HomeMy WebLinkAboutEnergy CodeBraden & Braden, AIA, PA IM
aOzZP
#AAC000032
0 no-".O
417 Coconut Ave. Stuart, FL 34996•(772) 287-8258 C, W . W0.
W LU
�0
St. Lucie County Building Dept.
Wynne Development
Date: \���1��
Address. `-CA\Le \'� 'trS
Permit #: ci % A--\ .
To whom it mayconcern,
This detail applies to the insulation in
the ends of the vaulted ceilings.
If you have any questions please feel
free to call me at i"12-28-1-8258
R-19
R. Braden AIA
t Braden AIA PA
Trusses at 29" o.c.
re shop drawings bg others
ceiling transition
ided using metal studs
'erifg exact configuration
:as
R-30 Batts
-19 batts
Drywall ceding
see tgpical section
Ceiling transition Insulation Detall
nts
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: WYNNE THE GRAND CARLTON IMPPAiCT
BullderName: WYNNE BUILDING COPR.
`
Street:City,
ST. LUCIE.000NTY
State, Zip: FT. PIERCE, FL, �% �21 ``'R
PermitNu ber.
Owner: WYNNE BUILDING CROP-pQ�q,�s
Jurisdiction: ST. LUCIE COUNTY
Designi-ocation: FL, Fort Pierce o-
County: St. Lucie (Florida Climate Zone 2)
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- Int Insul, Extedor
R=4.1 1250.00ft2
b. Frame -Wood, Adjacent
R=11.0 192.00 ft2
3. Numberof units, if multiple family 1
c. NIA
R= ft2
4. Number of Bedrooms 2
d. N/A
R= 112
5. Is this a worst case? Yes
10. Celling Types (1476.0 sgft.)
Insulation Area
a. UnderAttiC(Vented)
R=30.0 1446.00 ft2
6. Conditioned floorarea above grade(fti) 1446
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area belowgrade(ft2) 0
c. NIA
R= ft2
11. Ducts
R ft2
7. Windows(141.3 sgft.) Description Area
a. Sup: Attic, Reb Attic, AH: Attic
6 175
a. U-Factor: SgI, U=1.04 101.25 ft2
SHGC: SHGC=0.29
b. U=Factor: SgI, U=1.11 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.284
14. Hotwatersystems
8. Floor Types (1445.5 sgft.) Insulation Area
a. Electric
Cap:40gallons
a. Slab -On -Grade Edge Insulation R=0.0 1445.50ft'
b. Conservation features
EF: 0.970
b. N/A R= ft'
None
c. N/A R= ft2
15.Credits
Patel
Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.50
PASS
Total Baseline Loads: 48.09
I hereby certify that the plans and specifications covered by
Review of the plans and
OF THEST,q
this calculation are in compliance with the Florida Energy
specifications covered by this
y - 90
Code.
calculation indicates compliance
Z' d
�1p
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: 1-9-2D
this building will be inspected for
compliance with Section 553.908
y n
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
!�
with the Florida Energy Code.
�''OpWE'fRs
OWNER/ATNT:
BUILDING OFFICIAL:
DATE: SI
DATE:
- Compliance requires certification by the air handler unit manufacture? tha&h02ai&ndle6g 6sJeWial1yees as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
118/2020 4:18 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) CBpllanr (eare Page 1. of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE GRAND CARLT Bedrooms: 2
Address Type:
Street Address
BuildingType: User
ConditionedArea: 1446
Lot#
OwnerName: WYNNE BUILDING CROP
Total Stories: 1
Block/Subdivision:
#of Units: 1
Worst Case: Yes
PlatBook:
BuilderName: WYNNE BUILDING COPR.
RotateAngle: 180
Street:
Permit Office: ST. LUCIE COUNTY
CrossVentilation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
FamilyType: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
_ /
Design Temp
Int Design Temp Heating
Design DailyTemp
V Designt-ocation TMY Site 97.5%
2.5%
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH_MUNI 39
90
70,
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1446 11568
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM 301
2408 No
0
1
1 Yes
Yes
Yes
2 WIC 63
504 No
0
1 No
Yes
Yes
3 M.BATH 56
448 No
0
1 Yes
Yes
Yes
4 KITCHEN 192
1636 Yes
0
1 No
Yes
Yes
5 BATH 45
360 No
0
1 Yes
Yes
Yes
6 BEDROOM 2 204
1632 No
0
1
1 Yes
Yes
Yes
7 ENTRY 55
440 No
0
1 Yes
Yes
Yes
8 LAUNDRY 42
336 No
0
1 Yes
Yes
Yes
'9 GREAT/DINING 488
3904 No
0
1 Yes
Yes
Yes
FLOORS
# FloorType
Space Perimeter PerimeterR-Value
Area
JoislR-Value
Tile Wood
Carpet
1 Slab-On-GradeEdgelnsulalion
BEDROOM 52 ft 0
301 ft'
_
0 1
0
2 Slab -On -Grade Edgelnsulation
WIC 1ft 0
63ft
_---
0 1
0
3 Slab -On -Grade Edge Insulation
M. BATH 8 ft 0
56 ft-
--__
0 1
0
4 Slab -On -Grade Edge Insulation
KITCHEN 1 ft 0
192 ft'
----
0 1
0
5 Slab -On -Grade Edge Insulation
BATH 5ft 0
45ft-
____
0 1
0
6 Slab -On -Grade Edge Insulation
BEDROOM 32.2ft 0
203.5 ft'
----
0 1
0
7 Slab -On -Grade Edge Insulation
ENTRY 7ft 0
55ft
---_
0 1
0
1/8/2020 4:18 PM EnergyGauge® USA 6.0.02 (Rev. 1) -FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# FloorType Space Perimeter PerimelerR-Value
Area
Joist R-Value
Tile Wood Carpet
8 Slab -On -Grade Edge Insulation LAUNDRY Eft
0
42 ft'
----
0
1
0
9 Slab -On -Grade Edge Insulation GREATIDINING 46ft 0
488 ft'
----
0
1
0
ROOF
/ Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 GableorShed Metal 1524 ft'
240 ft'
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V
# Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1446ft'
N
N
CEILING
# CeilingType Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 UnderAttic(Vented) BEDROOM
30
Blown
301 ft'
0.1
Wood
_ 2 UnderAltic(Vented) WIC
30
Blown
63 ft'
0.1
Wood
3 UnderAttic(Vented) M. BATH
30
Blown
56 ft'
0.1
Wood
4 UnderAttic(Vented) KITCHEN
30
Blown
192 ft'
0.1
Wood
5 UnderAttic(Vented) BATH
30
Blown
45ft
0.1
Wood
_ 6 UnderAtgc(Vented) BEDROOM
30
Blown
204 ft'
0.1
Wood
7 UnderAttic(Vented) ENTRY
30
Blown
55 ft'
0.1
Wood
8 UnderAttic(Vented) LAUNDRY
30
Blown
42ft'
0.1
Wood
9 UnderAttic(Vented) GREAT/DINING
30
Blown
488 ft'
0.1
Wood
10 Knee Wall (Vented) GREAT/DINING
19
Blown
30 ft'
0.11
Wood
WALLS
Adjacent Cavity Width
Height
Sheathing Framing Solar
Belo
Space
Et In
Ft
In
Arpa
P.Mghip. Fraction
Ahnor
w
_ 1 NE=>SW Exterior Concrete Block- Int lnsul BEDROOM
4.1 10
0 8
0
80.0 ft'
0
0
0.4
0
_ 2 SW=>NE Exterior Concrete Block- Int lnsul BEDROOM
4.1 28
0 8
0
224.0 ft'
0
0.
0.4
0
_ 3 NW=>SE Exterior Concrete Block- Int lnsul BEDROOM
4.1 14
0 8
0
112.0 ft'
0
0
0.4
0
_ 4 SW=>NE Exterior Concrete Block - Intlnsul M. BATH
4.1 8
0 8
0
64.0 ft'
0
0
0.4
0
_ 5 NE=>SW Exterior Concrete Block - Intlnsul BATH
4.1 5
0 8
0
40.0 ft'
0
0
0.4
0
6 NE=>SW Exterior Concrete Block- Int lnsuBEDROOM 2
4.1 16
0 8
0
128.0 ft'
0
0
0.4
0
7 SE=>NW Exterior Concrete Block- Int lnsuBEDROOM 2
4.1 10
0 8
0
80.0ft
0
0
0.4
0
8 S=>N Exterior Concrete Block- Int lnsuBEDROOM 2
4.1 4
3 8
0
34.0 ft'
0
0
0.4
0
_ 9 SW=>NE Exterior Concrete Block- Int lnsuBEDROOM 2
4.1 2
0 8
0
16.0 ft'
0
0
0.4
0
10 SE=>NW Exterior Concrete Block-Intlnsul ENTRY
4.1 6
0 8
0
48.0 ft'
0
0
0.4
0
11 SW=>NE Exterior Concrete Block - Intlnsul ENTRY
4.1 1
0 8
0
8.0 ft'
0
0
0.4
0
_12 SW=>NE Exterior Concrete Block-Intlnsul LAUNDRY
4.1 6
0 8
0
48.0 ft'
0
0
0.4
0
13 NE=>SW Exterior Concrete Block- Int lnsuGREATIDIN1
4.1 26
0 8
0
208.0 ft'
0
0
0.4
0
14 NW=>SE Exterior Concrete Block- Int lnsuGREATIDINI
4.1 20
0 8
0
160.0 ft'
0
0
0.4
0
118120204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition.(2017) Compliant Software Page 3of5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
15 N=>S Garage Frame -Wood
Space .Cavity Width
KITCHEN 11 24 8
Height Sheathing Framing Solar Below
192.0 ft' 0.23 0.4 0
DOORS
# Omt
DoorType
Space Storms
U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
Insulated
ENTRY None
.39 3 1
6 8
20.6 ft'
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
V # Omt ID Frame
Panes
NFRC U-Factor SHGC Imp
Overhang
Area Depth Separation IntShade
Screening
1 NW=>SE3 Metal
2 SW=>NE 4 . Metal
3 SE=>NW 7 Metal
_ 4 NE=>SW 13 Metal
5 NW=>SE14 Metal
Low-ESingle
Low-ESingle
Low-ESingle
Low-ESingle
Low-ESingle
Yes 1.04 0.29 Y
Yes 1.04 0.29 Y
Yes 1.04 0.29 Y
Yes 1.04 0.29 Y
Yes 1.11 0.27 Y
32.9 ft' 1ItOin 1ft5m
6.9 ft' 1 ft 0 in 1 ft 5 in
24.0 ft' 6 ft 0 in 1 ft 5 in
37.5 ft' 1 ft 0 in 1 ft 5 in
40.O ft' 8 ft 0 in 1 ft 5 in
Drapeslblinds
None
None
None
Drapes/blinds
Exterior5
None
None
None
Exlerior5.
GARAGE
# FloorArea
Ceiling Area Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1 315ft'
315 ft' 24ft
8ft
11
INFILTRATION
# Scope Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse ProposedACH(50)
.000366 1349.6 74.09 139.34 .1233
7
HEATING SYSTEM
# System Type
Subtype Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split Single HSPF:8.5
34.8 kBtulhr
1
sys#1
COOLING SYSTEM.
# System Type
Subtype Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split Single SEER: 15
34.8 kBtu/hr cfm
0'.8 1
sys#1
HOTWATER SYSTEM
# System Type
SubType
Location EF Cap
Use SetPnt
Conservation
1 Electric
None
Garage 0.97 40gal 60.9gal 120deg
None
1/8/20204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4of5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart# CompanyName
System
Model#
CollectorModel#
Area Volume
FEF
None None
ft=
DUCTS
—Supply—
—Return—
Air
.CFM 25 CFM25
HVAC#
V # Location R-Value Area
Location
Area
LeakageType
Handler
TOT OUT ON
RLF
Heal Cool
1 Attic
6 175 ft'
Attic
65 ft=
Defaultleakage
Attic
.(Default) c(Default) c
1 1
TEMPERATURES
ProgramableThermostat: Y
Cffeiling Fans:
HeaOng [X]Jan txl Feb
f 1]
(X]Mar
IMay
rj Jun
fX1
[ ]Jul
1
4XT Aug
fX1
[
j
)Sep LJ
HNov
Venting [[ ]]Jan [[ ]]Feb
I[�Xl]Mar
Apr
[
Jun
[ ]Jul
(]Aug
[
]Sep lxl Oct
Dec
ThennostatSchedule: HERS 2006
Reference
Hours
ScheduleType
1
2
3
4
5
6
7
8
9 10
11
12
Cooling(WD) AM
78
78
78
78
78
78
78
78
80 80
60
80
-PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling(WEH) AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating(WD) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68.
68
68
68 68
66
66
Heating(WEH) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
FumitureFraction
Space
Default(Blbs/sq.ft
0 ft-
0 ft
0.3
BEDROOM
Default(81bs/sq.ft.
ft-
ft
0.3
WIC
Default(8lbs/sq.fL
ft-
ft
0.3
M. BATH
Default(81bs/sq.ft
ft-
ft
0.3
KITCHEN
Default(Blbs/sq.ft
ft
ft
0.3
BATH
Default(8lbs/sq.fL
ft-
ft
0.3
BEDROOM 2
Default(8lbs/sq.ft.
ft-
ft
0.3
ENTRY
Default(81bs/sq.ft
ft-
ft
0.3
LAUNDRY
Default Blbs/s .ft.
ft'
ft
0.3
GREATIDINING
118/20204:18 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition.(2017) Compliant Software Page 5of5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
w
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceilinglattic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
,shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
'
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
pncluding
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation Installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, Insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned spare shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spar
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shallbeairtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind ninino and wirina
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
ElectricaVphone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
beh8men Jim jpd13kIpr cover plates and walls or ceilinas
a. In addition,inspection of log walls shall be in accordance with the provisions of ICC-400.
1/8/2020 4:19 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEERICOP
6. Conditioned floor area (sq. ft.)
6.
1446
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.060
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.284
14. Heating system: Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c,
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type.and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a.
30.0
b) Cross ventilation.
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
19.0
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: 4'� Date:
Address of New Home���\�-rC��S City/FL Zip:FT. PIERCE. FL
1/8/2020 4:19:34 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1