Loading...
HomeMy WebLinkAboutEnergy CodeBBraden & Braden, AIA, PA ALF I" #AAC000032 417 Coconut Ave. Stuart, FL 34996 • (772) 287-8258 St. Lucie County Building Dept. Wynne Development Date: Address: Permit #: To whom it mag concern. This detail applies to the insulation in the ends of the vaulted ceilings. If you have any questions please feel free to call me at 112-281-8258 R-19 DMQI R. Braden AIA Braden t Braden AIA PA Trusses at 24" o.c. .e shop drawings bg others ceding transition �� ded using metal studs erify exact configuration :as lu 0 W 0 C LU3 0 R-30 Batts batts Drywall ceding see tgpical section Ceiling transition Insulation Detail nts• FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT -Street THE STERLING Permit Office: ST. LUCIE COUNTY City, Slate, Zip: FT. PIERCE, FL, Permit Number: Owner. (. �p��l 9 G Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or eAsting. New (From Plans) 9. Wall Types(1442.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Int Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. WA R= ft2 5. Is this a worst case? ye5� 10. Ceiling Types (1504.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft2 6. Conditioned floor area above grade (ft2) 1474' b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 11. Ducts R ft2 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 175 a. U-Factor: Sgl, U=1.04 101.25 ft2 SHGC: SHGC=0.29 b. U-Factor. Sgl, U=1.11 40.00 112 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor. NIA ft2 SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor. N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: , 3.832 ft. Area Weighted Average SHGC: 0.284 14. Hot water systems 8. Floor Types (1473.5 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2 i b. Conservation features EF: 0.970 b. NIA R= ft2 None c. NIA R= ft2 15. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 47.97 PASS Total Baseline Loads: 48.55 I hereby certify that the plans and specifications covered by Review of the plans and fiiES? .this calculation are in compliance with the Florida Energy specifications covered by this O Code. calculation indicates compliance h'' '°.,s• with the Florida Energy Code. 16 PREPARED By: -ahAo Before construction is completed r DATE: 1-9-20 this building will be inspected for compliance with Section 553.908 LD hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNERIAGEt -� BUILDING OFFICIAL: DATE: DATE: I. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed In accordance with' 11403.3:2,1. - Compliance requires an Air Barrier and Insulation Inspection Checklistin accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). .� • CODE COMPLIANCE ST. LUCIE COUNTY .1/8/2020 4:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant SottwarOOCC Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE STERLING IMP Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot# Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: _Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie _Permit Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE. Family Type: Single-family FL, New/E)dsting: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design DailyTemp V Design Location TMY Site 97.5 % 2.6 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 LOW BLOCKS Number Name Area Volume 1 Entire House 1474, 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes. Yes 3 M. BATH 56 448 No 0 1 Yes .Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No 'Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 It 0 329 ft — 0 1 0 2SIab-On-Grade Edge Insulatio ;WIC t It 0 63ft' _ 0 1 0 3 Slab -On -Grade Edge Insulatio M! BATH 8 ft 0 56 ft' — 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 It 0 192 fN _ 0 1 0 5SIab-On-Grade Edge Insulatio i BATH 5-11 0 45 ft' — 0 1 0 6SIab-On-Grade Edge Insulatio { BEDROOM 2 32.2 ft 0 203.¢ft' _ 0 1 0 7SIab-On-Grade Edge Insulatio ENTRY 7ft 0 66ft' _ 0 1 0. 118Q020 4:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Pedmeter R-Value Area Joist R-Value Tile Wood Carpet. 8SIab-On-Grade Edge Insulatio LAUNDRY Eft 0 42 ft2 _ 0 1 0 9SIab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0 488 112 _ 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emift Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1553 ft' 246 112 Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1474 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft' 0.1 Wood _ 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood _ 3 Under Attic (Vented) M. BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood _ 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft' 0.1 Wood _ 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood _ 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood _ 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood 10 Knee Wall (Vented) BEDROOM 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 NE=>SW Exterior Concrete Block- Int InsuBEDROOM 4.1 10 0 8 0 80.0 112 0 0 0.4 0 _ 2 SW=>NE Exterior Concrete Block - Int InsLMEDROOM 4.1 28 0 8 0 224.0 ft' 0 0 0.4 0 _ 3 NW=>SE Exterior Concrete Block - Int InsiBEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 _ 4 SW=>NE Exterior Concrete Block - Int Insul M. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 5 NE=>SW Exterior Concrete Block- Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 _ 6 NE=>SW Exterior Concrete Block - Int InsBEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 _ 7 SE=>NW Exterior Concrete Block - Int InsBEDROOM 2 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 8 S=>N Exterior Concrete Block - Int InsBEDROOM 2 4.1 4 3 8 0 34.0 ft2 D 0 0.4 0 _ 9 SW=>NE Exterior Concrete Block- Int InsBEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 _ 10 SE=>NW Exterior Concrete Block- Int Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 _ 11 SW=>NE Exterior Concrete Block - Int Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 12 SW=>NE Fxtedor Concrete Block- Int Insul AUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 13 NE=>SW Exterior Concrete Block- Int lns0REAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.4 •0 14 NW=>SE Exterior Concrete Block - Int InstOREAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 1/8/2020 4A8 PM EnergyGauge® USA 6:0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software I Page 3 of 5 FORM R405-2017 INPUT SUMMARY: CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing 'Solar Below 0 15 N=>S Garage Frame -Wood KITCHEN 11 24 8 192.0ft' 0.23 0.4 0 DOORS # Omt Door Type Space Storm's U-Value Width Height Ft In Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. _ / Wall V # Omt ID Frame Panes Overhang NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal _ 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low•E Single Low-E Single Yes 1.04 0.29 N 32.9 ft' 1 ft 0 in 1 ft 5 in Drapeslblinds Yes 1.04 0.29 N 6.9 ft- 1 ft 0 in 1 ft 5In None Yes 1.04 0.29 N 24.0 ft' 6 ft 0 in 1 ft 5 in None Yes 1.04 0.29 N 37.5 ft' 1 It 0In 1 ft 5,In None .Yes 1.11 0.27 N 40.0 ft' 8 it 0 in 1 ft 5In Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 31511' 315ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA- CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1375.7 75.53 142.04 .1233 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 34.8 kBtulhr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage . 0.97 40 gal 60.9 gal 120 deg None -1/812020 4:48 PM EnergyGauge® USA 6.0:02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / — Supply — Return Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 175 ft' Attic 65 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre TJhermosta[[t:]]Y Ceiling Fans: HeatiDec ng Jan pq Feb [[ j] LXl Mar M Apr May May Jun r ).Jun J IlIX l Jul Aug f[r` ]J Sep fr� rD0' Octct Nov r1X'I Dec Venting [)Jan [[ 11 Feb l l l[�X1) Mar [ ] Jun [ Lxl lxj [X]. [ ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM. 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 fib 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft' 0 ft 0.3 BEDROOM Default(8 lbslsq.ft. ft' ft 0.3 WIC Default(8 lbs/sq.fL ft' ft 0.3 M. BATH Default(8 lbslsq.ft. ft' ft 0.3 KITCHEN Default(8 lbs/sq.fL ft ft 0.3 BATH Default(8 lbs/sq.fL ft' ft 0.3 BEDROOM 2 Default(8 lbs/sq.fL ft' ft 0.3 ENTRY Default(8 lbs/sq.fL ft' ft 0.3 LAUNDRY Default(8 lbs/s.ft. ft' ft 0.3 GREAT/DINING 1/8/2020 4:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: Jurisdiction: w Design Location: FL, Fort Pierce x� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The Insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame wails The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. " Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be Installed at any exposed edge of Floor framing cavity insulation shall be Installed. to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity Insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space wails Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac Bs. Recessed lighting Recessed light fixtures Installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind olnina and witina. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on extertorwall tubs shall separate them from the showers and tubs. be Insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or alr-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voidsnkler cover plates and walls or ceifinag. Ins a. in aactuon, Inspection or tog waus snan Be in accoraance with the provisions or IG(J-000, •11812020 4".49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 'c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Coaling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1474 d) Room unif/PTAC EER e) Other 7. Windows, type and area a) U-factor.(weighted average) 7a. 1.060 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.284 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor.(weighted average) 8a. NA 'd) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11c. 19.0 d) Multizone cooling credit d) Radiant barrier installed lid. -No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT 1 certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) -in this. home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. l`\ Builder Signature: Date: Address of New Home: THE STERLING \�c 1:1 �q,11 ty/FL Zip: _ FT. PIERCE. FL .1/8/2020 4:49:01 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1