Loading...
HomeMy WebLinkAboutWATERSTONE-01 DUCT LAYOUT14 x14 10,10 14 x14 OWNER'S SUITE o If 6x6x4 i x 6 x 4 45 CFM_=i BEDROOM 2 25 CFM 4"0 DRYER EXHAUST HOV 12x8 HALL X—FER CU -2 AIR CONDITIONING DATA QTY. UNIT NO. MFG. CONDENSING UNIT AIR HANDLING UNIT TOTAL SENSIBLE SEER TOTAL 0/A HEAT PUMP HSPF AHRI MODEL NO. MODEL NO. 6x6x4 20 CFM 00 1 AHU/CU-1 GOODMAN GSZ140301Ax ARxF193116Cx 28.8 20.1 14 SEER 947 60 28 8.6 4888616 1 AHU/CU-1 DAIKIN RX15RNDJU FDMG15RVJU 14.4 10.1 20.2 SEER 600 40 18 10.3 201851572 A/C EQUIPMENT NOTES: 1) VERIFY ALL A/C ELECTRICAL REQUIREMENTS WITH MANUFACTURERS SPEC. PRIOR TO INSTALLATION. 2) PROVIDE PULL DISCONNECTS. 3) DIGITAL PROGRAMMABLE THERMOSTAT 14 x14 10,10 14 x14 OWNER'S SUITE o If 6x6x4 i x 6 x 4 45 CFM_=i BEDROOM 2 25 CFM 4"0 DRYER EXHAUST HOV 12x8 HALL X—FER CU -2 2.5—TON 50 CFM EXHAUST CU -2 -� 1.3—TON 6x6x4 20 CFM 00 24x18 SIDEWALL R.A.G. I AHU-1 I 2.5 TON 12x8 X—FER ENTRY DO NOT SCALE PLANS T—STAT SHALL BE WITHIN 3 FEET HORIZONTALLY OF MAIN RETURN K. HOVNANIAN HOME5 LOT -01 FORT FIERCE,, FL 54951 VENTILATION PER F.B.C. 403.3 VENTILATION PER F.B.C. TABLE 403.3 OCCUPANCY: OFFICE (OFFICE) 0/A # OF PEOPLE: 3 CFM/PERSON:S SQ FT: 380 CFM/ SQ FT: 0.06 (3 x 5) - (380 x 0.06)= 38 CFM VENTILATION PER F.B.C. TABLE 403.3 OCCUPANCY: PRIVATE LIVING SPACE (LIVING SPACE) O/A # OF PEOPLE: 4 CFM/PERSON: 15 (4 x 15)= 60 CFM (RESTROOM)EXHAUST EF -1 x2= —100 CFM