HomeMy WebLinkAboutEnergy CodeBBraden & Braden, AIA, PA
ALF I" #AAC000032
417 Coconut Ave. Stuart, FL 34996 • (772) 287-8258
St. Lucie County Building Dept.
Wynne Development
Date:
Address:
Permit #:
To whom it mag concern.
This detail applies to the insulation in
the ends of the vaulted ceilings.
If you have any questions please feel
free to call me at 112-281-8258
R-19
DMQI R. Braden AIA
Braden t Braden AIA PA
Trusses at 24" o.c.
.e shop drawings bg others
ceding transition ��
ded using metal studs
erify exact configuration
:as
lu
0
W 0
C
LU3
0
R-30 Batts
batts
Drywall ceding
see tgpical section
Ceiling transition Insulation Detail
nts•
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE STERLING IMPACT
Builder Name: WYNNE DEVELOPMENT
-Street THE STERLING
Permit Office: ST. LUCIE COUNTY
City, Slate, Zip: FT. PIERCE, FL,
Permit Number:
Owner. (. �p��l 9
G
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or eAsting. New (From Plans)
9. Wall Types(1442.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- Int Insul, Exterior
R=4.1 1250.00 ft2
b. Frame - Wood, Adjacent
R=11.0 192.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. WA
R= ft2
5. Is this a worst case? ye5�
10. Ceiling Types (1504.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1474.00 ft2
6. Conditioned floor area above grade (ft2) 1474'
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (ft2) 0
c. NIA
R= ft2
11. Ducts
R ft2
7. Windows(141.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U-Factor: Sgl, U=1.04 101.25 ft2
SHGC: SHGC=0.29
b. U-Factor. Sgl, U=1.11 40.00 112
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor. NIA ft2
SHGC:
13. Heating systems
kBtulhr Efficiency
d. U-Factor. N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: , 3.832 ft.
Area Weighted Average SHGC: 0.284
14. Hot water systems
8. Floor Types (1473.5 sgft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2
i
b. Conservation features
EF: 0.970
b. NIA R= ft2
None
c. NIA R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.096 Total Proposed Modified Loads: 47.97
PASS
Total Baseline Loads: 48.55
I hereby certify that the plans and specifications covered by
Review of the plans and
fiiES?
.this calculation are in compliance with the Florida Energy
specifications covered by this
O
Code.
calculation indicates compliance
h'' '°.,s•
with the Florida Energy Code.
16
PREPARED By: -ahAo
Before construction is completed
r
DATE: 1-9-20
this building will be inspected for
compliance with Section 553.908
LD
hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
OWNERIAGEt -�
BUILDING OFFICIAL:
DATE:
DATE:
I.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed In accordance with' 11403.3:2,1.
- Compliance requires an Air Barrier and Insulation Inspection Checklistin accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
.� •
CODE COMPLIANCE
ST. LUCIE COUNTY
.1/8/2020 4:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant SottwarOOCC Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE STERLING IMP Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1474
Lot#
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
_Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180
Street:
THE STERLING
Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
_Permit
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE.
Family Type: Single-family
FL,
New/E)dsting: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Heating
Design DailyTemp
V Design Location
TMY Site 97.5 % 2.6 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH MUNI 39 90
70
75 299
62
LOW
BLOCKS
Number Name
Area Volume
1 Entire House
1474, 11792
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM
329 2632 No 0
1
1 Yes
Yes
Yes
2 WIC
63 504 No 0
1 No
Yes.
Yes
3 M. BATH
56 448 No 0
1 Yes
.Yes
Yes
4 KITCHEN
192 1536 Yes 0
1 No
'Yes
Yes
5 BATH
45 360 No 0
1 Yes
Yes
Yes
6 BEDROOM 2
204 1632 No 0
1
1 Yes
Yes
Yes
7 ENTRY
55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY
42 336 No 0
1 Yes
Yes
Yes
9 GREAT/DINING
488 3904 No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 52 It 0
329 ft
—
0 1
0
2SIab-On-Grade Edge Insulatio
;WIC t It 0
63ft'
_
0 1
0
3 Slab -On -Grade Edge Insulatio
M! BATH 8 ft 0
56 ft'
—
0 1
0
4 Slab -On -Grade Edge Insulatio
KITCHEN 1 It 0
192 fN
_
0 1
0
5SIab-On-Grade Edge Insulatio
i
BATH 5-11 0
45 ft'
—
0 1
0
6SIab-On-Grade Edge Insulatio
{
BEDROOM 2 32.2 ft 0
203.¢ft'
_
0 1
0
7SIab-On-Grade Edge Insulatio
ENTRY 7ft 0
66ft'
_
0 1
0.
118Q020 4:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Pedmeter R-Value
Area
Joist R-Value
Tile
Wood Carpet.
8SIab-On-Grade Edge Insulatio LAUNDRY Eft 0
42 ft2
_
0
1
0
9SIab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0
488 112
_
0
1
0
ROOF
/ Roof
Gable
Roof
Red
Solar
SA Emitt
Emift Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Gable or Shed Metal 1553 ft'
246 112
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V
# Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1474 ft'
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
329 ft'
0.1
Wood
_ 2 Under Attic (Vented) WIC
30
Blown
63 ft'
0.1
Wood
_ 3 Under Attic (Vented) M. BATH
30
Blown
56 ft'
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
_ 5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft'
0.1
Wood
_ 7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
_ 8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
_ 9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
10 Knee Wall (Vented) BEDROOM
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar
Below
_ 1 NE=>SW Exterior Concrete Block- Int InsuBEDROOM
4.1 10
0 8
0
80.0 112
0
0
0.4
0
_ 2 SW=>NE Exterior Concrete Block - Int InsLMEDROOM
4.1 28
0 8
0
224.0 ft'
0
0
0.4
0
_ 3 NW=>SE Exterior Concrete Block - Int InsiBEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
_ 4 SW=>NE Exterior Concrete Block - Int Insul M. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
5 NE=>SW Exterior Concrete Block- Int Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.4
0
_ 6 NE=>SW Exterior Concrete Block - Int InsBEDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.4
0
_ 7 SE=>NW Exterior Concrete Block - Int InsBEDROOM 2
4.1 10
0 8
0
80.0 ft'
0
0
0.4
0
8 S=>N Exterior Concrete Block - Int InsBEDROOM 2
4.1 4
3 8
0
34.0 ft2
D
0
0.4
0
_ 9 SW=>NE Exterior Concrete Block- Int InsBEDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.4
0
_ 10 SE=>NW Exterior Concrete Block- Int Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
_ 11 SW=>NE Exterior Concrete Block - Int Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.4
0
12 SW=>NE Fxtedor Concrete Block- Int Insul AUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
13 NE=>SW Exterior Concrete Block- Int lns0REAT/DINI
4.1 26
0 8
0
208.0 ft2
0
0
0.4
•0
14 NW=>SE Exterior Concrete Block - Int InstOREAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.4
0
1/8/2020 4A8 PM EnergyGauge® USA 6:0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software I Page 3 of 5
FORM R405-2017 INPUT SUMMARY: CHECKLIST REPORT
WALLS
Adjacent
Space Cavity Width Height Sheathing Framing 'Solar Below
0
15 N=>S Garage Frame -Wood
KITCHEN 11 24 8 192.0ft' 0.23 0.4
0
DOORS
# Omt
Door Type
Space Storm's U-Value Width Height
Ft In Ft In
Area
1 SE=>NW
Insulated
ENTRY None .39 3 1 6 8
20.6 ft'
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
_ / Wall
V # Omt ID Frame
Panes
Overhang
NFRC U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
_ 4 NE=>SW13 Metal
5 NW=>SE14 Metal
Low-E Single
Low-E Single
Low-E Single
Low•E Single
Low-E Single
Yes 1.04 0.29 N 32.9 ft' 1 ft 0 in 1 ft 5 in Drapeslblinds
Yes 1.04 0.29 N 6.9 ft- 1 ft 0 in 1 ft 5In None
Yes 1.04 0.29 N 24.0 ft' 6 ft 0 in 1 ft 5 in None
Yes 1.04 0.29 N 37.5 ft' 1 It 0In 1 ft 5,In None
.Yes 1.11 0.27 N 40.0 ft' 8 it 0 in 1 ft 5In Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 31511'
315ft' 24ft 8ft 11
INFILTRATION
# Scope Method
SLA- CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1375.7 75.53 142.04 .1233 7
HEATING SYSTEM
# System Type
Subtype Speed Efficiency Capacity Block
Ducts
1 Electric Heat Pump/
Split Singl HSPF:8.5 34.8 kBtulhr 1
sys#1
COOLING SYSTEM
# System Type
Subtype Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split Singl SEER: 15 34.8 kBtulhr cfm 0.85 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location EF Cap Use SetPnt Conservation
1 Electric
None
Garage . 0.97 40 gal 60.9 gal 120 deg None
-1/812020 4:48 PM EnergyGauge® USA 6.0:02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System
Model #
Collector Model
# Area Volume
FEF
None None
ft'
DUCTS
/ — Supply
—
Return
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage
Type
Handler
TOT
OUT ON RLF
Heat Cool
1 Attic
6 175 ft'
Attic
65 ft'
Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programablre TJhermosta[[t:]]Y
Ceiling Fans:
HeatiDec
ng Jan pq Feb
[[ j]
LXl Mar
M Apr
May
May
Jun
r ).Jun
J IlIX
l Jul
Aug
f[r` ]J
Sep
fr� rD0'
Octct
Nov
r1X'I
Dec
Venting [)Jan [[ 11 Feb
l l
l[�X1) Mar
[ ] Jun
[
Lxl
lxj [X].
[ ]
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling (WEH) AM.
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating (WD) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
fib 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbs/sq.ft.
0 ft'
0 ft
0.3
BEDROOM
Default(8 lbslsq.ft.
ft'
ft
0.3
WIC
Default(8 lbs/sq.fL
ft'
ft
0.3
M. BATH
Default(8 lbslsq.ft.
ft'
ft
0.3
KITCHEN
Default(8 lbs/sq.fL
ft
ft
0.3
BATH
Default(8 lbs/sq.fL
ft'
ft
0.3
BEDROOM 2
Default(8 lbs/sq.fL
ft'
ft
0.3
ENTRY
Default(8 lbs/sq.fL
ft'
ft
0.3
LAUNDRY
Default(8 lbs/s.ft.
ft'
ft
0.3
GREAT/DINING
1/8/2020 4:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT
Street: THE STERLING Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
Owner: Jurisdiction:
w
Design Location: FL, Fort Pierce
x�
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The Insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame wails
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum. "
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be Installed at any exposed edge of
Floor framing cavity insulation shall be Installed. to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity Insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space wails
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Bs.
Recessed lighting
Recessed light fixtures Installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind olnina and witina.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on extertorwall
tubs shall separate them from the showers and tubs.
be Insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or alr-sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voidsnkler cover plates and walls or ceifinag.
Ins
a. in aactuon, Inspection or tog waus snan Be in accoraance with the provisions or IG(J-000,
•11812020 4".49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
'c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Coaling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1474
d) Room unif/PTAC EER
e) Other
7. Windows, type and area
a) U-factor.(weighted average)
7a.
1.060
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.284
14. Heating system: Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor.(weighted average)
8a.
NA
'd) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
19.0
d) Multizone cooling credit
d) Radiant barrier installed
lid.
-No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
1 certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) -in this. home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features. l`\
Builder Signature: Date:
Address of New Home: THE STERLING \�c 1:1 �q,11 ty/FL Zip: _ FT. PIERCE. FL
.1/8/2020 4:49:01 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1