Loading...
HomeMy WebLinkAboutBoral Self Adhered Underlayment PA BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL14317-R10 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Boral Roofing / MonierLifetile Address/Phone/Email 7575 Irvine Center Drive Suite 100 Irvine, CA 92618 (602) 269-2288 Ext 8320 thomas.jemmett@boral.com Authorized Signature Thomas Jemmett thomas.jemmett@boral.com Technical Representative Adrian Cooper Address/Phone/Email 135 NW 20th Street Boca Raton, FL 33431 (954) 520-5461 acoopeer@minierlifetile.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Robert J. M. Nieminen Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/21/2020 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL14317_R10_COI_2018_01_COI_NIEMINEN.pdf Referenced Standard and Year (of Standard)Standard Year ASTM D1970 2015 FRSA/TRI (April 2012) 04-12 2012 UL 1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/12/2018 Date Validated 10/15/2018 Date Pending FBC Approval 10/22/2018 Date Approved 12/11/2018 Summary of Products FL #Model, Number or Name Description 14317.1 Boral Roof Underlayments Roof underlayments for use in prepared roof assemblies Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-210 Other: 1.) The design pressure in this application pertains to a particular underlayment system for use under foam-on tile systems. Refer to ER Section 5.6.4. 2.) Refer to ER Section 5 for Limits of Use. Installation Instructions FL14317_R10_II_2018_10_FINAL_ER_BORAL_Underlayments_FL14317- R10.pdf Verified By: Robert J. M. Nieminen PE - 59166 Created by Independent Third Party: Yes Evaluation Reports FL14317_R10_AE_2018_10_FINAL_ER_BORAL_Underlayments_FL14317- R10.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: NEOREcta. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION REPORT Boral Roofing 7575 Irvine Center Drive, Suite 100 Irvine, CA. 92618 (602) 269-2288 Evaluation Report M35710.12.10-R11 FL14317-R10 Date of Issuance: 12/21/2010 Revision 11: 10/12/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Boral Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words “NEMO|etc. Evaluated” may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 10/12/2018. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing produ cts for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. NEMO|etc. NEMO ETC, LLC Evaluation Report M35710.12.10-R11 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10 Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 2 of 8 ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Uplift UL 1897 2012 1507.1.1, T1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 (04-12) 2012 3. REFERENCES: Entity Examination Reference Date ERD (TST 6049) Physical Properties M36790.07.11 09/30/2011 ERD (TST 6049) Physical Properties B40380.08.12 08/28/2012 ERD (TST 6049) Tensile Adhesion / LTA C41420.09.12-2 09/11/2012 ERD (TST 6049) Adhesion B41940.09.12 09/13/2012 ERD (TST 6049) Tensile Adhesion / LTA B47390.07.14-1 07/31/2014 ERD (TST 6049) Tensile Adhesion / LTA B47390.09.14 09/04/2014 OC (PDM1838) Physical Properties Equivalency statement 11/02/2017 PRI (TST 5878) ASTM D1970 NEI-031-02-02:REV 10/27/2010 PRI (TST 5878) ASTM D1970 NEI-029-02-01:REV 12/03/2010 PRI (TST 5878) Tensile Adhesion / LTA NEI-046-02-01REV 12/17/2010 PRI (TST 5878) FRSA/TRI April 2012 NEI-076-02-01 02/14/2011 PRI (TST 5878) ASTM D1970 NEI-034-02-02 01/29/2013 PRI (TST 5878) Wind Uplift BORR-001-02-01 03/17/2015 PRI (TST 5878) Wind Uplift BORR-005-02-01 06/24/2015 PRI (TST 5878) Tensile Adhesion / LTA DAPF-002-02-01 03/08/2018 PRI (TST 5878) ASTM D1970 (adhesion) OCF-443-02-01 10/11/2018 UL, LLC. (QUA 9625) Quality Assurance Service Confirmation Exp. 08/21/2020 4. PRODUCT DESCRIPTION: 4.1 Boral® TileSeal 50HT is a nominal 50-mil thick, polyester-surfaced, self-adhering SBS modified bitumen roof underlayment; meets ASTM D1970. 4.2 Boral® TileSealHT is a nominal 60-mil thick, polyester-surfaced, self-adhering SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI 04-12. 4.3 Boral® MetalSealHT is a nominal 60-mil thick, polyester-surfaced, self-adhering SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI 04-12. 4.4 GatorSeal® is a nominal 55-mil thick, granular-surfaced, fiberglass reinforced, self-adhering SBS modified bitumen roof underlayment; meets ASTM D1970. 4.5 Citadel® Plus is a nominal 48-mil thick, fabric-surfaced, fiberglass reinforced, self-adhering SBS modified bitumen roofing underlayment for use as a base-layer in multi-ply underlayment systems; meets ASTM D1970. NEMO|etc. NEMO ETC, LLC Evaluation Report M35710.12.10-R11 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10 Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 3 of 8 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by-itself beneath the stated roof covers. Refer to the installation instructions for multi-ply underlayment options. TABLE 1: ROOF COVER OPTIONS Underlayment Asphalt Shingles Nail-On Tile Adhesive-set Tile Metal Wood Shakes & Shingles Slate Boral TileSeal 50HT Yes No No Yes Yes Yes Boral TileSealHT Yes Yes Yes (See 5.5.1) Yes Yes Yes Boral MetalSealHT Yes Yes Yes (See 5.5.1) Yes Yes Yes GatorSeal Yes No No No Yes Yes 5.5.1 “Adhesive-set Tile” is limited to use of following Approved tile adhesives / underlayment combinations. TABLE 1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS1 Adhesive Florida Product Approval Underlayments DAP Foam Touch ‘n Seal StormBond Roof Tile Adhesive FL14506 Boral TileSealHT or Boral MetalSealHT DAP Foam Touch ‘n Seal StormBond 2 Two-Component Polyurethane Roof Tile Adhesive FL21374 Boral TileSealHT or Boral MetalSealHT Dow TILE BOND™ Roof Tile Adhesive FL22525 Boral TileSealHT or Boral MetalSealHT ICP Adhesives Polyset® AH-160 FL6332 Boral TileSealHT or Boral MetalSealHT ICP Adhesives Polyset® RTA-1 FL6276 Boral TileSealHT or Boral MetalSealHT 1 Refer to Tile Manufacturer’s or Adhesive Manufacturer’s Florida Product Approval for Overturning Moment Resistance Performance. NEMO|etc. NEMO ETC, LLC Evaluation Report M35710.12.10-R11 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10 Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 4 of 8 5.6 Allowable Substrates: 5.6.1 Direct-Bond to Deck: Citadel Plus, Boral TileSeal 50HT, Boral TileSealHT, Boral MetalSealHT or GatorSeal: ➢ Plywood (unprimed or primed with ASTM D41 primer). Boral TileSealHT or Boral MetalSealHT: ➢ OSB (unprimed or primed with ASTM D41 primer). Note: Refer to Section 5.6.4 for uplift limitations associated with direct-deck underlayment installations where the overlying roof cover is adhesive-set tile roofing 5.6.2 Bond to Base Layer Underlayment: Citadel Plus, Boral TileSeal 50HT, Boral TileSealHT, Boral MetalSealHT or GatorSeal: ➢ ASTM D226, Type II felt; Citadel Plus. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under adhesive-set tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC 1504.3.1. 5.6.3 Bond to Other Substrate Types: Citadel Plus, Boral TileSeal 50HT, Boral TileSealHT, Boral MetalSealHT or GatorSeal: ➢ ASTM D41 primed metal (e.g., flashing metal, valley metal, etc.). Boral TileSealHT: ➢ Huber Zip Deck (unprimed or primed with ASTM D41 primer); Dens Deck Prime. Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer’s Product Approval. 5.6.4 Wind Resistance for Underlayment Systems in Adhesive-set Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath adhesive-set tile systems, where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in adhesive-set tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads #1 Maximum Design Pressure = -120.0 post: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 to the plywood deck Base Ply: Citadel Plus, self-adhered Cap Sheet: Boral TileSealHT or Boral MetalSealHT, self-adhered, and back-nailed within the selvedge-edge side laps using 12 ga. x 1¼” ring shank nails through 32 ga., 1-5/8” diameter tin caps spaced 12-inch o.c. #2 Maximum Design Pressure = -142.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Ply: None Cap Sheet: Boral TileSealHT or Boral MetalSealHT, self-adhered and back-nailed within the selvedge-edge side laps using 12 ga. x 1¼” ring shank nails through 32 ga., 1-5/8” diameter tin caps spaced 12-inch o.c. NEMO|etc. NEMO ETC, LLC Evaluation Report M35710.12.10-R11 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10 Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 5 of 8 #3 Maximum Design Pressure = -202.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Tropical Roofing Products #410 Quick Dry Primer or other ASTM D41 primer to the plywood deck Base Ply: None Cap Sheet: Boral TileSealHT or Boral MetalSealHT, self-adhered, and back-nailed within the selvedge-edge side laps using 12 ga. x 1¼” ring shank nails through 32 ga., 1-5/8” diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure = -210.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: KARNAK #89 Sta-Tak Primer to the plywood deck Base Ply: None Cap Sheet: Boral TileSealHT or Boral MetalSealHT, self-adhered, and back-nailed within the selvedge-edge side laps using 12 ga. x 1¼” ring shank nails through 32 ga., 1-5/8” diameter tin caps spaced 12-inch o.c. #5 Maximum Design Pressure = -120.0 psf: Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: ASTM D41 to the concrete deck Base Ply: (Optional) Citadel Plus, self-adhered Cap Sheet: Boral TileSealHT or Boral MetalSealHT, self-adhered 5.6.4.1 Note: For adhesive-set tile systems, if there is a base ply or mid-ply of Citadel Plus in the system, the project design pressure requirements may not exceed -120 psf. 5.7 Exposure Limitations: GatorSeal shall not be left exposed for longer than 30-days after installation, prior to placement of final roof cover. Boral TileSeal 50HT, Boral TileSealHT or Boral MetalSealHT shall not be left exposed for longer than 180-days after installation, prior to placement of final roof cover. Citadel Plus, for use as a base-layer in a multi-ply underlayment system, shall not be left exposed for longer than 180-days after installation, prior to placement of subsequent underlayment layer. 5.8 Tile Slippage Limitations [FRSA/TRI April 2012 (04-12)]: When loading roof tiles on the underlayment in direct-deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Boral TileSealHT or Boral MetalSealHT Flat Max. 10-tile stack 6:12 Lugged Max. 10-tile stack 6:12 6. INSTALLATION: 6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Install self-adhering underlayment when ambient and surface temperatures are minimum 40°F and rising. NEMO|etc. NEMO ETC, LLC Evaluation Report M35710.12.10-R11 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10 Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 6 of 8 6.4 Citadel Plus: 6.4.1 Citadel Plus is limited to use as a base or mid-layer in multi-ply underlayment systems beneath Boral TileSeal 50HT, Boral TileSealHT or GatorSeal. 6.4.2 Slope limitations are those associated with the top-layer underlayment. 6.4.3 Direct to Deck: Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by ¼-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the top edge of the sheet to the deck with corrosion resistant roofing nails, nails & tin-tags or 1-inch diameter plastic or steel cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the black-selvedge area, minimum 2 inches (horizontal lap) and minimum 6” end (vertical) laps. Install final underlayment layer atop Citadel Plus per ‘direct-to-deck’ instructions for Boral TileSeal 50HT, Boral TileSealHT, Boral MetalSealHT or GatorSeal. 6.4.4 To Base Sheet: Install base sheet of ASTM D226, Type II felt in accordance with Code requirements or install base ply of Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4.3 and when used as part of a multi-ply system. Install optional Citadel Plus as a mid-ply in accordance with Boral Roofing published installation instructions and Section 6.4.3. Install final underlayment layer atop Citadel Plus per ‘direct-to-deck’ instructions for Boral TileSeal 50HT, Boral TileSealHT or GatorSeal. Note: For adhesive-set tile systems, if there is a base ply or mid-ply of Citadel Plus in the system, the project design pressure requirements may not exceed -120 psf. 6.5 Boral TileSeal 50HT: 6.5.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.5.2 Do not use Boral TileSeal 50HT on roof pitches less than 2:12. 6.5.3 Non-Tile Applications, Direct to Deck: Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by ¼-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails & tin-tags or 1-inch diameter plastic or steel cap nails spaced maximum 24-inch o.c. for slopes below 7:12 and maximum 12-inch o.c. for slopes 7:12 and greater. Overlap successive courses the entire width of the black-selvedge area, minimum 3-inch. Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam method detailed in Boral Roofing published installation instructions. NEMO|etc. NEMO ETC, LLC Evaluation Report M35710.12.10-R11 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10 Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 7 of 8 6.5.4 Non-Tile Applications, to Base Sheet: Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install Boral TileSeal 50HT in accordance over ASTM D226, Type II felt or Citadel Plus with Boral Roofing published installation instructions and Section 6.5.3, except end (vertical) laps, described below. Apply SBS Mastic under all end (vertical) laps or any other laps where the self-adhering bituminous underside is in contact with the fabric top surface, rolling the interface into place with a weighted roller. 6.6 GatorSeal: 6.6.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.6.2 Do not use GatorSeal on roof pitches less than 2:12. 6.6.3 Non-Tile applications, Direct to Deck: Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by ¼-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails & tin-tags or 1-inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and greater. Overlap successive courses the entire width of the black-selvedge area, minimum 3-inch. Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self-adhering bituminous underside is in contact with the granular or mineral top surface, rolling the interface into place with a weighted roller, or using the Inverted Sheet Seam detailed in Boral Roofing published installation instructions. 6.6.4 Non-Tile Applications, to Base Sheet: Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install GatorSeal over ASTM D226, Type II felt or Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.6.3 except end (vertical) laps, described below. Apply SBS Mastic under all side (vertical) laps or any other laps where the self-adhering bituminous underside is in contact with the granular top surface, rolling the interface into place with a weighted roller. 6.7 Boral TileSealHT or Boral MetalSealHT: 6.7.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.7.2 Do not use Boral TileSealHT or Boral MetalSealHT on roof pitches less than 2:12. 6.7.3 Non-Tile Applications, Direct to Deck: For OSB substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by ¼-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the black selvedge edge to the deck with roofing nails, nails & tin-tags or 1-inch diameter plastic or steel cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the black-selvedge area, minimum 3-inch. Seal under all end (vertical) laps using approved mastic or use Inverted Sheet Seam method detailed in Boral Roofing published installation instructions. NEMO|etc. NEMO ETC, LLC Evaluation Report M35710.12.10-R11 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10 Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 8 of 8 6.7.4 Non-Tile Applications, to Base Sheet: Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install Boral TileSealHT or Boral MetalSealHT over ASTM D226, Type II felt or Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.7.3, except end (vertical) laps, described below. Apply SBS Mastic under all end (vertical) laps or any other laps where the self-adhering bituminous underside is in contact with the fabric top surface, rolling the interface into place with a weighted roller. 6.7.5 Tile Applications: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self-adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1. For adhesive-set tile applications, refer to Section 5.6.4 herein. Note: For adhesive-set tile systems, if there is a base ply or mid-ply of Citadel Plus in the system, the project design pressure requirements may not exceed -120 psf. Refer to Section 5.8 for tile staging limitations. Battens must be used for all tile installations atop Boral TileSealHT or Boral MetalSealHT with roof pitches of 2½ to less than 3:12. Boral Roofing’s Elevated Batten System or counter battens are required. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Brentwood, NH 9. QUALITY ASSURANCE ENTITY: UL, LLC. – QUA9625; (631) 546-2458; Kanchi.Agrawala-Dokania@ul.com - END OF EVALUATION REPORT -