HomeMy WebLinkAboutEnergy CodeBBraden & Braden, AIA, PA
A40 Y" #AAC000032
417 Coconut Ave. Stuart, FL 34996•(772) 287-8258
St. Lucie Countg Building Dept.
Wynne Development
Date:
Address:
Permit U: n I
lk-
To whom it may concern,
This detail applies to the insulation it
the ends of the vaulted ceilings.
If you have ang questions please feel
free to call me at '112-281-8258
R-19
Sinc el
Dane Braden AIA
Braden E Braden AIA PA
Trusses at 24" o.c.
W shop drawings bg others
ceiling transition 6�
ded using metal studs
erifg exact configuration
:es
W
cc Z
LL Z
J 6
a �, [L°v
W U U m
jLIJM
W
�O�-
O�
R-30 Batts
9 batts
Drywall ceding
see typical section
nts
d
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE MANOR IMPACT
Builder Name: WYNNE BUILDING CORP.
^
Street: THE MANOR 71 /'_ \\�
�� V zJ
Permit Office: ST. LUCIE COUNTY
City, Stale, Zip: FT. PIERCE, FL,
Permit Number:
Owner: WYNNE BUILDING CORP.
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1654.2 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1374.20 ft2
b. Frame - Wood, Adjacent
R=11.0 280.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. NIA
R= ft2
10. Ceiling Types (1754.0 sgft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1724.00 ft2
6. Conditioned floor area above grade (ft2) 1724
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (ft2) 0
c. NIA
R= ft2
11. Ducts
R ft2
7. Windows(153.4 sqR.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 150
a. U-Factor. Sgi, U=1:04 113.35 ft2
SHGC: SHGC=0.29
b. U-Factor. Sgl, U=1.11 40.00 ft2
12. Cooling systems
kBtulhr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor. WA ft2
SHGC:
13. Heating systems
kBtulhr Efficiency
d. U-Factor. NIA ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.010 ft.
Area Weighted Average SHGC: 0.285
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1723.5 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Ede Insulation R=0.0 1723.50 ft2
9
b. Conservation features
b. N/A R= ft2
None
c. NIA R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 53.45
Glass/Floor Area: 0.089
PASS
PASS
Total Baseline Loads: 54.12
1 hereby certify that the plans and specifications covered by
Review of the plans and
F S53> ST,q?
this calculation are in compliance with the Florida Energy
specifications covered by this
♦O .' __ 1 �O
Code.
calculation indicates compliance
�p
with the Florida Energy Code.
4 ni, `O
PREPARED BY: ty� `' -
Before construction is completed
DATE: ,-9-20
this building will be inspected for
compliance with Section 553.908
O Y
s a =
I hereby certify that this building, as designed J I' nce
Florida Statutes.
with the Florida Energy Code.
4
WE
�-
OWNER/AG T:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403:3:2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
REVIEWED FOR
CODE COMPLIANCE
1/8/2020 4:31 PM EhergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edi8'F01L i?EES J a NTY Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNETHEMANOR IMPA
Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1724
Lot#
Owner Name: WYNNE BUILDING CORP.
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING CORP.
Rotate Angle: 270
Sheet:
THE MANOR 71
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Ebsting: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating Design Daily Temp
V Design Location TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name Area
Volume
'
1 Entire House 1724
14774.8
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
. Heated
1 GREAT ROOM 546
5350.8 No
0
1
Yes
Yes
Yes
2 MASTER BEDROO 354
2832 No
2
1
1
Yes
Yes
Yes
3 WIC 77
616 No
0
1
No
Yes
Yes
4 CLST. 35
280 No
0
1
No
Yes
Yes
5 M BATH 54
432 No
0
1
Yes
Yes
Yes
6 KITCHEN 180
144o Yes
0
1
Yes
Yes
Yes
7 JUNIOR M. BED 198
1584 No
0
1
1
Yes
Yes
Yes
8 BATH 50
400 No
0
1
No
Yes
Yes
9 POWDER 35
280 No
0
1
Yes
Yes
Yes
10 NOOK 42
336 No
0
1
Yes
Yes
Yes
11 LAUNDRY 49
392 No
0
1
Yes
Yes
Yes
12 ENTRY 104
832 No
0
1
Yes
Yes
Yes
FLOORS
# Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
TIIe Wood
Carpet
1 Slab -On -Grade Edge Insulatio GREAT
ROOM 47 ft 0
546 W
—
0 1
0
2SIab-On-Grade Edge Insulatio MASTER BEDRO 46 ft 0
354V
—
0 1
0
3SIab-On-Grade Edge Insulatio WIC 1 ft 0
77 ft'
_
0 1
0
4SIab-On-Grade Edge Insulatio CLST. 1 ft 0
35 ft'
_
0 1
0
5 Slab -On -Grade Edge Insulatio M BATH 911 0
54 fl'
_
0 1
0
1/812020 4:31 PM EnergyGauge®.USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R406-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
6SIab-On-Grade Edge Insulatio
KITCHEN 11 ft
0
180 ft2
_
0 1
0
7SIab-On-Grade Edge Insulatio
JUNIOR M. BED 14 ft
0
198 ft2
_
0 1
0
8 Slab -Orr -Grade Edge Insulatio
BATH 1 ft
0
50 ft'
__
0 1
0
9 Slab -On -Grade Edge Insulatio
POWDER 5 ft
0
35 ft2
_
0 1
0
10SIab-On-Grade Edge Insulatio
NOOK 6 ft
0
42 ft'
_
0 1
0
11SIab-On-Grade Edge Insulatio
LAUNDRY 17 ft
0
49 ft2
_
0 1
0
12SIab-On-Grade Edge Insulatio
ENTRY 5.9 ft
0
103.5 ft2
--
0 1
0
ROOF
/
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip
Metal 1817 ft2
0 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC.
/
V
# Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
300
1724 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Free Truss Type
1 Under Attic (Vented)
GREAT ROOM
30
Blown
546 ft2
0.1
Wood
2 Under Attic (Vented)
MASTER BEDRO
30
Blown
354 ft2
0.1
Wood
3 Under Attic (Vented)
WIC
30
Blown
77 IF
0.1
Wood
4 Under Attic (Vented)
CLST.
30
Blown
35 ft2
0.1
Wood
5 Under Attic (Vented)
M BATH
30
Blown
54 ft2
0.1
Wood
_
6 Under Attic (Vented)
KITCHEN
30
Blown
180 ft2
0.1
Wood
_
7 Under Attic (Vented)
JUNIOR M. BED
30
Blown
198 ft2
0.1
Wood
8 Under Attic (Vented)
BATH
30
Blown
50 ft2
0.1
Wood
9 Under Attic (Vented)
POWDER
30
Blown
35 ft'
0.1
Wood
10 Under Attic (Vented)
NOOK
30
Blown
42 f12
0.1
Wood
11 Under Attic (Vented)
LAUNDRY
30
Blown
49 ft'
0.1
Wood
12 Under Attic (Vented)
ENTRY
30
Blown
104 ft'
0.1
Wood
13 Knee.Wall (Vented)
GREAT ROOM
19
Blown
30 ft'
0.11
Wood
WALLS
Adjacent
Space Cavity Width
Height
Sheathing Framing Solar
Below
0
_ 1
SW=>SE Exterior Concrete Block - Int InsGIREAT ROO
4.1 26
0 9
10
255.7 ft2
0
0 0.3
0
_ 2
NW=>S Exterior Concrete Block - Int InsGREAT ROO
4.1 21
0 9
10
206.5 112
0
0 0.3
0
3
NE=>NW Exterior Concrete Block - Int InsWASTER BE
4.1 25
0 8
0
200.0 112
0
0 0.3
0
1/8/2020 4:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 61h Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space
Cavity Width
Height
Sheathing Framing
Solar
Below
-4 SW=>SE Exterior
Concrete Block- Int InstJASTER BE
4.1 8
0
8 0
64.0 ft'
0
0
0.3
0
_ 5 NW=>S Exterior
Concrete Block - Int InsftlASTER BE
4.1 13
0
8 0
104.0 ft-
0
0
0.3
0
-6 NE=>NW Exterior
Concrete Block- Int Insul M BATH
4.1 9
0
8 0
72.0 ft'
0
0
0.3
0
-7 SW=>SE Exterior
Concrete Block- Int InsulKITCHEN
4.1 11
0
8 0
88.0 ft'
0
0
0.3
0
-8 NE=>NW Exterior
Concrete Block- Int InsdUNIOR M. B
4.1 14
0
8 0
112.0 ft'
0
0
0.3
0
_ 9 SW=>SE Exterior
Concrete Block- Int InsuIPOWDER
4.1 5
0
8 0
40.0 ft'
0
0
0.3
0
_ 10 SW=>SE Exterior
Concrete Block- Int Insul NOOK
4.1 6
0
8 0
48.0 ft'
0
0
0.3
0
11 NE=>NW Exterior
Concrete Block - Int InsuLAUNDRY
4.1 3
0
8 0
24.0 ft2
0
0
0.3
0
12 SE=>NE Exterior
Concrete Block- Int InsuLAUNDRY
4.1 7
0
8 0
56.0 ft2
0
0
0.3
0
13 SW=>SE Exterior
Concrete Block- Int InsuLAUNDRY
4.1 7
0
8 0
56.0 ft2
0
0
0.3
0
_ 14 SE=>NE Exterior
Concrete Block- Int Insul ENTRY
4.1 6
0
8 0
48.0 ft2
0
0
0.3
0
15 N=>W Garage
Frame -Wood ENTRY
11 35
8
280.0 ft2
0.23
0.3
0
DOORS
# Omt
Door Type Space
Stones
U-Value
Ft
Width
In
Height
Ft In
Area
1 SE=>NE Insulated ENTRY
None
.32
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
Overhang
V # Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 SW=>SE 1
Metal Low-E Single Yes
1.04 0.29
N
46.4 ft2
1 ft 0 in
1 ft 5 in
None
None
2 NW=>SW 2
Metal Low-E Single Yes
1.11 0.27
N
40.0 ft'
8 It 0 in
1 ft 5 in
None
None
3 NW=>SW 5
Metal Low-E Single Yes
1.04 0.29
N
32.4 ft2
1 ft 0 in
1 ft 5 in
None
None
4 NE=>NW 6
Metal Low-E Single Yes
1.04 0.29
N
6.9 112
1 ft 0 in
1 ft 5 in
None
None
5 NE=>NW 8
Metal Low-E Single Yes
1.04 0.29
N
16.2 ft2
1 ft 0 in
1 ft 5 in
None
None
6 SW=>SE 9
Metal Low-E Single Yes
1.04 0.29
N
6.9 112
1 It 0 in
1 ft 5 in
None
None
7 SE=>NE 12
Metal Low-E Single Yes
1.04 0.29
N
4.7 ft2
7 ft 0 in
1 ft 5In
None
None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 440 ft2 440 ft2
35 It
8
ft
11
INFILTRATION
# Scope Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000272 1231.2 67.59
127.12
.097
5
1/812020 4:31 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
None
Singl HSPF:8.5
34.8 kStu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 34.8 kBtulhr 1044 cfm
0.85 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use
SelPnt
Conservation
1 Electric None
Garage
0.95 50 gal 60.9 gal
120 deg
- None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
— Supply —
— Return—
Alr
CFM 25
CFM25
HVAC #
J # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT ON RLF
Heat Cool
1 Attic 6 150 ft2
Attic
45 ft2 Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programablre T]hermostaf[t:,]Y
Crreiling Fans:
[[ ]]
Heating Jan Feb [X] Mar
Apr
[[XX]]
Jun I) Jul
May rj
[[XX]]
t) Aug
[X]
[ ] Sep
j N
rIX'I
Oct Nov
Dec
Venting [ I Jan O Feb [X) Mar
l l l l
[
Jun (1 Jul
l 1 Aug
[) Sep
�jj]
lxl
lXl [X]
Dec
Thermostat Schedule: HERS 2006 Reference
Hours '
Schedule Type 1
2 3
4 5 6
7
8
9
10 11
12
Cooling (4VD) AM 78
78 78
78 78 78
78
78
80
80 80
80
PM 80
80 78
78 78 78
78
78
78
78 78
78
Cooling (WEH) AM 78
78 78
78 78 78
78
78
78
78 78
78
PM 78
78 78
78 78 78
78
78
78
78 78
78
Heating (WD) AM 66
66 66
66 66 68
68
68
68
68 68
68
PM 68
68 68
68 68 68
68
68
68
68 66
66
Heating (WEH) AM 66
66 66
66 66 68
68
68
68
68 68
68
PM 68
68 .68
68 68 68
68
68
68
68 66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 lbs/sq.ft.
0 ft2
- 0 ft
0.3
BEDROOM
Default(8 lbs/sq.fL
ft2
ft
0.3
WIC
Default(8 lbs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8 lbs/sq.fL
ft2
ft
0.3
_
KITCHEN
Default(8 lbs/sq.fL
112
ft
0.3
BATH
Default(8 lbslsq.fL
ft2
ft
0.3
BEDROOM 2
Default(8 lbslsq.ft.
ft2
ft
0.3
ENTRY
Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
118/2020 4:31 PM EnergyGauge®-USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
1/8/2020 4:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2D17 FBC 6lh Edition (2017) Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE MANOR IMPACT Builder Name: WYNNE BUILDING CORP.
Street: THE MANOR 71 Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number.
Owner: WYNNE BUILDING CORP. Jurisdiction:
m
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation In an dropped soffit
y PP ceilin 9/
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barter.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be Insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be Installed In substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity Insulation shall be installed to
(including
Insulation.
maintain permanent contact with the underside of
above -garage
subfioor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be In contact with the top side
ROOTS)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures Installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs,
be Insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
I
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover i2lates and walls or ceilings I
a. in audition, mspecuan of iog wars span be in accomance win me provisions or lug uu.
1/8/2020 4:36 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1724
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor.(weighted average)
7a.
1.058
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.285
14. Heating system: Capacity
34.8
c) Area
7c.
153.4
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
0 Other
8.50
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
15. Water heating system
a) Electric resistance EF 0.95
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
f) Heat recovery unit HeatRec%
g) Other
10131.
11.0
10132.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a.
30.0
b) Cross ventilation No
11b.
c) Whole house fan No
11c.
19.0
d) Multizone cooling credit
11d.
No
e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features. \ '7 \ \
Builder Signature: �- - Date: �\ �,�, `�v
Address of New Home: THE MANOR 71 `'D, v��� City/FL Zip: FT. PIERCE. FL -SS 'T SJ
1/8/2020 4:36:22 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1