HomeMy WebLinkAboutProduct Approval FL#: FL 11842.3 R4
Date: 07/09/17
®® ® �� Report No.: 17-131-UHT-ER
®V Page 2 of 5
. N
Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064
Manufacturer: . MFM Building Products Corp.
525 Orange Street
Coshocton,Ohio 43812
(740) 622-2645
www.mfmbp.com
Product Name: "Ultra HT Wind&Water Sea 1`1
Product Categczry. Roofing
Product Sub-Category Underlayment
-Corn-1.1--nice A;:t4.od: State Product Approval Rale 61G20-3.005 (1) (d)
Product Description: "Ultra HT Wind &Water SealT""' is self-adhering membrane composed of a white,
non-slip cross-laminated polymer filn., larninated to a rubberizes; asp;Talt adhesive
with a split release liner designed for use as a roof underlayment in high
temperature conditions.
Product Material/ Material Type: Styrene Butadiene Styrene(SBS)
Standards: Material shall comply with ASTM D 1970 per Florida Building Code FBC 6th Edition
(2017),Chapter 15.
Product Dimension(s) Roll Size:36 in.x 67 ft. rolls
Thickness:45 mils(nominal)
Substrate(s): *(Ultra HT Wind & Water Seal"" has been evaluated for application to the
following substrates(Design of support is outside the scope of this evaluation):
Plywood
• Dens Deck
installation: Goise:al Installation Instructions:
"Ultra HT Wind &Water SealT'" shall be installed in accordance with the attached
installation method and in compliance with applicable code sections of the FBC
6th Edition (2017), subject to the Limitations and Cond ions of Use--listed iriI(;`iS
Evaluation Report.
Refer to installation details at the end of this report. Refer to manufacturer's
installation instructions as a supplemental gj 1ie for attachment.
ZCV5,` oKL9
REV'EWEI 0
�CE
CODE COMPLIANCE
OMPL I-�C
ST. LUCIE C® FILE COPY
B®Cc
l
FL#: FL 11842.3 R4
Date: 07/09/17
Report No.:17-131-UHT-ER
Page 3 of 5
SpeelaltLJ Structural Englneering MUCK,Inc.Certificate of Authorization#8064
Performance Standards: The product described herein has demonstrated compliance with:
• ASTM D 1970-15a — Specification Self-adhering Polymer Modified
Bituminous Sheet Materials Used as Steep Roof Underlayment for ice Dam
Protection
Standards Equivalency: The ASTM D 1970-01 standard version used to test the product meets the
prescribed standards in ASTM D 1970-15a standard version adopted by the
Florida Building Code 6-ith Edition (2017)for use as cvaluatc_d in ilfis repo
Code Compliance: The product(s) described herein have demonstrated compliance with the
performance standards listed above as referenced in the current Florida Building
Code.
Evaluation Report Scope: This product has been evaluated in compliance with the building envelope
requirements of the Florida Building Code, as related to the scope section to
Florida Product Approval Rule 61G20-3.001.
Product Linaita-dons and a Deck shall be in compliance with applicable building code.
Conditions of Use: • Minimum slope shall be 2:12 or greater.
• Installation is limited to use with approved roof coverings that are
mechanically fastened through the undedayment and is attached to the
sheathing or rafters.
• Not to be applied over active solvents or sealants, EPDM rubber or products
containing silicone.
• Do not expose product to direct sunlight for more than 60 days.
General Limitations and • Scope of"Limitations and Conditions of Use"for this evaluation
Conditions of Use: This evaluation report for "Optional Statewide Approval' contains technical
documentation, specifications and installation method(s) which include
"_.Sf;iC t ii?SZS and Con'di;ons of Use" tlerCil.iv31out the r apart in accordance with
Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is
the authority to approve products under"Optional Statewide Approval'.
• Option for application outside-"Limitations.and Conditions of Use"
Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific
approval by the local authorities having jurisdiction in accordance with the
a l."larnotL ",nd @;.zho6zed in she Code'.Any modification of
the product as evaluated in this report and approved by the Florida Building
Commission is outside the scope of this evaluation and will be the
responsibility of others.
• This report is a building code product evaluation per FLPE rule (FAC) 61G15-36
to comply with Florida product approval rule (FAC) 61G20-3. This evaluation
report is part of the Florida Building Commission approval for the listed code
related criteria. This report by James Buckner, P.E. and CBUCK Engineering is
FL#: FL 11842.3 R4
Date: 07/09/17
CBUCK Engineering Report No.: 17-131-UHT-ER
Page 4 of 5
Specialty Structural engineering CBUCK,Inc.Certificate of Authorization#18064
not a design certification of code compliancy: construction submittal
documentation, per FBC section 107, for any individual structure, site specific
or permit design.
a Design of support systern is outside the scope of this report.
• Fire Classification is outside the scope of Rule 61G20-3, and is therefore not
included in this evaluation.
• This evaluation report does not evaluate the use of this product for use in the
High Velocity Hurricane Zone code section. (Dade&Broward Counties)
Quality Assurance: The manufacturer has dei-honstrated compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.0005 (3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity through Keystone Certifications, Inc. (FBC Organization.ID#QUA
1824).
e;e;eia ed Data: 1. ASTM D 1970-01 Test
By PRI Construction Materials Technologies, Inc.
(FBC Organization ID#TST 1556)
Report No. WIFM-039-02-01., Data: 8/75/13
2. Equivalency of Test Standard Certification
By Jarnes L. Blue n*r, P.E. @ CBUCK Engineering
(FBC Organization#ANE 1916)
3. Quality Assurance
Keystone Certifications, Inc. (FBC Organization ID#QUA 1824)
MFM Building Products Corp. Licensee#335
4. Cl-rdfication of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization#ANE 1916)
FL#: FL 11842.3 R4
Date: 07/09/17
C B 11.01 C a F-Ck": r-.-n n L=L=r ng Report No.: 17-131-UHT-ER
Page 5 of 5
SpL clalfiy Structural Englneprinq CBUCK,Inc.Certificate of Authorization#8064
MFM Building Produas Corp.
Ultra HT Wind Un
&Water
cIf-tt��1d"hesred t oc4lnb derlayrnent
General Installation Instructions:
• Product to be applied directly to a clean dry surface.
• Prime any weathered surfaces. Dens Deck must be primed with asphalt base primer.
• Starting at the low point of the deck, peel back 12"of the release liner, align the membrane and press into
place onto roof deck.
• Adhesive is pressure-activated, so press firmly into place using uniform pressure with a 2-3" heavy steel or
rubber roller to seams and overlap.
• Overlap end laps a minimum of 6".Side laps must be a minimum of 3".
• Store product in the carton in a dry place until ready to use. Keep product out of direct sunlight.
• Apply membrane only in fair weather when the air,surface and membrane are at a minimum temperature
of: 50°F
• Not to be applied overactive solvents or sealants, EPDM rubber or products containing silicone.
• Do not expose product to direct sunlight for more than 60 days.
"Ultra HT Wind & Water SeaIT""' shall' be installed in accordance with.the attni hed installation method and in
compliance. with applicable code sections of the FBC 6th Edition (2017), subject to the Limitations and
Conditions of Use listed in this Evaluation Report.
Refer to installation details at the end of this report. Refer to manufacturer's installation instructions as a
supplemental guide for attachment.
Product Illustrations
LTR%A HT
WIND&WATER SEALTm
wvv
kS?dU Ei.knl d'.{-{1..
Z__