Loading...
HomeMy WebLinkAboutConstruction PlansPLAN KEY PV-1 COVER PAGE PV-2 SITE PLAN PV-3 PANEL SPECIFICATION PV-3.1 PANEL LOAD TESTING RESULTS PV-3.2 INVERTER SPECIFICATION PV-3.3 COMBINER BOX SPECIFICATION PV-3.4 ]UNCTION BOX SPECIFICATION PV-3.5 SEALANT SPECIFICATION PV-3.6 CONDUIT SUPPORT SPECIFICATION PV-3.7 ATTACHMENT DETAIL PV-3.8 STRUCTURAL CALCULATION PV-4 THREE LINE DIAGRAM PV-4.1 ELECTRICAL NOTES PV-4.2 EQUIPMENT LABELS PV-5 STRUCTURAL CERTIFICATION BUILDING INFORMATION/B.O.M. # STORIES 1/15 ROOF AREA 4457.450195 P.V. AREA 722 ROOFING TYPE ASPHALT SHINGLES ROOF PITCH 15 # RAILS 33 # L-FOOT ATTACHMENTS 131 # MODULES 40 #INVERTERS 40 # SKIRTS 17 # ENPHASE COMBINER BOXES 1 EATON 100A FUSIBLE SOLAR AC DISCONNECT 1 70A FUSES 2 125A LINE TAPS 2 SYSTEM INFORMATION MODULE LG LG 350N1C-V5 INVERTER ENPHASEIQ7PLUS-72-2-US RACKING SNAPNRACK ULTRA RAIL SYSTEM 2-RAIL SYSTEM SIZE (DC) 14 KW LOCATION 27.3206448,-80.3362590 0 LG LG 350N1C-V5 350 WATT MODULE 66.4" X 40" X 1.57L' (SEE DATASHEET) GENERAL NOTES: FILE C®Pv ST.LUCIEcoUNTY RECEIVED PLAN REVIEW JAN 15 `9?I BLDG: DATEST. LUCI6 COU(ItY, Pgrm"I"no ELE- DATE:j:2ku PLUMB: THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM D004-5�RDS FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-10, 6TH EDITION 2017 FLORIDA REMD84IIAL CODE, 6TH EDITION 2011 FLORIDA BUILDING CODE, 6TH EDITION 2017 FLORIDA FIRE PREVENTION QP%E, NEC 2014 AND ALL LOCAL CODES & ORDINANCES. ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE SOLAR EQUIPMENT. INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF FOR SLOPED ROOF AND NO MORE THAN 10-INCHES ABOVE THE SURFACE OF THE ROOF FOR FLAT ROOF. ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A PLUMBING PERMIT AND INSPECTION. ALL DESIGN, CALCULATIONS ARE PERFORMED BY DANIEL DUNZIK REGISTERED ARCHITECT. FLORIDA STATE STATUTE 471.003(3) PROVIDES THAT LICENSED ARCHITECTS ARE EXEMPTED FROM THE PROVISIONS OF CHAPTER 471 ENGINEERING AND NOT PRECLUDED FROM PERFORMING ENGINEERING SERVICES FOR INTEGRATED SYSTEMS AND SERVICES THAT ARE INCIDENTAL TO THE DESIGN CONSTRUCTION OR ALTERATION OF BUILDINGS AND STRUCTURES FOR HUMAN HABITATION. INVERTER PLACEMENT: SYSTEM UTILIZES "ENPHASE" MICRO -INVERTERS WITH RAPID SHUTDOWN CONTROL LOCATED ON THE BACK SIDE OF EACH MODULE. STRUCTURAL STATEMENT: THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE SYSTEM INCLUDING UPLIFT & SHEAR. EXISTING RAFTER SIZES & DIMENSIONS CONFORM TO 6TH EDITION 2017 FLORIDA RESIDENTIAL CODE, 6TH EDITION 2017 FLORIDA BUILDING CODE SECTION 1512 THROUGH 1525 AND SECTION 1616 THROUGH 1626 FOR HIGH VELOCITY HURRICANE ZONES, FSEC CERTIFICATION STATEMENT: PER FL. STATUE 377.705 (REVISED 7/1/2017), I, MINA A. MAKAR PE# 86753, Certiflcate of Authorization #33404, AN ENGINEER LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBI- 2017 ® momentum SOLAR PRO CUSTOM SOLAR LLC D.l7.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLASNMELD, W (732)902-6224 MOMENMMSOLAR.COM ��. p.. EN N PE8 53 I)F STATE OF• off (olaoao C. YL,7 W_13 572E MAIOR BLVD. SLIDE 307 OR DO F 32819 CUSTOMER IN FORMATION JOHN POLI - MS42500 405 SOUTHEAST GASPARILLA AVENUE PORT ST. LUCIE, FL M983 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 14 KW 40 MODULES: LG LG 350N1C-VS 40 INVERTERS: ENPHASE IQ7PLUS-72-2-US INITIAL DATE: 1/10/2020 DESIGNER:AKH REV: DATE: DESIGNER: REV: DATE: IDESIGNER: COVER PAGE PV-1 78 CLAMPING MAX SPACING IN ZONE 1 48" O.0 AND IN ZONE 2 AND ZONE 3 24" O.0 SITE PLAN SCALE: 1/16" = 1'-O" NOTE: 1. ROOF COVERING MATERIAL IS COMPOSED OF ASPHALT SHINGLES 2. EXACT ATTACHMENT LOCATION AND QUANTITY OF ATTACHMENTS ARE BASED ON EXISTING RAFTER LOCATIONS OBTAINED FROM FIELD MEASUREMENTS.. THE LOCATION AND QUANTITY OF ATTACHMENTS MAY VARY BASED ON RAFTER LAYOUT START POINT, SPACING VARIATIONS AND ROOFING TYPE. VERIFY IN THE FIELD ALL RAFTER LOCATIONS AND ADJUST LAYOUT AS REQUIRED. A TILE ROOF WILL PRODUCE A STAGERED ATTACHMENT LAYOUT BECAUSE OF EXISTING STAGERED TILE JOINT LOCATIONS 3. EXISTING RESIDENCE EQUIPPED WITH SMOKE/CO DETECTOR IN AND OUTSIDE OF ALL SLEEPING ROOMS HARDWIRED AND INTERCONNECTED AS PER FEDERAL LAW ROOF PANEL COUNT 1. R1 31 15P R2 6 150 R3 3 150 w U Z a � N (Dz OfILI w 0 Q Q w 2" Z O SYMBOL LEGEND MAIN SERVICE PANEL CHIMNEY SP SUB -PANEL OM UTILITY METER MDLsc SOLAR AC DISCONNECT UDC UTILITY DISCONNECT aLOAD CENTER ER NEMA 3R BOX W/ ENVOY-S COMBINER BOX OI MODULE S® Elm Mr M SATELLITE DISH SOLAR0 momentum FRO CUSTOM SOLAR LLC D.B.A MOMENTUM SO AR 3096 HAMTLTON BLVD, SOUTH PLAINFlELD, N1 (732)902-6224 MOMENNMSOLAR.COM ENGINEERING ``` 11111 illl i ii i IN PIES 3 _ 1 STATE OF ®�� '•.�LORIVip•''• oiholaoa° SOLAR CONTRACTOR LICENSE NUMBER: L CS7D36 MOMENTUM SOM S728 MAJOR BLVD. SURE 307 ORLANDO FL 32819 CUSTOMER INFORMATION JOHN POLI - MS42500 405 SOUTHEAST GASPARILLA AVENUE PORT ST. LUCIE, FL 34983 (772)834-9428 SYSTEM SIZE (DC): 14 KW 40 MODULES: LG LG 350NIC-VS 40 INVERTERS: ENPHASE IQ7PLUS-72-2-US [NIT AL ® SETBACKSF PER 6TH ED EDITION 2017 FFPC REV: MIN 3'x3' GROUND ACCESS RE POINT � I PITCH DIRECTION WIND PRESSURE ZONE LINES. REFER TO PV-2.2 FOR AODTRONAL INFO DATE: 2/10/2020 DESIGNER: AKH DATE: DESIGNER: DATE: DESIGNER: M10 I ul"L1I PV-2 35OW TheLGNeONB I is LGJs bestselling solormodule, andi5oneofthemoA powerful andversatile modules on the market today. Featuring LG'S Cello Technology, the LGNeONO2mareasespoweroutpmt Newupdatestedude an enendedperfonnonce wmrpntyfram 86%to 90.03%to give cdstomenrs higherperfarmance andreliobility. Wn�HYM1Y T�IM/F wspRkBTv Features EnhancedPesfarmanre WorMray EahMardFrodurt Wamnly LG WON- 2 has an enhanced LG has extendedthe wananlyof the perfarmcnre womanly. After 25 NeONe2to25yearsfndudinglaborr, yean, LG NeONw 2 is gumanteedat which top levelf, the Industry. Ieast90.08%oJinitiofpeQamanre. Beaerierfolmal¢ on a SUanyDay LGNeONO2no wperformsbetteron ! I sunny days, thanks to its improved temperaturecoefficient. Roofilesthaks LG NeONe 2 has been designed with �J aesthetics in mind using thinner wires that opDearollblack ate distance. The LG NeONB2 on fncrease the aestheticvolue of yaurh ome with a more modern design. When you go solar, ask for the brand you can trust: LG Solar AboutLGElectrames LG Solar ..n...o�m>n..nuarow..Jaww,rs.®�m�n..,mKmem.Lmn.•..no••-•wn.wm<m mmnmmnna�.. wp„tlmn,w.JJawmx..s•wJan. ..mbew;,u..�•w wrc.ar¢,w,aY xawi arau2lwxasr::e.=...,imen.. .wfNCwIDL. LY9anItW B..aa,.am...,[m•�m a.nmYu[umm[annm.•dvnew.n a,Q' ILa]2MIC.N.IM11 6TIIp 193PY I LG N LG350NIC-VS Grnnmilmm bawbvru,aexnlbywr,l MPury,aluewNpye bOtle[ti la trmbglpvebe mph R, pl MnWgBUM1m I]L BbNMObwbm M1,W ip 1EBfmm, 1a tom way. all.. 31x BB am,rwmbg remamoenwxxteawny munMlrq..l wore nmYlamnYa YnKIq.JNn�nYm Ya.poe B.a (wuepbnpapn) Il rx nTlBromOb]n 6wJ(wmq 1COPnm•14 m.nlamPw.Yn Brc.iMc CentiftevitfonsandWarnanly /F[6aISjFlyal0le IEC W)M 22N1a Lma,-., 609W1aol4 aoswel .SU=1 b aen&Ig Tm I•"CBIrNW.0 1W �ammmb[ulmba Tfm IEL Q})lFAll re.usy mucNtna wm wwwwmm wm�n ar,m, bb W414 dIpnlWnmry W:aewprm[ry •u,raySJn,vPM1c-Sw•p+,m. C1JMnmaa•M1Yw3Mwv.NLSI Temperature a mmean Wo QYnr ca Val •Jbs• fp'a cJ6 Ibe iW`Q axr m pap im mar y.�.nmwo.�e•Jr..re..n._aom.mxwln....-.,.lvs w.Mv JM, ED.mmaMlD EAetrlml Prap,W. (NMOI) rxmrr I... s ew,Enwbnf•Pnol Iwx xm BmlVwRv➢L wmJpl M am WIC../col MI 2.9; mmamwebwlvnH M 9sW amOMwmnmtwm MI uJ IG F4fneyy NC ® �r,�G bv.Bvl�,mi.wm �Jam MLD�o.BwYe Ektlrtmi NLFr9des (ITC) YaBN laFSgy4q Yatlmvnbwv (Mm/ Im ,ID Iarxmrq. 0.. T.CPmsfaw[Ka�BfacrnlmlwA! ofmJ•mglP'C•uii Wrnb•v tJ. 0 tin Corldmonr OymeYO [Pmynm.f IV -tl -'DO aMx.msyMm vema M ImA'40 aem,mmrmreYmmp pl m YWaMTMImr(rpaa !%NTII 1B�/31) iae.•trmrmxmrrP..n rbrom ..ava -muwmi[mWe(eYsxa>miC64LS LJfILmW f.Wspn4fmb)•ry immn511 umdon ww,gtlmmnr,rbvJe MotCon w) :z xw.Y.gaJAW,1..¢wxomvmm as Gso rrtletlw Bn•QtmeuJn,a•WM trim) ttSa•1JM•ISiJ rst•mgBmGrOJWay, - pDI W Ofineruvn hnMhhl uxmxra rzaomD nvlpmbtam ® momentum SOLAR FRO CUSTOM SOLAR LUC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVDI SOUTH PLAINFIELD, W (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING `„Jf IwY/L// `% sy / GEN i PIES 53 _ STATE OF SIF o� 10 C7o SOLAR CONTRACTOR LICENSE NUMBER: N 036 MOMENTUM Sam 5728 MAJOR BLVD. SUITE 307 ORLANDO FL 32819 JOHN POLI - MS42500 405 SOUTHEAST GASPARILLA AVENUE PORT ST. LUCIE, FL 34983 ■al' 11111auYii:Iit$]C7ur_`if-01-`■ 40 MODULES: LG LG 3S0N1C-VS 40 INVERTERS: ENPHASE IQ7PLUS-72-2-US PROJECT INFORMATION INITIAL DATE: 1/10/2020 DESIGNER: AKN REV: DATE: DESIGNER: REV: DATE: DESIGNER: PANEL SPECIFICATION PV-3 :Lifes Good: Oct 18, 2019 To: Momentum Solar RE: Approval letter to use the 2 Rail Mounting Dear Momentum Solar, LG Electronics U.S.A., Inc. 1000 Sylvan Avenue Englewood Cliffs, NJ 07632 201.816.2000 This letter hereby states that LG supports and provides warranty for the referenced LG modules which have been mounted by the 2 Rail Mounting system refer to the installation manual Fig.2 for the test load of 6000 Pa downforce and 5400 Pa uplift under the test conditions based on IEC 61215:2005. icau _ 6000 Pa 5400 Pa on IEC 61215-2:2016, the test may be The following LG Solar modules are approved for warranty: ■0G1MWNW 5—comber E_LGfModellNum er LGxxxN1C-V5 I LGxxxN1K-V5 LGxxx 1C-VS I LGxxx 1K-V5 t00= tooBlm Our warranty provides all the terms and conditions underlying our obligations and the warranty. Although this Letter serves as an authorization to employ the 2 Rail Mounting System, the original warranty terms for the modules would be rescinded in the event of: - Misuse, abuse, neglect, or accident such as micro crack to the cells or glass damages; - Alteration, improper installation or application; - Non -observation of LG Electronics' installation and maintenance instructions; - Repair or modifications by someone other than an approved an approved technician of LG; - Power failure surges, lightening, fire or other event outside LG Electronics' control; - Defect or Power drop due to the incline load; If you have any questions or concerns in regards to this letter of authorization, please feel free to call your LG Electronics Sales Manager. LG Electronics U.S.A. Inc. North America Solar Business Team 1000 Sylvan Avenue Englewood Cliffs, NJ 07632 e PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, N3 (732)902.6224 MOMENTUMSOIAR.COM ENGIN X1111 )rt/ / `♦�® .• ENS � 5 3 p PE8 — � X' ••'• r.P i i °� S-rATF OF • AU ` `•� MOMENTUM SOLAR V28 MAJOR BLVD. SUITE 307 0MANOO R 328L9 CUSTOMER INFORMATION JOHN POLL - MS42500 405 SOUTHEAST GASPARILLA AVENUE PORT ST. LUCIE, FL 34983 PV SYSTEM INFORMATION 40 MODULES: LG LG 3S0N1C-VS 40 INVERTERS: ENPHASE IQ7PLUS-72-2-US l PROJECT INFORMATION I INITIAL (DATE: 1/10/2020 (DESIGNER: ARH REV: DATE: DESIGNER: REV: I DATE: I DESIGNER: PANEL LOAD TESTING RESULTS PV-3.1 I:,d I',htvl Enphase Microinverters .ccxtx, AM +Ir-A', Enphase IQ7and IQ7+ Microinverters 9 To learn more about Enphase offerings, visit enphose.com The high-powered smart grid -ready Enphase 10 7 Micro" and Enphase 10 7e MleW dramatically simplify the installation process while ach'eving the highest system effic'ency. Part of the Enphase IQ System, the IQ 7 and IQ 7t Mcroinverters integrate with the Enphase IQ Envoy', Enphase IQ Battery', and the Enphase Enlighten" monitoring and analysis software. IQ Series Mlcrotrwerters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry-0ea6ng warranty of up to 25 years. Easy to Install Lightweight and simple Easter installationwllh improrned• lighter twowdre cabling Bud41n mold shutdown Compliant (NEC 2014 E 2017) Productive and Reliable Optimized far high powered 60-cell and 72-ce116 modules More than a million hours of les"g Class11 douoleansulaled enclosure ULIISIed Smart Grid Ready Complies with advanced grid suPpor%voliage and frequency ddMhrough requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Mects CA Rule 21 (UL 1741•SA) • the 10 7- V tee isn<uledlosnpvar 17 aILv ldat v ENPHASE. IQ 7 and IQ 7+ Microinverters Commanry rNeOmowM WmrgT Z331'a-3pO TY♦ Module cerpWUbltity 60-cellpilmodu<lonty IAaxkoum Input OQvotta6e 48V Peak Pawbr tracking v4ea0o 27V-37V Operating i4ag0 16 V-48 V MINMaa !tart vahace 22V/48V Max DC:hort&CVA Wicnl(mcdule Ise) 15A Overvonage eetSt DC pat 11 DC port backfeed oureshl O A Pv Wray configuration I x I Vgiounded Wray,I Peak output paw% 250 VA Maximum com inuow aatput pang 240 VA NOrnktal(L-L) vollxgetrangea 240V/ 203V/ 211-26411 183-MV Ma xbnu, ccmnumn put put current la A(240 V) IISA(208V) Nominal frequency 60 H: EatWad fregFimcyrarlge 47.68 Ht AC Shot circuit fain Current Oros 3 Cycles SAArms M mimun waits per 20 A(UL) branch ceculs 16(240 VAC) 13(208 VAC) Oretvoeago class AC pail III AC pat bacUeed cement OA Power raw& aettlnp 10 Corxwclortype (107.60.2-USS 107PLUS-72.2415) Ctnnector type QQ7b0."S 61Q7nUS•7b84JS) Dlmmafona(WxH.D) Weight C"Im APPPved for wet location, pamon Cevia 60-cell and 72-cell PV moduk! 60 V 27 V•45V 16v•60V 22VI60V 15A 0A 24Ov/ 271.264 V 1,21 A (240 V) 60 Hit 47.68 H2 5.8Arrm 73(NO VAC) tli oA 1,0 203 V / 183 229 V 139 A (208 V) 11 (208 VAC) 4%to 100%(Condensrp) MC4(ar ARplieriol H4 UTx i:th additional O-DCC•5 adspirl ) Friends W2 (MC4 lntermaleab'e). AdaP:ws formedulos with MC. or UTx Corwectors' -PV210 MC4 Cider ECA-S2g522 - PV210 UI X order ECA-S20-S2S 212 mm x 175 mm x 30.2 mm (wbhout bracket) 103 kp(233lot) NeMal emrectbn • ero lama Vas PD3 Enclosure Class II double-i aula'td• Corrosion resistant polymeric encloove Em+Vormental category/ UV expa3we ratbl0 NEMATime6/Outdoor FEATURES COmanUNpaDprl Power LIne CoMmurilcat too (PLC) - Mon'aorlrg Fnlghten Manager am MyEnlgbten mcnitoril0 Cohan!. Both optierts seltuira ktstaeation of an Erphase IQ Envey- Ol:pomecl8pmeans TheACarld DC Comment havebean evaluated and approved b/ UL far we as the Wd-break disconnect required by NEC 690. Compilance CA Rule 21 (UL 1741•SA) UL 62109.1. UL 1741/I EEE IS 47. FCC Part 15 Cbaa B. ICES-M03 Char 8- CAWCSA•C22 2 NO, 1071.01 TKI product is UL Listed as PV Rapid Shut Down ECulpment and contains with NEC-2014 and 1 Nomrotrra_C1AC tarnna Netocdbiy nvir4,I rcqu tied afL r_or,.•ra ali'tptgOlilLlfAilLSPCDIIhlll 7. tier. wna9<rang[ lat i alli, : acdntTtMrlantui:lIe[u'rtdbnlatut 1:1} t. I:nu rvrray Nr(tno Wtalrrtti,tnrnH I>delrc M nmwer tl mvwmn ma Cis nentn'n rwi.vm To learn more about Enphase offerings, visit enphase.con v ENPHASE. p:g•aL.y�+�.aC..aerA„'l-•�e•,r.eax-:.a:v,:tt,ntm.�:aae c.e>ox:ral.m,x rnv Wr. �'e- - PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, W (732)902-6224 MOMENTUMSOLAR-COM PROFESSIONAL ENGINEERING 1111/11// INNo °P 53 �00 ••. STATE OF 01 )1O /6,07:0a0 SOLAR CONTRACTOR CN14MON CHRISTENSEN CERTIFIED SoIAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMSTI M SOLAR 5728hWORBLVD. SUITE307 ORLANDO EL 32819 CUSTOMER INFORMATION JOHN POLI - MS42500 405 SOUTHEAST GASPARILLA AVENUE PORT ST. LUCIE, FL 34983 I PV SYSTEM INFORMATION I SYSTEM SIZE (DC): 14 KW 40 MODULES: LG LG 350N1C-VS 40 INVERTERS: ENPHASE IQ7PLUS-72-2-US PROJECT INFORMATION INITIAL DATE: 1/10/2020 DESIGNER: A¢H REV: DATE: DESIGNER: REV: DATE: DESIGNER: INVERTER SPECIFICATION PV-3.2 1: n 1'Il,,•I Enphase Netvrorking Enphase IQ Combiner+ (X-IQ-AM1-240-2) U� USTED To learn more about Enphase offerings, visit enphase.Com The Enphase 10 Combiner+'• with Enphase IQ Envoy' consolidates interconnection equipment into a single enc osure and stream Ines PV and storage Installations by providing a cons-stent, pre -wired solution `or resdent;al applicaEons. It offers up to -*our 2•po:e input circuas and Eaton BR sexes busbar assembly. Enphase IQ Combiner+ MODEL NUMBER IQCembbxre k[Q-AMIQ40.2 IQ Canbinor. Wah Enphase IQ Emq` fa Integrated revenue grade PV Production metering (ANSI C12.20 a/• 0.5%) and optional* Conatinotlanmanitodng(#/-2.5%). ACCESSORIES (older separately) EnWoseMobileComeel- CELLIAODEM-03(1G/12-yoardataotir) Plug and play tMulslprade cellular Ted" withdnta plan la eystans up 1o60 CELLIAODEM41 (30 1 S•yeudata darn mictolm'aters.(Available in NeUS,Canada,Mexico,Puerta Rico, and NeLISVOCA Islands, CELLMOOEM-MI(40 LTECAT-MI/57eardatlplan) Wherethae badertualetellula ea NCe lnme Installation Area.) Consumption Monitonng CT CT•200-SPLIT Stiff care Current uansramaa enable whole eAme eonacnplio n Taping. (H-2 5%) Chroal Breakers 132 15A-2-2a0 Breaker. 2 pole, 15A Eaton BR21 S BRK•20A•2.240 Greaker, 2 Pob, 20A, Eaton DR220 ELECTRICAL SPECIFICATIONS Ral'ug Contnuausdtay system voltage 240 VAC, 60 HZ Eaton OR Carin bhcbar rating 125A Mal Continuous culrml rating (output to gild) 65A MM. fuse/caNt ratig(anpul) 90A Branch cuCuits(solar and/or atorage) Up to feu 2•peft Eaton BR attics Disuibured Gmaation(DG) breakers orWncl included) Max, Continuous Current rating (input Gem PV) 64A Mail total branch chr dl breaker rallog(mput) 60 A(any rnmDk+ation) Productiontreterig Cr 200 A sold eerepre{malled and Ered tolOEnwy Smart MECHANICAL DATA • Incl0Ces 10 Envoy for communleapon Oknemlons(%%',H.D) 49.3 A 46.5 x 16.0 an(far x 18.3•x 6.3•) and control Weight 7,5 kg (10 5 Car) • Fleahb:e COW01king suppals%Vi•Fk Ambkm lernpmlueratge •40-C to e46t C(-AD-to 1IS- F) Ethernet, or cellular CoanO Natural Correction, plus heal steekt • Provides ploducton metering and option at Enrbsao mriammulmNrg Outdoor, NRTLccrtibed, NEMA IWO 3R Pot/earbonate comiruGtion conSOmphon malAoring waeslaes 20A105OA0reakpn uls: 14te4AWGe D oDger Conductors • supportsinslaltal,on 01 the • 60 AaeakM branch trout 3101/0 AY70 eCppa eonductae Enphase Q Aggregator` • Mah Aug combined output, 10 to VO AViG cooper con0uctors • Ntubel and gfour,D late 1/0 Copper Conductors Always follow Iaaleode icgdriments fa conductor shiny. Simple Altitude To 2NOrnetpa (6,560 fee0 • Eaton OR series p3niELNrd intend INTERNET CONNECTION OPTIONS • Up W four 2-pole branch circuits for 240 VAC Inttgrated IVEFl 602.111ay0yn auglin breakers (not included) Ethernet 9023. C315E (a Cat 6) UTP Ethernet cable • not b¢kided • EGA total PV a storage branch druids Cemlu - Optional,CELLIAODEM-01(3C)a CELLMODEM-03 (40) (not lnelided) COMPLIANCE Reliable CCmDkance cornbbler UL 1741 CANICSAC222 No. 107.1 • Durable NRTLCendled NEMA type 47 CFk PMt 1S,Claaa B, ICES COS SIZE encfesure Aodualonmaph9: ANSI CIZ20 SCaaary class OS (PV Production) • FWeVcarwannnty CmPkance. lit ErwW UL 916 CANICSA C22 2 No 61010.1 • ULlisled ' ConPsrnptim montairg u reeuuad fa Erphese Stange S�'rttms To learn more about Enphase offerings, visit enphase.otim *%M ENPHASE. �o'm ,<E..gee1, •,•r�.NA_.,x ,,oar�t, :,a>,.�,,.a•n •L,<-.:n.h,.e .r• � ENPHASE. 11010MR, glmva PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NI (732)902-6224 MOMENTUMSOLAR.COM NG ♦\`� 1111 III / /! \♦®• • EN = N PIE8 53 ,0 STATE: OF E� Ats 0) Ion SOLAR CONTRACTOR CERnF1ED SOLAR WItntALTOR LICENSE NUMBER: MM7036 MOMENTUM SaAR 5728 MNOR BLVD. SUITE 307 ORIANdO FL 32819 I CUSTOMER INFORMATION JOHN POLI - MS42500 405 SOUTHEAST GASPARILLA AVENUE PORT ST. LUCIE, FL 34983 SYSTEM SIZE (DC): 14 KW 40 MODULES: LG LG 350N1C-V5 40 INVERTERS: ENPHASE IQ7PLUS-72-2-US PRo] ECT INFORMATION INITIAL DATE: 1/10/2020 DESIGNER: AKH REV. (DATE- (DESIGNER: REV: DATE: DESIGNER: PV-3.3 soltection" b/ vynckier RJ-1 Residential Transition Box The Soltection RJ-1 rooftop junction box with flashing provides a safe, secure, and NEMA 4X watertight solution for the Solar installer to penetrate the roof for attic runs and make the proper wire connections. The product Is designed to be simple to install, minimize time on the roof, while additionally providing higher levels of protection for the point of penetration in the roof as well as electrical connections inside the junction box. Key Features • Designed specifically for solar Installations • Ughtwolght • Non-metallic —Will NOT rustfeorrodo • Easy to drilUmodify • Captive screws In cover• will not fallout • Minimal design, small footprint • NEMA 4x rated • All roof penetrations cover by Nema 4x enclosure C @us USTEn sultealonbyvynrkirr yrxLer rnt/Uw a syvm% :71 sttcanYYlat. Ha MTX 77029 USA .1,VA2270S77 nww.lndfllian fun Specifications Enclosure .Material: Polycarb b:endw/ W Inhibitors W Stabilized: Yet Im;act Resittarce: Yes Weight 2.731b Color. Graphite Black Dimensions Flashing Dimensions (Approx'znatek 13' x 1 B' Enclosure Dimensions (Approximate): Ir x 8' Total Product Height 3.5' Cubic InChCS1224 Cubit Inches ® momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOFIENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PWNFIELD, NI (732)902-6224 MOMENTUMSOLAR.COM ENGINEERING t11111 fill N PE8 53 f P, — II�i4`I:is"r1„ i� STATE OF74. NAI. //ll Illtl\\ I SOLAR CONTRACTOR SURE 307 CUSTOMER INFORMATION I JOHN POLI - MS42500 405 SOUTHEAST GASPARILLA AVENUE PORT ST. LUCIE, FL 34983 PV SYSTEM INFORMATION SYSTEM S1ZE (DC): 14 KW 40 MODULES: LG LG 350N1C-VS 40 INVERTERS: ENPHASE 1Q7PLUS-72-2-US PRO1EOr INFORMATION INITIAL DATE: 1/10/2020 1 DESIGNER: Arm REV: (DATE: (DESIGNER: REV: DATE: DESIGNER: JUNCTION BOX SPECIFICATION( JUNCTION BOX SPECIFICATION FOR SHINGLE ROOFS PV-3.4 PROGRESSIVE IMAT andd3d. S SS 300 Series Professional Grade Silicone Sealant BASIC USES & DESCRIPTION: SS 300 Series SMcono Scalant is a mep-gum modulus sircone sealant dessgntd for roof rg apprtatlens and various joint appl'cations. COLORS: SS 300 Series Silicone Sealant is available in 3 standard colors: white - SS 301 `,an-S8302 Light Gray- SS 303 (Custom odors may be available upon request at an additional charge) PACKAGING: SS 300 Series Silicone Sealant is available in 10.0 0. oz. cartridges. WEATHER RESTRICTIONS: SS 300 Series Silicone Sealant should not be applied when temperatures are below 2WF or above 120'F STORAGE AND SHELF LIFE: SS 300 Series Silicone Sealant has a recommended shelf life of 12 months from date of manufacture when stored in unopened container and between 50`F and EO°F Refer to product packaging for manufacture data APPLICATION: The surface must be clean, dry and free from oils and other contaminants. A thorough wint brushing, grinding, sandblasting or solvent cleaning may be regdted to expose dean, sound, virgin surface. SS 300 Series is primediass an most common. nonporous building substrates. Consult Progressive Materials, LLC for priming tecommend3Cons on other materials. In all cases, a sample mould be tested and/or test joints should be installed on the project to confirm stitability. TYPICAL CURE RATE: Cure ra:e at 77'P and 50% RH! A. Tock•free time: 30 minutes to 1 hour SILICONE ROOFING SYSTEMS Technical Product Data 0. Tnrough cure (3/8" depth); 6-12 hours CAUTIONS & RECOMMENDATIONS: SS 300 Serles in neither tested nor represented as suitable for medical or pharrmaictutieal usus- SS 300 Series is not rccemrmnded for silicone structural g!azinq, application in confined areas without proper ventilation, orjoints under constant water submersion. LIMITED WARRANTY INFORMATION PLEASE READ CAREFULLY-. The information herein is to assist customers in determining whether this product is suitable for various applications. This product is orlf intended for sale to industrial and commercial customers. Customers assume full responsibility for quality control, testing and down inairon of suitability of products for its intended applicafon or use. We warrant that our products will meet ourv,Tiren specifications. We make no other warranty of merchamoU ity of fitress for a particular purpose. Out total liability and ctdtomere excusn•o remedy for all proven claims is replacement of nonconforming product and in no event shall %v0 be liable for any other damages, including without limitation to special, incidental, punitive, orconsequenial damages. TYPICAL PROPERTIES Test Properii� Oynamie JdM M1ferrrmtrnt 19L1 VaIUQ f46 Test Procedure AS1M C.719 600 ASiM D-412 Tara@stnm ht(psa 140 ASTMDA12 Modulus, 100% Eb don(pit) 38 —AS71A DA12 Hardmptsshot*A 25 ASTIA C-661 Tack•FrN TNM(minut") 60 ASTMC-6)9 Range (7) ar�tun .50 to •2E0 P.0 AccolaratedlVeathadng, 5000 his, -- Pat$ ASTM C.793 YOc t - <50 ASTM D-3W Conuct Prcgrrss:ve Materials for more deaded specificatons on our roofing systems and to find a cer;fied contracor near YOU. C C ® @% f AFM R� rsr to as USTED MOM M Revision Date: February 18, 2014 SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING Z3- ; Ai' ® ••. STATE OF `0 FVG®61�� SOLAR CONTRACTOR GMERON CH0.161ENSEN LICENSE SOUR C VC57036 LICENSE NUMBER: CY6)036 5726 SID0 F BLVD. SURE 307 ORUNDO rt. 37819 CUSTOMER INFORMATION JOHN POLI - MS42500 405 SOUTHEAST GASPARILLA AVENUE PORT ST. LUCIE, FL 34983 PV SYSTEM INFORMATION� SYSTEM SIZE (DC): 14 KW 40 MODULES: LG LG 350N1C-V5 40 INVERTERS: ENPHASE IQ7PLUS-72-2-US PROJECT INFORMATION INITIAL DATE: 2/10/2020 1 DESIGNER: AKH RI EV: IDATE: IDESIGNER: REV: DATE: DESIGNER: SEALANT SPECIFICATION PV-3.5 momentum SOLAR DESCRIPTION: DRAWN BY: DESCRIPTION: DRAWN BY: SNAPNRACK, CONDUIT SUPPORT COMP SHINGLE M.Watkins 5flup ack SNAPNRACK, CONDUIT SUPPORT COMP SHINGLE M.Watkins (�� p,,,. snap \1�ack PR3096HAILTONBLLCD.B.A. Solar Mounting Solutions Solar Mounting Solutions PLAINTULD,NI 3096MAMILTONBLVD,SOUTHPIAINFIELD,N] (732)902-6224 REVISION: REVISION: MOMENTUMSOLAR.COM PART NUMBER(S): PART NUMBER(S): PROFESSIONAL p ASY3MNCD pM=4MM FA Xl(NR356«36�9]iA«,«w PNONE242-02106 A mfYm¢Ts PHONEi.1 «t "WO: MMrND ENGINEERING Yu"i W PCW,CmwW I•b,OfMV.IM �"�OR,n'mnev�we"am��rte.ndr>ti 242-02106 n. w.iuoi "�ovm4m wannnuv� °fmwiiu .�.ne"raoPnee.n.«"..m n va `,PAP 104- PARTS LIST ITEM QTY DESCRIPTION 1 1 SNAPNRACK, L FOOT FLASHING, 12IN X 12IN, BLACK GALV 2 1 SNAPNRACK, CONDUIT SUPPORT STANDOFF SUBASSEMBLY 3 1 SCREW, LAG, S/16IN X 1-1/2IN, HEX, SS 4 1 SNAPNRACK, L FOOT BASE, MILL MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL, ZINC PLATED STEEL, GALV STEEL DESIGN LOAD (LBS): N/A ULTIMATE LOAD (LBS): N/A TORQUE SPECIFICATION: N/A LB -FT CERTIFICATION: N/A WEIGHT (LBS): 1.11 snap(NPQ¢k OOM U.u=R90cho8xvR PATENT 1 8.539.719 6.00 12.00 ilglll] ALL DIMENSIONS IN INCHES 2 " 12.00 `�, k-P' i 3 STATOF '• E. �.�''. FLOR\OP'.•�6y���� 0,�,01aoa� �C i SOLAR CONTRACTOR CAMERON OHBUSTENSEN MnRED SOLAR CONTRACTOR LICENSE NUMBER: CVC59036 MOMENTUM SOLAR M8 WEIR BLVD. SUITE 307 ORLANDO PL 32819 CUSTOMER INFORMATION JOHN POLI - MS42500 405 SOUTHEAST GASPARILLA AVENUE PORT ST. LUCIE, FL 34983 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 14 KW 40 MODULES: LG LG 350N1C-VS 40 INVERTERS: ENPHASE IQ7PWS-72-2-US PROJECT INFORMATION INITIAL DATE: 1/10/2020 DESIGNER: AKH REV: DATE: DESIGNER: REV: DATE: DESIGNER: CONDUIT SUPPORT SPECIFICATION PV-3.6 smFr na7AumoNAnPK7tiRaoF semrowTa rmaalmart Vr wlDixxsFAOxO Remros�c•AnAaamvr ce6u• soMnaq lwawa. PoRLET.VISDNAn V Nm 416Tro1unN WAlP3ACCbDIf IXEV.WQ6 M.'mAE�lilf'�' 9RaPrmanc Rox 4nAOPmlr FRo9ucTs RFMro5 my Ql9'ttiNrttTA¢' Mod1F.T19. sw+m.�K umvRAA iw CETAD3pI VAPIg15411P1Vfiq Am3sam Armolnw6ra3D PACOIKTS 6VMNR/D(umAx+n 6omrasumRA¢uwvlKsuDm ALL aHmumswMD1A¢ADASANE Do DETAIL A: DETAIL B: DETAIL C: aAaauxr¢unnox emMDwus SNAPNRACK, ADJUSTABLE END CLAMP SNAPNRACK, MID CLAMP SNAPNRACK, UNIVERSAL END CLAMP anuaEs wr r@ aAxm aN sxwr w IDRG snxa rm amue MuarArnwel RD1uvu30xi5 wlsw.r azMDlmmm uRAxAvnw AGOSS TXC 91aR f/ n@ NO[P n rosvaNmna[vuTUG wlawMWDw BNWWAR6TORU S�IGn9Ns ti,.� 1 DA H wR DY vmm sunwoc LLTLL4 SDI¢ uu9 ISN90N: IWAnaV®o_� 9lWMOL 4.YMLb[ IIXM MD. NID 911¢ ¢TA05 --_--_ PEMnrownamA¢DUTAueTwv RNalN.wa S/�6• Wt MMPVNNTRWFSM1TgIGl1d6 • PIW'PARSpOA FRAFft, TP: a1WEeITwo RDDPAnAovmns ¢umvasnlemaArv. NorAwaw®-unavmiwas/ w^0E"FAS �xlartAmKrsr¢Aro xraAm NDpRE usEvraux49sua:wrtxraLRm RA¢R LLIMM4 APMI4fnl SNAPNRACK, UR40 SPLICE INSAU.ED St mT DiW sunmbcmrmvcam.mea tw¢rAwYm Rm Nxm9a AaU1SS PAAs ry3e•Duaexl urrwxt ear,ss IA• 9w.mivx.IwusnuT,mmw SNAPNRACK, UR40 SPLICE SNAPNRAM ULTRA PAIL MOUNTING HARDWARE SPLICE ALIGNMENT LIMITS I� Sur SNAPNRACK, UR-40 RAIL �Ju uU;�II VYl4hSW '�^- •�•••®-••-'� DPAFIFR: N.PRENIRIN691 V�sNRDGAOJM r ULTPA PA14 sf51FM OVERVIEW, TYPICAL A• ?�Y,vW�iU ORMHL•MAREMMNfR SNR-0C-0N.TO v„wnar:1ATW1R'1140DMi0nEM DETAR URiO RAR soM�„RDnW9SClweru � s - ,,ggp.�mar:.BwlER9DN wro S/)/2019 ] sow Moun6n95a1u6o,u -_.�.- - w,E NlO SRICE OESORD'110N. DRAWN BY: ��'�' � ev ��m' Sn/2039 CJI f�U�Il Vll l�_iIISYY SNNTN/A(4TM xALLD!®f91.31 IDOL WIIII M1r�ur' Rwm011 -- SNAPNRACK,ULTRA RAIL COMP KIT m atP3ns NurRroA; � � �Yr-R umor cwoswx02 RaoFD+4 rrv. B Solar MD ting SOlutlom REVISION: RHfA 10 RWNVI4 fNGwFBYxGOWR5 W4 aC6 DFAPID.TW. ____ PARE NUMBENI6Y O ..°m+a.rn.i�a SIGH MARM'BDf MIKBIW nDSDMWCY' 4MfT1UD WVDuss _--- o w�euuDsaFw.T% mmmalm�q SEE BELOW � � � a y16•dASi1D9➢IBIAIAG s¢BvrusrO4lmAMu LLsuwo.lac WmDRaFrERTrR. ® oFr WIDsnLLTUPA1RRn®1 RSTArosuxaaa9arAuxnm Mwa m snewwxcawvua:iwa¢seF$:unus O PAaux 9EMwmmox Dmmvceorra .� L4Lbf �� Rw IEvOa+c urAAs, RLTmrosuBmac ¢TALL DRAW IMD 91RMtRR LL1M Gn. OJIbQIIM nfTM.IFV8II1Gf%IEgd1 N' 41M6IIItVL111l1WiNAw9ET 1 f4AL5Ultm181,34GN0 W'M£DAOYIEI rrmL B®aumRr WIDMOCONDH4 VMAtDUDRS DN BA9mRDrosxmDvum PENETRATION DETAIL 2 3 ® O INSTALLED SECTION VIEW momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM ENGIN ♦♦ 'GEM F '•.,� 53 o P� III .1,rdn I` Sgg TATs OF 10 IONAU ' 01l iIOr\k ra SOLAR CONTRACTOR MOMENTUM SOLAR 5726 MAIOR BLVD. SUNS 307 ORLANDO Fl- 32819 JOHN POLI - MS42500 405 SOUTHEAST GASPARILLA AVENUE PORT ST. LUCIE, FL 34983 PV SYSTEM INFORMATION SYSTEM SIZE (DC):14 KW 40 MODULES: LG LG 350NiC-V5 40 INVERTERS: ENPHASE IQ7PLUS-72-2-US .TNUMBER PARTS LIST DESCRIPTION I2J0 N.u-�IIVGC�C�W I _�'•�:IANmimm: B.RlDL50N wn' W<M2019 µ•n,••nu.mu I�w�v�,uc� LFOl1ITORPFTFR4�u I� ORNTER: MARI9AFANCAI SNR4)G00139 12-92266 SNAPNRACK, UMBRELLA IAG, TYPE 3,41N, SS soweeonun921E -� - PROJECT INFORMATION N9 242-01220 NAPNRA ULTRA FOOT FOR U FUSHING, SILVER BUCK 175 232.01376 NAPNRACK, COMP FLASHING, 9IN K 12IN SILWR I BUCK ALUM ATTACHMENT DETAIL FOR SHINGLE ROOF INITIAL DATE: 1/10/2020 DESIGNER: AKH 6000 SERIES ALUMINUM, STAINLESS STEEL, RUBBER 405 UP, 788 DOWN, 236 SIDE REV: DATE: DESIGNER: 2006 UP, 4000 DOWN, 1070 SIDE 12 U-R REV: DATE: DESIGNER: UL 2703, MLE 059313; WIND-ORIWN RAIN TEST FROM UL SUWI nQ 0.8 0 ATTACHMENT DETAIL PV-3.7 CERTIFICATION OF WIND LOAD 17:SURE CALCULATION THIS IS A 2-R,__',IDESIGN DESIGN LOAD CRITERIA. AS PER ASCE 7-10 (2.4.1) FOR THIS PARTICULAR CASE, THE "DOWNFORCE" CASE 2 AND UPLIFT HAVE BEEN TAKEN INTO CONSIDERATION. P (PSF) =1XD + 1X PNET (DOWNFORCE) P (PSF) = 0.6XD + 1X PNET (UPLIFT) (P = TOTAL DESIGN LOAD) (PNET = WIND LOAD) (D = DEAD LOAD) PNET HAVE BEEN CALCULATED FOLLOWING THE ALLOWABLE STRESS DESIGN METHOD. THE MAXIMUM ABSOLUTE VALUE OF THE 2 CASES IS THE UPLIFT LOAD. THIS 2-RAIL DESIGN IS WELL UNDER THE CAPACITY OF THE INDIVIDUAL ATTACHMENT CAPACITIES FOR THE DESIGN. THE PHOTOVOLTAIC MODULES USED IN CONJUNCTION WITH SNAPNRACK2-RAIL ATTACHMENT SYSTEM ADDED HAVE A DESIGN CAPACITY OF -4,000 PA., 84 PSF. THIS DESIGN IS WITHIN THE LOADING CAPACITIES OF THE PHOTOVOLTAIC MODULE 2-RAIL DESIGN TESTING CAPACITIES THAT HAVE BEEN PERFORMED BY INDEPENDENT TESTING BY THE PANEL MANUFACTURERS ENGINEERS. SEE ATTACHED MANUFACTURERS TEST DATA. WIND PRESSURE ZONE CALCULATION (ASCE 7-10 FIGURE 30.4-2A, 213) HORIZONTAL DIMENSION A 84.70999908447261 X 10% = 8.47099990844727' HORIZONTAL DIMENSION B 78.1106006103515' X 10% = 7.81100006103516' BUILDING HEIGHT 15' X 40%= 6' PRESSURE ZONE WIDTH 6' 0 " 10 % OF LEAST HORIZONTAL DIMENSION OR 40% OF THE BUILDING HEIGHT WHICHEVER IS SMALLER BUT NOT LESS THAN EITHER 4% OF THE LEAST HORIZONTAL DIMENSION OR 3'-0" m I ��ai_i � r � �•�_vre� ■ r_t� : I L� ra � `�` r:� � ���y cr�.�i ZONES 1&2 1&2 1&2 1&2 WIND LOAD CALCU ' ,DNS (A4, VELOCITY PRESSURE Qz = 0.00256 Kz* EXPOSURE B Kz (VELOCITY PRESSURE EXPOSURE) 0.57 Kzt (TOPOGRAPHIC FACTOR) 1 Kd (WIND DIRECTIONALITY) 0.85 V (WIND SPEED) 160 MEAN HEIGHT 15.00 VELOCITY PRESSURE Qz 32.02 EXTERNAL PRESSURE COEFFIENT (GCp) (ASCE 7-10 FIGURE 30.4-28) ZONE 0 To 7 TILT 7 To 27 TILT 27 to 45 TILT DOWNWARD 1 -0.9 -0.8 -0.8 0.3 2 -1.1 -1.2 -1 0.3 3 -1.1 -2 -1 0.3 WIND PRESSURE o = Gz * IGCo - SOLAR MODULE TOTAL WIND PI ZONE 0to7TILT 1 N/A 2 N/A 3 N/A 3LAR PANEL WI ZONE RATIO 4:1 3:2 2:3 1:4 -RAIL RACKING COMPONENT 5/16" DIA. 4" LONG LAG W/ 3.00" EMBEDMENT INTO 2X ROOF RAFTER (SEE SHEET PV-2 FOR SPACING) INVERTERS W = 266LB/IN EMBEDMENT (NDS11.3.1 TABLE 12.2A) FOR DF. LARCH, S.Y.P., AND S.P.F. SPECIES CD = 1.6 (TABLE 2.3.2 2015 NDS) RAILS (2-RAIL) @ 5.8LB/LF. CT = 1.0 (TABLE 10.3.4 2015 NDS) W = 266LB/IN X 3.00" X 1.6 X 1.0 = 1,276.8LBS = ULTIMATE ATTACHMENT/FLASHING -THREAD MUST BE EMBEDDED IN THE SIDE GRAIN OF A TRUSSES OR OTHER STRUCTURAL MEMBER INTEGRAL WITH THE BUILDING STRUCTURE. ARRAYTOTAL -LAG BOLTS MUST BE LOCATED IN THE MIDDLE THIRD OF THE STRUCTURAL MEMBER. TOTAL LOAD/ATTACHMENT -THESE VALUES ARE NOT VALID FOR WET SERVICE. 2-RAIL RACKING SYSTEM -INSTALL LAG BOLTS WITH HEAD AND WASHER FLUSH TO SURFACE (NO GAP). TORQUE AS PER 7 To 27 TILT 27 to 45 TILT -19.85 N/A -32.66 N/A -58.27 N/A 0To7TILT N/A WEIGHT/UNIT 37.7 4.0 1.8LB/LF GRAVITY LOAD 0.98 722SF 7 To 27 TILT -22.4106 -24.9718 -27.533 -30.0942 MANUFACTURERS SPECIFICATIONS. DO NOT OVER -TORQUE. MAX WIND PRESSURE ZONE 2 -WITHDRAWAL DESIGN VALUES FOR LAG SCREW CONNECTIONS SHALL BE MULTIPLIED BY TOTAL WIND PRESSURE APPLICABLE ADJUSTMENT FACTORS IF NECESSARY. SEE TABLE 10.3.1 IN THE AMERICAN WOOD COUNCIL NDS FOR WOOD CONSTRUCTION. TOTAL ATTACHMENTS TOTAL UPLIFT WIND LOAD ON ATTACHMENT TOTAL UPLIFT FORCE/ATTACHMENT POINT 166.3LB IS BELOW THE ALLOWABLE 1,276.8 X .33 = 421.34LB 15.37 15.37 15.37 27 to 45 TILT 1796 13.71 ASCE 7-10 N/A SOLARmomentum PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM `�� GEN @ •� �� .PE 53 •. i�®.'•. STATE OF O l �(O�o'0 N/A SOLAR CI N/A D ERON 0IRISTENSEN /1 CERTIFIED SOLAR wNfRACfO 110ENSE NUMBER: CVC57036 MOMENTUM SOLAR MS MAJOR 6LVD. SURE 307 DRIANDO F 32819 CUSTOMER' -32.66 -23577.20 131 -179.98 -166.3LB JOHN POLI - MS42500 405 SOUTHEAST GASPARILLA AVENUE PORT ST. LUCIE, FL 34983 PV 40 MODULES: LG LG 350NlC-V5 40 INVERTERS: ENPHASE 1Q7PLUS-72-2-US PROIECf INFORMATION INITIAL DATE: 1/10/2020 DESIGNER: AKH REV: DATE: DESIGNER: REV: DATE: DESIGNER: STRUCTURAL CALCULATION PV-3.8 -C ELECTR SERVICE ELEVATION 0. ••EXISTING •' • • • ... •• i • I •• • O :.i 'r • �,. ; . EMPHASE 7•. : +• T :. !• i •' .. • METER .• .. . •.• •. COMBINER .. SOLAR • e B X. O •' . •�, •• �:• BOX AC .• B DISCONNECT', : •• • ' i'• }.. MSP LOCATED INSIDE OFSTRUCTURE #2/0 AWG SERVICE CONDUCTOR FROM OVERHEAD FOR 200AMP SERVICE 40 LG LG 350N1C-VS 35OW MODULES PAIRED WITH 40 ENPHASE IQ7PLUS-72-2-US MICRO -INVERTERS BRANCH CIRCUIT A 10 MICRO -INVERTERS BRANCH CIRCUIT B 10 MICRO -INVERTERS ••• BRANCH CIRCUIT C 10 MICRO -INVERTERS BRANCH CIRCUIT D 10 MICRO -INVERTERS TERMINATION CAP INSTALLED ON END OF CABLE ••• MINUMUM BEND RADIUS 4" HOT LINE PV SYSTEM CURRENT 60.5 A ENPHASE80A COMBINER BOX SOLAR CIRCUIT DISCONNECTING MEANS EATON SODA FUSIBLE SOLAR AC DISCONNECT INTERCO_-, 1CTION DETAIL ENCLOSURE DIMENSIONS LENGTH:. 12" WIDTH: 12" DEPTH: 8" #210 AWG SERVICE CONDUCTOR FROM UTILITY METER FOR 200AMP SERVICE FSEC CERTIFICATION STATEMENT: PER FL, STATUE 377.705 (REVISED 7/1/2017), I, MINA A. MAKAR PE# 86753 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBC 2017 EXISTING SQUARE D 200A MAIN SERVICE PANEL 240 V MAIN BREAKER: 200A LINE SIDE HOT TAP IIIGRID ® momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NI (732)902-6224 MOMENTUMSOLA0..COM PROFESSIONAL ENGINEERING III( III GE N PE 5 i Ate••.• STATE OF • ��� ORION /1/ ®11Al 1I�'I\\� OlI1O/o' X SOLAR INSTALLED ON r ROOF 10A BREAKER (ENVOY) Y T SENS POWER ITAP BOX �- -J RAIL SYSTEMumbfflBIB I JUNCTION 2A 20A BREAKER (A) 70A FUSES IMONITOR GROUND= MEETER 1AT01D BOX 2B 20ABREAKER(B) 3 4 2C 20A BREAKER (C) 2D 20A BREAKER (D) om site MOO eiw. SUITE 307 ORLWDDR 32819 CUSTOMER. INFORMATION JOHN POLI - MS42500 40S SOUTHEAST GASPARILLA AVENUE PORT ST. LUCIE, FL 34983 (772)834-9428 PV SYSTEM INFORMATION Wire Tag Conduit Wire Qty Wire Gauge Wire Type Temp. Rating Wire Ampacity (A) Temp: Derate Conduit Fill Derate Derated Ampacity (A) Inverter Qty NOC (A) NEC Correction Design Current (A) Ground Size Ground Wire Type SYSTEM SIZE (DC): 14 KW 40 MODULES: LG LG 350NiC-V5 1A TO 1D OPEN AIR 4 12 AWG Trunk Cable 900C 30 0.96 1 28.80 10 1.21 1.25 15.13 06 AWG BARE CU 40 INVERTERS: ENPHASE IQ7PLUS-72-2-US 2A V PVC 2 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 10 1.21 1.25 15.13 08 AWG THWN-2 28 V PVC 2 10 AWG THWN-2 900C 40 0.96 0.7 26.88 10 1.21 1.25 15.13 08 AWG THWN-2 PROJECT INFORMATION 2C 1" PVC 2 10 AWG THWN-2 900C 40 0.96 0.7 26.88 10 1.21 1.25 15.13 08 AWG THWN-2 INITIAL DATE: 2/10/2020 DESIGNER: AKH may, DATE: DESIGNER: 2D 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.7 26.88 10 1.21 1.25 15.13 08 AWG THWN-2 REV: DATE: DESIGNER: 3 1" PVC 3+G 04AWG THWN-2 750C 85 0.96 1 81.60 40 1.21 1.25 60.50 08 AWG THWN-2 THREE LINE DIAGRAM 4 1" PVC 3 04AWG THWN-2 750C 85 0.96 1 81.60 40 1.21 1.25 60.50 THWN-2 �_ VI_� NOTE: LETTER "G" IN WIRE QTY TAB STANDS FOR GROUNDING CONDUCTOR. PV MODULE RATINGS MODULE MAKE LG MODEL LG350N1C-V5 MAX POWER 350W OPEN CIRCUIT VOLTAGE 41.3V MPP VOLTAGE 35.3V SHORT CIRCUIT CURRENT 10.61A MPP CURRENT 9.92A NUMBER OF MODULES 40 UL1703 COMPLIANT YES INVERTER RATINGS VOLTAGE DROP CALCUU NS INVERTER MAKE ENPHASE FORMULA USED PER NEC 2014 HANDBOOK 215.2(A)(4) WHERE APPLICABLE MODEL IQ7PLUS-72-2- WIRE RUN Vmp ImP R L (FT) Vo 0,0 V. US BRANCH TO J-BOX 240.00 12.1 1.98 65.83 3.154 1.31% MAX OUTPUT POWER 290W OPEN DC VOLTAGE 60V ]-BOX TO LOAD CENTER 240.00 NOMINAL AC VOLTAGE 240V LOAD CENTER TO AC DISCONNECT 240.00 MAX AC CURRENT 1.21A AC DISCONNECT TO INTERCONNECTION 240.00 CEC INVERTER EFFICIENCY 97% NUMBER OF INVERTERS 40 UL1703 COMPLIANT YES # OF MODULES PV BREAKER THIS SOLAR PHOTOVOLTAIC SYSTEM COMPLIES WITH THE 2017 SUB PANEL BREAKER SIZE PER BRANCH FLORIDA BUILDING CODE AND THE 2014 NATIONAL ELECTRICAL CODE UP TO 16 1 20A 48.4 I 1.24 I 50.00 6.002 2.50% 60.5 0.308 3.00 0.112 0.05% 60.5 0.308 30.00 0.373 0.16% MAKE MODEL VOLTAGE RATING CONDUCTOR RANGE MAIN ILSCO IPC 4020 600 V 4/0-4 AWG ILSCO IPC 4006 600 V 4/0-2 AWG WIRE SIZE 12 AWG 10 AWG 04 AWG 04 AWG CONDUCTOR RANGE TAP 6-14 AWG 2/0-6 AWG 1. ALL CALCULATIONS FOR VOC, VMAX, IMP AND ISC HAVE BEEN 15. ALL CONDUCTORS MUST BE COPPER. 29. ALL GROUNDING SHALL COMPLY WITH 690A7(A) IN THAT THE CALCULATED USING THE MANUFACTURED STRING CALCULATOR AC MODULES WILL COMPLY WITH 250.64. BASED ON ASHRAE 2% HIGH AND EXTREME MINIMUM TEMPERATURE 16. NEUTRAL AND EQUIPMENT GROUNDING CONDUCTOR BONDED AS PER 30. NO TERMINALS SHALL BE ENERGIZED IN THE OPEN POSITION COEFFICIENTS. NEC 250.24(C). IN THIS AC MODULE SYSTEM 690.17, 690.6. 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690A6 - 250.120 17. EQUIPMENT GROUNDING CONDUCTOR IS CONNECTED TO A PARAGRAPH C). THE GROUND IS CARRIED AWAY FROM THE GROUNDING ELECTRODE SYSTEM PER 250.54(D). 31. WHERE APPLICABLE: INTERCONNECTION SHALL COMPLY GROUNDING LUG USING #6 BARE COPPER WIRE OR #8 THWN-2 COPPER WITH 705.12(D)(3), 705.12(D)(2)(3)(B), 705.12(A) AS PERMITTED WIRE. 18. FUSES FOR PV DISCONNECT HAVE AIC RATINGS OF 200KA AC AND 20KA BY 230.86(6) DC. 3. THIS SYSTEM COMPLIES WITH NEC 2014 19. SUPPLY SIDE CONNECTION SHALL BE MADE USING ILSCO INSULATION INSTRUCTIONS FOR LINE TAPS 4. BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE PIERCING CONNECTORS (IPC). MAKE, MODEL, AND RATING OF LARGEST BRANCH CIRCUIT IN SYSTEM. OTHER BRANCH CIRCUITS INTERCONNECTION CAN BE SEEN ON TABLE 1 BELOW. FIGURE 1: SHALL HAVE LOWER DESIGN CURRENT THAN THE ONE SHOWN. IN 1. ADJUST THE CONNECTOR NUT TO SUITABLE ADDITION, VOLTAGE DROP CALCULATIONS FROM PANELS TO THE 20. METHOD OF INTERCONNECTION CAN BE SEEN IN FIGURE 1. LOCATION 2. PUT THE BRANCH WIRE INTO THE CAP SHEATH FULLY COMBINER BOX SHALL BE SHOWN IN A SIMILAR FASHION 21. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC 3. INSERT THE MAIN WIRE, IF THERE ARE TWO LAYS OF 5. ALL CONDUCTORS ARE SIZED BASED ON NEC 2014 ARTICLE 310 SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. INSULATED LAY IN THE MAIN CABLE, SHOULD STRIP A 22. WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL CERTAIN LENGTH OF THE FIRST INSULATED LAY 6. ALL EQUIPMENT INSTALLED IS RATED AT 75-C EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC ARTICLEFROM INSERTED END 110.26. 4. TURN THE NUT BY HAND, AND FIX THE CONNECTOR IN 7. INVERTER NOC (NOMINAL OPEN CURRENT) OBTAINED FROM SUITABLE LOCATION. EQUIPMENT DATASHEET 23. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT 5. SCREW THE NUT WITH THE SLEEVE SPANNER. RESISTANT PER NEC ARTICLE 300.6 (C)(1) AND ARTICLE 310.8 (D). 6. SCREW THE NUT CONTINUALLY UNTIL THE TOP PART 8. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL IS CRACKED AND DROPPED DOWN LOCAL AND NATIONAL CODE REQUIREMENTS. 24. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.8 (C). 9. EACH MODULE MUST BE GROUNDED ACCORDING TO USER INSTRUCTIONS 25. TOTAL AREA OF ALL CONDUCTORS, SPLICES, AND TAPS INSTALLED AT ANY CROSS SECTION OF THE WIRING DOES NOT EXCEED 75% OF THE 10. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(D) CROSS SECTIONAL AREA OF THE SPACE. NEC 312.8(2). 11. PER NEC 690.17, PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE 26. SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DC TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER, JUNCTION BOX, THE OPEN POSITION> SIGN SHALL READ *WARNING - ELECTRIC SHOCK DISCONNECT. AND COMPLIES WITH 600.6 - NO DC DISCONNECT AND HAZARD - DO NOT TOUCH TERMINALS - OR EQUIVALENT. ASSOCIATED DC LABELING ARE REQUIRED. 12. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY 27. SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT LABELING AS PER 690.56(C). AC VOLTAGE AND SYSTEM OPERATING SERVICE ENTRANCE. CURRENT SHALL BE PROVIDED 690.52. 13. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 690.64 28. CONDUCTORS IN CONDUIT ARE AC CONDUCTORS BRANCH CIRCUITS AND NOT PV SOURCE CIRCUITS. 690.6. 14. AND OPTION FOR A SINGLE CIRCUIT BRANCH TO BE SPLIT INTO TWO SUB -CIRCUIT BRANCHES IS ACCEPTABLE. • PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAP-COM ENGIN ICE F'•. 'i o RE 75 ZZ i A ••• STATE OF • S/j41� cl El7AQ. , ®0 OIIIO�a I SOLAR CONTRACTOR J 5728 MAIOR BLVD. SODS 307 ORLANOO R. 32819 CUSTOMER INFORMATION JOHN POLI - MS42500 405 SOUTHEAST GASPARILLA AVENUE PORT ST. LUCIE, FL 34983 (772) 834-9428 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 14 KW 40 MODULES: LG LG 350NlC-V5 40 INVERTERS: ENPHASE IQ7PLUS-72-2-US PROJECTINFORMATION INITIAL DATE: 1/10/2020 DESIGNER: AKH REV: DATE: DESIGNER: REV: DATE: I DESIGNER: ELECTRICAL (VOTES PV-4.1 (�%� .. • . - 0MAIN SERVICEPANEL PRO CUSTOM SOLAR LUC MOMENTUM, ��Am ��.91m7mnsOLAR (732)902-6224 PROFESSIONAL .. ENGINEERING OWARNING OWARNING O THIS EQUIPMENT FED PHOTOVOLTAIC POWER SOURCE BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES. EXCLUDING COMBINERBOX MAIN SUPPLY PHOTOVOLTAIC SYSTEM OVERCURRENT DEVICE, SHALL NOT EQUIPPEDWITH EXCEED AMPACITY OF BUSBAR. RAPID SHUTDOWN T_ r. �WARNING - PIE 75 .- .�,. qp O O ELECTRICAL SHOCK HAZARD DO TOUCH • BOX - ' NOT TERMINALS NE AND TERMINALS ON BOTH LIo - STATE OF -. LOAD SIDES MAY BE ENERGIZED ORIO IN THE OPEN POSITION PHOTOVOLTAIC SOLAR AC DISCONNECT 0 W;AR N I N G OPERATING CURRENT 48.40A - " ELECTRICK HAZARD DO NOTTERMINALSOPERATION VOLTAGE 264 V TERMINALTH LINE ANDLOAD • • •PHOTOVOLTAIC SIDEE ENERGIZED SYSTEM IN THPOSITION • • o _"'.w . INSTALLED BY MOMENTUM SOLAR 325 HIGH STREET JWARNING i METUCHEN, NJ 08840 wARNMG Reemcs¢cKw,zuto CUSTOMER INFORMATION PHONE NUMBER:732-902-6224 °� r ��^ I` uy��F.f ..�z • O 4%ACO aNECT , --- C, nc oscauuecr r „ SOUTHEAST LINE SIDE TAP OWAJVOLTAGE .. �wr 428 '• • DUAL PO �Z © SECOND SOURCAIC S DISCONNECTMAIN - SYSTEM SIZE (DC): 14 KW PANEL -. -•MODULES: NOMINAL AC OPE40 V '•RATED AC OPERA.A I `+ I[I[ Y•9 sPROJECT INFORMATION 1/10/2020 NINGDATE: O:POWER DSOURCESECONDPHOTOVOLTAICM =] • wARY;hY 9 F ® momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 RkMILTON BLVD, SOUTH PLAINFIEID, NI (732)902.6224 MOMENTUMSOLARCOM Daniel W. Dunzik Architect LEED-AP Daniel W. Dunzik Architect LEED-AP PROFESSIONAL 370 Burnt HIB Rd. Skillman NJ.08558 . 908-872-3664 ENGINEERING 370 Burnt Hill Rd. Skillman NJ.08558 908-872-3664 StudioGdesign@comeast.net January 10, 2020 SmdloGdesign@comeasLnet January 10, 2020 Re: Proposed Photovoltaic Solar Panel Installation Gravity Load Calculation Criteria John Poli Structural Design Loads per ASCE 7-10 405 SE Gasparilla Ave Port St. Lucie, FL 34983 Dead Loads = 10 psf+2.6 psf (new solar panels) = 12.6 psf Roof Live Load = 20 psf Dear Plan Reviewer. Ground Snow Load = 0 psf Certification: I have reviewed the engineering testing reports for the racking and attachments to be used on this // project and I certify that the products are capable of supporting the code required loads and am suitable for this Wind Load Calculation Criteria ♦♦� , .. installation when installed in strict compliance with the manufacturers printed instructions. Wind Loads per ASCE 7-10, Ch. 30 method 1 IN, IGE S •' �� Using an area of 10 SF, wind loads from Figure 30.5-1: Regarding the solar panel army installation on the above referenced project please note that an inspection was Zone 1 =-06.1 psf Roof Slope = 1 degrees Roof Mean Height =15 ft o PE 75 performed by a representative of the Architect/Engineer of Record, and analysis of the existing structure was Zone 2 =-77.3 psf Basic Wind Speed = 160 mph = conducted. There is adequate structural capacity for the installation of the army with the following recommendations: Zone 3 = -116.3 psf Exposure = B t Ah �'tj ': L The army will be installed on the existing roof. The roof framing is constructed of 2"x4" wood millers @24" o.c. spanning 15'9" with 1/2" plywood sheathing. The new army (See Site map by contractor) will add 2.63 Lb. / St. Per section 2.4.1, ASD combo = D + 0.6W: .• `_ ®••• STATE OF R overall to the roof. No additional structural support is required for the roof structure. Zone I =2.6 psf+0.6(-46.1 psf)=-25.1 psf i '•.FG OHID1',. •' ��� 3.8 psf 4-67.2 AL Zone 3 = 2 6 psf+ 0.6(-116.3 psf) psf I Jill 2. 2. The system shall be secured to the roof using the "SnapNrack" "ltra URail" ® attachment system. The installation shall be in strict compliance with manufacturers printed instructions. The attachment system shall be UL 1703 Check Attachment to Wood Rafter approved tested. The attachments shall be min. 5/16" x 4" long stainlesa-steel lags with a min. embedment of 3" into the rafters. Attachments shall be @ 48" o.c. Max. in roof wind zone 1 and @ 24" o.c. Max. in roof wind zone 2 & 3, Use 5/16 dia. Lag screw w/ 3" embedment into 2 in. wide roof rafter lags to alternate rafters. Provide 6 mil. vapor barrier between dissimilar metals. Provide water tight gasket and sealant Lag Screw Spacing: Lag Screw Tributary Area: at all penetrations. Attachments shall follow panel rows as specified by the system manufacturer's installation Zone I = 48" o.c. max Zone 1 = (48" o.c. max)^2 / 144 = 16 SF manual. The panel angle shall match the roof slope. Zane 2 = 24" o.c. max Zone 2 = (24" o.e. max)^2 / 144 = 4 SF SOLAR CONTRACTOR Zone 3 = 24" o.c. max Zone 3 = (24" o.c. max)A2 / 144 = 4 SF CAMERON tlIMI NSEN CERTIFIED SOLAR coNTRAcmR 3. Solar Modules shall be UL-1703 rated Refer to manufacturers specifications sheets. Lag Screw Forces: W = 2661b/in (Table 12.2A, 2015 NDS) M OMENTUMSE LV6)036 SOLAR Zone I — 25.1 psf x 16 SF - 402 lb < W , OK Cd = 1.6 (Table 2.3.2, 2015 NDS) s72e MAIoa LVD.SUM 307 oewxoo Bs 4. Positive drainage of the system shall be so as not to void the existing roof warmaty. Zone 2 = 43.8 psf x 4 SF — 175 lb < W', OK Ct = I (Table 2.3.3, 2015 NDS) CUSTOMER INFORMATION 5. All aspects of the installation shall comply with the Florida Administrative Code, 2017 Florida Building Code - Zone 3 = 67.2 psfx 4 SF = 269 lb < W, OK W = W x embed x Cd x Ct Residential Sixth Edition, ASCE-7-10, 2017 Florida Building Code — Energy Conservation, Sixth Edition, 2014 W' = 266 lb/in a 3 in. x1.6 x 1 = 1276.8 lb JOHN POLL - MS42500 National Electric Code, All Local Governing County and Municipal Ordinances adopted by reference or enacted by 405 SOUTHEAST GASPARILLA AVENUE law. All components used meet the criteria of the Florida Solar Energy Center. PORT ST. LUCIE, FL 34983 6. Please refer to the attached structural calculations. - 772) 834-9428 PV SYSTEM INFORMATION If you have any questions relating to this matter, please contact me at your earliest convenience. Thank you. SYSTEM SIZE (DC ):14 KW 40 MODULES: LG LG 350NIC-VS 401NVERTERS:ENPHASE IQ7PLUS-72-2-US Daniel W. Dunzik, RA, LEED-AP FL. Lic. No. AR98795 PROJECT INFORMATION INITIAL DATE: 1/10/2020 DESIGNER: AKR REV: DATE: DESIGNER: REV: DATE: DESIGNER: STRUCTURAL CERTIFICATION PV-5