Loading...
HomeMy WebLinkAboutGas PipingBOARD OF COUNTY COMMISSIONERS GAS PIPING SCHEMATIC PLANNING & DEVELOPMENT SERVICES DEPARTMENT Building and Code Regulation Division TANK SIZE: ysp GALS. QXI Sfi G ' APPLICANCE — TYPEISIZE J Al C 1 3 BTU A2 BTU A3 BTU A4 BTU A5 BTU A6 BTU PIPING LENGTH & SIZE_ (PIPE SIZE WAS tN FROM L1 FT. r� CH DIA. THE 2014 FBCFUEL GAS CODE - L2 '1 FT. I L INCH DIA. TABLE402(_�) L3 FT. INCH DIA. L4 FT. INCH DIA. L5 FT. INCH DIA. L6 FT. INCH DIA. L7 FT, INCH DIA. LS FT. INCH DIA. L9 FT. INCH DIA. LID FT. INCH DIA. 1-11 FT, INCH DIA. L12 FT. INCH DIA. Website: www stlucieco.00v 2300 Virginia Avenue - Fart Pierce, FL. 34982-5662 _ Phone (772) 462-1553 FAX (772) 462-1578 Revised 7/22/14 Copyright 2014 National Fire Preledon Association (NFPA). Licensed, by agreement, for Individual use and download on December 4,Pl4 o AMERIGAS PROPANE for designalad user JESSICA BOOTH. No ather reproduction or transmission in any farm permitted without wdaan permission of NFPA. For inquires at 10 �ndunautbodzed use, m.MCI licensing®nfpa.org. PIPE AND TUBING SIZING TABLES - 58-91 TSble 15.1(f) Pipe Sizing Between First -Stage and SecondStage Regulators: Outside Diameter Copper Tubing, Type K Gas: Undiluted Propane Inlet Pressure: 10.0 psi Pressure Drop:. 1.0 psi Specific Gravity: 1.52 Tubing Length % in. , t7/2 in. s/y in. a/4 in. r/s hr. (ft) 0.305 0.402 0.527 0.652 0.745 30 284 587 1193 2085 2959 40 243 502 1021 1785 2532 - 50 216 445 905 1582 2244 60 195 403 820 1433 2033 70 180 371 - 754 1319 1871 80 167 345 702 1227 1740 90 157 374 659 1151 1633 100 148 306 622 1087 1542 150 119 246 500 873 1239 200 102 210 428 747 1060 250 90 186 379 662 940 300 82 169 343 600 851 350 75 155 316 552 783 400 70 144 294 " 514 729 450 66 136 276 482 654 500 62 128 260 455 646 600 56 116 236 412 585 700 52 107 217 379 538 800 48 99 202 353 501 900 45 93 189 331 470 1000 43 88 179 313 444 1500 34 71 144 251 356 2000 29 60 123 215 305' Nates: (1) Capacities are in 1000 Btu/lur. (2) To convert to capacities at a gauge pressure of 5 psi setting with 10 percent (0a psi) pressure drop, multiply values by 0.666. To con- vert to capacities at a gauge pressure of 15 psi setting with 10 percent (1.5 psi) pressure drop.. multiply values by 1.350. Table 15.1(g) Copper 7Lbe Sizing Between Second -Stage Regulator and 4111suce: Outside Diameter Copper Tubing, Type K Gas: Undiluted Propane Inlet Pressure: 11 in. w.c. Pressure Drop: 0.5 in. Specific Gravity: 1.52 Tubing Length %d. 1/4 in. s/a in. a/4 in. "/a in. (ft) 0.315 0.402 0.527 0.652 0.745 10 44 93 188 329 467 20 31 64 129 226 321 30 Z 51 104 182 258 40 21 44 89 1.56 221 50 b 39 79 138 196 60 11 35 71 125 177 80 I1 30 61 - 107 152 100 11 27 54 95 134 125 11 24 48 84 119 150 10 21. 44 76 108 200 1 18 37 65 92 250 B 16 33 58 82 300. 1 15 30 52 74 350 7 14 28 48 68 400 - 6 13 26 45 63 Note: Capacities ae in 1000 Btu/hr 2014 Edition n Quality Steel Corporation AG/UG Propane tanKI a -NTH 14.-.1 r, ;:IJC tIF .-11h11 e111GIIMCCCI nuIFNSInNSAMD SPECIFICATIONS APPROXIMAItAtwVtun tvu/ur+vuanv�.�t- WEIGHT **QUANTITY WATER DIAMETER HEAD OVERALL OVERALL , LEG* LEG' CAPACITY (OD) TYPE LENGTH HEIGHT WIDTH SPACING (lbs.) FULLLOAD PERSTACK *120wg. 24" Ellip. 5'-8" 3' 1'-11/2" 2'-101(2" 260 108 196 16112 or 3'11" *250 wg. 30" Hemi. 7'-10" 3'-S" 1'-5" 4'-71" 480 54 9 *320wg. 30" Hemi. 9'=7" 3'-8" 1'-5" 5' 620 45 9 500 wg.37 1 2" 41" emf. Hemi. 16' - 4'-5" 1'-S" 10' 1" 1,800 17 15 6 5 1000 wg.. 1450w6 461/2" Ellip. 17'-4" 4'-11" 1'-9" 11'7" 2,650 12 4 . 1990wg. 461/2" Ellip. 23'-11" 4'-11" 3,520 8 4 Dimensions and specifications shown are approximate. Individual vessels may vary. 'Leg spacing +j- 2". Leg widths and spacing may vary based on mfg. location. Check with your salesperson for details. 120,250,320 wg. standard tanks -no holes in legs (one center hole on request). Soo and 1000 wg. standard tanks- 2 holes 16" on center. 1450 wg. and up as shown above. -- Full load and stack quantities vary by shipping location. Check with your salesperson for details. General Specifications - Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, section VIII, Division 1. Complies with NFPA 58. Rated at 250 psig from -20" F to 125° F. All vessels registered with National Board. -Two serviceoptions available: option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite AG/UG dome. Option 2: Aboveground option, coated with either powder coated TGIC polyester finish or liquid applied epoxy primer coat followed by urethane topcoat, supplied with steel AG/UG dome. All vessels are shipped vacuum pre -purged to enable simplified first fill of the vessel. Updated June 30, 2015 AmeriGas is pleased to offer the following proposal for your consideration: Michael and Nancy Kenny 7934 Steeplechase Ct sired Port Saint Lucie, FL 34986 City, Stole. Zip Code Bruce Coberly Sales Rep asentelive Ft. Pierce District Location 772-971-8092 Telephone )"calloft of work: Tee into existing high pressure gas line to add generator line to existing propane system ]uanti 1DDescription Unit Cost Total ' i 0�11ch 1 $69.99 1 lCopper to Poly trans 65 $65.00 riser 95 -tog A0 $ter u 10 $5000ok Off 1 S=nd stage regulator 25 $25.00 95 $95.00 1 lRegulator venting material 75 $75.00 1 Permit 300 $300.00 AX 7.00"% 68.43 prices are exclusive of anyapplieabls taxes, plumbingand eWftal Wft TOTAL COST = $1 015.41 prices are Caused on a standard installation. Unrweseen circumstances such as poor 101 condition, premature Installation or concrals, landscaping, she otmk may result In increased costs. Change orders must be approved prior to kistellalion and are subject to approval by the authodty having jurisdiction. AmerlGam rN sot be myonsift tordeme," to anme ked MM &artnkle . watt, eleabk etc ). _L WORK SHALL BE PERFORMED ACCORDING TO FEDERAL, STATE AND LOCAL REQUIREMENTS. tachments: . 1 f n i o�7 Bruce Coberty P by Date Submitted by. Date 5!5!2020 This proposal Is valid ror 30 days from the date submitted.