Loading...
HomeMy WebLinkAboutExtreme Metal FL17022_R7_II_FL 17022.1_5 V CRIMP1/13/2020 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEqvOQveeg%3d%3d 1/3 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL17022-R7 Application Type Revision Code Version 2017 Application Status Approved Comments 08/18/2017v. date reapply 08/21/17 Archived Product Manufacturer Extreme Metal Fabricators, LLC Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 flvalidation@yahoo.com Authorized Signature Richard McKuhen flvalidation@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 richard@emfab.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report LOCKE BOWDEN Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest, P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL17022_R7_COI_FL 17022.1_5 V CRIMP_ssr.pdf Referenced Standard and Year (of Standard)Standard Year TAS 125 2003 UL 1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code 1/13/2020 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEqvOQveeg%3d%3d 2/3 Product Approval Method Method 1 Option D Date Submitted 08/18/2017 Date Validated 08/25/2017 Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 Summary of Products FL #Model, Number or Name Description 17022.1 1 - "5V Crimp" (R6)26 Gauge steel, 3/8" rib height, 24” wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-Table A Other: Refer to evaluation report for conditions. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer’s installation instructions. Installation Instructions FL17022_R7_II_FL 17022.1_5 V CRIMP_ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022_R7_AE_FL 17022.1_5 V CRIMP_ssr.pdf Created by Independent Third Party: Yes 17022.2 2 - "5V Crimp" (R6)0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-Table A Other: Refer to evaluation report for conditions.Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer’s installation instructions. Installation Instructions FL17022_R7_II_FL 17022.2_5 V CRIMP 0.032 ALUM_ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022_R7_AE_FL 17022.2_5 V CRIMP 0.032 ALUM_ssr.pdf Created by Independent Third Party: Yes 17022.3 3 - "1.5" Mechanical Seam" (R5)1.5” rib height, 16” wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer’s installation instructions. Installation Instructions FL17022_R7_II_FL 17022.3_1.5 MECHANICAL seam_24ga_ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022_R7_AE_FL 17022.3_1.5 MECHANICAL seam_24ga_ssr.pdf Created by Independent Third Party: Yes 17022.4 4 - "1.5" Mechanical Seam" (R5)1.5” rib height, 16” wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Wood Deck with clips and fasteners. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer’s installation instructions. Installation Instructions FL17022_R7_II_FL 17022.4 MECHANCIAL SEAM ALUMINUM_ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022_R7_AE_FL 17022.4 MECHANCIAL SEAM ALUMINUM_ssr.pdf Created by Independent Third Party: Yes 17022.5 5 - "1 in. Nail Strip" (R5)1” rib height, 16” wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer’s installation instructions. Installation Instructions FL17022_R7_II_FL 17022.5_1.0 NAILSTRIP_ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022_R7_AE_FL 17022.5_1.0 NAILSTRIP_ssr.pdf Created by Independent Third Party: Yes 1/13/2020 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEqvOQveeg%3d%3d 3/3 17022.6 6 - "1 in. Nail Strip" (R5)1” rib height, 16” wide, 0.032" aluminum, standing seam roof panel mechanically attached to attached to 15/32" plywood or Wood Deck with fasteners, Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer’s installation instructions. Installation Instructions FL17022_R7_II_FL 17022.6 _1.0 NAIL STRIP_0.032 ALUM_ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022_R7_AE_FL 17022.6 _1.0 NAIL STRIP_0.032 ALUM_ssr.pdf Created by Independent Third Party: Yes 17022.7 7 - "1.5 in. Nail Strip" (R5)1.5” rib height, 19” wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer’s installation instructions. Installation Instructions FL17022_R7_II_FL 17022.7_1.5 Nail Strip 26GA_ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022_R7_AE_FL 17022.7_1.5 Nail Strip 26GA_ssr.pdf Created by Independent Third Party: Yes 17022.8 8 - "EMAX Rib" (R5)29 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer’s installation instructions. Installation Instructions FL17022_R7_II_FL 177022.8 EMAX Rib_ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022_R7_AE_FL 177022.8 EMAX Rib_ssr.pdf Created by Independent Third Party: Yes 17022.9 9 - " PBR MAX" (R5)26 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer’s installation instructions. Installation Instructions FL17022_R7_II_FL 17022.9 PBR RIB_ ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022_R7_AE_FL 17022.9 PBR RIB_ ssr.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Product Report Manufacturer: Extreme Metal Fabricators, LLC. 2160 SW Poma Drive Palm City, FL 34990 Compliant with Florida Building Code 2017 (6th ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood Deck w/ min. 0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" 772 872-8034 Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1 (Method 1 Attachment): #9 x 1-1/2" Hex-Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex-Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. Install Details: Table A Allowable Lo ads METHOD 1 METHOD2 METHOD 3 METHOD4 DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF ROW SPACING 16" o.c. 16" o.c. 8" o.c. 6" o.c. FASTENER SPACING (ALONG Panel width) 12" o.c. 12" o.c. 12" o.c. 12" o.c. FASTENER SIZE #9 #10 #10 #10 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 152 7 UL 580-06 & 1897-041 TAS 125-0 3 05/02/14 Test Report D05893.0l-450-18 Test Report F3366.0l-450-18 Test Report D05893.02-450-18 12/18/15 0 7/22/14 ··'''""''''·' ,, ,,'�x.. 0. BO �V: ,,., Locke Bowden, P.E. does not have, not will acquire a finan cial in��l�-eili'; fqmJla11.V, �;�facturing or distributing products .. .. \,� ., l .:i',t:' • / / ,,. under this evaluation. :-'v • � • ' �Locke Bowden, P.E. is not owned, operated, or controlled by ai, co�parl'lprrnithJfKtur;,, ord.istributing products under this report. ;�,1. (Mj·� :: :f"': :•:: �,... .? � � /'·. . s" · :,"-i�ilo -;,,C!<-;_ • .;:-l OH\0 � • • ·�J, "',, ,:s ,· •.•• • .... �{) .. · l,,: 10NAL t-\ ,.;,•l:itt::. 11\\\\•' *EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-12.*Design pressure margin of safety 2:1 See Fastener attachment specifications above Fasten r #9 × 1-1/2" Min. or #10 × 1-1/2" Min. per Table "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Width Refer to Table "A" for Spacing Along Panel Length Nominal 12" o.c. Nominal 12" o.c. Panel Overlap Deck- 15/32" or greater :Plywood, or -Wood plank Fasteners - #9 × 1-1/2" Min. or #10 × 1-1/2" Min. per Table "A" for Row Spacing and Design Pressures Hex Washer Head Wood Screws Re f e r t o T a b l e " A " Deck: - 15/32" or greater Plywood, or - Wood plank 5-V Crimp Roof Panel FL17022.1 5V Crimp (26GA Steel), 24" Wide Roof Panel - Details Limitations: 1.Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed. 2.Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer’s installation reference. 3.Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D 4.Engineering analysis for “project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5.Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6.Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7.This report does not imply warranty, installation, recommended product use outside of this report.