Loading...
HomeMy WebLinkAboutProduct Approval UnderlaymentProduct Approval dbpr USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL12328-R8 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer TAMKO Building Products LLC Address/Phone/Email PO Box 97 Galena, KS 66739 (417) 624-6644 Ext 2305 kerri_eden@tamko.com Authorized Signature Kerri Eden kerri_eden@tamko.com Technical Representative Kerri Eden Address/Phone/Email PO Box 1404 Joplin, MO 64802 (417)624-6644 Ext 2305 kerri_eden@tarrko.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R. Priest Evaluation Report ASTM D1970 Florida License PE -74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/18/2021 Validated By Locke Bowden P.E. Certificate of Independence Referenced Standard and Year (of Standard) " Validation Checklist - Hardcopy Received FL12328 R8 COI TBP14001.4 2017 FBC Eval Report TAMKO Underlayments final pdf Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D4869 2016 ASTM D6380 2003 TAS 103 1995 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 10/05/2017 10/19/2017 10/20/2017 12/12/2017 FL # Model, Number or Name Description 12328.1 ! ASTM Slate Surfaced Roll Roofing Roll roofing surfaced with mineral granules j Limits of Use _ Installation Instructions Approved for use in HVHZ: Yes FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO Approved for use outside HVHZ: Yes Underlayments finai.pdf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlayments final.pdf Created by Independent Third Party: Yes 12328.2 j ASTM Tile Underlayment Coated organic underlayment Installation Instructions Limits of Use Approved for use in HVHZ: Yes FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO Approved for use outside HVHZ: Yes Underlayments finaLpdf Impact Resistant: N/A Verified By: Zachary R, Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlayments finaLpdf Created by Independent Third Party: Yes 12328.3 Master Smooth Asphalt saturated organic underlayment. Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R8 II TBP14001.4 2017 FBC Fval Report TAMKO Approved for use outside HVHZ: Yes Underlayments final.pdf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlayments final.pdf Created by Independent Third Party: Yes `moisture 12328,4 Guard A self -adhering modified bitumen underlayment. Limits of Use Installation Instructions w Approved for use in HVHZ: Yes FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO Approved for use outside HVHZ: Yes Underlayments finai.pdf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO i Underlayments final.pdf Created by Independent Third Party: Yes 12328.5 ! No. 15 ASTM Asphalt saturated organic felt W Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL1232-8 R8 II TBP14001.4 2017 FBC Eva[ Repart TAMKO Approved for use outside HVHZ: Yes Underlayments finaLpdf Impact Resistant; N/A Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Design Pressure: N/A Other; See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001,4 2017 FBC Eval Report TAMKD Underlayments final.pdf Created by Independent Third Party: Yes 12328.6 T No. 15 UL Asphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO i Approved for use outside HVHZ: Yes Underlayments final.pdf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKD Underlayments final.pdf Created by Independent Third Party: Yes 12328_ i No. 30 A ; . Asphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL12328 R8 IITBP14001.4 2017 FBC Eval Report TAMKD Approved for use outside HVHZ: Yes Underlayments fina1.pdf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Fval Report TAMKD Underlayments final.pdf Created by Independent Third Party: Yes 12328.8 No. 30 UL Asphalt saturated organic felt Limits of Use Installation Instructions j Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes FL12328 R8 1I TBP14001.4 2017 FBC Lval Report TAMKD Underlayments final.pdf Impact Resistant: N/A Verified By; Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports j FL12328 R8 A€ TBP14001.4 2017 FBC Eval Report TAMKD Underlayments final.pdf Created by independent Third Party: Yes i 12328.9 TAM -FELT Alternate to ASTM D 226, Type Ii underlayment i Limits of Use Approved for use in HVHZ: Yes Installation Instructions T Approved for use outside HVHZ: Yes FL12328 R8 11 TBP14001.4 2017 FBC Eva] Report TAMKD Underlayments final.pdf Impact Resistant: N/A Verified By: Zachary R. Priest PF -74021 Design Pressure: N/A Created by Independent Third Party; Yes Other: See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlayments final.pdf Created by Independent Third Party: Yes 12328.10 TW Metal and Tile Underlayment self -adhering modified bitumen underlayment Limit Approved for use in HVHZ: Yes Installation Instructions Approved for FL12328 R8 II T131314001.4 2017 FBC Eval Report TAMKO Underlayments final,pdf use outside HVHZ: Yes I Impact Resistant: N/A I Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKD Underlayments final.pdf - Created by Independent Third Party: Yes i 12328.11 TW Underlayment self -adhering modified bitumen underlayment Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKD Approved for use outside HVHZ: Yes Underlayments final.pdf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Other: See evaluation report for limits of use. Created by Independent Third Party: Yes Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlayments final.pdf Created by Independent Third Party: Yes Contact Us :: 2641 Blair Stone Road, Tallahassee FL 32329 Phone: 850-487-1824 The State of Florida is an AA/EEO employer, Gopy�ht 2447-2 13 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. if you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 854.487.1395. *Pursuant to Section 455.275(l), Florida Statutes, effective October 1, 2412, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 4S5, F.S., please click here . Product Approval Accepts, M. E Credit Card Safe 5 CREEK TECHNICAL SERVICES, LLC EVALUATION REPORT Manufacturer: TAMKO BUILDING PRODUCTS, INC. P.O. Box 1404 Joplin, MO 64802 (417)624-6644 http://www.tamko.com Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1 Properties: Physical properties PRODUCT DESCRIPTION Certificate of Authorization No_ 29824 17520 Edinburgh Drive Tampa, FL 33647 (813) 480-3421 FLORIDA BUILDING CODE, STH EDITION (2017) Issued October 19, 2017 TAMKO® ASTM Slate ASTM D 6380, Class M, Type II underlayment constructed from organic felt saturated Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules. TAMKO® ASTM Tile ASTM D 6380, Class M, Type II underlayment constructed from an organic felt saturated Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules. TAMKO® Master ASTM D 6380, Class S, Type IV underlayment constructed from an organic felt saturated Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For use in non-HVHZ only. TAMKO@ Moisture Guard@) Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane with a mineral surfacing and a removable release film on the adhesive side and removable selvedge release tape. TAMKO® No. 15 ASTM ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt TAMKO® No. 15 UL ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt TA.MK,O@) No,_30 ASTM ASTM Type I unglerlayment constructed from a non -perforated organic felt that is Asphalt'Saturateil= sat t- d Organic Feit TAMKO® No. 30 UL ASTM D 226, Type II underlayment constructed from a non -perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt TAMKOO TW Metal and Self -adhered, flexible, ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side. TAMKOO TW Underlayment Self -adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a polymer film on the surface and a removable release film on the adhesive side, TBP14001.4 FL12328-R8 Page 1 of This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CRFEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEKTAMKO BUILDING PRODCUTS, INC. TAMKO Underlayments TECHNICAL SERVICES, LLC TAMKO@ TAM -FELT Alternate to ASTM D 226, Type I and Type II underlayment constructed from a non- perforated organic felt that is saturated with asphalt. APPLICATION METHOD Installation shalt be in accordance with the published manufacturers installation instructions, the FBC, and the requirements below. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1l8" gap at abutting joints. The minimum application temperature shall be 50°F except as follows: a) The minimum application temperature of TAMKO@ TW Metal and Tile Underlayment and TAMKOO TW Underlayment shall be 40°F. b) The minimum application temperature of TAMKO@ Moisture Guard@ shall be 35°F. The minimum roof slope shall be in accordance with FBC requirements except as follows: a) The minimum slope of TAMKO@ ASTM Slate Surfaced Roll Roofing shall be 2:12. Underlayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shall exposure exceed 30 days. Exception. TAMKOO TW Metal and Tile Underlayment may be exposed for a maximum 90 days. Self -adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ. All roof coverings shall be mechanically fastened through the underlayment to the roof deck. Allowable Roof Coverings: s. } pen valley applicahons per 9507.2.9.2 2) Wood shingles only TBP14009.4 FL12328-R8 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 69G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Metal hoof Mineral Wood Underlayment Asphalt Shingles Panels and Surfaced Roll Shingles and Slate Clay and Shingles Roofing Shakes Shingles Concrete Tile TAMKOO ASTM Slate Y , Surfaced Roll Roofing N N N N Y TAM KOV ASTM Tile Underlayment N N N N N Y TAMKO@ Master Smooth Y' N N N N N TAMKOO Moisture Guard@ Y N N N N N TAMKO@ No. 15 ASTM Asphalt Saturated Organic Y Y Y Y N N Felt TAM KO@ No. IS UL Asphalt Saturated Organic Felt Y Y Y YZ Y N TAMKO@ No. 30 ASTM Asphalt Saturated Organic Y Y Y Y Y Y Felt TAMKO@ No. 30 UL Asphalt Saturated Organic Felt Y Y Y N Y N TAMKO@ TW Metal and Tile Underlayment Y Y N N N Y TAMKO@ TW Underlayment Y Y N N N N TAMKOO TAM -FELT Y N N N N N s. } pen valley applicahons per 9507.2.9.2 2) Wood shingles only TBP14009.4 FL12328-R8 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 69G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODCUTS, INC. TAMKO Underlayrnents TECHNICAL. SERVICES, LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance in not within scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Contact the manufacturer when installing at temperatures below the minimum application temperature. 5) Unless otherwise stated, the minimum roof slope shall be in accordance with FBC requirements. 6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in successive courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 7) The underlayment may be used as described in other current FBC product approval documents. 8) The underlayment shall not be installed over existing roof coverings. 9) Contact the manufacturer regarding specific exposure limits for each underlayment. 10) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST6049) TAP -192-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) TAP -193-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) TAP -214-02-01 ASTM D 4869 2016 PRI Construction Materials Technologies (TST6049) TAP -215-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST6049) TAP -216-0203 ASTM D 6380 2003(2013) PRI Construction Materials Technologies (TST6049) TAP -217-02-01 REV ASTM D 6380 2003(2013) PRI Construction Materials Technologies (TST6049) TAP -218-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST6049) TAP -21902-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST6049) TAP -220-02-01 ASTM D 6380 2003(2013) PRI Construction Materials Technologies (TST6049) TAP -222-02-01 ASTM D 4869 2016 PRI Construction Materials Technologies (TST6049) TAP -245-02-01 TAS 403 1995 ASTM D 4798 2011 PRI Construction Materials Technologies (TST6049) TAP -311-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) TAP -319-02-01.1 ACC 188 2012 PRI Construction Materials Technologies (TST6049) TAP -387-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) TAP -388-02-01 ASTM D 1970 2015a UL LLC (TST9628) 13CA12269 ASTM D 226 2009 TBP14001.4 FL12328-R8 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3_ The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TAa MKO BUILDING PRODCUTS, INC. TAMKO Underlayments TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R_ Priest, P.E. have demonstrated compliance with the Florida Building Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. ` VIVItI111111tr �C, E N,3 �F�,`'., 2017.10.19 No 74021 / 12:15:58 --04'00' S TATE O F ' CCl Z. 4�. �411: O R ! O ?.•`���: Zachary R. Priest, P.E. jj0 N A` ��� ` FloridOrganization No.on No. ANE9641029 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, R.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT TBP14001.4 FL12328-R8 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.