STUDS- TYPE W 1-1/4" DRYWALL SCREWS SPACED ® 12"o.c. WOOD STUDS & FURRING- NAILS GWB-54 ANNUAL RING 1/4" HEAD, .098 Dia SHANK ATTACHMENT SPACING / CEILING- 7" o.c. / WALLS- 8" o.c. WIRE LATH- SMALL DIAMOND LATH PAPER BACKED OVERLAP EDGES ONE (1") ATTACHMENTS FOR SECURING LATH TO SUPPORTS SHALL BE SPACED NOT MORE THAN 6" APART AND SIDE LAPS SHALL BE SECURED TO SUPPORTS AND TIED BETWEEN SUPPORTS AT NOT TO EXCEED 9" INTERVALS. ATTACHMENTS TO CEILING SUPPORTS SHALL BE No. 11 go x 1" LONG WITH 3/8" Dia. HEAD PROVIDE TYPE 30 ROOF FELT BETWEEN ALL WOOD AND LATH .STUCCO - ASTM C926 / (1) PART PORTLAND CEMENT TO A MAX. 2-1/2 PARTS SAND BY VOLUME ( MIXED PROPORTION) - RIB LATH- (3) COAT APPLICATION / Min. 1/2" THICKNESS - PLASTIC PC COMPONENTS- PVC ACCESSORIES & PLASTIC LATH FIBERGLASS BATT 3-1/2" CAVITY r-11 SCOPE OF WORK REPi_ACE EXTERIOR FRAME WALL PORTION DAMAGED AND WINDOW FBC EXISTING BUILDINGS ((BS 606.2 (BS 606.2.1 REPAIRS FOR LESS THAN SUBSTANTIAL STRUCTURAL DAMAGE ((RESTORED TO THEIR PREDAMAGED CONDITION) AP# pa A"Ifty, 9/ q9e J od` J Q-° ova°E OF F.tO P � y�•' • TO REMAIN • ::�Oi6ERT G IS y�9 t7 -Existing Pipe Column supporting Existing $ ec mi AR72684 1. wood beam Existing Cam., V Door tP� ..� Existing New V AFZO'� Window Window 4060 3H ---- 4'-11" Existing FRAME WALL PORTION AREA TO BE REPLACED RE EWED 0 N FLOOR PLAN sc 1/4"= 1'-0" CODE COMPLIA E ST. LUCIE COUNTY BOCC FRONT ELEVATION Sc 'i 4"= 1'-0" SOUTH Drip Edge Fascia U61TOM of EXISTING WOOD BEAM II r—I I —I II Elevation FILE COP` Date 3/16/2020 Rev `l z m fW V Q Q I 0 Q W J I) m ry W r­� o U w S Q U _J LLL o _ W " o W _j LLJ I U C z Q Od 010 W N Q�i-� 0- 0 1Y W N 0 O ryNLLL a` rr(frrrrr^ (f --__,SEA SEAL -�JJJJJJ )) ROBERT G. ISHMAN Q ~ a N Z CJ M M p> J a U) U) morn D0 a0a01 0 6_�;�;�� U of Jo0) w Ld In o It x i OQ W CIDn Jv PROJECT No. S H E E T A-1 of 1