Loading...
HomeMy WebLinkAboutConstruction PlansS 0 E [-N r1 K RECEIVED JAN 2 3,.16" krMjttln9 DePynrnent St. Oct, �G 0 -- — — C — — —— Equal --t Equal Br Plan View Scale: 3/8" = 1'--0" ti�1� `ll� W E B SE" , GEis DATE NOTES REVISIONS NNQQ VA 11N SS SIGN w _CVC NAL GI E ' IGI�A4°U 01107/2018 Changed FBC Note A + e z e MW, ENGINEERING, INC 902 NE 1 Street Suite #2 Pompano Beach, Florida 33060 Ofc:754-333-0877 W W W. MwEngineering.net General Notes: " Design in accordance with Florida Building Code, 6th Edition (2017). This lifting structure has been designed to withstand wind loads associated with speeds of V (ult) 180 MPH, (3 Second Gust) Exposure V without a boat on the lift per ASCE 7-10 using above ground sign/wall method. The lifting structure including boat has been designed to"withstand wind speeds of V (ult) = 73 MPH in Exposure V. " Boats shall not be stored on lift during high wind events. Do not scale drawings for dimensions. " Licensed Contractor to verify location of existing utilities prior to commencing work. " The Licensed contractor to install and remove all shoring and bracing as required for the proper installation of the work. Licensed Contractor to obtain all permits as necessary from all Local, State, and Federal agencies. " Aluminum: Material 6061 T6 Aluminum, all welds are min. 4" full fillet weld using 5556 filler alloy, all welding must conform to AISC steel construction manual 14th ED as inspected and verified by others. The contractor is responsible to insulate aluminum members from dissimilar metals to prevent electrolysis. " Aluminum members in contact with concrete and wood shall be protected by "Koppers Bituminous Paint" or Polyethylene Tape UHMW (ultra high molecular weight). 11.7 mils (0.30 mm) min. total thickness in accordance -with. current -Florida -Building Code. - " All anchors to be -Hilti Brand or Approved Equal. All bolts shall be hot dipped galvanized or stainless steel & meet the requirements of ASTM A304 with hardened washers and hex nuts. Washers shall be used between wood & bolt head & between wood & nut Where generic fasteners are labeled in details, capacities shall be equal to or greater than Hilt; Kwik Bolt 11 or Red Head thru bolts SAE Grade 5 or better. Embedment depths specified herein are depths into solid substrate and do not included thickness of other finishes. " MW Engineering has no control of the manufacturing, performance or installation of this product. These generic plans were engineered in accordance with accepted engineering practices and data provided by the manufacturer. " Piles shall be driven to refusal and sufficiently penetrated into sand or rock strata to support lift capacity, weight and loads. " Each pile to carry commensurate load I.E. 1/4th lift capacity for 4—post lift (Factor of Safety of 1.5) Allowable minimum compression pile capacity of 5 tons. " The contractor of record shall verify pile type, installation and driving in compliance with FBC 6th ED (2017) " Sub —surface conditions can vary greatly. I ife Copy REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY . v v v � 32 Proposed 4 - Post Boat Lifts NEPTUNE BOAT LIFTS DAME 05.12.2015 4,500 Ib 228 SW 21 Terrace DM"'" un wRr to Fort Lauderdale, Florida 33312 CH BY, wM 24,000 Ib Phone: 954-524-3616 .we N« e...m. 3Ld"9 Fax:954-524-3604 Sheet 1 of 3 s Typical Cross Section A -A Scale: 3/8" = 1'=0" � WEBER Q- o r ,�ag5 o fL (2) J10 Wedge Anchors Into Concrete Piles upport Pile 4" Minimum Embedment WWI) 0.50"0 12" i --4- (2) } 0 Lag Bolts Into Wood Piles 4" Minimum Embedment enter Line of He (Typical) Mounting Bracket Detail REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC un,c 01/07/2018 Nuns Htwslorls = Changed FBC Note I °TN o�N 'S Tv�TM $IGIN ( R'S y41 rTURE o s o ' a = - Q °°•.,, FL o'q;: - �' :� OF ° �� MW, ENGINEERING, INC 902 NE 1 Street Suite #2 Pompano Beach, Florida 33060 Ofc: 754-333-0877 WWW.MwEn ineerin •net Proposed 4 -Post Boat Lifts 4,500 1b t� 24,000 Ib NEPTUNE BOAT LIFTS 228 SW 21 Terrace Fort Lauderdale, Florida 33312 Phone: Fax:954-524-3604 oA,� os.,zzo,s �+ � WRr CMXM er. wM 9 LICENSE 053851 CA 30702 OB Na �w"" Sheet 2 of 3 a Center Center u Typical Cross Section B—B Scale: 3/8' = i'=0" A B C D E F G H J K L M BUNK NOTE Or�Aluminuve'C• Equivaletwith Protectlap�%F Components >s Lift Capacity 4,500 7,000 10,000 13,000 16,000 20,000 24,000 3"x8• Pressure Treated Southern Yellow 3'x10• Pressure Treated Southern Yellow 3"x12" PT Buunk ;'/'+ Pine #1 - See Bunk Note Pine #1 - See Bunk Note SYP #1 i Bunk Bracket Support }'x2"x2' Lifter Beam AA 16•x4.7 AA 18"x6.3 AA 18"x7.0 AA 1 10"x10.3 AA 112"xl1.91 r Sheave Pullet ate }"x4'x5" Angle a ,y �" Cable Si 9 Diameter 7x19 SS 304 7 ' Diameter 7x19 SS 304 (2 Part) 1�" Diameter 7x19 SS 304 (Sialrile`ss Steel ) (1 Part) (3 Part) Piling MourWng Br ck6t J•x3'xl2" Flat Bar CaZier Beam End Plate :•x5• Flat Bar 4"x6" Flat Bar }"x7" Flat Bar }"x5• Flat Bar Drive Shaft Bearing Block 2•x3" Flat Bar - YDrive ShaftJ 1-112" Nominal Diameter Schedule 80 Galvanized Pipe Top Carder -Assembly 2 C-Channels Per Assembly AA CS 5"x2.2 AA CS 6"x2.8 AA CS 7"x3.2 AA CS 8"x4.3 AA CS 8"x5.79 Motor siz" (2)J Hp (2) 1 HP (2) j HP _(2) 1 HP (2) 1 HP (2) 1 HP (2) 1 HP (Horse PovlerNoltage) 240V/20A 1 240V/20A 240V/20A ' 240V120A 240V/20A 240V/20A 240V/20A Top Carrier Connector tx3'x12" Flat Bar Guide Post Socket 2" Nominal Diameter Schedule 80 Aluminum Pipe � Motor size Horse Power, Voltage and Amperage are based on the Standard Speed Direct Drive Lift ,r +a REVIEWED FOR wS BF��c'�: CODE COMPLIANCE ST. LUCIE COUNTY BOCC AK:w- DATE NOTES REVISIONS = : No v Esser gD WITH ;oRl N$L iQNAruRE MW, ENGINEERING, INC Proposed 4 - Post Boat Lifts NEPTUNE BOAT LIFTS sue: 32 DATE 05.12.2015 01/07/2018 Changed FBC Note p0 •. • FL• •: SS I � -0P 902 NE 1 Street Suite #2 Pompano Beach, Florida 33060 4,500 Ib t0 to 228 SW 21 Terrace Fort Lauderdale, Florida 33312 WWN �: wRT Ceram BY. wM JOB Nm eevator 39.dp Ofc: 754-333-0877 VWWV.MwEngineering.r 24, Ib Phone: 954-524-3616 Fax: 954-524-3604 1 Lt1! E WEBER, P.E Sheet 3 3 LICENSE #53895 1 CA 30702 of r MOD Nil File COPY