HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: WYNNE THE GRAN CARLTON IMPACT
BuilderName: WYNNE BUILDING COPR.
Street: wv\ksr\
Permit Office: ST.LUCIECOUNTY
City, State, Zip: FT. PIERCE, FL,
PernitNumber:
Owner: WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
Designt-ocation: FL, Fort Pierce
County: St. Lucie (Florida Crimate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sgft.)
Insulation Area
2. Single family ormultiple family Single-family
a. Concrete Block- Int lnsul, Exterior
R=4.1 1250.00 fi-
b. Frame -Wood, Adjacent
R=11.0 192.00ft-
3. Number of units, if multiple family 1
c. N/A
R= ft'
4. Number of Bedrooms 2
d.N/A
R= ft-
10.Ceiling Types (1476.0 sqft.)
Insulation Area
5. Is thisaworsl case? Yes
a. UnderAttic(Vented)
R=30.0 1446.00ft=
6. Conditioned floorarea above grade(ft� 1446
b. Knee Wall (Vented)
-R=19.0 30.00 fN
Conditioned Floorareabelowgrade(ft� 0
c. N/A
R= ft'
11. Ducts
R ft'
7. Windows(141.3 sgfL) Description Area
a. Sup: Attic, Rat: Attic, AH: Attic
6 175
a. U-Factor. Sgl, U=1.04 101.25 ft'
SHGC: SHGC=029
b. U-Factor: Sgl, U=1.11 40.00 ft-
12• Cooling systems
kBtulhr Efficiency
SHGC: SHGC=027
a. Central Unit
34.8 SEER:15.00
c. U-Factor. N/A ft'
SHGC:
13. Heating systems
kBtulhr Efficiency
d. U-Factor: WA ft'
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted AverageOverhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.284
14. Hot water systems
a. Electric
Cap:40 gallons _
8. FloorTypes (1446.5 sgft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft'
b. Conservation features
b. WA R= ft'
None
c. NIA R= ft'
15. Credits
Pstat
Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.50
PASS
Total Baseline Loads: 48.09
I hereby certify that the plans and specifications covered by
Review of the plans and
'EMSTg7
this calculation are in compliance with the Florida Energy
specifications covered by this
Oki
Code.
calculation indicates compliance
y ��0% M
with the Florida Energy Code.
PREPARED BY: _I ._II S!`!(P_�1_U'[a �9.1�K(rJ
Before construction is completed
DATE: 1-9-20
this building will be inspected for
compliance with Section 553.908
, e
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
,!1
with the Florida Energy Cod
cOD.yy� C4
OWNER/A� T
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH150 (R402.4.1.2).
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
118120204:18 PM EnergyGaugeO USA 6.0.02(Rev:1)- FlaRes2017 FBC 6th Edition (2017)ConBOn o re Paget of
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE GRAND CARLT Bedrooms: 2
Address Type:
StreetAddress
BulldingType: User ConditionedArea: 1446
Lot#
OwherName: WYNNE BUILDING CROP TotalSlorles: 1
Block/Subdivision:
#of Units: 1 Worst Case: Yes
PlatBook:
BuilderName:. WYNNE BUILDING COPR. RotateAngle: 180
Street:
Permit Office: ST. LUCIE COUNTY CrossVentilation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY 'Whole House Fan: No
City, State, Zip:
FT. PIERCE,
FamilyTyps: Single-family
FL,
NewIE)dsting: New (From Plans)
Comment:
CLIMATE .
/ - Design Temp
Int Design Temp Heating
Design DailyTemp
V Designt-ocation TMYSite 97.5% 2.5%
Winter
Summer DegreeDays Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70-
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1446 11568
SPACES
Number Name .Area Volume Kitchen Occupants
Bedrooms.
Infli ID Finished Cooled
Heated
1 BEDROOM 301 2408 No 0
1
1 Yes
Yes
Yes
2 WIC 63 504 No 0
1 No
Yes
Yes
3 M.BATH 56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN 192 1536 Yes 0
1 No
Yes
Yes
5 BATH 45 360 No 0
1 Yes
Yes
Yes
6 BEDROOM 2 204 1632 No 0
1
1 Yes
Yes
Yes
7 ENTRY 55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY 42 336 No 0
1 Yes
Yes
Yes
9 GREATIDINING 488 3904 No 0
1 Yes
Yes
Yes
FLOORS
# FloorType Space Perimeter PerimeterR-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation BEDROOM 52 it 0
301 ft'
0 1
0
2 Slab -On -Grade Edge Insulation WIC 1ft 0
63 ft'
___
0 1
0
3 Slab -On -Grade Edge Insulation M.BATH 8ft 0
56 ft'
____
0 1
0
4 Slab -On -Grade Edge Insulation KITCHEN tft 0
192 ft'
____
0 1
0
5 Slab-On-GradeEdgelnsulalion BATH 5 ft 0
45 ft'
_—_
0 1
0
6 Slab -On -Grade Edge Insulation BEDROOM 32.2ft 0
203.5ft
____
0 1
0
7 Slab -On -Grade Edge Insulation ENTRY 7ft 0
55 It,
----
0 1
0,
118120204:18 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition,(2017) Compliant Software Page 2of5
FORM R405-2017 INF'U 15UMMAKY GHtGKLI51 KCPUKI
FLOORS
# FloorType Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood Carpet
8 Slab -On -Grade Edge Insulation LAUNDRY Eft
0
42 ft2
----
0
1
0
9SIab-On-Grade Edgelnsulation GREAT/DINING 46ft 0
488 ft2
----
0
1
0
ROOF
Roof
Gable
Roof
Red
Solar
SA Emitt
Emift Deck
Pilch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 GableorShed Metal 1524111
240 ft'
Light
N
0.6
No 0.9
No ..0
18.4
ATTIC
/
V
# Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1446 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 UnderAttic(Vented) BEDROOM
30
Blown
301 ft'
0.1
Wood
_ 2 UnderAttic(Vented) WIC
30
Blown
63 ft'
0.1
Wood
3 UnderAttic(Vented) M.BATH
30
Blown
56 ft2
0.1
Wood
_ 4 UnderAttic(Vented) KITCHEN
30
Blown
192 ft'
0.1
Wood
5 UnderAttic(Vented) BATH
30
Blown
4511'
0.1
Wood
6 UnderAttic(Vented) BEDROOM
30
Blown
204W
0.1
Wood
7 UnderAttic(Vented) ENTRY
30
Blown
55 ft'
0.1
Wood
8 UnderAttic(Vented) LAUNDRY
30
Blown
42W
0.1
Wood
9 UnderAttic(Vented) GREAT/DINING
30
Blown
488 ft'
0.1
Wood
10 Knee Wall (Vented) GREAT/DINING
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar
Below
_ 1 NE=>SW Exterior Concrete Block- IntlnsulBEDROOM
4.1 10
0 8
0
80.0 ft'
0
0
0.4
0
_ 2 SW=>NE Exterior Concrete Block- Int lnsul BEDROOM
4.1 28
0 8
0
224.0W
0
0
0.4
0
_ 3 NW=>SE Exterior Concrete Block- Int lnsul BEDROOM
4.1 14
0 8
0
112.Oft2
0
0
0.4
0
_ 4 SW=>NE Exterior Concrete Block - Intlnsul M.BATH
4.1 8
0 6
0
64.0 ft'
0
0
0.4
0
_ 5 NE=>SW Exterior Concrete Block - Intlnsul BATH
4.1 5
0 8
0
40.0 ft'
0
0
0.4
0
6 NE=>SW Exterior Concrete Block- Int lnsuBEDROOM 2
4.1 16
0 8
0
128.0 ft'
0
0
0.4
0
7 SE=>NW Exterior Concrete Block- InllnsuBEDROOM 2
4.1 10
0 8
0
80.0 ft'
0
0
0.4
0
8 S=>N Exterior Concrete Block- Int lnsuBEDROOM 2
4.1 4
3 8
0
34.0 ft'
0
0
0.4
0
_ 9 SW=>NE Exterior Concrete Block- Int lnsuBEDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.4
0
10 SE=>NW Exterior Concrete Block-Intlnsul ENTRY
4.1 6
0 8
0
48.0 ft'
0
0
0.4
0
11 SW=>NE Exterior Concrete Block- Intlnsul ENTRY
4.1 1
0 8
0
8.0 ft'
0
0
0.4
0
12 SW=>NE Exterior Concrete Block-Intlnsul LAUNDRY
4.1 6
0 8
0
48.0 ft'
0
0
0.4
0
13 NE=>SW Exterior Concrete Block -Int lnsuGREAT/DINT
4.1 26
0 8
0
208.0 ft2
0
0
0.4
0
14 NW=>SE Exterior Concrete Block -Int lnsuGREAT/DINT
4.1 20
0 8
0
160.0 ft'
0
0
0.4
0
1/8120204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3of5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space .Cavity Width
Height Sheathing Framing Solar Below
15 N=>S Garage Frame -Wood
KITCHEN 11 24 8
192.0 ft' 0.23 0.4
0
DOORS
# Ornt
DoorType
Space. Storms
U-Value Width Height
Ft In Ft In
Area
1 SE=>NW
Insulated
ENTRY None
.39 3 1 6 8
20.6It-
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
# Omt ID Frame
Panes"
NFRC U-Factor SHGC Imp
Overhang
Area Depth Separation IntShade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW 13 Metal
5 NW=>SE14 Metal
Low-ESingle
Low-ESingle
Low-ESingle
Law-ESingle
Low-ESingle
Yes 1.04 0.29 Y
Yes 1.04 0.29 Y
Yes 1.04 0:29 Y
Yes 1.04 0.29 Y
Yes 1.11 0.27 Y
32.9 ft- 1 ft 0 in 1 ft 5 in Drapeslblinds
6.9 ft- 1 ft 0 in 1 ft 5 in None
24.0 ft- 6 ft 0 in 1 ft5 in None
37.5 ft2 1 ft 0 in 1 ft 5 in. None
40.0 ft2 8ft0in Ift5In Drapestblinds
Exterior5
None
None
None
Extedor5
GARAGE
# FloorArea
- CeilingArea Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1 315 ft'
315 ft2 24ft
8ft 11
INFILTRATION
# Scope Method
SLA CFM 50 ELA EgLA ACH ACH 60'
1 Wholehouse ProposedACH(50)
.000356 1349.6 74.09 139.34 .1233 7
HEATING SYSTEM
# System Type
Subtype Speed Efficiency
Capacity Block
Ducts
1 Electric Heat Pump/
Split Single HSPF:8.5
34.8 kBtuihr 1
sys#1
COOLING SYSTEM
# System Type
Subtype Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1 CentralUnitf
Split Single SEER: 15
34.8 kBtu/hr dm 018 1
sys#1
HOT WATER SYSTEM
# System Type
SubTpe
Location EF Cap
Use SetPnt Conservation
1 Electric
None
Garage 0.97 40gal 60.9gaj 120deg None
1/8120204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page of 5.
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # CompanyName
System
Model#
CollectorModel# Area Volume
FEF
None None
ft2
DUCTS
/ —Supply—
—Return—
Air
:CFM25
CFM25
HVAC#
V # Location R-Value
Area
Location
Area
LeakageType
Handler
TOT
OUT ON
RLF
Heat Cool
1 Attic 6
175 ft2
Attic
65 ft2
DefaullLeakage
Attic
(Default) c(Default) c
1 1
TEMPERATURES
ProgramablreOTC,Ihermostatr: Y
Ceiling Fans:
Venting
rf�'
Apr
I
IMay
fr TI
t`
4
trX
r
cc
[ ]Jan [ ].Feb
[X]Mar
[x]Ji,nun
[XjJul
[X�Aug
[ Sep
Oct
Nov.
Dec
ThermostatSchedule: HERS 2006 Reference
Hours
ScheduleType
1
2
3
4
5
6
7
8
9 10
11
12
Cooling IWO) AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling(WEH) AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating(WD) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
Heating(WEH) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
FumitureFraction
Space
Default(8 lbslsq.ft.
0 ft2
0 ft
0.3
BEDROOM
Default(8lbslsq.ft.
ft2
ft
0.3
WIC
Default(8lbs/sq.ft.
ft2
ft
0.3
M. BATH
Defaull(8lbs/sq.ft.
ft'
ft
0.3
KITCHEN
Default(8 lbslsq.ft.
ft2
ft
0.3
BATH
Default(8 lbslsq.ft.
ft2
ft
0.3
BEDROOM
Default(8 lbslsq.ft.
ft2
ft
0.3
ENTRY
Default(8lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 lbs/s.ft.
ft2
ft
0.3
GREAT/DINING
1/8/20204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5of5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATIONINSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, Stale, Zip: FT. PIERCE, FL, Permit Number:
X
Owner. WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
=
Design Location: FL, Fort Pierce
c�
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be Installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
Insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the lop side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor Insulation, Insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts In narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures Installed In the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt Insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind ninino and Wrino.
Shower/tub
The air barrier installed at exterior walls adjacent toshowers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
hptween fire snrinkler cover Mates and walls or ceillnus I
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
1/8/2020 4:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b). Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5. Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1446
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor.(weighted average)
7a. 1.060
b) Solar Heat Gain Coefficient (SHGC)
71b. 0.284
14. Heating system: Capacity
34.8
c) Area
7c. 141.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior.
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
15. Water heating system
a) Electric resistance EF 0.97
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
f) Heat recovery unit HeatRec%
g) Other
10131.
11.0
1082.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a.
30.0
b) Cross ventilation No
11b.
c) Whole house fan No
11c.
19.0
d) Multizone cooling credit
11d.
No
e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: �� Date: ),\ -)_\go
Address of New Home: ✓� `\� � City/FL Zip: - FT. PIERCE. FIL
1/8/2020 4:19:34 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1