Loading...
HomeMy WebLinkAboutWATERSTONE LOT-1 ENERGY CALC-2-EnergyGauge Summit® v6.10 INPUT DATA REPORT WS-01Project Name: 5226 ARMINA PLACEAddress: Owner: FLState: Zip: OfficeBuilding Type: New Finished buildingBuilding Classification: 1No.of Stories: Orientation: 1996GrossArea: Project Information 34951 0 Deg Clockwise. Walls & Windows will be rotated accordinglyWATERSTONE LOT-1Project Title: SF Type DescriptionAcronym Zones Area [sf] Multiplier Total Area [sf] No Pr0Zo1 Zone 1 CONDITIONED 1616.0 1 1616.01 SALES OFFICE Zone 2 CONDITIONED 380.0 1 380.02 15/19/2020 EnergyGauge Summit® v6.10 Width [ft] Depth [ft] Description Spaces Acronym Height [ft] No Multi plier Total Area [sf] Total Volume [cf] Type Pr0Zo1In Zone: Zo0Sp1 10.00 161.60 8.70PRIVATE LIVING 1 1616.0 14059.2Private Living Space1 SALES OFFICEIn Zone: Zo0Sp1 10.00 38.00 8.70Pr0Zo2Sp1 1 380.0 3306.0Office - Enclosed1 Control TypePower [W] Type Lighting No.of Ctrl pts No Category No. of Luminaires Watts per Luminaire In Zone: Pr0Zo1 In Space: PRIVATE LIVING 1 LED 448 Manual On/Off 8General Lighting 16 28 2 Incandescent 450 Manual On/Off 2General Lighting 2 225 In Zone: SALES OFFICE In Space: Pr0Zo2Sp1 1 Compact Fluorescent 336 Manual On/Off 3General Lighting 12 28 OrientationNo Walls (Walls will be rotated clockwise by building rotation value) Description Width [ft] H (Effec) [ft] Multi plier Area [sf] Conductance [Btu/hr. sf. F] Dens. [lb/cf] Heat Capacity [Btu/sf.F] R-Value [h.sf.F/Btu] Type In Zone: Pr0Zo1 1 Pr0Zo1Wa1 51.3 8.7 1 446.3 0.1491 5.653 37.15 6.7stucco /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp South 25/19/2020 EnergyGauge Summit® v6.10 2 Pr0Zo1Wa1 64.0 8.7 1 556.8 0.1491 5.653 37.15 6.7stucco /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp North 3 Pr0Zo1Wa1 35.0 8.7 1 304.5 0.1491 5.653 37.15 6.7stucco /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp East 4 Pr0Zo1Wa1 16.3 8.7 1 141.8 0.1491 5.653 37.15 6.7stucco /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp West In Zone: SALES OFFICE 1 Pr0Zo2Wa1 20.7 8.7 1 180.1 0.1491 5.653 37.15 6.7stucco /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp South 2 Pr0Zo2Wa1 18.8 8.7 1 163.6 0.1491 5.653 37.15 6.7stucco /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp East 3 Pr0Zo2Wa1 20.7 8.7 1 180.1 0.1491 5.653 37.15 6.7stucco /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp South No UOrientation Windows (Windows will be rotated clockwise by building rotation value) Description [Btu/hr sf F] SHGCShaded Vis.Tra W [ft] H (Effec) [ft] Multi plier [sf] Total Area Pr0Zo1In Zone: EAST WALLIn Wall: 2 Pr0Zo1Wa1Wi2 East 0.3200 0.3 0.6 4.3 5.0 3 64.5No NORTH WALLIn Wall: 1 Pr0Zo1Wa1Wi1 North 0.5500 0.3 0.6 6.0 6.7 1 40.2No 2 Pr0Zo1Wa1Wi2 North 0.3200 0.3 0.6 3.0 5.0 1 15.0No SOUTH WALLIn Wall: 2 Pr0Zo1Wa1Wi2 South 0.3200 0.3 0.6 3.0 5.0 1 15.0No WEST WALLIn Wall: 35/19/2020 EnergyGauge Summit® v6.10 1 Pr0Zo1Wa1Wi2 West 0.3200 0.3 0.5 3.0 5.0 1 15.0No SALES OFFICEIn Zone: SALES EAST WALLIn Wall: 1 Pr0Zo2Wa2Wi1 East 1.2500 0.8 0.8 3.0 6.7 2 40.2No 2 Pr0Zo2Wa2Wi1 East 1.2500 0.8 0.8 3.0 6.7 2 40.2No Doors No Description Area [sf] Multi plier H (Effec) [ft] Width [ft] Shaded? Cond. [Btu/hr. sf. F] Dens. [lb/cf] Heat Cap. [Btu/sf. F] R-Value [h.sf.F/Btu] Type In Zone: Pr0Zo1 In Wall: WEST WALL 20.116.703.00Pr0Zo1Wa5Dr11 0.3504 0.000.00 2.85Solid core flush (2.25) No Roofs No Description Width [ft] Tilt [deg] Area [sf] Multi plier H (Effec) [ft] Type Cond. [Btu/hr. Sf. F] Dens. [lb/cf] Heat Cap [Btu/sf. F] R-Value [h.sf.F/Btu] In Zone: Pr0Zo1 1 Pr0Zo1Rf1 161.60 10.00 1 1616.0 0.00 0.0320 31.28.221.50Shngl/1/2"WD Deck/WD Truss/9" Batt/Gyp Brd In Zone: SALES OFFICE 1 Pr0Zo2Rf1 38.00 10.00 1 380.0 0.00 0.0320 31.28.221.50Shngl/1/2"WD Deck/WD Truss/9" Batt/Gyp Brd UType DescriptionNo Skylights SHGC [Btu/hr sf F] Vis.Trans W [ft] H (Effec) [ft] Area [Sf] Multiplier Total Area [Sf] In Zone: In Roof: 45/19/2020 EnergyGauge Summit® v6.10 Floors No Description Area [sf] Multi plier H (Effec) [ft] Width [ft] Type Cond. [Btu/hr. sf. F] Dens. [lb/cf] Heat Cap. [Btu/sf. F] R-Value [h.sf.F/Btu] In Zone: Pr0Zo1 1 Pr0Zo1Fl1 161.60 1616.0110.001 ft. soil, concrete floor 0.2681 34.00 113.33 3.73 In Zone: SALES OFFICE 1 Pr0Zo2Fl1 38.00 380.0110.001 ft. soil, concrete floor 0.2681 34.00 113.33 3.73 Systems SYSTEM-2 System 2 Constant Volume Air Cooled Split System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1No. Of Units 1 Cooling System 14400.00 20.20 8.00 2 Heating System 18000.00 1.00 3 Air Handling System -Supply 600.00 0.80 4 Air Distribution System (Sup) 6.00 SYSTEM-1 System 1 Constant Volume Air Cooled Split System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1No. Of Units 1 Cooling System 28800.00 14.00 8.00 2 Heating System 32800.00 1.00 3 Air Handling System -Supply 947.00 0.80 4 Air Distribution System (Sup) 6.00 Eff.Inst.NoSizeCategory Equipment IPLV Plant 55/19/2020 EnergyGauge Summit® v6.10 LossEfficiencyI/P Rt.Cap.UnitCapacityW-Heater Description Water Heaters 1 Electric water heater [Gal]3 [kW]0.9700 [Ef] [Btu/h] WattageArea/Len/No. of unitsCategory Description [sf/ft/No] [W] Ext-Lighting No. of Luminaires Watts per Luminaire Control Type 1 Ext Light 1 Emergency Lighting that is automatically off during normal building operation 58.80 450.003 150 Photo Sensor control 2 Ext Light 2 Entry Canopies 33.00 28.001 28 Astronomical Timer Control 3 Ext Light 3 Canopies (freestanding, attached and Overhangs) 85.00 28.001 28 Astronomical Timer Control Insulation Thickness [in] Nomonal pipe Diameter [in] Insulation Conductivity [ Btu-in/h.sf.F] Operating Temperature [F] Type Piping Is Runout?No VLTSHGCGlass Conductance [Btu/h.sf.F] No. of Panes Glass Type Fenestration Used Name 65/19/2020 EnergyGauge Summit® v6.10 User Defined 1 1.2500 0.8200 0.7600ASHULSglClrAll Frm User Defined 2 0.5500 0.3400 0.60006068 SGD User Defined 2 0.3200 0.3000 0.5500SH25 User Defined 2 0.3200 0.3000 0.5500SH35 User Defined 2 0.3200 0.2700 0.4900SH25 W/ MULL RValue [h.sf.F/Btu] SpecificHeat [Btu/lb.F] Density [lb/cf] Conductivity [Btu/h.ft.F] Thickness [ft]DescriptionAcronymMat No Materials Used Only R-Value Used 187 Matl187 GYP OR PLAS BOARD,1/2IN 0.0417 0.0920 50.0 0.20000.4533No 178 Matl178 CARPET W/RUBBER PAD 1.2300Yes 265 Matl265 Soil, 1 ft 1.0000 0.5000 100.0 0.20002.0000No 48 Matl48 6 in. Heavyweight concrete 0.5000 1.0000 140.0 0.20000.5000No 268 Matl268 0.625" stucco 0.0521 0.4000 16.0 0.20000.1302No 42 Matl42 8 in. Lightweight concrete block 0.6670 0.3300 38.0 0.20002.0212No 269 Matl269 R-4.1 fi-foil 4.1000Yes 12 Matl12 3 in. Insulation 0.2500 0.0250 2.0 0.200010.0000No 23 Matl23 6 in. Insulation 0.5000 0.0250 5.7 0.200020.0000No 279 Matl279 Solid core flush (2.25") 2.8537Yes 81 Matl81 ASPHALT-ROOFING, ROLL 0.1500Yes 244 Matl244 PLYWOOD, 1/2IN 0.0417 0.0660 34.0 0.29000.6318No Constructs Used 1005 1 ft. soil, concrete floor 0.27 34.00 113.33 3.7 No Name Conductance [Btu/h.sf.F] Heat Capacity [Btu/sf.F] Density [lb/cf] RValue [h.sf.F/Btu] Layer Material No. Material Thickness [ft] Framing Factor No Simple Construct No Massless Construct 75/19/2020 EnergyGauge Summit® v6.10 1005 1 ft. soil, concrete floor 0.27 34.00 113.33 3.7 No Name Conductance [Btu/h.sf.F] Heat Capacity [Btu/sf.F] Density [lb/cf] RValue [h.sf.F/Btu] Layer Material No. Material Thickness [ft] Framing Factor No Simple Construct No Massless Construct 1 265 Soil, 1 ft 1.0000 0.000 2 48 6 in. Heavyweight concrete 0.5000 0.000 3 178 CARPET W/RUBBER PAD 0.000 1011 stucco /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 0.15 5.65 37.15 6.7 No Name Conductance [Btu/h.sf.F] Heat Capacity [Btu/sf.F] Density [lb/cf] RValue [h.sf.F/Btu] Layer Material No. Material Thickness [ft] Framing Factor No Simple Construct No Massless Construct 1 268 0.625" stucco 0.0521 0.000 2 42 8 in. Lightweight concrete block 0.6670 0.000 3 269 R-4.1 fi-foil 0.0625 0.000 4 187 GYP OR PLAS BOARD,1/2IN 0.0417 0.000 85/19/2020 EnergyGauge Summit® v6.10 1038 Shngl/1/2"WD Deck/WD Truss/9" Batt/Gyp Brd 0.03 1.50 8.22 31.2 No Name Conductance [Btu/h.sf.F] Heat Capacity [Btu/sf.F] Density [lb/cf] RValue [h.sf.F/Btu] Layer Material No. Material Thickness [ft] Framing Factor No Simple Construct No Massless Construct 1 81 ASPHALT-ROOFING, ROLL 0.000 2 244 PLYWOOD, 1/2IN 0.0417 0.000 3 12 3 in. Insulation 0.2500 0.000 4 23 6 in. Insulation 0.5000 0.000 5 187 GYP OR PLAS BOARD,1/2IN 0.0417 0.000 1058 Solid core flush (2.25) 0.35 2.9 No Name Conductance [Btu/h.sf.F] Heat Capacity [Btu/sf.F] Density [lb/cf] RValue [h.sf.F/Btu] Layer Material No. Material Thickness [ft] Framing Factor No Simple Construct Yes Massless Construct 1 279 Solid core flush (2.25") 0.000 95/19/2020 EnergyGauge Summit® v6.10