HomeMy WebLinkAboutGas PipingBOARD OF
COUNTY
COMMISSIONERS
GAS PIPING SCHEMATIC
PLANNING & DEVELOPMENT
SERVICES DEPARTMENT
Building and Code Regulation
Division
TANK SIZE: ysp GALS. QXI Sfi G '
APPLICANCE — TYPEISIZE J
Al C 1 3 BTU
A2 BTU
A3 BTU
A4 BTU
A5 BTU
A6 BTU
PIPING LENGTH & SIZE_ (PIPE SIZE WAS tN FROM
L1 FT. r� CH DIA. THE 2014 FBCFUEL GAS CODE -
L2 '1 FT. I L INCH DIA. TABLE402(_�)
L3 FT. INCH DIA.
L4 FT. INCH DIA.
L5 FT. INCH DIA.
L6 FT. INCH DIA.
L7 FT, INCH DIA.
LS FT. INCH DIA.
L9 FT. INCH DIA.
LID FT. INCH DIA.
1-11 FT, INCH DIA.
L12 FT. INCH DIA.
Website: www stlucieco.00v
2300 Virginia Avenue - Fart Pierce, FL. 34982-5662 _
Phone (772) 462-1553 FAX (772) 462-1578
Revised 7/22/14
Copyright 2014 National Fire Preledon Association (NFPA). Licensed, by agreement, for Individual use and download on December 4,Pl4 o AMERIGAS PROPANE for designalad user JESSICA BOOTH. No ather
reproduction or transmission in any farm permitted without wdaan permission of NFPA. For inquires at 10 �ndunautbodzed use, m.MCI licensing®nfpa.org.
PIPE AND TUBING SIZING TABLES - 58-91
TSble 15.1(f) Pipe Sizing Between First -Stage and
SecondStage Regulators: Outside Diameter Copper Tubing,
Type K
Gas: Undiluted Propane
Inlet Pressure: 10.0 psi
Pressure Drop:. 1.0 psi
Specific Gravity: 1.52
Tubing
Length
% in.
, t7/2 in.
s/y in.
a/4 in.
r/s hr.
(ft)
0.305
0.402
0.527
0.652
0.745
30
284
587
1193
2085
2959
40
243
502
1021
1785
2532 -
50
216
445
905
1582
2244
60
195
403
820
1433
2033
70
180
371 -
754
1319
1871
80
167
345
702
1227
1740
90
157
374
659
1151
1633
100
148
306
622
1087
1542
150
119
246
500
873
1239
200
102
210
428
747
1060
250
90
186
379
662
940
300
82
169
343
600
851
350
75
155
316
552
783
400
70
144
294 "
514
729
450
66
136
276
482
654
500
62
128
260
455
646
600
56
116
236
412
585
700
52
107
217
379
538
800
48
99
202
353
501
900
45
93
189
331
470
1000
43
88
179
313
444
1500
34
71
144
251
356
2000
29
60
123
215
305'
Nates:
(1) Capacities are in 1000 Btu/lur.
(2) To convert to capacities at a gauge pressure of 5 psi setting with
10 percent (0a psi) pressure drop, multiply values by 0.666. To con-
vert to capacities at a gauge pressure of 15 psi setting with 10 percent
(1.5 psi) pressure drop.. multiply values by 1.350.
Table 15.1(g) Copper 7Lbe Sizing Between Second -Stage
Regulator and 4111suce: Outside Diameter Copper Tubing,
Type K
Gas: Undiluted Propane
Inlet Pressure: 11 in. w.c.
Pressure Drop: 0.5 in.
Specific Gravity: 1.52
Tubing
Length
%d.
1/4 in.
s/a in.
a/4 in.
"/a in.
(ft)
0.315
0.402
0.527
0.652
0.745
10
44
93
188
329
467
20
31
64
129
226
321
30
Z
51
104
182
258
40
21
44
89
1.56
221
50
b
39
79
138
196
60
11
35
71
125
177
80
I1
30
61 -
107
152
100
11
27
54
95
134
125
11
24
48
84
119
150
10
21.
44
76
108
200
1
18
37
65
92
250
B
16
33
58
82
300.
1
15
30
52
74
350
7
14
28
48
68
400
- 6
13
26
45
63
Note: Capacities ae in 1000 Btu/hr
2014 Edition n
Quality Steel Corporation AG/UG Propane tanKI
a -NTH
14.-.1 r, ;:IJC tIF
.-11h11 e111GIIMCCCI nuIFNSInNSAMD SPECIFICATIONS
APPROXIMAItAtwVtun
tvu/ur+vuanv�.�t-
WEIGHT
**QUANTITY
WATER
DIAMETER
HEAD
OVERALL
OVERALL
, LEG*
LEG'
CAPACITY
(OD)
TYPE
LENGTH
HEIGHT
WIDTH
SPACING
(lbs.)
FULLLOAD
PERSTACK
*120wg.
24"
Ellip.
5'-8"
3'
1'-11/2"
2'-101(2"
260
108 196
16112
or 3'11"
*250 wg.
30"
Hemi.
7'-10"
3'-S"
1'-5"
4'-71"
480
54
9
*320wg.
30"
Hemi.
9'=7"
3'-8"
1'-5"
5'
620
45
9
500 wg.37
1 2"
41"
emf.
Hemi.
16'
-
4'-5"
1'-S"
10' 1"
1,800
17 15
6 5
1000 wg..
1450w6
461/2"
Ellip.
17'-4"
4'-11"
1'-9"
11'7"
2,650
12
4
.
1990wg.
461/2"
Ellip.
23'-11"
4'-11"
3,520
8
4
Dimensions and specifications shown are approximate. Individual vessels may vary.
'Leg spacing +j- 2". Leg widths and spacing may vary based on mfg. location. Check with your salesperson for details. 120,250,320 wg. standard tanks
-no holes in legs (one center hole on request). Soo and 1000 wg. standard tanks- 2 holes 16" on center. 1450 wg. and up as shown above.
-- Full load and stack quantities vary by shipping location. Check with your salesperson for details.
General Specifications
- Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, section VIII, Division 1.
Complies with NFPA 58.
Rated at 250 psig from -20" F to 125° F. All vessels registered with National Board.
-Two serviceoptions available:
option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish
or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite
AG/UG dome.
Option 2: Aboveground option, coated with either powder coated TGIC polyester finish or liquid
applied epoxy primer coat followed by urethane topcoat, supplied with steel AG/UG dome.
All vessels are shipped vacuum pre -purged to enable simplified first fill of the vessel.
Updated June 30, 2015
AmeriGas is pleased to offer the following proposal for your consideration:
Michael and Nancy Kenny
7934 Steeplechase Ct
sired
Port Saint Lucie, FL 34986
City, Stole. Zip Code
Bruce Coberly
Sales Rep asentelive
Ft. Pierce
District Location
772-971-8092
Telephone
)"calloft of work: Tee into existing high pressure gas line to add generator line to existing propane system
]uanti 1DDescription Unit Cost Total
'
i
0�11ch
1
$69.99
1 lCopper to Poly trans
65
$65.00
riser
95
-tog A0
$ter
u
10
$5000ok
Off
1 S=nd stage regulator
25
$25.00
95
$95.00
1 lRegulator venting material
75
$75.00
1 Permit
300
$300.00
AX
7.00"%
68.43
prices are exclusive of anyapplieabls taxes, plumbingand eWftal Wft
TOTAL COST =
$1 015.41
prices are Caused on a standard installation. Unrweseen circumstances such as poor 101 condition, premature Installation or concrals, landscaping, she otmk
may result In increased costs. Change orders must be approved prior to kistellalion and are subject to approval by the authodty having jurisdiction. AmerlGam
rN sot be myonsift tordeme," to anme ked MM &artnkle . watt, eleabk etc ).
_L WORK SHALL BE PERFORMED ACCORDING TO FEDERAL, STATE AND LOCAL REQUIREMENTS.
tachments:
. 1 f n i o�7 Bruce Coberty
P by Date Submitted by. Date 5!5!2020
This proposal Is valid ror 30 days from the date submitted.