HomeMy WebLinkAboutFL Owens Corning Peal N Stick Shingle ONLY.pdfSCIS Home Log In ! User Registration Hot Topics Submit Surcharge Stats & Fads : Publications Contact Us BCIS Site Map links Search
byr
Product Approval
- USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL9777-R11
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE -74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL9777 R11 COI OCR14002.8a 2017 FBC Evaluation Report Weatherlock
Non-HVHZ.pdf
Standard
Year
ASTM D 1970
2015
ASTM D 226
2009
ASTM G 155
2005
TAS 103
1995
UL 1897
2012
Product Approval Method Method 1 Option D
Date Submitted
10/11/2017
Date Validated
10/11/2017
Date Pending FBC Approval
10/17/2017
Date Approved
12/12/2017
p Model, Number or Name Description
9777.1 vu Weatherlock G -- Weatherproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9777 Ell II OCR14007 8a 2017 FBC
Approved for use outside HVHZ: Yes Weatherlock Non-HVHZ.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL9777 RII AE OCR 14002 8a 2017 FB(
Weatherlock Non-HVHZ.pdf
9777.2 Weatherlock G (High Tear) Weatherproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9777 Ri i II OCR14002.8a 2017 FBCEvalu t' e�rt
Approved for use outside HVHZ: Yes Weatherlock Non-HVHZ.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest PE -74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL9777 R11 AE OCR14002 8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ.pdf
Created by Independent Third Party: Yes
9777.3 Weatherlock MAT j Waterproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL9777 R11 II OCR14002.8b 2017 FBC Evaluation Repo
Approved for use outside HVHZ: No Weatherlock HVHZ.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL9777 R11 AE OCR14002 8b 2017 FBC Evaluation Report
Weatherlock HVHZ.pdf
Created by Independent Third Party: Yes
9777.4 Weatherlock MAT Waterproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9777 R11 II OCR 14002 8a 2017 FBC Evaluation Rept
Approved for use outside HVHZ: Yes Weatherlock Non-HVHZ.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL9777 R11 AE OCR14002 8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ.pdf
Created by Independent Third Party: Yes
9777.5 Weatherlock Metal Weatherproofing Underlayment
Limits of Use _ Installation Instructions
Approved for use in HVHZ: No FL9777 R11 II OCR14002 8a 2017 FBC Evaluation Report
Approved for use outside HVHZ: Yes Weatherlock Non-HVHZ.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest PE -74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL9777 R11 AE OCR14002 8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ.pdf
Created by Independent Third Party: Yes
9777.6 Weatherlock Metal Weatherproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL9777 R11_11 OCR14002 8b 2017 FBC Evaluation Report
Approved for use outside HVHZ: No Weatherlock HVHZ.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest PE -74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other. See evaluation report for limits of use. Evaluation Reports
9777,7 WeatherLock Specialty Tile & Metal
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +0/-142.5
other: See evaluation report for limits of use.
FL9777 R11 AE OCR14002 8b 2017 FBC Evaluation Report
Weatherlock HVHZ.p—df
Created by Independent Third Party: Yes �.
Weatherproofing Underlayment
Installation Instructions
FL9777 R11 II OCR14002 8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ.pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 R11 AE OCR14002.8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ.pdf
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stane Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: AccessibilityStatement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provideemail
ses are
provide the Department with anmay be used for aemail addressowh whth ich can be made available rto the publics To determine f you are aic record. If licensee under Chapter 455, F.Sdo not wish to supply a n l address, please
please click here .
Product Approval Accepts:
® EE
Credit Card
Safe
f.r.-Certificate of Authorization No. 29824
REEK
17520 Edinburgh Drive
Tampa, FL 33647
(813} 480-3421
TECHNICAL SERVICES, LLC
EVALUATION REPORT FLORIDA BUILDING CODE, C EDITION (2017)
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11, 2017
1 Owens Corning Parkway
Toledo, OH 43657
(800) 438-7465
www owenscorninfl.com
Manufacturing Location: Brentwood, NH
Houston, TX
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category: Roofing
Subcategory: Undedayments
Code Sections: 1504.3.1, 1507.1.1
Properties: Physical properties
REFERENCES
gn&
Report No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
NEI -039-02-01
ASTM D 1970
2015
2015
PRI Construction Materials Technologies (TS75878)
NEI -042-02-01 REV2
ASTM D 1970
1995
PRI Construction Materials Technologies (TST5878)
NEI -045-02-01
NEI
TAS 103
ASTM G155
20058
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
-045-02-01
NEI -053-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
NEI -053-02-01
ASTM G 155
2005a
2015
PRI Construction Materials Technologies (TST5878)
NEI -093-02-02
OCF-213-02-01
ASTM D 1970
ASTM D 1623
2009
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
OCF-237-02-01
UL 1897
2012
PRI Construction Materials Technologies (TST5878)
OCF-252-02-01
ASTM D 4798
2001
2015
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
OCF-252-02-01
OCF-253-02-02
ASTM 0 1970
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-272-02-01
TA3103
C AC 8'
1995
2012
PRI Construction Materials Technologies (TST5878)
OCF-296-02-02
-ES
ICC ES AC 48
2012
PRI Construction Materials Technologies (TST5878)
OCF-297-02-01.1
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-318-02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-320.02-01
TAS 103
1995
2005e
PRI Construction Materials Technologies (TST5878)
OCF-320-02-01
OCF-321-02-01
ASTM G 155
ASTM D 1623
2009
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
OCF-322-02-01
UL 1897
2012
PRI Construction Materials Technologies (TST5878)
OCF-355-02-01
UL 1897
2012
'Determined to be equivalent to ASTM D 226-09, Type I and 11
vvr%1 RVv.. va -
This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shalt notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GREEK
TECHNICAL SERviCEs, LLC
PRODUCT
k9) 0
NH)
WeatherLocko Mat
(Brentwood, NH or
Houston, TX)
WeatherLockO Metal!
(Brentwood, NH)
WeatherLockO
Specialty Tile & Metal
(Brentwood, NH or
Houston, 7X)
WeatherLockO G (High
Tear)
(Houston, TX)
OCR94002 8a
OF USE
ROOFINGOWENS CORNING
bleat erLnckO Self -58811 g lee & Water Barriers
WeatherLock® G is an ASTM DEvenngs.
adhesive u eflayment constructed from SBS
modified asphalt, a fiberglass rcement a surfaced with granules. The
product is supplied in 2 -sq. rolls al dimensi s of 3 -ft x 66.7 -ft.
WeatherLock(D G is permitted prescribed in FBC Section 1507.1.1 for
mechanlcaliv attacked geeExposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLock@ Mat is an ASTM D 1970 self-adhesive underlayment constructed from
forcement, The
sq. rollBS s wt with nominalfied twith a dimensions of 3 -ft 33.3 -ft glass mat and 2 sq. rolls with nominal roduct is supplied
mensions
of 3 -ft x 66.7 -ft.
WeatherLock@ Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on to roof deck shall be limited to a
maximum 30 days.
WeatherLock@ Metal is an ASTM D 1970 self-adhesive underlayment constructed from
SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq. roils with nominal dimensions of 3 -ft x 66.7 -ft.
WeatherLockd in FBC
on
07.1.1
mechanically attached lsroof coveringsto . Exposurused ase on heeoof deck shall bellimited to a
maximum 90 days.
WeaherLock® Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment
constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric.
The product is supplied in 2.14 sq, rolls with nominal dimensions of 3 -ft x 71.3 -Ft.
Weatherl-ockS Specialty Tile & Metal is permitted to be used as prescribed in FBC
Section 1507.1.1. WeatherLockO Specialty Tile & Metal is permitted to be used with
adhered clay or concrete the roofing using either ICP Adhesives Polyset AH -160 (ICP
Adhesives and Sealants, inc,) or TILE BOND'"' Roof Tile Adhesive (The Dow Chemical
Company). Exposure on the roof deck shall be limited to a maximum 90 days.
The maximum roof slope shall be 6:12 when used with clay or concrete the installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
WeatherLockO G (High Tear) is a self -adhered, underlayment used as an alternative to
ASTM D 226, Type I or Type II roofing felt and ASTM D 1970 self -adhering polymer
modified bitumen underlayment. The underlayment is composed of SBS modified
asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The
product is supplied with a nominal thickness of 50 mils in 1.96 -sq rolls with nominal
dimensions of 3 -ft x 65 -ft.
Weabe
sed
escribed in FBC
on
5071.11 1 for mechanically attachederoofted coverigs.uExposureron the roof deck hall be
limited to a maximum 30 days.
FL9777-R11
2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. 7ne manuracrurer snan nUu,p
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
V.y,. CREEK
TECHNICAL. SERVICES, LLC
PRODUCT APPLICATION
HALT LLCW
eathe&ock® Self.S a! ng Ice & Wat r Barriers
Min. Roof Slope: 2:12 in accordance with the FBC
Application: Ail underlayments shall be installed in accordance with the FBC-
Deck substrates shall be clean, dry, and free from any irregularitles and debris. All
fasteners In the deck shall be checked for protrusion and corrected prior to underlayment
application. Prior to beginning installation, the undedayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The undedayment shall be installed with the release backer removed and pressed firmly
into place to ensure complete contact with the deck. The undedayment shall be installed
with the roll length parallel to the Gave, starting at the save, and with minimum 3" side
laps and minimum 6" end laps staggered min. 6 -ft -from preceding course. Additionally, if
applying WeetherLock® Specialty Tile & Metal, end laps shall be primed with ASTM D
41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width
of the lap.
It is permissible to back nail the underlayment 12 -inches on -center as needed (nails shall
be installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment). Additionally, WeatherLock® Specialty Tile & Metal shall be back nailed
when installed on roof slopes greater than 3:12.
Min. Application 40°F; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
WIND RESISTANCE
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9.
i lyderlayment Svstem �l01 WeatherLock Stsecialty Tile &_ Metal Only
Roof peck: Min. 15/32 -inch CDA plywood attached to wood supports spaced a maximum 24" o.c.
WeatherLock(10 specialty Tile & Metal shall be applied in accordance with
manufacturer's installation instructions to the fastened deck and backnailed along the
selvage with minimum 12ga., 1 -114 -inch galvanized ring shank roofing nails through
underlayment shall be rolled l- with
ach 0 On caps spaced mimum 511b steel rroller2immediatelygfollowiiied
i g
application.
Underlayment:
Maximum Design -142,5 psf
Pressure:
O 2.8a
FL9777-Ri l Page 3 of 4
Thisis evaluation report is provided far State of Florida product approval under Rule 61G2Q-3. The manufacturer shall notify CRE
EK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SE;RviCES, LLC
GENERAL LIMITATIONS
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLoeW Self.Sealing ice & Water Barriers
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The undedayment may be used as described in other current FBC product approval documents.
6) Design wind load pressures shall be determined for components and cladding in accordance with FBC
1609.
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a given undedayment shall meet or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 614320-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code a Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
,Its It r ter iti��*ori
No 74021
4 . • r
STATE OF • . iIJ
,►�� 55,E •......•��1��.
0 tI A
h,100�l %<<�,�
CERTIFICATION OF INDEPENDENCE
2017.10.11
09:06:29
aqW W W krao..v a. r..w
04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREED Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, at controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
OCR14002.80 FL9777-R11 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shalt notify CREEK
Teces
d.
This hnical Services, LLC of evaluation report does no express norproduct nimply warror anty, installation, assurrence commend d use, oro hhout the err product on for Bch this report attributes thatiare not
specifically addressed herein.