Loading...
HomeMy WebLinkAboutPlot PlansPROJECT DESCRIPTION: 40x335 LG335N1C-V5 (335W) MODULES ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES SYSTEM SIZE: 13.40 kW DC STC ARRAY AREA #1: 645.40 SO FT. ARRAY AREA #2: 92.20 SQ FT. EQUIPMENT SUMMARY 40 LG335N1 C-V5 (335W) MODULES 40 ENPHASE IQ7-60-2-US MICROINVERTERS GOVERNING CODES: FLORIDA RESIDENTIAL CODE, 6TH EDITION 2017 (FRC) FLORIDA PLUMBING CODE, 6TH EDITION 2017 (FPC) FLORIDA BUILDING CODE, 6TH EDITION 2017 EDITION (FBC) FLORIDA MECHANICAL CODE, 6TH EDITION 2017 (FMC) SHEETINDEX A-00 PLOT PLAN & VICINITY MAP A-01 SYMBOLS & SYSTEM DESCRIPTION S-01 ROOF PLAN & MODULES S-02 STRUCTURAL ATTACHMENT DETAILS E-01 ELECTRICAL LINE DIAGRAM E-02 WIRING CALCULATIONS E-03 SYSTEM LABELING DS-01 MODULE DATA SHEET DS-01.1 TEST LETTER DATA SHEET DS-02 INVERTER DATA SHEET DS-03 COMBINER DATA SHEET DS-04 RAIL DATA SHEET DS-05 ATTACHMENT DATA SHEET NEC 2014 CODE BOOK ST.LUCIE COUNTY PLAN REVIEW FILE COPY BLDG: / 5 DA ELIE / / / \ �� DA \ DATE:�"�2� PLUMB: / / EXISTING 'L DATE: DRIVEWAY (31 (3G) MECH: / / \ (Piz G DATE: dol 1-STORY / HOUSE coo 3ge'S \ o � R/ / PANEL ROOF (05) LG335N1C-V5 (335W) / \ MODULES / �5 ROOF #1 (35) LG335N1C-V5(335W) MODULES / T SETBACK REQ.J NT ES CNR SIDES F ���' AR ZNG. 1 PLOT PLAN WITH ROOF PLAN COPYRIGHTED BY CASTILLO A-00 SCALE: 1/16"=1'-0" ENGINEERING SERVICES, LLC 2 I HOUSE PHOTO A-00 ortt, r'iercel t i 8937 Charr PROJECT SITES Castillo G(mk Engineering o ula Nee ro rumor CASTILLO ENGINEERING SERVICES, LLC WA42& 5 2 25 W. STATE ROAD 434, SuRE 111 LONGWOOD, FL 32A8 ML(J )0075 EAMOp24rE5 E GST LLO - FL PE 52550 REVISIONS DESCRIPTION DATE REV PROJECTINSTALLER 4007 0 590 SCALE: NT Sro• �. ATE F PROJECT SITE 'T ° °� ieooLeNp U z W 0 U) W W a �00 j�co m in J z "- o ]JU 0- C) Q J 2 � U cl) ti H M � o O- zoo FSHEET NAME PLOT PLAN & VICINITY MAP v,• „ IndantownD= 'I'' SHEET SIZE ANSI B 11" X 17" 3 VICINITY MAP SHEET NUMBER A-00 SCALE: NTS A-00 Symbols: ��� Sheet where Section .............. section is located x-xx Detail ID Letter Elevation ........... Sheet where x.xx section is located Detail ID Letter Detail ................ x x_ Sheet where section is located Detail ID Letter Detail ................ x Ar Area to be enlarged (Enlarged Plan) x"xx Sheet where section is located Keyed Notes .......... 1 Keyed note designation on applicable sheet Ground Terminal..... Grounding Point/rod.... 16 Solar Panel......... or 00----Module with Source Circuit number Combiner Box.......... CB DC Disconnect.......... DCD Main Distribution MDP Panel ...................... Fuse ...................... Overcurrent Breaker .. � Inverter .................... 7— Transformer ............. "T" Automatic ............... ATS Transfer Switch Abbreviations: AC Alternating Current APPROX Approximate AWG American Wire Gauge CB Combiner Box DC Direct Current DIED Direct Current Disconnect DISC Disconnect (E) Existing EL Elevation EQ Equal JB Junction Box MCB Main Combiner Box MFR Manufacturer MIN Minimum MISC Miscellaneous (N) New OCPD OverCurrent Protection Device POCC Point Of Common Coupling PV Photovoltaic SF Squarefoot/feet STC Standard Test Conditions TBD To Be Determined TYP Typical VIF Verify In Field WP Weather Proof System Description This system is a grid -tied, PV system, with PV generation consisting of 40 LG335N1C-V5 (335W) MODULE with a combined STC rated do output power of 13,400W. The modules are connected into 40 ENPHASE IQ7-60-2-US MICROINVERTERS. The inverter has electronic maximum power point tracking to maximize energy captured by the PV modules. The inverter also has an internal ground fault detection and interruption device that is set to disconnect the array in the event that a ground fault that exceeds one ampere should occur. The inverter has DC and AC disconnect integrated system and labels are provided as required by the National Electric Code PV Modules Microinverters—* \ Junction Point of _ Box Utility ConnectionJ31 i Utility Meter When the sun is shining, power from the PV array is fed into the inverter, where it is converted from DC to AC. The inverter output is then used to contribute to the power requirements of the occupancy. If PV power meets the requirements of the loads of the occupancy, any remaining PV power is sold back to the utility. When utility power is available, but PV power is not available, building loads are supplied by the utility. The inverter meets the requirements of IEEE 1547 and UL 1741. This means that if it detects a loss of utility power, it will automatically disconnect from the utility. When utility voltage is restored, the inverter automatically reconnects to the utility grid after verifying utility voltage and frequency stability. On a day with average Florida sunshine, this system outputs 54.78 kWh per day on site. COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC Castillo Engineering oesm NID TO IlrNl7• CASTILLO ENGINEERING SERVICES, LLC 0M. 213115 2925 w STATE ROAD Cal, SUITE 111 LONGWOOD. PL 32779 TEL(407)2Sa2MT5 MMOCMTMSE.0 UO.FLPE52590 REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER S.UNPR. signature win seal gl ll/ I \ ..E. o .* AT OF IJJ C AME P � °L@p111111% U �00 w3co co 0 fn LL w W O Lu Q J w U — t M a00 0 ryry LULU SHEET NAME SYMBOLS & SYSTEM DESCRIPTION SHEET SIZE ANSI B 1111 X 17" SHEET NUMBER A-01 MODULE TYPE, DIMENSIONS & WEIGHT ARRAY & ROOF AREA NUMBER OF MODULES = 40 MODULES CALC'S (ROOF #1) MODULE TYPE = LG335N1C-V5 (335W) MODULES ARRAY AREA = 645.40 SQ. FT. WEIGHT = 37.70 LBS 117.1 KG. ROOF FACE AREA = 1271.20 SQ. FT. MODULE DIMENSIONS = 66.4" x 40" = 18.44 SF 645.40 / 1271.20=50.77% OF ROOF UNIT WEIGHT OF ARRAY = 2.04 PSF FACE AREA COVERED BY ARRAY ROOV: ROOF #1 --� 0 (05) LG335N1C-V5(335W) MODULES RpOF226' PZ' ARRAY & ROOF AREA DESCRIPTION (ROOF #1) ROOF TYPE - W-TILE ROOF TILT - 22.6° ROOF AZIMUTH - 162' TRUSSES SIZE - 2"X4" @ 24" O.0 CALC'S (ROOF #2) ARRAY AREA = 92.20 SQ. FT. ROOF FACE AREA = 345.65 SQ. FT. 92.20 / 345.65=26.67% OF ROOF FACE AREA COVERED BY ARRAY DESCRIPTION (ROOF #2) ROOF TYPE - W-TILE ROOF TILT - 22.60 ROOF AZIMUTH - 252° TRUSSES SIZE - 2"X4" @ 24" O.0 1 ROOF PLAN & MODULES S-01 SCALE: 3/32" = 1'-0" w (N) UNIRAC RAIL (TYP.) (N) (40) ENPHASE IQ7-60-2-US MICROINVERTERS (156) PV ROOF ATTACHMENT @ 24" O.C. MAX ROOF #1 (35) LG335N1C-V5 (335W) MODULES GENERAL INSTALLATION PLAN NOTES: (1) ROOF ATTACHMENTS TO SYP TRUSSES SHALL BE INSTALLED AS SHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE: WIND ZONE 1: 44" O.C. WIND ZONE 2: 28" O.C. WIND ZONE 3: 18" O.C. SEE SHEET S-02 FOR SUPPORTING CALCULATIONS i- 2) EXISTING RESIDENTIAL BUILDING IS A W-TILE ROOF WITH MEAN ROOF HEIGHT 15 FT AND SYP 2X4 WOOD ROOF TRUSSES SPACED 24" O.C. EXISTING ROOF SLOPE FOR SOLAR SYSTEM RETROFIT IS 22.6 DEGREES. CONTRACTOR TO FIELD VERIFY AND SHALL 0 REPORT TO THE ENGINEER IF ANY DISCREPANCIES EXIST Z_ BETWEEN PLANS AND IN FIELD CONDITIONS. _/l I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN 7 COMPLIANCE WITH FBC: RESIDENTIAL CHAPTER 3. BUILDING �Q STRUCTURE WILL SAFELY ACCOMMODATE CALCULATION LATERAL AND UPLIFT WIND LOADS, AND EQUIPMENT DEAD LOADS. �— WIND ZONE 3 (TYP.) a WIND ZONE 2 (TYP.) WIND ZONE 1 (TYP.) t° $ S (N) UTILITY METER y 40" (N) MAIN DISTRIBUTION PANEL (N) AC DISCONNECT (IF REQUIRED) (N) PV METER (IF REQUIRED) - (N) ENPHASE IQ COMBINER BOX 1" PVC CONDUIT RUN � (N) SOLADECK (TYP.) COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC LG335N1C-V5 (335W) MODULES LEGEND ©M - UTILITY METER SD -SOLADECK INV -INVERTER ACD -AC DISCONNECT PM - PRODUCTION METER MDP - MAIN DISTRIBUTION PANEL O ❑ -VENT, ATTIC FAN (ROOF OBSTRUCTION) 0 - PV ROOF ATTACHMENT — -TRUSSES --- -CONDUIT CB -COMBINER BOX Castillo rr(� Engineering Q n DESION[D TO PROMPT* CASTILLO ENGINEERING SERVICES, LLC WAOl 2925 W. STATE ROAD 434. SUITE 111 LONGWOOD, FL 32779 T ''(47)28325n EFWO TESILfASTILL0-FLPER5X REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER 'S U, N P R. No 90 TE 41 W U �00 W 3:v 0 (n LJL U OW 4- U Q -1 W U 1.-:c U) J cM a coo D_ i SHEET NAME ROOF PLAN & MODULES SHEET SIZE ANSI B 11" X 17" SHEET NUMBER S-01 2 r' SUNMODO WOOD DECK MOUNTING SYSTEM THESE TRIPOD MOUNTS ARE USED FOR CURVED TILES OR FLAT TILES TO MOUNT DIRECTLY INTO ROOF DECKING WITHOUT REMOVING TILES. USE ANTI -SEIZE AND TIGHTEN TO TORQUE PER MANUF. INSTRUCTIONS I PHOTOVOLTAIC MODULE TYP: ALUM L-FOOT TYI EACH STANDOFF END CLAMP 8' - 16 HEX CA ST STL BOLT AND ST STL SERRATED UNIRAC RAIL FLANGE NUT TYP. —S #14 X Wood Screws UNMODO TOP TILE W-TILE ROOF ATTACHMENT TILES TYP. (1) 1/4 x 2°L Hanger Bolt, 304SS SHEATHING ROOF. BARRAL TILE CONNECTION DETAIL ATTACHMENT DETAIL (ENLARGED SECTION VIEW) SCALE:NTS ISO I uaeen _ . 1. Va.. ero uNM[o delo 3-5. rmt vim tpeeds I W. Wl.. per tc.ut t- It Ito.) roew Dmm fa' l.o.suro c CK- 2. Wor 1weErOldlm Ybe.n Cm.ms 4 nMlted. a. IdmO m0 Cwd.l .nn wedB. th. I..t .mt..W1 mew 1... Wm •Deed 1 C.U. a tw .w.ul .n.. 4. ibvmdDm ttrr.ln, �rxei, e..m I ...n l..ndnd I. Dm.m Wm mmf- dm.. 9, IP .m.d. Cwre.Dmd tO.p.edv[d: e 7x', filer ar rn uty .04", I Imnvd Ex[tmnn Ma0.E11ftY = o•oae., 170 Nw" FIGURE 1609.3(1) ULTIMATE DEsiom WIND SPEEDS, Vw, FOR RISK CATEGORY 11 BUILDINGS Wind Speed Ult(mph) 51601M Risk Category 111111t[m Wind Speed ASD(mph) wlwm Exposure Category WM Mean Roof.Height(ft) I 15 Roof Slope (degrees) W25M Module Area(sgft) 20 KA 1 Height Adjustment Factor, A 1 1 16 -27 2 16 44.fi 3 16 -67 P net=KAXj ztP_(net(30)) Pnet';c 1 16 7 2 16 1 �4M1T6 3 16 - 22.6 Maximum Uplift per *fastenerWind Zone 1 272.3 TopT[le" Wood Deck MDuntingSystem 290 Part#K10207-105/107 Laboratory load Testing -Roof attad)ementsw 2 rat Is at: j 44 ,{in O/C max Maximum Uplift per •fastenerWlnd Zone 2 266.2 TopTile- Wood Dedc Mounting5ystem Part 9KI0207-105/107 290 Laboratory Load Testing *Roof attachements w 2 rails at: Uin O/Cmax Maximum Uplift per •fastener Wind Zone 3 276.4 TopTiW" Wood Deck Mounting System 290 Part#K102W-ID5/107 Laboratory load Testing -Roof attachementsw 2 rails at: a inO/Cmax COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC Castillo Engineering DEEIONED TO PEEMITa CASTILLO ENGINEERING SERVICES, LLC COR tl'1BJ[G N25 W. STATE ROAD 434. SURE 111 LONGWOOD, FL 32179 TEL no7)ze9ssTs MMOG9ATES E GSTLLO7FI PE UM REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER S'UNPR �51a'G"'A e f to \C IV. <C 2 90 A E F <4 NG '�777eee u n njj t%%%N LLj m U �rn > ItW > M in U) L-L LuLu OW D_ U Q J LLI U J M a 00 d F EB 1 t 2020 SHEET NAME STRUCTURAL ATTACHMENT DETAILS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER S-02 Q CABLE (N)SOLADECK 600 V, NEMA 3R UL LISTED (N) 125A ENPHASE IQ COMBINER 3 (X4Q-AM1-240-3) (IMTH UPTO (4) 2-POLE BREAKERS AND ENVOY COMMUNICATION GATEWAY! I L—— — — — — —- 1212 ROMEX RUN IN ATTIC (N) JUNCTION BOX 600 V, NEMA 3 UL LISTED L1 L1 L2 L2 L1 L1 L2 L2 L7 L1 Lz Lz G — — — G 012 AWG THWN-2 - RED 12 AWG TH WN-2 - BLACK #6 AWG TH WN-2 GND IN 1" PVC OR EMT CONDUIT RUN 11 ELECTRICAL LINE DIAGRAM E-01 SCALE: NTS ENPHASE I07-60-2-US MICROINVERTERS PV MODULES 120 % RULE - NEC 705.12(D)(2)(3)(b) UTILITY FEED +SOLAR BACKFEED 200A + 50A = 250A BUSS RATING x 120 % 225A x 120% = 270A (N) PV METER (IF REQUIRED BY UTILITY) (N) AC DISCONNECT: 24OV, 60AMP NEMA 3R, UL LISTED LOCKABLE AND NON FUSIBLE (IF REQUIRED BY UTILITY) SOLAR ARRAY 13.40 kW -DC STC) (40) LG335NiC-A5 (335W) MODULES (1) STRING OF 14 MODULES (2) STRINGS OF 13 MODULES NOTE: 1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THE REQUIREMENTS OF THE NEC 2014, AND THOSE SET FORTH BY THE FLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDING MAXIMUM NUMBER OF MODULE STRINGS, MAXIMUM NUMBER OF MODULES PER STRING, MAXIMUM OUTPUT, MODULE MANUFACTURER AND MODEL NUMBER, INVERTER MANUFACTURER AND MODEL NUMBER, AS APPLICABLE. 2. PROVIDE TAP BOX IN COMPLIANCE WITH 312.8 IF PANEL GUTTER SPACE IS INADEQUATE. TO UTILITY GRID Lt L2 N OBI-DIRECTIONAL UT UTILITY METER 0 1-PHASE, 240V L1 L2 N (N) MAIN DISTRIBUTION PANEL, 225A RATED, 240V-- r,1. .1 ME (N) MAIN BREAKER 20OA/2P, 240V I � �Xa YS�] I;] �•l'Bi �� I COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC Castillo Engineering DLSIONFD 10 PITA116 CASTILLO ENGINEERING SERVICES, LLC (MA]B355 2925 W. STATE ROAD 434, SURE 111 LONGWOOD, FL 32779 TEI:14071 H8 M75 ERMOIX TES ECASTILLO-FL PE W5M REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER SUN PRO t 5 90 S A E 'lij e�S€ONA;EN��. W m U >_05 W �co co z LL w W W O FL p 01-0 Q .--! LLI U H J M a GD O 0- fl ZOZO SHEETNAME ELECTRICAL LINE DIAGRAM SHEET SIZE ANSI B 11" X 17" SHEET NUMBER E-01 AC CONDUCTOR AMPACITY CALCULATIONS FROM ROOF TOP SOLADECK TO LOAD CENTER MODULE MANUFACTURER LG MODULE MODEL _ LG335N 1 C-VS INVERTER MANUFACTURER ENPHAGE INVERTER. MODEL _ ENPHAGE IC) 7 MODU LE6/8RANCH CIRCUIT. I _ 1 3 MODULEB(a RANCH CIRCUIT 2 13 MODULES/BRANCH 6IRCUIT.31 14 TOTAL ARSE AY.POWER IKW) 13.40 SYBTEM. AC VOLTAGE'. 240V 1-PHASE DESIGN TEMPERATURE MIN. AMBIENT TEMP. OF 32 MAX. AMBIENT TEMP'. OF 1.17 CALCULATED MAX. VOC 4_4 CALCULATED MIN VMP 215T CONDUIT, FILL NUMBER OF CONDUITS 1 1. AMPACITY CALCULTIONB AC CONDUCTOR AMPACITY CALCULATIONS: FROM AC COMBINER BOX TO MSP MODULE PROPERTIEGI _ VDU _ 41 IBC 10.49 VMPP 34.1 JIMP I 9.63 TC VDU 1 -0.2796/°C ITO VNP I -D.36%/:°C PMP 1 335.0 NCCT 45 °C INVERTER. PROPERTIES OUTPUT VOLTAGE 240 L-L I -PH MAX INPUT, DO VOLTAGE 48 VDC OPERATING RANGE 1 6 - 4a VDC MPPT VOLTAGE RANGE 27 - 37. VDC START VOLTAGE 22 VDC MAX INPUT POWER 350 Woo CONTINUOUS AC POWER 240 VA 1.26 X 913 DC AMBIENT TEMP CONDUIT FILL DEBATED MAXIMUM CIRCUIT CIRCUIT MAX AMPS AWG MAX AMPS AMPACITY TEMP OF DERATE FILL DERATE AMPACITY EIREAKER CIRCUIT 1 13.0 16..3 #12 30 95 0696 6 0.8 23.D4 20 A CIRCUIT 2 13.0 6.,3 #12 30 95 0.96 6- 0.8 23.C4 - 20' A CIRCUIT 3 14.0 17`5 #12 30 95. 0.96 6. 0.8 23,04 20.A AD COMRENER 4ELO SO..O #6. 75 95 3. 1 PANES. OUTPUT 0.96 72 SO A MAXIMUM CIRCUIT VOLTAGE._DRUP,. 2% _ VOLTAGE DROP' CALCU LATIONC CIRCUIT AWa CIRCULAR MILLS I V MAX I LENGTH CIRCUIT 1 #12, 6530 13.0 240 NEW931peET CIRCUIT 2' #12 6530 13.0 240 9'3 FEDT CIRCUIT 3 #12- 6530 14.0 240 H,7 FEE COMBINER PANEL OUTPUT #6 26240 40.13 240122 FEET WIRE SIZES A POTENTIALLY I SI S) THWN-2 CDMPUEB WITH NEC I ERMOCRATES CASTILLO PE# 52590 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBC 107. COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC ELECTRICAL NOTES 1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. THE TERMINALS ARE RATED FOR 75 DEGREE C. 3. THE WIRES ARE SIZED ACCORDING TO NEC 110.14. 4. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 5. WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 6. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 7. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 8. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 9. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 10. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY -IN LUG. a -o 11. THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE . -33 '. 12. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. '! 13. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 14. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. 15. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D). 16. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). ENPHASE IQ7-60-2-US MICROINVERTER Input Data (DC) Recommended Input Power (STC) 235-35OW + Maximum Input DC Voltage 48V Peak Power Tracking Voltage 27V-37V Operating Range 16VABV Min. / Max. Start Voltage 22V / 48V Max DC Short Circuit Current 15A Output Data (AC) Maximum Output Power 240W Nominal Output Current 1.0A Nominal Voltage / Range 240V/211-264V Nominal Frequency / Range 60 Hz Extended Frequency / Range 47-68 Hz Power Factor at rated power 1.0 Maximum unit per 20A Branch Circuit 16 (240 VAC) Castillo Engineering DESIGNED TO PERMIT. CASTILLO ENGINEERING SERVICES, LLC CAR02,U,5 2925 W. STATE ROAD 4M, SURE 111 LONGWOOD. FL 32779 T (407)2842575 FANARNTE 9 E CA9TILL0 - FL GE N590 REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER SU,NPR- &52590 Iz 41 W C 00 LU v M LLLL LU LU O LU ry n. U Q J U � J M � Q 000 Eg 1 t 202f SHEET NAME WIRING CALCULATIONS SHEET SIZE ANSI B 111T X 17" SHEET NUMBER E-02 ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION (PER CODE: NEC690.54) AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: NEC 690.17(E), CB LABEL LOCATION: LABEL LOCATION: CONDUIT, COMBINER BOX POINT OF INTERCONNECTION (PER CODE: NEC 705.12(D)(7)) (PER CODE: NEC690.31(G)(3)(4) & NEC 690.13(G)(4) [Not required if panelboard is rated not less than sum of ampere ratings of all overwrrent devices supplying it] LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: NEC 705.12(D)(4)) ADHESIVE FASTENED SIGNS: THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING]. • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.31 DATA PER PANEL LABEL LOCATION: COMBINER BOX (PER CODE: NEC690.52) INTERCONNECTION (PER CODE: NEC690.56(C)) COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC Castillo Engineering D[SIO NFD i0 Ili NIT. CASTILLO ENGINEERING SERVICES, LLC MA.28-5 2925 W. STATE ROAD 4M, SURE 111 LONGWOOD. FL 32779 tpl (407) ]as.415 FRMJCRAIESEGSfRIA-RpER59J REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER SVNPR- Signature WM Seal ````gnoL ee NTI4�0.,. Fes' i i O g0 :4r R 4 P.'�% % 11110100 W It co 0 U� U O LU W D-C) Q J W U J ce) a � O EL 1 � 2029 SHEET NAME SYSTEM LABELING SHEET SIZE ANSI B 11" X 17" SHEETNUMBER E-03 LG335N1C-V5 335W The LG NeONO 2 is LG's best selling solar module, and is one of the powerful and versatile modules on the market today. Featuring LG Technology, the LG NeON° 2 increases power output New u include an extended performance warranty from 86% to 89. give customers higher performance and reliability. DVE C&S Cc L MPan.m A337Madein R� (USAF mm FTVMI30� Enhanced Performance warm I LG NeON® 2 has an enhanced performance warranty. After 25 years, LG NeON®2 is guar- anteed to perform at minimum 89.6%of initial performance. AEnhanced Product warranty LG has extended the warranty of the NeONO 2 l. to 25 years, which is among the top of industry standards. Better Performance on a Sunny Day t Roof Aesthetics - �� LG NeONO 2 now performs better on sunny days, thanks to Its improved temperature � LG NeONo 2 has been designed with aesthetic in mind using thinner wires that appear all black at a coefficient distance. The LG NeON© 2 can increase the aesthetic value of your home with a more modem design. About LG Electronic IGEkmuJ5k49M6L kNn Melemmic Pa9aNFJedane^n4tmu1em6.ara19WwWmhmtlm°punaW ystmm Tl'4cmipvry6nemlwFeE ® �� maEW mcp/»vmrexeaNpa•+mM 1985.ngv¢d6ElGreayTvm egaMONNe2NmyKln,la,amkeymNmm,yDingpMn M}0141G SOW pa ftrelea EIca AFM00%•vkam Wm6, aMkcaw mMN¢Y,3} -d lln M TD(p•.8ut L1wN. xeON)}koNR NdNn 06a]y wm W'I,[vNaAWPIM'M}0133015 aMMIQMvAA atnl(lkalosNpatlbmnymin LLeplu hln,ry. LG NeON®2 LG335N1C-V5 General Data I CN Rgntln (IAater6l /T5Tx1 l4mmyEmOro / N-ry W i 4i Meiar l6 Ire6cma9m.dai 6or4D,(6.1a) mm6erarM46an t2(q i Noddeooaiaw(L.W.H) 1,6a6nvn.lA16mm.40mm VMfit 17..1 L9 Dla4StatlNO Tmµe6wmwM,sa fmtL,9 G:la6aagcaw) wNm InmRlM+mdan A,[AMJALmiNun Iw.nnew(Flou De,w) O'68mM,3epapgp3ef I rdAes(ImTM1) I.000mmt2EA Caveatm(Type/Moire,) W4/MC Certifications and Warranty ' 4.IlraawDs I IK 612151/-t 1/zml 6=016.13K 61T30. ur03 609CO1.6O14001.605[NI oLsnste9ol,wLmE IS IL MGrtra,mslm Tert W61701:3012S iy6 INmmacwroriunTost IEC 62116:3013 (Nadal-Re0. hman¢- TSEel(U.1703) Ir eaaGnq om<001.794tRCIUSmc1703j I$aAMowb:IAWYESWenaaty _ 25T i Scrim Module WmutWa mty IYVWartauy -nr.mr•+�99x })Arm.,c>d.:assx.weyaa�aeamcrs}6T.„, Tenperature Ch uracteristia INEGO" - I Z ] 42.3 I P4mr f5J'cl- -036 IIQ [xrq am •IdAOrnlEak+lANWeOvaE9Tmp,aMjNtlapaDo WfiI.M6ealaar0�•>m'[ WW s¢Nf M49Pm,•nAN 13 Electrical Properties NM Mom 1g35NtC-ys I 1 M4,vem P.Mv(Pna7 [wl 3 MW UM a 319 " MwOe2n784 IgenG lVaDDNVdmge(Voc7 M xS isxrtue:eunmu(Isl A] a4 US 1-V Curves 00 'Q0 ron 30D 4Da ® LG firs amNmn sda.ewenoM:m 200o MLMmkgtx Ofe4 Good I4nIm5trGnfiW69 —19'saamm Madeln . 6m.e�9mUSA=wA.m� tle[mal Yla erGes SAC• Mn41 1G335NiC-VS ) MUNmn Poser(Rw) lWf 335 I MPPVdM9P(9mpp) M 3Q1 Mw Ommt MSP) IA7 M3 It-OlmGvdMNt }tl�,f Ml M 41.0 19vtdoJeCuemtltr.lSlj IA] 1449 I NOAtla FIMvq DL] l9b I POmTObam Ix] o•a •SiC(ysW4TenrudtbnjYM4om I WO Wlm•,filumpvatwe}5'4AM IS O eatin Conditions OLaaLgTae Y 43-•90 lMo a [V 1.9001L) 10]II(IEC) f Mavo.n3woF,ranaw A 30 I Netla9mlTeu Wd(Rort) rpgpai SA00/113 IMdavolYalmd aI INI 4A00im •rm we-my�mexsakpEawnsl Packs inq Configuration INinbmaL6L9eaf�PaBtt [EA7 }s IMmdnaw W40ftMG wm [EA] 6s0 IPeda Box Om.isv¢lLiW..) 1aWxl.121 21 I NDE, i em6 we96t 1 tki] 1 4" Dimensions (mm/Inch) Iu :✓ ] Iraaa:cear.Mm,m.awp.4,aa�.NemldwuwwD ❑ Lra3wlc-vs-l4v.,a1 020191G E4fppJ¢P➢dgNsleserKQ ❑ Castillo Engineering DESIGNED TO PERMIT• CASTILLO ENGINEERING SERVICES, LLC COAP}83f5 2925 W. STATE ROAD 434, SUITE ill LONGWOOD. FL 32179 TEL:(407)2S"Z76 EflMO(MTES E.oA$TIaO-FLPE 5Q590 REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER S'UNPR OR %%% !Sign a S N 25 AT OF eeeelntta LU m U �00 LU It M y, LL U I.I.) IY O d U Q LcU U F.: C fn J cr d coO FEB 1Ilb SHEETNAME MODULE DATA SHEET SHEET SIZE ANSI B 1111 X 171, SHEET NUMBER DS-01 ® LG Life's Goad Oct 18, 2019 To: LG Solar Installers RE: Approval letter to use the 2 Rail Mounting Dear LG Solar Installers, LG Electronics U.S.A., Inc. 1000 Sylvan Avenue Englewood Cliffs, N] 07632 201.816.2000 This letter hereby states that LG supports and provides warranty for the referenced LG modules which have been mounted by the 2 Rail Mounting system refer to the installation manual Fig.2 for the test load of 6000 Pa downforce and 5400 Pa uplift under the test conditions based on IEC 61215:2005. astallation Seen Picture System Dow force pOff 2 Rail Mounting 6000 Pa 5400 Pa ' Under the test condition based on IEC 61215-2:2016, the test load may be different. The following LG Solar modules are approved for warranty: f001;Io'deelfl mberA 1 iLrGl111odeel1Nambe'r7 LGxxxN1C-V5 LGxxxNIK-V5 LGxxx 1C-VS I LGxxxQIK-V5 ?OOmm IOODtal Our warranty provides all the terms and conditions underlying our obligations and the warranty. Although this Letter serves as an authorization to employ the 2 Rail Mounting System, the original warranty terms for the modules would be rescinded in the event of: - Misuse, abuse, neglect, or accident such as micro crack to the cells or glass damages; - Alteration, improper installation or application; - Non -observation of LG Electronics' installation and maintenance instructions; - Repair or modifications by someone other than an approved an approved technician of LG; - Power failure surges, lightening, fire or other event outside LG Electronics' control; - Defect or Power drop due to the incline load; If you have any questions or concerns in regards to this letter of authorization, please feel free to call your LG Electronics Sales Manager. LG Electronics U.S.A. Inc. North America Solar Business Team 1000 Sylvan Avenue Englewood Cliffs, NJ 07632 Castillo AeA Engineering DESIGNED TO PEAMIi• CASTILLO ENGINEERING SERVICES, LLC CAFNWM5 2925 W. STATE ROAD 434. SUITE I II LONGWOOD, FL 32779 '11.(On M& 75 ER$=,,ATESEC 1U.O-FLPEW59] REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER SUNPR eree SF. 0 0. S T P.• � W C 00 W m 0 to LL f/) Z W OW IV IL U :ED Q J cW C U) J Cr) d 000 a.. 1 1 Mo SHEET NAME TEST LETTER DATA SHEET SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-01.1 Data Sheet Enphase Microinverters Region: US Enphase IQ7and IQ7+ Microinverters UL To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready Enphase IQ 7 Micro"' and Enphase IQ 7+ Micro"' dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate seamlessly with the Enphase IQ Envoy'", Enphase Q Aggregator'", Enphase IQ Batteryre, and the Enphase Enlighten"' monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install Lightweight and simple Faster Installation with improved, Iightertwo-wire cabling Built -In rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable Optimized for high powered 60-cell and 72-cell* modules More than a million hours of testing Class II double -insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) *The IQ 7+ Micro Is required to support 72-cell modules. EN PHASE. Enphase IQ 7 and IQ 7+ Microinverters I Commonly used module pairings' Module compatibility 235 W-350 W+ 60-cell PV modules only 235 W-440 W+ 60-cell and 72-cell PV modules Maximum input DC voltage 48V 60V Peak power tracking voltage _ _ 27V-37V 27V-45V Operating range 16V-48V 16V-60V _ ----- ---._--__-��--- Min/Max start voltage---------- 22V/48V 22V/60V Nominal (L-L)voltagelfangex 24OV/ 208V/ — 24OV/ 208V/ 211-264 V 183-229 V 211.264 V _ 183-229 V J Maximum continuous output current 1.0A 1.15A 1.21A 1.39A Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68Hz Power factor setting �_ 1.0 1.0' W _�� Powerfactor(adiustable) 0.7 leadino... 0.7 laaaino 0.7 leadinu... 0.7 MECHANICAL DATA IQ 7 Microinverter I Ambient temperature range Relative humidity range -40^C to+65aC. _ 4%to 100%(condensing) ' Conneclortype MC4(or Amphenal H4 UTx with additional Q-DCC-5adapter) u __ Dimensions(WxHxD) _. r _.__ Weight _ Cooling 212 mm x 175 mm x 30.2 Min (without bracket) 1.OB kg (2.381bs) Natural convection - No fans Approved for wet locations _ Yes Pollution degree PD3 Enclosure Environmental category UV exposure rating Classll double -insulated, corrosion resistant polymeric enclosure NEMA Type 6/outdoor FEATURES 1 Onmmunirallrm - Pnwnr l Inc Cemmunicatlnn(PI M I Both options require Installation of an Enphase IQ Envoy. LDisconnecting means -- The AC and DC connectors have been evaluated and approved by ULfor use as the load -break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1. UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when Installed according manufacturer's Instructions. 1.No enforced DC/AC ratio. See the compatibility calculator at htt.,-/12�/.npha= o�=/xypport/module 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Umhs may vary. Refer to local requirements to define the number of mlcminverters per branch In your area Castillo Engineering oe51ouro To rrLnrt• CASTILLO ENGINEERING SERVICES, LLC ODA425N5 2925 W. STATE ROAD 4M, SUITE ill LONGWOOD. FL 32779 TEL:(07)2NZ575 EPM TEaa(ASnLLO-FL PE 52590 REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER 5 UN P R: F NO 2590 ATE &�`.� �N1 tt1111 ����� 00 � C >> tT 11J > V (7 (n LJL C OW ry a v :E n Q .J We U H C 0) c+) a 000 F EB 1 1 2020 SHEET NAME INVERTER DATA SHEET To learn more about Enphase offerings, visit enphase.com v EN PH AS E. SHEET SIZE 02018 Enphase Energy.All rightsreserved. All trademarks or brands used are the property of Enphose Energy,Ina ANSI B 2018-02-08 11" X 17" SHEET NUMBER DS-02 Data Sheet Enphase Networking Enphase IQ Combiner 3 (X-IQ-AM1-240-3) U� LISTED To learn more about Enphase offerings, visit enphase.com The Enphase IQ Combiner 3- with Enphase IQ Envoy' consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre -wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Smart • Includes IQ Envoy for communication and control • Flexible networking supports Wi-Fi, Ethernet, or cellular Optional AC receptacle available for PLC bridge Provides production metering and optional consumption monitoring Simple • Reduced size from previous combiner • Centered mounting brackets support single stud mounting • Supports back and side conduit entry • Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80 A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year warranty UL listed v ENPHASE. Enphase IQ Combiner 3 MODELNUMBER IIQ Combiner 3 X-IQ-AMl-240-3 IQ Combiner with Enphase 10 Envoy" printed circuit board for Integrated revenue grade PV production metering (ANSI C12.20+/-0.6%) and optional -consumption monitoring (+/-2.5%). ACCESSORIES and REPLACEMENT PARTS (not Included, order separately) Enphase Mobile Connect- - I CELLMODEM-03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01(3G/5-year data, plan) microinverters.(Available in the US,Canada,Mexico, Puerto Rico, and the US Virgin, Islands, Consumption Monitoring* Of CT-200-SPLIT Split core current transformers enable whole home consumption metering (+/-2.5%). Circuit Breakers Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. BRK-10A-2-240 Circuit breaker, 2 pole, IOA, Eaton BR210 BRK-15A-2 Circuit breaker, 2 pole, 15A, Eaton BR215 BRK-20A-2P-2P-240 --- Circuit breaker, 2 pole, 20A, Eaton BR22020 20 EPLC-01 Power line carrier (communication bridge pair), quantity 2 XA-PLUG-120-3 Accessory receptacle for Power Line Carrier In IQ Combiner 3(required for EPLC-01) ___� XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner System voltage 120/240 VAC, 60 Hz IEaton BRseries busbar rating 125A Max. continuous current rating (output to grid) 65 A - Max.fuse/circuit rating (output) 90A --� Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG) breakers only (not Included) Max. continuous current rating(Input from PV) 64A Max. total branch circuit breaker rating (input) BOA of distributed generation/ 90A with IQ Envoy breaker included Production Metering CT 200 A solid core pre-instelledand wired to I Envoy _ MECHANICAL DATA IOimensions (WxHxD) 49.5 x 37.5 x 16.8 cm (19.5' x 14.75' x 6.63')..Height is 21.06' (53.5 cm with mounting brackets). Weight 7.5 kg (16.5lbs) Ambient temperature range J` -40D Cto+46D C(.40D to 115-F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor,NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors • 60 A breaker branch input: 4to 1/0 AWG copper conductors • Melnluacombinedoutout: 10to2/0AWGwonerconductom Integrated Wi-Fi 802.11b/g/n Ethernet Optional,802.3. Cat5E(or Cat 6) UTP Ethernet cable (not included) Cellular Optional, CELLMODEM-01 (3G)-or CELLMODEM-03 (4G) or CELLMODEM-MI (4G based LTE-M) _(not included) COMPLIANCE Compliance, Combiner UL 1741 CAN/CSA C22.2 No. 107.1 47 CFR, Part 15, Class B, ICES 003 --_ --_ _ Production metering: ANSI C1220 accuracy class 0.5(PV production) Compliance, IQ Envoy UL 60601-1/CANCSA 22.2 No. 61010-1 Is required for Enphase Storage Systems. To learn more about Enphase offerings, visit enphase.com 02018.13hase Energy. All rights reserved. All trademarkR or brands In tNs document are registered by their respective owner. v ENPHASE. Castillo Engineering AEw Drr10NrD TO PERMIT% CASTILLO ENGINEERING SERVICES, LLC ODA42eaa5 121 W. STATE ROAD 434, SURE 111 LONGWOOD, FL 32779 T¢:(4on2e>ss1s raMouuTas a cAsnuo. rL Pa usso REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER SU N PR40- fW�7i P1P', E OF '.O R % ID W M 0 CO LJL LU O ry W dU Q J W U c � J M a o0 O 0- SHEET NAME COMBINER BOX DATA SHEET SHEET SIZE ANSI B 1111 X 1711 SHEET NUMBER DS-03 CASTILLO ENGINEERING '" SERVICES, LLC :: UNIRAC :o:UNIRAC 1 / , / / AlUe 2925W.SURE111AD434, 1eUP(7MPMlY p Hlm Gft011PCOMPPNS $DnE 111 LOryGW00D, FL 32]]9 SolarMount Technical Datasheet Pub 100602-111d V1.0 June 2010 Connection Hardware r SolarMount Module .................................................................. BottomUp Module Clip.................................................................................................1 MidClamp....................................................................................................................2 EndClamp....................................................................................................................2 SolarMount Beam Connection Hardware......................................................................3 L-Foot ...........................................................................................................................3 SolarMountBeams..........................................................................................................4 SolarMount Module Connection Hardware SolarMount Bottom Up Module Clip Part No. 321001, 321002 Be Dimensions specified In inches unless noted • Bottom Up Clip material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear Anodized • Bottom Up Clip weight: -0.031 lbs (14g) • Allowable and design loads are valid when components are assembled with SolarMount sedes beams according to authorized UNIRAC documents • Assemble with one'/: -20 ASTM F593 bolt, one'/.•-20 ASTM F594 serrated flange nut, and one Y.• flat washer • Use anti -seize and tighten to 10 ft-lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory • Module edge must be fully supported by the beam * NOTE ON WASHER: Install washer on bolt head side of assembly. DO NOT install washer under serrated flange nut erage mate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Load Ibs (N) Resistance Factor, m MTension,Y+ j1566967) 686(3052) 2.28 1038(4615) 0.662 019) 329(1463) 3A3 497(2213) 0.441 92) 27 (119) 2.44 41 (181) 0.619 SolarMount Mid Clamp Part No. 320008, 320009. 320019, 320020, 320021, 320084,320085,320086,320087,320120,320122 sm ourpsu— — &'M'Fp1 L{'LUB Yf L-►X Dimensions specified in Inches unless noted • Mid clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • Mid clamp weight: 0.050 lbs (23g) • Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single mid clamp assembly when used with a SolarMount series beam to retain a module In the direction Indicated • Assemble mid clamp with one Unirac /V-20 T-bolt and one %/ 20 ASTM F594 serrated flange nut • Use anti -seize and tighten to 10 ft-lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Load lbs (N) Resistance Factor, 0 Tension, Y+ 2020 (8987) 891 (3963) 2.27 1348 (5994) 0.667 Transverse, Z3 520 (2313) 229 (1017) 2.27 346 (1539) 0.665 Sliding, Xt 1194 (5312) 490 (2179) 2.44 741 (3295) 0.620 SolarMount End Clamp Part No. 320002, 320003, 320004. 3200D5, 320006, 320012,320013,320014,320015,320016,320017, 320079,320080,320081,320082,320083,320117, 320118,320123,320124,320173,320185,320220, I—► X vs ,mmsw neon YInH mwne w Dimensions speci ed • End clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi. Yield: 35 ksl • Finish: Clear or Dark Anodized • End clamp weight: varies based on height: -0.058 lbs (26g) • Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single end clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble with one Unirac%--20 T-bolt and one %. -20 ASTM F594 serrated flange nut • Use anti -seize and tighten to 10 ft-lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory • Modules must be installed at least 1.5In from either end of a beam Direction Applied LoadF1321(6876) lbs Allowable Load lbs (N) Safety Factor, FS Design Loads lbs (N) Resistance Factor, m Tension, Y+ 529(2352) 250 800 (3557) 0.605 Transverse, Zt 14 (61) 4.58 21 (92) 0.330Sliding, Xt 52 (231) 2.72 79 (349) 0.555 PROJECT INSTALLER SUNPR �••'' C E N r. <� C •' No g0 / TE U Z } 00 ¢0) W co Q U) U W OIL LLJ Q� U~ co J M F- otf Oa 000 21Pt0 F EB 1 i SHEETNAME RAIL DATA SHEET SHEET SIZE ANSI B 11"X 17" SHEET NUMBER DS-04 •1A AE The TopTileT" Mount Advantage ./ No more lifting roof tiles, broken tiles or finding rafters. ./ Mounting stanchion can be mounted on a the ridge independent of rafter position. Hand bendable flashing and EPDM Rubber Boot for easy fit and superior leak protection. ./ High -Velocity Hurricane Zone Approved - Passed TAS 100 (a) Wind -Driven Rain Test Key Features of TopTileTMMount System I I I E. Rafter Mounting System: (K70206-005/007) These Stanchion Mounts can be used for direct rafter installation. Flat tiles allow lateral flexibility to locate the rafter. Wood Deck Mounting System: (K10207-105/107) These Tripod Mounts are used for curved tiles or flat files to mount directly into roof decking without removing tiles. Concrete Deck Mounting System: (K70290-005/007) These Stanchion Mounts can be mounted directly to a flat concrete surface with a customer supplied expansion anchor. Technical Data Application Tile Roof Material High grade aluminum, 304 stainless steel hardware Finish Clear anodized Flashing Size 9.00 x 12.50 x 0.03 inch Stanchion Height 5" and 7"; 6" and 8" height can be achieved with 1"spacer Roof Attachment Rafter (wood) , decking (wood and concrete) Structural Integrity IBC and IRC compliant Warranty 20 years SunModo, Corp. Vancouver, WA., USA • www.sunmodo.com • 360.844.0048 • info@sunmodo.com Castillo Engineering o ESIGMLo TO PIRMn. CASTILLO ENGINEERING SERVICES, LLC WA*28 5 121 W. STATE ROAD 434, SUITE I1 LONGWOOD, FL 32]]B i '(407)) 3Zn FAMOCMTES E CASiILLO - F L PE 52592 REVISIONS DESCRIPTION DATE REV PROJECT INSTALLER S4JNPROO ttt Nq�2590 ATE E 40 r o W Z w W IX W J Q 11. Co ao C m to -1 Z LL O ui IL Q J U in DO co 00O IL ATTACHMENT DATA SHEET SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-05