HomeMy WebLinkAboutEnergy CodeBBraden & Braden, AIA, PA
ALF Y" uaac0000sz
417 Coconut Ave. Stuart, FL 34996 • (772) 287-8258
St. Lucre County Building Dept.
Wynne Development
Date:
Address: i•25�" ��
Permit U: C�fk-
To whom it may concern,
This detail applies to the insulation in
the ends of the vaulted ceilings.
If you have any questions please feel
free to call me at 772-287-8258
R-19
WneIR.
Dden AIA
Braden t Braden AIA PA
Trusses at 24" o.c.
re shop drawings bg others
ceding transition ' =�
ded using metal studs
ernfy exact configuration
:es
transftlon Insul
w>-
Or
®'�
WM
UCO
R-30 Batts
batts
Drywall ceding
see typical section
: t a
nts
.FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR. BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE MANOR IMPACT
Builder Name: WYNNE BUILDING CORP.
Street: THE MANOR 71
�� kDOL , CS Permit Office: ST. LUCIE COUNTY
City, Slate, Zip: FT. PIERCE, FL, f� �, Permit Number:
Owner. WYNNE BUILDING CORP. -�,� ` r� 4,4 " Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
9. Wall Types(1654.2 'sgft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1374.20 ft2
b. Frame - Wood, Adjacent
R=11.0 280.00 112
3. Number of units, If multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
2
d. WA
R= ft2
5. Is this a worst case?
Yes
10. Ceiling Types (1754,0 sgft.)
Insulation Area
a. Under Attie (Vented)
R=30.0 1724.00 ft2
6. Conditioned floor area above grade (ft=J
1724
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (ft�
0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(153.4 sgft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 150
a. U-Factor: Sgl, U=1.04
113.35 ft2
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11
40.00 ft2
12.. Cooling systems
kBtuBv Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEEI2:15.00
c. U-Factor: WA
ft2
SHGC:
13. Healing systems
kBtulhr Efficiency
d. U-Factor. N/A
ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth:
3.010 ft.
Area Weighted Average SHGC:
0.285
14. Hot water systems
8. Floor Types (1723.5 sgft.)
Insulation Area
a. Electric
Cap: 50.gallons
a. Slab -On -Grade Edge Insulation
R=0.0 1723.50 ft2
b. Conservation features
EF: 0.950
b. N/A
R= ft2
None
c. N/A
R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.089
Total Proposed Modified Loads: 53.45
PASS
Total Baseline Loads: 54.12
I hereby certify that the plans and specifications covered by
Review of the plans and
TS> STq?A
this calculation are in compliance with the Florida Energy
specifications covered by this
04
b _ � p�
Code.
calculation indicates compliance
yam;m�
with the Florida Energy Code.
e o
PREPARED BY:
Before construction is completed
w�
DATE: 1-9-20 r
this building will be inspected for
compliance with Section 553,908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
WE{4�
OWNER/A E
BUILDING OFFICIAL:
DATE: \�`
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
REVIEWED FOR
CODE COMPLIANCE
1/8/2020 4:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2&TCo4liahA4ditwarP0 U N tl Nage l-of 6
BOCC
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNETHEMANOR IMPA
Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1724
Lot#
Owner Name: WYNNE BUILDING CORP.
Total Stories: 1
Block(Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING CORP.
Rotate Angle: 270
Street:
THE MANOR 71
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/E dsting: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
LOW
BLOCKS
Number Name Area
Volume
1 Entire House 1724
14774.8
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
infil ID
Finished Cooled
Heated
1 GREAT ROOM 546
5350.8 No
0
1
Yes
Yes
Yes
2 MASTER BEDROO 354
2832 No
2
1
1
Yes
Yes
Yes
3 WIC 77
616 No
0
1
No
Yes
Yes
4 CLST. 35
280 No
0
1
No
Yes
Yes
5 M BATH 54
432 No
0
1
Yes
Yes
Yes
6 KITCHEN 180
1440 Yes
0
1
Yes
Yes
Yes
7 JUNIOR M. BED 198
1584 No
0
1
1
Yes
Yes
Yes
8 BATH 50
400 No
0
1
No
Yes
Yes
9 POWDER 35
280 No
0
1
Yes
Yes
Yes
10 NOOK 42
336 No
0
1
Yes
Yes
Yes
11 LAUNDRY 49
392 No
0
1
Yes
Yes
Yes
12 ENTRY 104
832 No
0
1
Yes
Yes
Yes
FLOORS
# Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio GREAT
ROOM 47 ft 0
546-ft2
0 1
0
2 Slab -On -Grade Edge lnsulatio MASTER'BEDRO 46ft 0
354. ft'
—
0 1
0
3 Slab -On -Grade Edge lnsulatio WIC 1 ft 0
77 W
_---
0 1
0
4 Slab -On -Grade Edge lnsulatio CLST. 1 ft 0
35 ftz
____
0 1
0
5SIab-On-Grade Edge lnsulatio M BATH 9 ft 0
54 ft'
_
0 1
0
1/8/2020 4:31 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
6 Slab -On -Grade Edge Insulatio
KITCHEN 11 It
0
180 ft2
0 1
0
7SIab-On-Grade Edge Insulatio
JUNIOR M. BED 14 ft
0
198 ft2
____
0 1
0
8 Slab -On -Grade Edge Insulatio
BATH 1 ft
0
50 ft2
___
0 1
0
9 Slab -On -Grade Edge Insulatio
POWDER 5 It
0
35 ft2
____
0 1
0
10SIab-On-Grade Edge Insulatio
NOOK E ft
0
42 ft2
____
0 1
0
11SIab-On-Grade Edge Insulatio
LAUNDRY 17ft
0
49 ft2
____
0 1
0
12SIab-On-Grade Edge Insulatio
ENTRY 5.9 ft
0
103.5 ft2
0 1
0
ROOF
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V
# Type Materials
Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip
Metal 1817 ft2
0 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
# Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
300
1724112
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
_
1 Under Attic (Vented)
GREAT ROOM
30
Blown
546 ft2
0.1
Wood
2 Under Attic (Vented)
MASTER BEDRO
30
Blown
354 ft2
0.1
Wood
3 Under Attic (Vented)
WIC
30
Blown
77 ft2
0.1
Wood
_
4 Under Attic (Vented)
CLST.
30
Blown
35 ft2
0.1
Wood
5 Under Attic (Vented)
M BATH
30
Blown
54 ft2
0.1
Wood
_
6 Under Attic (Vented)
KITCHEN
30
Blown
180 ft2
0.1
Wood
7 Under Attic (Vented)
JUNIOR M. BED
30
Blown
198 ft2
0.1
Wood
8 Under Attic (Vented)
BATH
30
Blown
50 ft2
0.1
Wood
9 Under Attic (Vented)
POWDER
30
Blown
35 ft2
0.1
Wood
10 Under Attic (Vented)
NOOK
30
Blown
42 ft2
0.1
Wood
11 Under Attic (Vented)
LAUNDRY
30
Blown
49 ft2
0.1
Wood
12 Under Attic (Venter)
ENTRY
30
Blown
104 1112
0.1
Wood
13 Knee.Wall (Vented)
GREAT ROOM
19
Blown
30 ft2
0.11
Wood
WALLS
v it
n�t T. Wall Type Adjacent
Space Cavity Width
Height
Sheathing Framing Solar
Below
0
_ 1
SW=>SE Exterior Concrete Block - Int InsGREAT ROO
4.1 26
0 9
10
255.7 1112
0
0 0.3
0
_ 2
NW=>S Exterior Concrete Block - Int InsGREAT ROO
4.1 21
0 9
10
' 206.5 112
0
0 0.3
0
3
NE=>NW Exterior Concrete Block- Int InsWASTER BE
4.1 25
0 8
0
200.0 ft2
0
0 0.3
0
1/8/2020 4:31 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R406-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space
Cavity Width
Height
Sheathing Framing
Solar
Below
-4 SW=>SE Exterior
Concrete Block- Int Ins90ASTER BE
4.1 8
0
8 0
64.0 ft'
0
0
0.3
0
_ 5 NW=>S Exterior
Concrete Block- Int InsOnASTER BE
4.1 13
0
8 0
104.0 k'
0
0
0.3
0
_ 6 NE=>NW Exterior
Concrete Block- Int Insul M BATH
4.1 9
0
8 0
72.0 ft'
0
0
0.3
0
_7 SW=>SE Exterior
Concrete Block- Int lnsulKITCHEN
4.1 11
0
8 0
88.0 ft2
0
0
0.3
0
-8 NE=>NW Exterior
Concrete Block- Int InsdUNIOR M. B
4.1 14
0
8 0
112.0 ft'
0
0
0.3
0
-9 SW=>SE Exterior
Concrete Block - Int InsuIPOWDER
4.1 5
0
8 0
40.0 ft'
0
0
0.3
0
_ 10 SW=>SE Exterior
Concrete Block - Int Insul NOOK
4.1 6
0
8 0
48.0 ft2
0
0
0.3
0
11 NE=>NW Exterior
Concrete Block -Int lnsuLAUNDRY
4.1 3
0
8 0
24.0 112
0
0
0.3
0
12 SE=>NE Exterior
Concrete Block- Int lnsULAUNDRY
4.1 7
0
8 0
56.0 ft2
0
0
0.3
0
13 SW=>SE Exterior
Concrete Block- Int InsULAUNDRY
4.1 7
0
8 0
56.0 ft2
0
0
0.3
0
_ 14 SE=>NE Exterior
Concrete Block - Int Insul ENTRY
4.1 6
0
8 0
48.0 112
0
0
0.3
0
15 N=>W Garage
Frame -Wood ENTRY
11 35
8
280.0 ft2
0.23
0.3
0
DOORS
# Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 SE=>NE Insulated ENTRY
None
.32
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
Overhang
V # Omt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 SW=>SE 1
Metal Low-E Single Yes
1.04 0.29
N
46.4 ft'
1 it 0In
1 ft 5In
None
None
2 NW=>SW 2
Metal Low-E Single Yes
1.11 0.27
N
40.0 ft'
8 It 0 in
1 It 5 in
None
None
_ 3 NW=>SW 5
Metal Low-E Single Yes
1.04 0.29
N
32.4 112
1 ft 0 in
1 ft 5 In
None
None
4 NE=>NW 6
Metal Low-E Single Yes
1.04 0.29
N
6.9 ft2
1 it 0 in
1 It 5In
None
None
_ 5 NE=>NW 8
Metal Low-E Single Yes
1.04 0.29
N
16.2 112
1 it 0 in
1 ft 5 in
None
None
6 SW=>SE 9
Metal Low-E Single Yes
1.04 0.29
N
6.9 ft2
1 8 0 in
1 ft 5In
None
None
7 SE=>NE 12
Metal Low-E Single Yes
1.04 0.29
N
4.7 112
7 ft 01n
1 ft 5 in
None
None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 440 ft2 440 ft2
35 it
8 ft
11
INFILTRATION
# Scope Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000272 1231.2 67.59
127.12
.097
5
1/812020 4:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT 5UIMIVIARY GHEGKLI5I RI:PUKI
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
None
Singl HSPF:8.5 34.8 kBtulhr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity
Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 34.8 kBtu/hr 1044 cfm
0.85 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric None
Garage
0.95 50 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Carl # Company Name
System Model # Collector Model # Area
Volume
FEF
None None
ft'
DUCTS
/ — Supply—
— Return— Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type Handler
TOT
OUT ON RLF
Heat Cool
1 Attic 6 150 ft'
Attic
45 ft' Default Leakage Attic
(Default) (Default)
1 1
TEMPERATURES
ProgramabllCoolingre ThermostatJan:
Crreiling Fans:
,IY Feb IrX1
Veating Feb Mar
r
Apr
lXI �X
May Jun [ ] Jul [ Aug
1
4X] Sep
[ ]
l
Dec
rIX,�
[ ]Jan [ ] [X]
[ Jun O Jul [ Aug
O Sep
.1Oct X Nov
lxl
[ ]Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6 7
8
9
10 11
12
Cooling (WD) AM 78
78 78
78 78 78 78
78
80
80 80
80
PM 80
80 78
78 78 78 78
78
78
78 78
78
Cooling (WEH) AM 78
78 78
78 78 78 78
78
78
78 78
78
PM 78
78 78
78 78 78 78
78
78
78 78
78
Heating (WD) AM 66
66 66
66 66 68 68
68
68
68 68
68
PM 68
68 68
68 68 68 68
68
68
68 66
66
Heating(WEH) AM 66
66 66
66 66 68 68
68
68
68 -68
68
PM 68
68 68
68 68 68, 68
68
68
68 .66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 lbslsq.ft.
0 ft'
_ 0 ft 0.3
BEDROOM
Default(8 lbs/sq.ft.
ft'
ft 0.3
WIC
Default(B lbslsq.fL
ft'
ft 0.3
M. BATH
Default(8 lbs/sq.ft.
ft'
ft 0.3
KITCHEN
Default(8 lbslsq.fL
ft'
ft 0.3
BATH
Defaull(B lbs/sciA
ft'
ft 0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft'
ft 0.3
ENTRY
Default(8 lbs/sq.ft.
ft'
ft 0.3
LAUNDRY
1/8/2020 4:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017 INPUT SUMMARY. CHECKLIST REPORT
MASS
Mass Type Area Thickness Furniture Fraction Space
Defaull8lbs/s .ft. ft' ft 0.3 GREAT/DINING
1/8/2020 4:31 PM EnergyGauge® USA 6.0.02.(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE MANOR IMPACT Builder Name: WYNNE BUILDING CORP.
Street: THE MANOR 71 Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number.
Owner: WYNNE BUILDING CORP. Jurisdiction:
w
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barter shall be Installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The Insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be Insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per Inch minimum.
Exterior thermal envelope insulation for framed
walls shall be Installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be Installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvenled crawl spaces shall be covered with
Where provided instead of floor Insulation, insulation
a Class 1 vapor retarder With overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be out to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
Installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall,
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or Insulation that on
Installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be Insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be Installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
I between fire sprinkler cover plates and walls or ceilings,
I
a. in addition, inspection or iog wars snag us in accordance wan me provisions or iu:-vuu.
1/8/2020 4:36 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 61h Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX" = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1724
d) Room uniUPTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.058
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.285
14. Heating system: Capacity
34.8
c) Area
7c.
153.4
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
8.50
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a.
30.0
b) Cross ventilation,
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
19.0
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on i I de compliant features. \
Builder Signature: Date:
Address of New Home: THE MANOR 71 3 V ���7-¢.,� City/FL Zip: FT. PIERCE, FL
1/8/2020 4:36:22 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1