Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 RECEIVED AN 21 2,,92,,9 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: GARAFALO RESIDENCE Builder Name: Street: 10751 S. OCEAN DRIVE A13 Permit Office: ST LUCIE COUNTY City, State, Zip: JENSEN BEACH , FL, Permit Number: Owner. Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (3160.0 sgft.) Insulation Area ' 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 2712.00 ft' b. Frame - Wood, Adjacent R=11.0 448.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft. 4. Number of Bedrooms 3 d. NIA R= ft. 10. Ceiling Types (3291.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 3291.00 ft' 6. Conditioned floor area above grade (f 2) 3291 b. N/A R= ft' Conditioned floor area below grade (W) 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(605.3 sqft.) Description Area a. Sup: Attic, Rat: Attic, AH: Garage 6 125 a. U-Factor: SgI, U=0.29 373.33 ft' b. Sup: Attic, Ret: Attic, AH: LAUNDRY 6 150 SHGC: SHGC=0.21 b. U-Factor: SgI, U=0.26 180.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.23 a. Central Unit 24.0 SEER:16.00 b. Central Unit 35.2 SEER:16.00 c. U-Factor: SgI, U=0.31 40.00 ft' SHGC: SHGC=0.19 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 12.00 fN a. Electric Strip Heat 17.0 COPA.00 SHGC: other (see details) b. Electric Strip Heat 27.0 COPA.00 Area Weighted Average Overhang Depth: 0.833 ft. Area Weighted Average SHGC: 0.215 14. Hot water systems a. Electric Cap: 50 gallons S. Floor Types (3291.0 sqft.) Insulation Area EF: 0.980 a. Raised Floor R=30.0 1995.00 ft' b. Conservation features b. Slab -On -Grade Edge Insulation R=0.0 1296.00 ft' None c. N/A R= ft' 15. Credits None Glass/FloorArea: 0.184 Total Proposed Modified Loads: 106.68 PASS Total Baseline Loads: 106.73 1 hereby certify that the plans and specifications covered by Review of the plans and STg7� this calculation are in compliance with the Florida Energy specifications covered by this 0411JE S, , a = , Off, Code. calculation indicates compliance with the Florida Energy Code. :. , .. F rmr,.. ?••:, ��i�°�;;m�„ O PREPA43Y: Before construction is completed w o DATE: II SZ,� thisbuildingwill beinspected for compliance with Section 553.908 c7 > I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. COp WE ^� OWNER/AGENT- 1 1 I/ BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 122020 11:36 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: GARAFALO RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 3291 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook Builder Name: Rotate Angle: 0 Street: 10751 S. OCEAN DRIV Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: JENSEN BEACH , Family Type: Single-family FL , New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.6 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1ST FLOOR 1296 12052.8 2 AHU 2ND FLOOR 1995 15960 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 DINING 272 2529.6 No 0 1 Yes Yes Yes 2 GREAT ROOM 320 2976 No 0 1 Yes Yes Yes 3 PANTRY 75 697.5 No 0 1 Yes Yes Yes 4 KITCHEN 395 3673.5 Yes 0 1 Yes Yes Yes 5 POWDER RM 30 279 No 0 1 No Yes Yes 6 STAIR STORAGE 24 223.2 No 0 1 Yes Yes Yes 7 FOYER 150 1395 No 0 1 Yes Yes Yes 8 ELEVATOR 30 279 No 0 1 No Yes Yes 9 BEDROOM 3 150 1200 No 0 1 1 Yes Yes Yes 10 BATH 2 81 648 No 0 1 Yes Yes Yes 11 M BATH 139 1112 No 0 1 Yes Yes Yes 12 M TOILET 28 224 No 0 1 No Yes Yes 13 M WIC 100 800 No 0 1 No Yes Yes 14 ELEVATOR UP 30 240 No 0 1 No Yes Yes 15 LAUNDRY 81 648 No 0 1 No Yes Yes 16 LOFT 313 2504 No 0 1 Yes Yes Yes 17 CLST 3 24 192 No 0 1 Yes Yes Yes 18 BEDROOM 2 154 1232 No 0 1 1 Yes Yes Yes 19 CLST 2 18 144 No 0 1 Yes Yes Yes 20 DEN 110 880 No 0 1 Yes Yes Yes 21 WIC DEN 24 192 No 0 1 Yes Yes Yes 10202011:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 22 STAIRS UP 44 352 No 0 1 Yes Yes Yes 23 M SITTING AREA 176 1408 No 0 1 Yes Yes Yes 24 MASTER BEDROO 523 4184 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio DINING 47 ft 0 272 ft' — 1 0 0 2SIab-On-Grade Edge Insulatio GREAT ROOM 36ft 0 320 ft' _ 1 0 0 3SIab-On-Grade Edge Insulatio PANTRY 5 ft 0 75 ft' _ 1 0 0 4SIab-On-Grade Edge Insulatio KITCHEN 15 ft 0 395 ft' — 1 0 0 5SIab-On-Grade Edge Insulatio POWDER RM 1ft 0 30 ft' — 1 0 0 6SIab-On-Grade Edge Insulatio STAIR STORAG 6 ft 0 24 ft' — 1 0 0 7 Slab -On -Grade Edge Insulatio FOYER 17 ft 0 150 ft' — 1 0 0 8SIab-On-Grade Edge Insulatio ELEVATOR 1 ft 0 30 ft' — 1 0 0 9 Raised Floor BEDROOM 3 _ — 150 ft' 30 1 0 0 1CRaised Floor BATH 2 — — 81 ft' 30 1 0 0 1lRalsed Floor M BATH — — 139 ft' 30 1 0 0 12Raised Floor M TOILET — _ 28 ft' 30 1 0 0 13Raised Floor M WIC — _ 100 ft' 30 1 0 0 14Ralsed Floor ELEVATOR UP — _ 30 ft' 30 1 0 0 15Raised Floor LAUNDRY — _ 81 ft' 30 1 0 0 16Raised Floor LOFT _ — 313 ft' 30 1 0 0 17Raised Floor CLST 3 _ _ 24 ft' 30 1 0 0 18Raised Floor BEDROOM 2 — — 154 ft' 30 1 0 0 lgRaised Floor CLST 2 — — 18 W 30 1 0 0 20Raised Floor DEN — _ 110 ft' 30 1 0 0 21Ralsed Floor WIC DEN — — 24 ft' 30 1 0 0 22Raised Floor STAIRS UP _ _ 44 ft' 30 1 0 0 23Raised Floor M SITTING ARE — — 176 ft' 30 1 0 0 24Raised Floor MASTER BEDRO — — 523 ft' 30 1 0 0 12/202011:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck, Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 3468 ft2 0 ft2 Light N 0.2 No 0.9 No 20 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 In) Area RBS IRCC 1 Full attic Unvented 0 3291 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) DINING 0 Blown 272 ft2 0.1 Wood 2 Under Attic (Unvented) GREAT ROOM 0 Blown 320 ft2 0.1 Wood 3 Under Attic (Unvented) PANTRY 0 Blown 75 W 0.1 Wood 4 Under Attic (Unvented) KITCHEN 0 Blown 395 W 0.1 Wood _ 5 Under Attic (Unvented) POWDER RM 0 Blown 30 ft- 0.1 Wood 6 Under Attic (Unvented) STAIR STORAG 0 Blown 24 ft2 0.1 Wood 7 Under Attic (Unvented) FOYER 0 Blown 150 ft2 0.1 Wood 8 Under Attic (Unvented) ELEVATOR 0 Blown 30 ft2 0.1 Wood 9 Under Attic (Unvented) BEDROOM 3 0 Blown 150 ft2 0.1 Wood _ 10 Under Attic (Unvented) BATH 2 0 Blown 81 ft- 0.1 Wood _ 11 Under Attic (Unvented) M BATH 0 Blown 139 ft2 0.1 Wood 12 Under Attic (Unvented) MTOILET 0 Blown 28 ft2 0.1 Wood 13 Under Attic (Unvented) M WIC 0 Blown 100 ft2 0.1 Wood 14 Under Attic (Unvented) ELEVATOR UP 0 Blown 30 ft2 0.1 Wood 15 Under Attic (Unvented) LAUNDRY 0 Blown 81 ft' 0.1 Wood 16 Under Attic (Unvented) LOFT 0 Blown 313 ft2 0.1 Wood _ 17 Under Attic (Unvented) CLST 3 0 Blown 24 ft2 0.1 Wood _ 18 Under Attic (Unvented) BEDROOM 2 0 Blown 154 ft2 0.1 Wood _ 19 Under Attic (Unvented) CLST 2 0 Blown 18 ft2 0.1 Wood 20 Under Attic (Unvented) DEN 0 Blown 110 ft2 0.1 Wood 21 Under Attic (Unvented) WIC DEN 0 Blown 24 ft' 0.1 Wood _ 22 Under Attic (Unvented) STAIRS UP 0 Blown 44 ft2 0.1 Wood _ 23 Under Attic (Unvented) M SITTING ARE 0 Blown 176 ft2 0.1 Wood 24 Under Attic (Unvented) MASTER BEDRO 0 Blown 523 tt2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 E Exterior Concrete Block - Int Insul DINING 4.1 11 0 9 4 102.7 ft2 0 0 0.2 0 _ 2 S Exterior Concrete Block - Int Insul DINING 4.1 25 0 9 4 233.3 ft2 0 0 0.2 0 3 W Exterior Concrete Block - Int Insul DINING 4.1 11 0 9 4 102.7 ft2 0 0 0.2 0 _ 4 E Exterior Concrete Block - Int Ins01REAT ROO 4.1 20 0 9 4 186.7 ft2 0 0 0.2 0 5 S Exterior Concrete Block - Int Ins(AREAT ROO 4.1 16 0 9 4 149.3 ft2 0 0 0.2 0 10202011:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space -6 W Exterior Concrete Block - Int Insul PANTRY 4.1 5 0 9 4 46.7 ft- 0 0 0.2 0 _ 7 N Garage Frame - Wood PANTRY 11 15 0 9 4 140.0 ft' 0 0.1 0.2 0 _ 8 W Exterior Concrete Stock - Int InsulKITCHEN 4.1 15 0 9 4 140.0 ft' 0 0 0.2 0 _ 9 N Garage Frame - Wood KITCHEN 11 4 0 9 4 37.3 ft- 0 0.1 0.2 0 _ 10 N Garage Frame - Wood POWDER R 11 5 0 9 4 46.7 ft- 0 0.1 0.2 0 _ 11 E Exterior Concrete Block - Int InsSTAIR STOR 4.1 6 0 9 4 56.0 ft' 0 0 0.2 0 12 N Exterior Concrete Block - Int Insul FOYER 4.1 11 0 9 4 102.7 ft' 0 0 0.2 0 13 E Exterior Concrete Block - Int Insul FOYER 4.1 6 0 9 4 56.0 ft' 0 0 0.2 0 14 W Garage Frame - Wood FOYER 11 13 0 9 4 121.3 ft' 0 0.1 0.2 0 _ 15 N Garage Frame - Wood ELEVATOR 11 6 0 9 4 56.0 fF 0 0.1 0.2 0 _ 16 W Garage Frame - Wood ELEVATOR 11 5 0 9 4 46.7 ft' 0 0.1 0.2 0 _ 17 N Exterior Concrete Block - Int InsBEDROOM 3 4.1 14 0 8 0 112.0 ft' 0 0 0.2 0 _ 18 W Exterior Concrete Block - Int InsSEDROOM 3 4.1 10 0 8 0 80.0 ft' 0 0 0.2 0 _ 19 W Exterior Concrete Black - Int Insul BATH 2 4.1 9 0 8 0 72.0 fP 0 0 0.2 0 20 W Exterior Concrete Block - Int Insul M BATH 4.1 13 0 8 0 104.0 ft' 0 0 0.2 0 21 E Exterior Concrete Block - Int Insul LOFT 4.1 11 0 8 0 88.0 ft- 0 0 0.2 0 _ 22 N Exterior Concrete Block - Int Insul CLST 3 4.1 2 0 8 0 16.0 ft' 0 0 0.2 0 23 N Exterior Concrete Block- Int InsBREDROOM 2 4.1 11 0 8 0 SB.0 fF 0 0 0.2 0 24 W Exterior Concrete Black - Int lmBEDROOM 2 4.1 2 0 8 0 16.0 1? 0 0 0.2 0 25 N Exterior Concrete Block - Int Insul CLST 2 4.1 3 0 8 0 24.0 fP 0 0 0.2 0 26 E Exterior Concrete Block - Int Insul CLST 2 4.1 6 0 8 0 48.0 fI2 0 0 0.2 0 27 N Exterior Concrete Block - Int Insul DEN 4.1 7 0 8 0 56.0 W 0 0 0.2 0 28 N Exterior Concrete Block- Int InsulWIC DEN 4.1 4 0 8 0 32.0 ft' 0 0 0.2 0 29 E Exterior Concrete Block - Int lnsulWIC DEN 4.1 6 0 8 0 48.0 fR 0 0 0.2 0 30 E Exterior Concrete Block - Int InsL6TAIRS UP 4.1 11 0 8 0 88.0 ft' 0 0 0.2 0 31 E Exterior Concrete Block - Int InsM SITTING A 4.1 11 0 8 0 88.0 ft' 0 0 0.2 0 32 S Exterior Concrete Block- Int InsM SITTING A 4.1 16 0 8 0 128.0 ft' 0 0 0.2 0 _ 33 E Exterior Concrete Block - Int InsNASTER BE 4.1 10 0 8 0 80.0 ft' 0 0 0.2 0 34 S Exterior Concrete Block - Int Ins0JASTER BE 4.1 25 0 8 0 200.0 ft- 0 0 0.2 0 35 W Exterior Concrete Block - Int Ins61ASTER BE 4.1 21 0 8 0 165.0 fN 0 0 0.2 0 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Vinyl Low-E Single Yes 0.29 0.21 N 40.0 ft' 0 It 10 in 0 ft 0 in None None 2 S 2 Vinyl Low-E Single Yes 0.26 0.23 N 40.0 ft' 0 It 10 in 10 ft 0 in None None 3 S 2 Vinyl Low-E Single Yes 0.29 0.21 N 40.0 ft' 0 it 10 in 10 ft 0 in None None 4 W 3 Vinyl Low-E Single Yes 0.26 0.23 N 20.0 ft' 0 ft 10 In 10 ft 0 in None None 5 E 4 Vinyl Low-E Single Yes 0.26 0.23 N 40.0 W 0 it 10 in 10 It 0 in None None 6 S 5 Vinyl Low-E Single Yes 0.29 0.21 N 96.0 ft- 0 it 10 in 0 ft 0 in None None _ 7 N 12 Vinyl Low-E Single Yes 0.24 0,23 N 12.0 ft' 0 It 10 in 0 It 0 in None None _ 8 N 12 Vinyl Low-E Single Yes 0.29 0.21 N 24.0 ft' 0 ft 10 in 0 ft 0 in None None 9 N 17 Vinyl Low-E Single Yes 0.29 0.21 N 15.0 fP 0 ft 10 in 0 ft 6 in None None 12/202011:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC Sth Edition (2017) Compliant Software Page 5 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 10 W 18 Vinyl Low-E Single Yes 0.29 0.21 N 15.0 fN Oft 10 in 0 ft 6 in None None 11 W 19 Vinyl Low-E Single Yes 0.29 0.21 N 4.0 ft' 0 It 10 in 0 It 6In None None 12 W 20 Vinyl Low-E Single Yes 0.29 0.21 N 4.0 ft' 0 ft 10 in 0 It 6 in None None 13 E 21 Vinyl Low-E Single Yes 0.29 0.21 N 15.0 ft' 0 It 10 in 0 It 6 in None None _ 14 N 23 Vinyl Low-E Single Yes 0.29 0.21 N 15.0 ft' 0 ft 10 In 0 It 6In None None _ 15 N 27 Vinyl Low-E Single Yes 0.29 0.21 N 12.0 ft' 0 It 10 in 0 ft 6 in None None _ 15 E 31 Vinyl Low-E Single Yes 0.26 0.23 N 20.0 ft- 0 It 10 in 0 It 6 in None None _ 17 S 32 Vinyl Low-E Single Yes 0.29 0.21 N 53.3 ft- 0 It 10 in 0It 0 in None None _ 18 E 33 Vinyl Low-E Single Yes 0.31 0.19 N 40.0 ft' 0 It 10 in Oft 0 in None None _ 19 S 34 Vinyl Low-E Single Yes 0.26 0.23 N 40.0 ft- 0 It 10 in 0 It 6 in None None _ 20 S 34 Vinyl Low-E Single Yes 0.29 0.21 N 40.0 ft' 0 R 10 in 0 It 6 in None None 21 W 35 Vinyl Low-E Single Yes 0.26 0.23 N 20.0 ft' 0 It 10 in 0 It 6In None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 780 ft- 780 ft' 53 It 9 It 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000379 3268.2 179.42 337.42 .1345 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts _ 1 Electric Strip Heat/ None COP:1 17 kBtuthr 1 sys#1 2 Electric Strip Heat/ None COPA 27 kBtwhr 2 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 24 kBtumr 720 cfm 0.8 1 sys#1 2 Central Unit/ Split Singl SEER: 16 35.2 kBtu/hr 1056 cfm 0.8 2 sys#2 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.96 50 gal 62.3 gal 120 deg None 121202011:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Softvrare Page 6 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS — Supply — — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 125 ft' Attic 13 ft' Default Leakage Garage (Default) (Default) 1 1 2 Attic 6 150 ft' Attic 15 ft' Default Leakage LAUNDRY (Default) (Default) 2 2 TEMPERATURES Programable[[ Ceiling Fans: jjThermosta[[t:]]N Heating [X] Jan [X] Feb [[ jj [X] Mar E ] ] Apr E ] May [XJ [X] [ ] Jun [ ] Jul [X] [ ] Aug [X] [ ] Sep [[X]] NovNov [[X]] Dec Venting [[ ]] Jan [[ 11 Feb [[XX]] Mar [X] [ ] I 1 Jun I 1 Jul I 1 Aug (]Sep l�l Oct [X] [ ] DDec ec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. Oft' Oft 0.3 DINING Default(8 Ibs/sq.ft. ft' ft 0.3 GREAT ROOM Default(8 lbs/sq.ft. ft' ft 0.3 PANTRY Defauft(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 Ibsfsq.ft. ft' ft 0.3 POWDER RM Default(8 Ibs/sq.ft. ft' ft 0.3 STAIR STORAGE Defauft(8 lbsfsq.ft. ft' ft 0.3 FOYER Defauft(8 lbs/sq.ft. ft' ft 0.3 ELEVATOR Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft' ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft' ft 0.3 M BATH Defauft(8 Ibs/sq.ft. ft' ft 0.3 M TOILET Defauft(8 lbs/sq.ft. W ft 0.3 MWIC Default(8 Ibs/sq.ft. ft' ft 0.3 ELEVATOR UP Default(8 lbs/sq.ft. ft' ft 0.3 LAUNDRY Defauft(8 lbs/sq.ft. ft' ft 0.3 LOFT Default(8 Ibs/sq.ft. ft' ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(S Ibs/sq.ft. ft' ft 0.3 CLST 2 10202011:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Defauft(8 lbs/sq.ft. ft' ft 0.3 DEN Defautt(8 lbs/sq.ft. ft' ft 0.3 WIC DEN Defauft(8 Ibs/sq.ft. ft' ft 0.3 STAIRS UP Defautt(8 Ibs/sq.ft. ft' ft 0.3 M SITTING AREA Default 8 Ibs/s .ft. ft' ft 0.3 MASTER BEDROO 12/202011:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Softvvare Page 8 of 8 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: GARAFALO RESIDENCE Builder Name: Street: 10751 S. OCEAN DRIVE A13 Permit Office: ST LUCIE COUNTY City, State, Zip: JENSEN BEACH, FL, Permit Number: Y U Owner. Jurisdiction: ST LUCIE COUNTY = Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERI General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks orjoints in the air barter shall be sealed. Ceilinglattic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be Insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per Inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall Include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be Installed at any exposed edge of insulation. Floor framing cavity insulation shall be Installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be In contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided Instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on Installation Narrow cavities readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt Insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior well tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. `a. In addition, inspection of log walls shall be In accordance with the provisions of IGG-400. 12/202011:37 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location varies 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 59.2 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 3291 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.281 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.215 14. Heating system: Capacity 44.0 c) Area 7c. 605.3 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 30.0 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 1082. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a)Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: `/ Date: Address of New Home: 10751 S. OCEAN DRIVE A13 City/FL Zip: JENSEN BEACH, FL 1!2/202011:37:09 AM EnergyGauge(D USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1