Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: WYNNE THE GRAN CARLTON IMPACT BuilderName: WYNNE BUILDING COPR. Street: wv\ksr\ Permit Office: ST.LUCIECOUNTY City, State, Zip: FT. PIERCE, FL, PernitNumber: Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Designt-ocation: FL, Fort Pierce County: St. Lucie (Florida Crimate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sgft.) Insulation Area 2. Single family ormultiple family Single-family a. Concrete Block- Int lnsul, Exterior R=4.1 1250.00 fi- b. Frame -Wood, Adjacent R=11.0 192.00ft- 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d.N/A R= ft- 10.Ceiling Types (1476.0 sqft.) Insulation Area 5. Is thisaworsl case? Yes a. UnderAttic(Vented) R=30.0 1446.00ft= 6. Conditioned floorarea above grade(ft� 1446 b. Knee Wall (Vented) -R=19.0 30.00 fN Conditioned Floorareabelowgrade(ft� 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(141.3 sgfL) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 175 a. U-Factor. Sgl, U=1.04 101.25 ft' SHGC: SHGC=029 b. U-Factor: Sgl, U=1.11 40.00 ft- 12• Cooling systems kBtulhr Efficiency SHGC: SHGC=027 a. Central Unit 34.8 SEER:15.00 c. U-Factor. N/A ft' SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor: WA ft' a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted AverageOverhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.284 14. Hot water systems a. Electric Cap:40 gallons _ 8. FloorTypes (1446.5 sgft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft' b. Conservation features b. WA R= ft' None c. NIA R= ft' 15. Credits Pstat Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.50 PASS Total Baseline Loads: 48.09 I hereby certify that the plans and specifications covered by Review of the plans and 'EMSTg7 this calculation are in compliance with the Florida Energy specifications covered by this Oki Code. calculation indicates compliance y ��0% M with the Florida Energy Code. PREPARED BY: _I ._II S!`!(P_�1_U'[a �9.1�K(rJ Before construction is completed DATE: 1-9-20 this building will be inspected for compliance with Section 553.908 , e I hereby certify that this building, as designed, is in compliance Florida Statutes. ,!1 with the Florida Energy Cod cOD.yy� C4 OWNER/A� T BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH150 (R402.4.1.2). REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY 118120204:18 PM EnergyGaugeO USA 6.0.02(Rev:1)- FlaRes2017 FBC 6th Edition (2017)ConBOn o re Paget of FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE GRAND CARLT Bedrooms: 2 Address Type: StreetAddress BulldingType: User ConditionedArea: 1446 Lot# OwherName: WYNNE BUILDING CROP TotalSlorles: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: BuilderName:. WYNNE BUILDING COPR. RotateAngle: 180 Street: Permit Office: ST. LUCIE COUNTY CrossVentilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY 'Whole House Fan: No City, State, Zip: FT. PIERCE, FamilyTyps: Single-family FL, NewIE)dsting: New (From Plans) Comment: CLIMATE . / - Design Temp Int Design Temp Heating Design DailyTemp V Designt-ocation TMYSite 97.5% 2.5% Winter Summer DegreeDays Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70- 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name .Area Volume Kitchen Occupants Bedrooms. Infli ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREATIDINING 488 3904 No 0 1 Yes Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 52 it 0 301 ft' 0 1 0 2 Slab -On -Grade Edge Insulation WIC 1ft 0 63 ft' ___ 0 1 0 3 Slab -On -Grade Edge Insulation M.BATH 8ft 0 56 ft' ____ 0 1 0 4 Slab -On -Grade Edge Insulation KITCHEN tft 0 192 ft' ____ 0 1 0 5 Slab-On-GradeEdgelnsulalion BATH 5 ft 0 45 ft' _—_ 0 1 0 6 Slab -On -Grade Edge Insulation BEDROOM 32.2ft 0 203.5ft ____ 0 1 0 7 Slab -On -Grade Edge Insulation ENTRY 7ft 0 55 It, ---- 0 1 0, 118120204:18 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition,(2017) Compliant Software Page 2of5 FORM R405-2017 INF'U 15UMMAKY GHtGKLI51 KCPUKI FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulation LAUNDRY Eft 0 42 ft2 ---- 0 1 0 9SIab-On-Grade Edgelnsulation GREAT/DINING 46ft 0 488 ft2 ---- 0 1 0 ROOF Roof Gable Roof Red Solar SA Emitt Emift Deck Pilch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 GableorShed Metal 1524111 240 ft' Light N 0.6 No 0.9 No ..0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 UnderAttic(Vented) BEDROOM 30 Blown 301 ft' 0.1 Wood _ 2 UnderAttic(Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 UnderAttic(Vented) M.BATH 30 Blown 56 ft2 0.1 Wood _ 4 UnderAttic(Vented) KITCHEN 30 Blown 192 ft' 0.1 Wood 5 UnderAttic(Vented) BATH 30 Blown 4511' 0.1 Wood 6 UnderAttic(Vented) BEDROOM 30 Blown 204W 0.1 Wood 7 UnderAttic(Vented) ENTRY 30 Blown 55 ft' 0.1 Wood 8 UnderAttic(Vented) LAUNDRY 30 Blown 42W 0.1 Wood 9 UnderAttic(Vented) GREAT/DINING 30 Blown 488 ft' 0.1 Wood 10 Knee Wall (Vented) GREAT/DINING 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 NE=>SW Exterior Concrete Block- IntlnsulBEDROOM 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 _ 2 SW=>NE Exterior Concrete Block- Int lnsul BEDROOM 4.1 28 0 8 0 224.0W 0 0 0.4 0 _ 3 NW=>SE Exterior Concrete Block- Int lnsul BEDROOM 4.1 14 0 8 0 112.Oft2 0 0 0.4 0 _ 4 SW=>NE Exterior Concrete Block - Intlnsul M.BATH 4.1 8 0 6 0 64.0 ft' 0 0 0.4 0 _ 5 NE=>SW Exterior Concrete Block - Intlnsul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 6 NE=>SW Exterior Concrete Block- Int lnsuBEDROOM 2 4.1 16 0 8 0 128.0 ft' 0 0 0.4 0 7 SE=>NW Exterior Concrete Block- InllnsuBEDROOM 2 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 8 S=>N Exterior Concrete Block- Int lnsuBEDROOM 2 4.1 4 3 8 0 34.0 ft' 0 0 0.4 0 _ 9 SW=>NE Exterior Concrete Block- Int lnsuBEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 10 SE=>NW Exterior Concrete Block-Intlnsul ENTRY 4.1 6 0 8 0 48.0 ft' 0 0 0.4 0 11 SW=>NE Exterior Concrete Block- Intlnsul ENTRY 4.1 1 0 8 0 8.0 ft' 0 0 0.4 0 12 SW=>NE Exterior Concrete Block-Intlnsul LAUNDRY 4.1 6 0 8 0 48.0 ft' 0 0 0.4 0 13 NE=>SW Exterior Concrete Block -Int lnsuGREAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.4 0 14 NW=>SE Exterior Concrete Block -Int lnsuGREAT/DINT 4.1 20 0 8 0 160.0 ft' 0 0 0.4 0 1/8120204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3of5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space .Cavity Width Height Sheathing Framing Solar Below 15 N=>S Garage Frame -Wood KITCHEN 11 24 8 192.0 ft' 0.23 0.4 0 DOORS # Ornt DoorType Space. Storms U-Value Width Height Ft In Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6It- WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall # Omt ID Frame Panes" NFRC U-Factor SHGC Imp Overhang Area Depth Separation IntShade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Low-ESingle Low-ESingle Low-ESingle Law-ESingle Low-ESingle Yes 1.04 0.29 Y Yes 1.04 0.29 Y Yes 1.04 0:29 Y Yes 1.04 0.29 Y Yes 1.11 0.27 Y 32.9 ft- 1 ft 0 in 1 ft 5 in Drapeslblinds 6.9 ft- 1 ft 0 in 1 ft 5 in None 24.0 ft- 6 ft 0 in 1 ft5 in None 37.5 ft2 1 ft 0 in 1 ft 5 in. None 40.0 ft2 8ft0in Ift5In Drapestblinds Exterior5 None None None Extedor5 GARAGE # FloorArea - CeilingArea Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft2 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 60' 1 Wholehouse ProposedACH(50) .000356 1349.6 74.09 139.34 .1233 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Single HSPF:8.5 34.8 kBtuihr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 CentralUnitf Split Single SEER: 15 34.8 kBtu/hr dm 018 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40gal 60.9gaj 120deg None 1/8120204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page of 5. FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # CompanyName System Model# CollectorModel# Area Volume FEF None None ft2 DUCTS / —Supply— —Return— Air :CFM25 CFM25 HVAC# V # Location R-Value Area Location Area LeakageType Handler TOT OUT ON RLF Heat Cool 1 Attic 6 175 ft2 Attic 65 ft2 DefaullLeakage Attic (Default) c(Default) c 1 1 TEMPERATURES ProgramablreOTC,Ihermostatr: Y Ceiling Fans: Venting rf�' Apr I IMay fr TI t` 4 trX r cc [ ]Jan [ ].Feb [X]Mar [x]Ji,nun [XjJul [X�Aug [ Sep Oct Nov. Dec ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling IWO) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness FumitureFraction Space Default(8 lbslsq.ft. 0 ft2 0 ft 0.3 BEDROOM Default(8lbslsq.ft. ft2 ft 0.3 WIC Default(8lbs/sq.ft. ft2 ft 0.3 M. BATH Defaull(8lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 lbslsq.ft. ft2 ft 0.3 BATH Default(8 lbslsq.ft. ft2 ft 0.3 BEDROOM Default(8 lbslsq.ft. ft2 ft 0.3 ENTRY Default(8lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 lbs/s.ft. ft2 ft 0.3 GREAT/DINING 1/8/20204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5of5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATIONINSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, Stale, Zip: FT. PIERCE, FL, Permit Number: X Owner. WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY = Design Location: FL, Fort Pierce c� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be Installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including Insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the lop side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor Insulation, Insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts In narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures Installed In the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt Insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind ninino and Wrino. Shower/tub The air barrier installed at exterior walls adjacent toshowers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids hptween fire snrinkler cover Mates and walls or ceillnus I a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 1/8/2020 4:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b). Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1446 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor.(weighted average) 7a. 1.060 b) Solar Heat Gain Coefficient (SHGC) 71b. 0.284 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior. 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 15. Water heating system a) Electric resistance EF 0.97 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 10131. 11.0 1082. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. 19.0 d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: �� Date: ),\ -)_\go Address of New Home: ✓� `\� � City/FL Zip: - FT. PIERCE. FIL 1/8/2020 4:19:34 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1