HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE GRAND CAARLTON
Builder Name: WYNNE BUILDING COPR.
• Street: -b s -,3 6.c--, e yC S
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner. WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or e)isttng New (From Plans)
9. Wall Types (1442.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, F)derior
R=4.1 1250.00 ft'
b. Frame- Wood, Adjacent
R=11.0 192.00 ft'
3. Number of units, if multiple family 1
c. N/A
R= ft'
4. Number of Bedrooms 2
d. N/A
R= ft'
5. Is this a worst case? Yes
10. Ceiling Types (1476.0 sqft.)
Insulation .Area
a. Under Attic (Vented)
R=30.0 1446.00 ft'
6. Conditioned floor area above grade (ftl 1446
b. Knee Wall (Vented)
R=19.0 30.00 ft'
Conditioned floor area below grade (ftl 0
c. N/A
R= ft'
11. Ducts
R ft'
7. Windows(141.3 sgft) Description Area
a. Sup: Attic, Rat: Attic, AH: Attic
6 250
a. U-Factor. Sgl, U=0.54 101.25 ft'
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55 40.00 ft'
12. Cooling systems
kBtulhr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor: WA ft'
SHGC:
13. Healing systems
kBlu/hr Efficiency
d. U-Factor: N/A ft'
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1445.6 sgft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft'
b. Conservation features
b. N/A R= ft'
None
c. NIA R= ft'
15. Credits
Pstat
Glass/Floor Area: 0.098 Total Proposed Modred Loads: 46.72
PASS
Total Baseline Loads: 48.09
1 hereby certify that the plans and specifications covered by
Review of the plans, and
04 TkiE5z
this calculation are in compliance with the Florida Energy
specifications covered by this
= O
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: lbsz
Before construction is completed
o
DATE: 1-8-20
this building will be inspected for
compliance with Section 553.908
a q
O
hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
'yylc'11t
OWNER/A��
BUILDING OFFICIAL:
DATE: `
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factorysealed in accordance with R403.3.2.1.
- Compliance requires an Alt Baffler and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (11402.4.1.2).
REVIEWED FOR
CODE COMPLIANCE
ST= LUCIE COUNTY
1/8/2020 2:47 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant SoftwarEBOCCy Page 1 of 5
FORM R405-2017 INPUT SUMMARYCHECKLIST REPORT
PROJECT
Title: WYNNE THE GRAND CARL Bedrooms: 2
Address Type:
Street Address
Building Type: User Conditioned Area: 1446
Lot #
Owner Name: WYNNE BUILDING CROP Total Stories: 1
Block/SubdiNsion:
#of Units: 1 Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180
Street:
Permit Office: ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No
City, State; Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/ExistIng: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Healing
Design Daily Temp
Design Location TMY Site 97.5 °h 2.5 %
Winter
Summer Degree Days Moisture
Range"
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name ,Area Volume
1 Entire House 1446 11568
SPACES
Number Name Area Volume Kitchen Occupants
'Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM 301 2408 No 0
1
1 Yes
Yes
Yes
2 WIC 63 .504 No 0
1 No
Yes
Yes
3 M. BATH 56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN 192 1536 Yes 0
1 No
Yes
Yes
5 BATH 45 360 No 0
1 Yes
Yes
Yes
6 BEDROOM 2 204 1632 No 0
1
1 Yes
Yes
Yes
7 ENTRY 55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY 42 336 No 0
1 Yes
Yes
Yes
.9 GREAT/DINING 488 3904 No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge lnsulatio BEDROOM 52 ft 0
301 ft'
0 1
0
2 Slab -On -Grade Edge lnsulatio WIC 1 ft - 0
63 ft-
'-___
o 1
0
3 Slab -Oh -Grade Edge lnsulatio M. BATH' 8 ft 0
56 ft'
—
0 1.
0
4 Stab -On -Grade Edge lnsulatio KITCHEN 1 ft 0
192 ft'
_
0 1
0
5 Slab -On -Grade Edge Insulato BATH 58 0
45 ft'
0 1
0
6 Slab -On -Grade Edge lnsulatio BEDROOM 2 32.2 ft 0
203.5 ft'
_
0 1
0
7SIab-On-Grade Edge lnsulatio ENTRY 7 ft 0
55 ft'
_
0 1
0
1/8/2020 2:47 PM EnergyGaugeO USA 6.0.02.(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORMR405-2017 INPUT bU1MnnAKY:GFIEGKLIb'1 KCPUKI
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY Eft
0
42 ft2
_
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 It 0
488 ft2
0
1
0
ROOF
/ Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor:
Tested
Tested Insul.
(deg)
1 Gable or Shed Metal 1524 ft2
240 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V
# Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1446 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
_ 1 Under Attic (Vented) BEDROOM
30
Blown
30111'
0.1
Wood
_ 2 Under Attic (Vented) WIC
30
Blown
63ft"
0.1
Wood
_ 3 Under Attic (Vented) M. BATH
30.
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft'
0.1
Wood
_ 5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 Under Attic,(Vented) BEDROOM
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ;ENTRY
30
Blown
55 ft'
0.1
Wood
_ 8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
_ 9 Under Attic (Vented) GREAT/DINING
30
Blown
4881?
0.1
Wood
10 Knee Wall (Vented) GREATIDINING
19
Blown
30 ft2
0.11 -
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing . Solar
Below
rraffaqL-
_ 1 NE=>SW Exterior Concrete Block - Int Insi1BEDR00M
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
_ 2 SW=>NE Exterior Concrete Block - Int InsLIBEDROOM
4.1 28
0 8
0
224.0 ft2
0
0,
0.4
0
_ 3 NW=>SE Exterior Concrete Block - Int InsLSEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
_ 4 SW=>NE Exterior Concrete Block - Int Insul M. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.4.
0
_ 5 NE=>SW Exterior Concrete Block - Int Insul BATH
4.1 5
0 8
0
40.0 ft'
0
0
0.4
0
_ 6 NE=>SW Exterior Concrete Block - Int InsBEDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.4
0
_ 7 SE=>NW Exterior Concrete Block- Int InsEKEDROOM 2
4.1. 10
0 8
0
80.0 ft2
0
0
0.4
0
_ 8 S=>N Exterior Concrete Block - Int IhsBEDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.4
0
_ 9 SW=>NE Exterior Concrete Block- Int InsEIEDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.4
0
10 SE=>NW Exterior Concrete Block- Int Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
11 SW=>NE Exterior Concrete Block -Int Insul ENTRY
4.1 1
0 8
0
8.0 fN
0
0
0.4
0
12 SW=>NE Exterior Concrete Block- Int InsULAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
13 NE=>SW Exterior Concrete Block- Int lnse8REAT/DINT
4.1 26
0 8
0
208.01N
0.
0
0.4
0
14 NW=>SE Exterior Concrete Block- Int Ins gREAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.4
0
1/8/2020 2'.47 PM EnergyGauge® USA 6.0.02(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space Cavity Width Height Sheathing Framing Solar Below
0
15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 f12 0.23 0.4
0
DOORS
# Omt
Door Type Space
Storms U-Value Width Height
Ft In Ft In
Area
1 SE=>NW
Insulated ENTRY
None .39 3 1 6 8
20.6 ft'
WINDOWS'
Orientation shown is the entered. orientation => changed to Worst Case.
_ / Wall
V # Ornt ID Frame
Panes NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1 NW=>SE 3 Metal
_ 2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
_ 4 NE=>SW 13 Metal
5 NW=>SE14 Metal
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
0.54 '0.25 N 32.9 fV 1 ft 0 in 1 ft 51n Drapesiblinds
0.54 0.25 N 6.9 ft' 1 ft 0 in 1 ft 5 in None
0.54 0.25 N 24.0 fl' 6 It 0 in 1 ft 51n None
0.54 0.25 N 37.5 ft- 1 ft'0 in 1 ft 5 in None
0.55 0.25 N 40.0 ft' 8 ft 0 in 1 It 5 in Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall insulation
1 315 ft2
315 ft2
24ft 8ft 11
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1349.6 74.09 139.34 .1233 7
HEATING SYSTEM
# System. Type
Subtype
Speed Efficiency Capacity Block_
Ducts
1 Electric Heat Pump/ Split
Singl HSPF:8.5 34.8 kBtulhr 1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split
Singi SEER: 15 34.8 kBtumr cm 0.8 1
sys#1
HOT WATER SYSTEM
# System Type
SubType Location
EF Cap Use 'SetPnt. Conservation
1 Electric
None Garage
0.97 40 gat 60.9 gal ,120 degNone
1/8/2020 2:47 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software - Page 4 of 5
FORM R405-2017 INPUT SUMMARY` CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # Company Name
System
Model #
Collector Model
# Area Volume
FEF
None None
ft2
DUCTS
— Supply —
— Return —
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT ON RLF
Heal Cool
.1 Attic 6 260 11:2
Attic
65 ft2
Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Progremablfe
CfIeilling Faris:
,
lThermosta[Lt:]]Y ff ]1
HeatinDoc
g - [XI IN Feb IX1 Mar
E[ jji
W
May
JMe un
rl
[X�
) Jul
[X
[ Aug
�X
[� � Sep
[ ] I(X�I
l J Ocl m
Nov
1NovrX�i
Dec
Venting [(( 111 Jan [) Feb lki Mar
l l
lxl Aprr
[,
]
Jun
E ) Jul
l III Aug
[ Sep
lxl
[ ]
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2
3
4-
5
6
7
8
9 10
11
12
Cooling (WD) AM 78
78
78
78
78
78
78
78
80 80
80
.SO
PM 80
80
78
78
78
78
78
78
78 78
78
78
Cooling (WEH) AM 78
78
78
78
78
78
78
78
78 78
78
78
PM 78
78
78
78
78
78
78
78
78 78
78
78
Heating (WD) AM 66 .
66
66
66
66
68
68
68
68 68
68,
68
PM 68
68
68
68
68
68
68
68
68 68
66
66
Heating (WEH) AM 66
66
66
66
66
68
68
68
68 68
68
-68
PM 68
68
68
. 68
68
68
68`
68••
68 . 68
66
66
MASS
Mass Type
Area
Thickness
Furniture fraction
Space.
Default(8 lbs/sq.ft.
0 ft2
0 ft
0.3
GREAT ROOM
Default(8lbs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8 lbs/sqft
ft2
It
0.3
WIC
Default(8 lbs/sq.ft.
ft2
- ft
0.3
CLST.
Default(8 lbs/sq.ft
ft2
ft
0.3
M BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
ft
0.3
JUNIOR M.-BED
Default(8 Ibs/sq.ft
ft2
ft
0.3
'BATH
Default(8 lbs/sq.fL
ft2
ft
0.3.
POWDER
Default(B lbs/sq.ft.
ft2
ft
0.3
NOOK
"•
Default(8 lbs/sq.fL
ft2
ft
0.3
LAUNDRY
Default(8 lbs/s0.
ft2
ft °
0:3
'ENTRY
1/8/2020 2:47 PM EnergyGauge®.USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip:. FT. PIERCE, FL, Permit Number:
U
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY.
w
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
Acontinuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation In any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be Insulated by completely filling the cavity
sealed.
vWtha material having a.thernal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope: insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door lambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity Insulation shallbe installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking,.or floor framing cavity insulation
and cantilevered
shall be permitted to be In contact with the top side
floors)
of sheathing, or continuous insulation installed on '
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where. provided Instead of.floor insulation, Insulation
a Class I vapor retarder with overlapping joints taped.
'shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and Rue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
Installation readily conforms to the available cavity,
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures Installed In the building thermal envelope
Recessed light &cures Installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and Wing
Batt insulation shall be cut neatly to fit around wiring
and plumbing In exterior walls, or Insulation that on
Installation readily conforms to available space shall
extend behind pining an Wring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Elechical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be Installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that Is recommended by the manufacturer.
I
Caulking or other adhesive sealants shall not be used to fill voids
fire rink! cover Mates and wall or ceillno I
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
118/2020 2:47 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL{EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system , SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1446
d) Room unitIPTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.543
b) Solar Heat Gain Coefricient'(SHGC)
7b.
0.250
14. Heating system: Capacity
34.8
c) Area
7c.
141.3
a) Split system heat,pump HSPF .
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance" COP
a) U-factor.(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
0 Heat recovery unit HeatRec%o
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level a) Ceiling fans
a) Under attic 11a. 30.0 b) Cross ventilation No
b) Single assembly 11b. c) Whole house fan No
c) Knee walls/skylight walls 11c. 19.0 d) Multizone cooling credit
d) Radiant barrier installed 11d. No e) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final Inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Homer City/FL Zip: FT. PIERCE, FL�"L`
1/8/2020 2:47:26 PM EnergyGauge®. USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1