HomeMy WebLinkAboutWATERSTONE-01 DUCT LAYOUT14 x14 10,10 14 x14
OWNER'S SUITE
o If 6x6x4
i x 6 x 4 45 CFM_=i BEDROOM 2
25 CFM 4"0 DRYER
EXHAUST
HOV 12x8
HALL X—FER
CU -2
AIR CONDITIONING
DATA
QTY.
UNIT NO.
MFG.
CONDENSING UNIT
AIR HANDLING UNIT
TOTAL
SENSIBLE
SEER
TOTAL
0/A
HEAT PUMP
HSPF
AHRI
MODEL NO.
MODEL NO.
6x6x4
20 CFM
00
1
AHU/CU-1
GOODMAN
GSZ140301Ax
ARxF193116Cx
28.8
20.1
14 SEER
947
60
28
8.6
4888616
1
AHU/CU-1
DAIKIN
RX15RNDJU
FDMG15RVJU
14.4
10.1
20.2 SEER
600
40
18
10.3
201851572
A/C EQUIPMENT NOTES:
1) VERIFY ALL A/C ELECTRICAL REQUIREMENTS WITH MANUFACTURERS SPEC.
PRIOR TO
INSTALLATION.
2) PROVIDE PULL DISCONNECTS.
3) DIGITAL PROGRAMMABLE THERMOSTAT
14 x14 10,10 14 x14
OWNER'S SUITE
o If 6x6x4
i x 6 x 4 45 CFM_=i BEDROOM 2
25 CFM 4"0 DRYER
EXHAUST
HOV 12x8
HALL X—FER
CU -2
2.5—TON
50 CFM
EXHAUST
CU -2
-�
1.3—TON
6x6x4
20 CFM
00
24x18
SIDEWALL
R.A.G.
I AHU-1
I 2.5 TON
12x8
X—FER
ENTRY
DO NOT SCALE PLANS
T—STAT SHALL BE WITHIN 3 FEET
HORIZONTALLY OF MAIN RETURN
K. HOVNANIAN HOME5
LOT -01
FORT FIERCE,, FL 54951
VENTILATION PER F.B.C. 403.3
VENTILATION PER F.B.C. TABLE 403.3
OCCUPANCY: OFFICE
(OFFICE) 0/A
# OF PEOPLE: 3
CFM/PERSON:S
SQ FT: 380
CFM/ SQ FT: 0.06
(3 x 5) - (380 x 0.06)= 38 CFM
VENTILATION PER F.B.C. TABLE 403.3
OCCUPANCY: PRIVATE LIVING SPACE
(LIVING SPACE) O/A
# OF PEOPLE: 4
CFM/PERSON: 15
(4 x 15)= 60 CFM
(RESTROOM)EXHAUST
EF -1 x2= —100 CFM