Loading...
HomeMy WebLinkAboutEnergy CodeBBraden & Braden, AIA, PA A040 & 9" #AA0000032 417 Coconut Ave. Stuart, FL 349969(772) 287-8258 St. Lucie County Building Dept. Wgnne Development Date: Address: \- ,�, J gC0-�-4-r�G� Permit #: r 17&c To whom it may concern. This detail applies to the insulation in the ends of the vaulted ceilings. If you have any questions please feel free to call me at 112-281-8258 WeR. Braden t Braden AIA Braden AIA PA R-19 Trusses at 24" o.c. ie shop drawings bg others ceiling transition 6'- ded using metal studs erify exact configuration :es R-30 Batts batts Drywall ceiling see typical section Gelling transition Insulation Detail nts FORM R405-2017 `FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT Street: THEISTERUNG i Permit Once: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number., Owner: \,.I, 5 0, L' 0 COn Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1442.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a; Concrete Black -lnt Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft' 3. Number of units, if multiple family 1 !_ c. N/A R= ft 4. Number of Bedrooms 2 1 d. N/A R= ft' 1 5. Is this a worst case? Yes, 10. Ceiling. Types. (1504.0 sgft.) Insulation . Area a. Under Attic (Vented) R=30.0 1474.00 ft' 6. Conditioned floor area above grade (ft� 1474 b. Knee Wall (Vented) R=19.0 30.00 ft- Conditioned floor area below grade (ft2) 0 c. NIA R= ft, 17 7. Windows(141.3 sgft) Description Area a! Sup: Attic, Rat: Attic, AH: Attic 6 175 a. U-Factor. Sgl, U=1:04 101.25 ft' SHGC: SHGC=0.29 b. U-Factor. Sgl, U=1.11 40.00 ft' 12. Cooling systems kStulhr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor. N/A ft' SHGC; 13. Heating systems kBlu/hr Efficiency d. U-Factor. WA ft' a.•ElecMcHeat Pump 34.8 HSPF:8.50, SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.284 14. Hot water systems . B. Floor Types (1473.5 sgf Insulation Area ' a. Electric Cap: 40 gallonsft.) a. Slab -On -Grade Edge Insulation R=0.0 I 1473.50 ft' b. Conservation features EF: 0.970 b. N/A R= ft2 None c. N/A R= ft2 1 15. Credits Patel Glass/Floor Area: 0.096 Total Proposed Modified, Loads: 47.97 PASS Total Baseline Loads: 48.55 I hereby certify that the plans and specifications covered by Review of the plans and 4zii6S?,g� -this calculation are in compliance with the Florida Energy specifications covered by this by #,X8p"rn Code. calculation indicates compliance �� with the Florida Energy Code. f: PREPARED BY: �1J°r - Before construction is completed od o DATE: 1-9-21] this building will be inspected for compliance with Section 553.908 - y hereby certify that this building, as designed is in compliance -Florida Statutes. with the Florida Energy Code. t''apWMF OWNER/AGE T' BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3:2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accord pA 4 A aproject requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH60 (R i�Gdd�7 CODE COMPLIANCE ST. LUCIE COUNTY BOCC 1/8/2020 4:48 PM EnergyGauge® USA 6,0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Pagel of 5 VORM R405-2017 INPUT SUMMARY' CHECKLIST REPORT PROJECT Titie: WYNNE THE STERLING IMP Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot# Owner Name: Total Stories: 1 Bldck/Subdivlsion: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING - Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdlction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Exlsting: New (From Plans) Comment: CLIMATE / •, Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range _ FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474. 11792 SPACES .Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M. BATH 56 , 448 No 0 1 Yes Yes Yes 4 'KITCHEN 192 1536 Yes 0 1 No Yes Yes . 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREATIDINING 488 .. 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space - Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet - 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 329 ft' — 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' — 0 1 0 3 Slab -On -Grade Edge Insulatio Mi BATH 8 ft 0 56 f- — 0 1 0 4SI6b-On-Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' _ 0 1 0 5Slab-0n-Grade Edge Insulatio, BATH 8ft 0 45ft' — 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' 0 1 0 7SIab-On-Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 0 1 0 1/8/2020 4:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space PerimeterPerimeter R-Value Area Joist R-Value Tile Wood Carpet 86Iab-On-Grade Edge Insulatio LAUNDRY Eft 0 42 ft' _ 0 1 0 9 Siab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft' - 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emift Emitt Deck Pitch V # Type Materials Area Area Color .Bart Absoc Tested Tested Insul. (deg) 1 Gable or Shed Metal 1553 ft' 246 ft' Light N 0.6 No 0.9 , No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1474 ft' N N CEILING # Ceiling Type Space . R-Value Ins Type Area Framing Free Truss Type _ 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft2 0.1 Wood- _ 2 Under Attic (Vented) WIC ,30 Blown 63R2 0.1 „Wood _ 3 Under Attic (Vented) M. BATH 30 Blown 56 ft' 0.1 Wood _ 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft' 0.1 Wood _ 5 Under Attie (Vented) BATH 30 Blown 45 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft' 0.1 Wood _ 7 UnderAttic (Vented) ENTRY 30 Blown 55 ft' 0.1 Wood _ 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft' 0.1 Wood _ 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft' 0.1 Wood 10 Knee Wall (Vented) BEDROOM 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below NE=>SW Exterior Concrete Block - Int InsuBEDROOM 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 _1 _ 2 SW=>NE Exterior Concrete Block - Int InsrBEDROOM 4.1 28 0 8 0 224.0 ft' 0 0 0.4 0 _ 3 NW=>SE Exterior Concrete Block- Int InsiBEDROOM 4.1 14 0 8 0 112.0 ft' 0 0 0.4 0 _ 4 SW=>NE Exterior Concrete Block- Int Insul M. BATH 4.1 8 0 8 0 64.0 ft' 0 0 0.4 0 _ 5 NE=>SW Exterior Concrete Block - Int Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 _ 6 NE=>SW Exterior Concrete Block- Int InsBEDROOM 2 4.1 16 0 8 0 128.0 ft' 0 0 0.4 0 _ 7 SE=>NW EMedor Concrete Block - Int InsHEDROOM 2 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 _ 8 S=>N Exterior Concrete Block - Int Ins6IEDROOM2 4.1 4 3 8 0 34.0 ft' 0 0 0.4 0 _ 9' SW=>NE Exterior Concrete Block- Int InSEIEDROOM 2 4.1 2 0 8 0 16.0 ft' 0 0 0.4 0 _ 10 SE=>NW Exterior - Concrete Block- Int Insul ENTRY 4.1 6 0 8 0 48.0 ft' 0 0 0.4 0 11 SW=>NE Exterior Concrete Block- Int Insul'ENTRY 4.1 1 0 8 0 8.0 IF 0 0 0.4 0 12 SW=>NE.Exterior Concrete Block - Int InSULAUNDRY 4.1 6 0 8 0 48.0 ft' 0 0 0.4 0 13 NE=>SW Exterior Concrete Block - IntlnstOREAT/DINI 4.1 26 0 8 0 208.0ft' 0 0 0.4 0 14 NW=>SE Exterior Concrete Block- Int lnsd3REAT/DINI " 4.1 20 0 8 0 160.0ft2' 0 0 0.4 0 1/8/2020 4:48 PM EnergyGaugeV USA 6:0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software I Page 3 of 5 'FORM R405-2017 INPUT SUMMARY: CHECKLIST REPORT WALLS Adjacent apace Cavity Width Height Sheathing Framing Solar Below 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft' 0.23 0.4 0 DOORS # Omt Door Type Space Storms U-Value Width Height Ft In Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 '6 8 20.6It' WINDOWS Orientation shown is the, entered orientation. => chanced to Worst Case.. Wall V # Omt -ID Frame - • Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal _ 2 SW=>NE 4 Metal _ 3 SE=>NW 7 Metal _ 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes 1.04 - 0.29 N 32.9 ft' 1 It 0In 1 ft 5 in. Drapes/blinds •1.04 0.29 N 6.9 ft' 1 It 0In 1 it 5 in None 1.04 0.29 N 24.0 ft'' 6 R 0 in 1 It 5 in None 1.04 0.29 N 37.5 ft' 1 It 0 in 1 ft 6In None 1.11 0.27 N 40.0 ft' 8 It 0 in 1 It 5 in Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315ft' 316ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1375.7 '75.53 •142.04 .1233 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split - Singi HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Black Ducts 1 Central Unit/ Split Singl SEER: 15 34.8 kBtu/tir cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage . 0.97 40 gal 60.9 gal 120 deg. 'None 1/8/2020 4:48 PM EnergyGeuge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 CORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage - Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS —Supply— —Return Air CFM 25 CFM26 HVAC# J # Location RWalue Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 175 ft2 Attic 65 ft2 Default Leakage Attic (Default) _ (Default) 1 1 TEMPERATURES Programabie Ceiling Fans: ]Thermostaf[t:'JY Heating H Jan Feb fx]'] Mar [ l ] J Apr [X] Jay un' [ ] Jul �X] 1 Aug 1X] r ] [ ] f1X,] Sep LJ Occtt Nov Nov Dec Dec Yenhng [r 11 Jan r) Feb l l rX) Mar lxl lxl May Jun [ ]Jul E 1 Aug r 1 Sep lXl [X] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 - 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 fib 66 Healing (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture. Fraction Space Default(8 lbslsgJL 0 ft2 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. 112 ft 0.3 WIC Default(8 lbs/sq.ft. ft2 ft 0.3 M. BATH_ Default(8 lbs/sq.ft. ft2 It 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 It 0.3 BATH Default(8 lbs/sq.ft. ft2 It 0.3 BEDROOM 2 Default(8 lbs/sq.fL ft2 It 0.3 ENTRY Default(8 lbslsq.fL ft2 It 0.3 LAUNDRY Default(8 16s/s.fL ft2 It 0.3 GREAT/DINING 1/8/2020 4:48 PM EnergyGaugersl.USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Owner. Jurisdiction: w Design Location: FL, Fort Pierce c=.i COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be Installed In the building. envelope. Air -permeable Insulation shall requirements re q The exterior thermal envelope'contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling /soffit Y the insulation and any gaps in the air barrieraier shall be sealetl. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall'be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between wndow/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact With the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth In unvented crawl spaces shall be covered with Where provided instead of floor Insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall -be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spar Bs. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light factures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt Insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or Insulation that on Installation readily conforms to available space shall extend behind oinino and wirina. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showersand tubs. be Insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not beusedto fill voids a. In addition, inspection or log -walls shall be In accordance witn the provisions of IcC-400. 1/8/2020 4:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0. 'c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 1474 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.060 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.284 c) Area 7c. 141.3 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior. 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 14. Heating system:- Capacity 34.8 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.97 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 1061. 11.0 10B2. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. 19.0 d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded). in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. \ Builder Signature: Date: Address of New Home: THE STERLING VD- JC'CQ"�'QA_Uc�ftity/FL Zip: FT. PIERCE, FL 1/8/2020 4:49:01 PM EnergyGauge® USA 6.0.04 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1