HomeMy WebLinkAboutProduct Approval (2) iProduct Report Manufactur- Ext- reme, - • •
2160 SW Poma Drive
Palm City, FL 34990
( 772) 872-8034
Product Approval
Compliant with Florida Building Code 2017 (6`h ed.)
Compliant with Florida Product Approval Rule #61G20-3
Compliant : Keystone Certifications
Product: 5 V Crimp 26GA Metal Roofing Panel Corrosion Resistant FBC Sec. 1507.4.3
Yield strength:40ksi Steel Attached to min. 15/32" plywood or Wood Deck w/ min.
Attached 24" 0.42 specific gravity with screws.24" Coverage
Coverage Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec. 1506, 1507
Fastener for Method 1 Attachment#9-15 x 1"Hex Head w/EPDM Bonded Steel Washer
to penetrate 3/16"thru wood decking
Fastener for Method 2 Attachment#9-15 x V Hex Head w/EPDM Bonded Steel Washer
to penetrate 3/16"thru 15/32"min. plywood deck or 5/8"into wood plank
Underlayment: To be compliant with FBC Sec.1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
Install Details: Table A Allowable Loads METHOD 1 METHOD 2 FASTENER PLACEMENT
DESIGN PRESSURE* -85 PSF -114.25 PSF METHOD 1 IN RIB PEAKS
ROW SPACING 12"D.C. 121,O.C. METHOD 21N PANEL FLATS
FASTENER SPACING 12" D.C. 12"D.C. *SEE INSTALL DRAWINGS
FASTENER SIZE: #9 #9
*ALLOWABLE DESIGN PRESSURE MARGIN OF 2 T01
Reference Data: HURRICANE TEST LAB#TST ID: 1527
TAS 125-03 Test#0223-0307-01;METHOD 1 - (UL 1897-041)
TAS-125-03 Test#0223-0517-06,METHOD 2
EQUIVALENCY UL 1897-04 IS EQUIVALENT TO UL 1897-12 TEST STANDARD * DESIGN PRESSURE SAFETY MARIGIN 2:1
Certificate of Independence:
Locke Bowden,P.E.does not have,not will acquire a financial interest in any company manufacturing or distributin products
under this evaluation. �ti���e I11 rrr f th
Locke Bowden,P.E.is not owned,operated,or controlled by_an company,manufacturer,or distribuNggf-ailta9.4it•t�iiS
report. �r-"uall� Jc
` rG
MAY 2 c`J05a$ )2'1. :
ST. Luc' S i,1.i E 0F '.4�=
PL INCE OR ''CODECOM _
B®CC
Compliance Statement: These products herein evaluated have demonstrated compliance with the Florida Building Code 2017
6th ed.,with referenced documents submitted.
Limitations:
1. Underlayment to be compliance with current Florida Building Code 2017 6th ed-,Section 1507.1.1
2. Products are compliant for State of Florida.product approval per Rule 61G20-3
3. Compliance Method: 1-D
4. Fire classification is not part of this acceptance.Shear diaphragm values are outside this report.
5. All support framing compliant w/Florida Building Code 2017,Chapters 22 for Steel,23 for Wood and 16 for
Structural Loading.Design of support and attachment to the framing is outside the scope of this evaluation.
6. Rule 61G20-3 allows for engineering analysis by registered/licensed others for"project specific approval"by local
authorities,authorized by the code,and is the responsibility of others.
7. This report does not imply warranty,installation,recommended product use outside of this report.
FFasteners-
4�9-15 Hex-Head Screws With SV-CriffV Roof Panel
EPDI11 Bonded Steel Ih'ashers
1l� :r,: ;r r .its• :'W ,,. iite : , �, a,u. i _i; �. to .
3Lri�-a:�S:>illl��;l,,.h�ac'�:11=9i:1!W.�uS,:u��,l:��.'v>:'3fl�c<:c'>Lii.� :atl:':Le:�.l;;•yil:<�•t'• w1 r. � '�I
Deck:
-15!37'or greater Plywood,or
-Wood plank
Fasteners-
*-15 Hex-Head Screws With 5V Crimp`° Roof Panel
EPDM Bonded Steel Washers
.C�I�;I ',L';'�U.tr JL �ylit. rr.z�a�ty�::u t n,r. �i1•`-1'' ilil:•�;ia,-=.�' � iu ;4�,:y ti;' '• ih.��
Ja
ZZ Ja
n a li r
��1��llr...l���i�ilo•x1t;.T�,�yS�E;li;;�IL''>•;1ti�=:;tira�lt;"."��-.��✓.�:i).! rtiu:�tlu::'d11:;:�1.l4� Lc l�f,?``�Ilk�j��jf
Deck:
-15132"or greater Plywood,or
-Wood plank
Oroduct ReportFabricators,
2160 SW Poma Drive
Palm City, FL 34990
772)872-8034
Florida Product •
Ii
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule #61G20-3
Compliant: Keystone Certifications
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min. 15/32"plywood or Wood
Deck w/min.0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1 (Method 1 Attachment): #9 x 1-1/2" Hex-Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method.2,3,&4 Attachment):#10 x 1-1/2" Hex-Washer Head wood screw* to
penetrate 3/16" min.thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
.dee Fastener attachment specirieations above
Install Details: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4
DESIGN PRESSURE_* -86 PSF -93.5 PSF -101 PSF -228 PSF
ROW SPACING 16"o.c. 16"o.c. 8"O.C. 6"o.c.
FASTENERSPACING (ALONG Panel width) 12"o.c. 12"o.c. 12"o.c. 12"o.c.
FASTENER SIZE #9 #10 #10 #10
Reference Data: ARCHITECTURAL TESTING, INC.TST ID#:1527
UL 580-06& 1897-041 Test Report 1M893.01-450-18 05/02/24
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCT(--UL 1897-04 is equivalent to test standard UL 1897-1 *Design pressure margin of safety 2.1
Locke Bowden,P.E.does not have,not will acquire a financial in i o�' F•eQ 40m1*gfacturing or distributing products
under this evaluation. %'
Locke Bowden,P.E.isnot owned,operated,or controlled by a&comparftilprnlibii7 Mures,or distributing products under this
report. ; .?
.4
Sit TE
f �',�it•.�CQf�10��'1�4�
:I. NAL
i
.�
c;
t
r t ,
s�
r
d
.y� X
FL17O22.1 5V Crimp (26GA Steel), 24" Wide Roof Panel -Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code(FBC)2017 6th ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
4. Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBG 2017 6th ed., Chapter 22 for Steel, Chapter-23 for Wood and Chapter 16 for
Structural Loading.
7.This report does not imply warranty, installation, recommended product use outside of this report.
Fasteners-
#9 x 1-112'Min.ar
#10 x 1-112'Min.perTab/a A'for Row 5-V Qirrip Roof Panel
Spacing and Design Pressures
Hex Washer Head Wood Screws
10
�v � •U
ti
1
Deck
15132"or greater Plywood,or
Wood plank
24-
1�'
318"
fJPT10PL1t.S'rRIATIOFki
Panel Profile
Nominal 12" Nominal 12"
o.c. O.C.
Fasten
9 X -1/2"Min. or #10 x 1-1/2"Min.per
Table"A" Hex Washer Head Screw
Spaced 12"o.c.across the Panel Wdth
Panel Refer to Table"A"for Spacing Along Panel
Overlap Length
Deck-15/32"or greater
Plywood,or
-Wood plank
NCBUCK
Sp=clalti.,l Structural Eng1neering CBUCK,Inc.Certificate of Authorization#8064
Evaluation Report rGGrZyVcii
"Ultra HT Wind & Water Sea ITM" MAY 21 2020
Roof Underlayment ST. Lucie County, Permitting:
Manufacturer:
MFM Building Products Corp.
525 Orange Street
Coshocton, Ohio 43612
(740) 622-2645
- for
Florida Product Approval
# FL 11842.3 R4
Florida Building Code 6th Edition (2017)
Method: 1 - d
Category: Roofing
Sub - Category: Underlayment
Product: "Ultra HT Wind &Water Seall "
.Description: Self-Adhered Underlayment
Facsimile of digital copy signed by
Prepared by: James L.Buckner,P.E.
Electronically signed and sealed documents shall
James L. Buckner, P.E.,SECB comply with the provisions of FAC Rule 61G15-23.
Florida Professional En ineer#31242 ""',11
Florida Evaluation ANE ID: 1916 SUC��L
����.•'��CENSF'•..F��:
Project Manager: Diana Galloway ;*:: •:
Report No. 17-131-UHT-ER _ Nos1za2 _
(Revises 15-115-UHT-ER,FL11842.5 R3) UJ Z
Date: 07/09/17
'n STATE OF
ORI
Contents:
Evaluation Report Pages 1—5
2017.08.28 14:49:18-04'00'
CBUCK,Inc.dba CBUCK Engineering
Phone:(561)491-9927•Email:cbuck@cbuckinc.net•Website:www.cbuckinc.net
Business:1374 Community Dr.,Jupiter,FL 33458-Corp/Mailing:2637 E.Atlantic Blvd,#34069,Pompano Beach,FL 33062