Loading...
HomeMy WebLinkAboutHealth Dept Final ApprovalSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: Ron Raymond Construction AGENT: Richard Laventure (Laventure & Associates Inc) PROPERTY ADDRESS: 1417 Lone Pine Dr Port Saint Lucie, FL 34983 APPLICATION #:AP1412902 PERMIT #:56 -SF -1947479 DOCUMENT #: F11425599 DATE PAID:05/08/2019 FEE PAID:515.00 RECEIPT #:56 -PID -3934475 LOT: BLOCK: SUBDIVISION: Lone Pine ID#: 3409-505-0004-000-2 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1090.00 [2] [ ] [27] SURFACE WATER FT [ ] [02] TANK MATERIAL Polypropylene [ ] [28] DITCHES FT [ ] [03] OUTLET DEVICE [ ] [29] PRIVATE WELLS FT [ ] [04] MULTI-CHAMBERED [ Y N ] [ ] [30] PUBLIC WELLS FT [ ] [05] OUTLET FILTER PolylokPL-68 [ ] [31] IRRIGATION WELLS 98 FT [ ] [06] LEGEND 1. 70-143-11DC4 2. [ ] [32] POTABLE WATER 36 FT [ ] [07] WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 9 FT [ ] [08] LEVEL [ ] [34] PROPERTY LINES 12 FT [ ] [09] DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 679.2 [2] SQFT [ ] [36] DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER X [ ] [37] SHOULDERS [ ] [12] NUMBER OF DRAINLINES 1. 7.00 2. [ ] [38] SLOPES [ ] [13] DRAINLINE SEPARATION [ ] [39] STABILIZATION 05/14/2020 [ ] [14] DRAINLINE SLOPE [ ] [15] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM 4.00 [ ] [40] UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF [ ] [18] DOSING PUMPS L ] [42] ALARMS [ ] [19] AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ ] [21] AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN L ] [46] FINAL SITE GRADING FILL / EXCAVATION MATERIAL [ ] [22] FILL AMOUNT [ ] [47] CONTRACTOR MICHAEL W STUHR (ASHTO [ ] [23] FILL TEXTURE [ ] [48] OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [49] TANK PUMPED [ ] [26] REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. / St. Lucie CHD DATE: 03/05/2020 CONSTRUCTIONL APPROVED ] DISAPPROVED ' Environmental SpecialistJ Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM L / St. Lucie CHD DATE: 05/14/2020 APPROVED DISAPPROVED ]: Environmental Specialist rian J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v1.0.1 AP1412902 EID1947479 APPLICATION # : AP 1412902 STATE OF FLORIDA PERMIT #:56 -SF -1947479 DEPARTMENT OF HEALTH DOCUMENT #: FI 1425599 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AFINAL APPROVAL DATE PAID:05/08/2019 ND FEE PAID :515.00 RECEIPT #:56 -PID -3934475 Violation Number Comment Comments The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 400 gpd. New ST, filter, and 4x9+3x8 long DF installed. No violations, system ok to cover. Contractor notified onsite. Needs final nspection for mound system and final site grading. Irrigation well inspected at construction inspection. :final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1412902 EID1947479