Loading...
HomeMy WebLinkAboutProduct approvals, doors Florida Building Code Online Page 1 of 4 0 BCIS Home ? Log In user Registration Hot Topics Submit Surcharge j Stats&Facts Publications Contact Us BCIS Site Map Links ( Search Florida Product Approval USER:Public User Lt ".sF„�iem Product Approval Menu>Product or Aooiication Search>Application List>Application Detail •a FL# FL22633-R4 Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived ❑ Product Manufacturer Masonite International Address/Phone/Email 1955 Powis Road West Chicago,IL 60185 (800)663-3667 sschreiber@masonite.com Authorized Signature Steve Schreiber sschreiber@masonite.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 01/25/2019 Date Validated 02/25/2019 Date Pending FBC Approval Date Approved 03/05/2019 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGE.VXQwtDgv3cRDYzFYh... 5/21/2020 Florida Building Code Online Page 2 of 4 Summary of Products FL# Model,Number or Name Description 22633.1 HPC Steel-edge Steel Side-Hinged 6'-8"Glazed I/S or O/S Single or Double Door w/or w/o Door Unit Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22633 R4 C CAC NI013762.01-111.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 06/30/2021 Design Pressure:+50/-50 Installation Instructions Other:Evaluated for use in locations adhering to the Florida FL22633 R4 II FL0221.odf Building Code,including the High Velocity Hurricane Zone, Verified By: National Accreditation&Management Institute and where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 6'-8"max nominal size.When Evaluation Reports impact resistance is required,hurricane protective system is FL22633 R4 AE 514008.odf required.Door top rails stamped"HPC".See DWG-MA-FLO221 Created by Independent Third Party:Yes for details. 22633_:2_-- HPC Steel-edge Steel Side-Hinged 6'-8"Impact Glazed I/S or O/S Single or Double Door w/or r� Door Unit w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22633 R4 C CAC NI013762.04-R2.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure: +50/-50 Installation Instructions Other:Evaluated for use in locations adhering to the Florida FL22633 R4 II FL0223.odf Building Code,including the High Velocity Hurricane Zone, Verified By: National Accreditation&Management Institute and where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 6'-8"max nominal size.When Evaluation Reports impact resistance is required,hurricane protective system is FL22633 R4 AE 514008.odf not required. Door top rails stamped"HPC".See DWG-MA- Created by Independent Third Party:Yes FL0223 for details. 22633.3 Steel-edge Steel Side-Hinged Door 8'-0"Opaque I/S or O/S Single or Double Door w/or w/o Unit Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22633 R4 C CAC NI013762.06.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2021 Design Pressure:+48/-48 Installation Instructions Other:Evaluated for use in locations adhering to the Florida FL22633 R4 II FL0224.odf Building Code,including the High Velocity Hurricane Zone, Verified By: National Accreditation&Management Institute. and where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 8'-0"max nominal size.When Evaluation Reports impact resistance is required,hurricane protective system is FL22633 R4 AE 514007.odf not required on doors,but is required on sidelites.See DWG- Created by Independent Third Party:Yes MA-FL0224 for details. 22633.4 Steel-edge Steel Side-Hinged Door 8'-0"Glazed I/S Single or Double Door w/or w/o Sidelites Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22633 R4 C CAC NI013762.07.odF Approved for use outside HVHZ:Yes - Quality Assurance Contract Expiration Date Impact Resistant:No 06/30/2021 Design Pressure: +40/-45 Installation Instructions Other:Evaluated for use in locations adhering to the Florida FL22633 R4 II FL0225.1)df Building Code,including the High Velocity Hurricane Zone, Verified By: National Accreditation&Management Institute and where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 8'-0"max nominal size.When Evaluation Reports impact resistance is required,hurricane protective system is FL22633 R4 AE 514007.1)df required.See DWG-MA-FL0225 for details. Created by Independent Third Party:Yes 22633.5 Steel-edge Steel Side-Hinged Door 8'-0"Glazed O/S Single or Double Door w/or w/o Sidelites Unit Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22633 R4 C CAC NI013762.07.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 06/30/2021 Design Pressure: +45/-40 Installation Instructions Other:Evaluated for use in locations adhering to the Florida FL22633 R4 II FL0225.1)df Building Code,including the High Velocity Hurricane Zone, Verified By: National Accreditation&Management Institute and where pressure requirements do not exceed the design Created by Independent Third Party: pressures listed. 12'-0"x 8'-0"max nominal size.When Evaluation Reports impact resistance is required,hurricane protective system is FL22633 R4 AE 514007.odf required.See DWG-MA-FL0225 for details. Created by Independent Third Party:Yes 22633.6 Steel-edge Steel Side-Hinged Door 8'-0"Impact Glazed I/S or O/S Single or Double Door w/or Unit w/o Sidelites I i https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEV XQwtDgv3 cRDYzFYh... 5/21/2020 1 1 �. ' �4nopAg•-- - - Nei Av,r►�-- 1 a y t i w � r 1 a i NOTICE OF PRODUCT CERTIFICATION Company: Masonite International COrpnrallon Ccrt(Rcatlon No.: NI0I3762.04-It2 � �T 1955 Poen Road Certification Date: 06/26/2017 v • West Chicago,It.60185 Expiration])me: 06/30/2021 i Revision Date: 01/03/1019 Product: xletal-Edge Steel Opaque Inswing or Outswing Dnor ss/&Wo Impact Rated Sidelites asenPp (%vAVood Frame unless noted)(Doors Require"IIPC"Construction Slabs) i Specification: TAS 201/20M03-94 Glazing: Insulating Class:1/8"Tempered Glass/IB"Heal Strengthened Glass/0.090"Saflex PVH Interlayer/I/8"Ilcal Strengthened Glass 11. %atireotPrada,tC'eriirrcation"is only valid irrhe NANII Cerlificadon Label hn been applied to the product as described within this document.The certification label represents •:� product eontio—hy to the appticallk specification and that all cerliftea6on criteria has i satisfied.This product has been appro5ed for listing within NAMi's Certified Product Listing at— \ani ifrtro i­rnm NAMI's Certification Pro cam is accredited be The Atrledun National Standards In titute ANSI. j tmjng Glared Structural Water Missile Test Report Number C.onfgta trios or or Maatmum Design Test Impact DrawinENumber& 'f Outs"int Opaque SLx Pressure Pressure Rated Comments LS Glmd 3'0"s 6'8' -507-5D O.o psf Ycl ATL:C URS oI-iMV-19a3 1 'I Sinpk Alummm Pmd Sia:?'1'a 6'a- Alit-M-MIS-DIMG-MA-FLOM-17 'a- Anit-0.e,n-DWG-MA-FLOM-17 US Gland 3'0"\6'9' •50'•511 •1.75 p$1' Yes ATI.NC1111.111.11!W-Ia57AV-IA11 Siang 60 psi' Meamam Pmd sir•:7'a-s 6'r l I 7.50 sf"• Amhor Deeds-DW'G•MA-FLD27:-17 Sx IS Glared fi 0'6 6.9- -SO-50 0psl' Yes A11.N(7012511.17AV-Ito! ' Ugdde Mavmum raj Sim, Anchor Dcerls-DW 0.MA-s1M.l1-11 XN U•S Glued 6'0'A 6'8' -50•'-5D 3.75 psP Yes A'MC u12-eol-ItM'•In5 Double 6.0 ry CMasimum F-1 Sic:IT.,6'a' ~ 1.50 'f' A.,areilh-DWGUA•FL0223.17 I XO OS I.5 Glared Door 6'0-s 6.8" +50!•50 Opsf Dnm-Ys A17.NC012311-17Av-1115 Si*i,wSidelhe Gland Sidclila Sidelite-Yes VU—P^I Sin-?'D-.61:Mddm•:F4-s 61" Antler Detsile-DWG-AIA.FLAn3.I7 l I + XO GxOS 61—dGId Door 6.0-•.6.9• 50' - -30 3.75 psf' Door-Yat An.Nr o155 01.17.W.let. � Single w•:Stdda, Glaud Sidehto 6.0 inP Sidelim-1'es MAvmvm Prd Six Yu I",Iseldu,•?b'a6'x- 7.30 sf• Archon Deftih-MG•MA•FLan 1-11 , 030 I'S Gl=d Door 9'0"c 6'a" .50:40 01.1, Door,%'ec ATLNC412.n1.17M-IsAt 7 Singleri6iddilcs Mayed Sidelilc Sidelit,Yas Mm 1-1 Sia?'O'.ex5*44 'b•a nX' Andmr Details-ntVGA1A-FlIR!?•1/ ' ' USU O:S Glared Door 9'0•'x 6'8•' 150.50 3.75 psi' Door-Yea ATLNC n12511-IIAV•IJa4 ' e.oh, Sidelims Gh—d Sidelite 6.0 psf' Sidelac-Yes 5ti<cnml Prat S,m.?'o'a e'A-Slddiu T1's e'r' ; 1.50 sf' Archer DceOe•Ow4MA•FW225.17 I DXXG 15 Glazed Dior 12'4'x 6'e" 15(1+40 Opti Door-Yes An.COW.u1.17M.1)a5 l Doubli,.S,delites Gland Sidelite Sidelilt-yes slmim�.P-1Si.,Y0'e6-a tSidebte)V,Wit' Malar D mAc-DWG•MA•Fl.o?2t17 i oCxo U Glaxed Door1_7i7a'B" :50!•50 3,73 PSP Door-yes AILNCU12501-17AV•110 } I \Iaannm P.._,aim.3'1'46't'15ddaa.3'1'xe'X' �i •{ 'i I)ouhk x•Sidrlita Glucal Sidelite 6.0 psi' idelite-Ya 730 Anchor fAaids•DWG•M.x•FUR21•U r1-Um.res 6aarprr Onmin[Ternama t-Oramc.L:krla Oasu Me 7Lrtshold}N4DAm 0ulmiay l3mh'+W 4Pm TST6raasW hNPDun•1ae76rt�0ald 1 -National Accreditation.@ Management Institute,IneJ4794 George Washington:Memntial Highway/flayes,VA 23072 Tel:(804)684-5I24/Fax:(804)684-S 122 NAMI AUTHORIZED SIGNATURE: • I )12 W f 11087_11710_1.jpg 800x800 pixels 5/18/20.9:20 AM i 1 I ; SAS c (312) SHS j105�} 12 23 ca �Cra I https://www.paslc.orgtimageSketches/skelch/11/11087_11/10_1,lpg Page 1 of 1 — | � ' . ` | � | � \ —J 3Iva- DIRITES � / . — ' — 75 771 7- I INN r�a�' /