Loading...
HomeMy WebLinkAboutProduct Approval -Underlayment811412019 Florida Buldlnq Code Online 11Fjff :w aw Florida *ProductApprowal r V.."1E?[: Pu6lic User ProduCt Aeeroval Menu > Product or Aopllotion Seard+> Apolicd6on Lis[> ApplIMU n Derail Comments Archived Product Manufacturer Boral Rooting Address/Phone/Email 7575 Leine Center Drive suite 100 Irvine, CA 92618 (801) 380-6091 RolomAnderson@boml.com Authorized Signature Thomas Jemmett thomas jemmett@ boral.com Technical Representative Adrian Cooper Address/Phone/Email 135 NW20th Street Boca Raton, FL 33431 (954) 520-5461 acoopeer@minieriifidile_mm Quality Assurance Representative Address/Phone/Email Category R - r-9 Subcategory '7 Undetiayments Compliance Method Evaluation Report firm a Florida Registered Architect ora Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the Robert J. M. Nieminen Evaluation Report Florida License PE -59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/21/2020 Validated By John W. Knezevich, PE i0 Validation Checldist- Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from mr, rl1dP F-14317 UP COI 2018 01 COI NIEMINEN, df Standard ASTM D1970 FRSAIM (April 2017) 04-12 UL 1897 year 2015 2012 2012 PL # h114317 -R10 Application Type 'Y - Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Boral Rooting Address/Phone/Email 7575 Leine Center Drive suite 100 Irvine, CA 92618 (801) 380-6091 RolomAnderson@boml.com Authorized Signature Thomas Jemmett thomas jemmett@ boral.com Technical Representative Adrian Cooper Address/Phone/Email 135 NW20th Street Boca Raton, FL 33431 (954) 520-5461 acoopeer@minieriifidile_mm Quality Assurance Representative Address/Phone/Email Category R - r-9 Subcategory '7 Undetiayments Compliance Method Evaluation Report firm a Florida Registered Architect ora Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the Robert J. M. Nieminen Evaluation Report Florida License PE -59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/21/2020 Validated By John W. Knezevich, PE i0 Validation Checldist- Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from mr, rl1dP F-14317 UP COI 2018 01 COI NIEMINEN, df Standard ASTM D1970 FRSAIM (April 2017) 04-12 UL 1897 year 2015 2012 2012 8/1412019 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved FL # Model, Humber or Name y� 14317.1 Boras Roof Underlaymen s Florida Building Code Online Method 1 Option D 10/17./2018 10/15/2018 10/22/2018 12/11=18 Description Roof underlayments for use in prepared root assemblies Limits of Use Installation Instructions Approved for use in HVHZ: No FL14317 RIO IF 2018 10 FINAL ER BORAL Underla ents F114317 - Approved for use outside HVHZ Yes R10.Ddf Impact Resistant: N/A Verified By: Robert 7. M. Nieminen PE- 59166 Design pressure: +N/A/ --210 Created by Independent Third Party: Yes Other. 1.) The design pressure in this application Evaluation Reports j pertains to a particular undedayment system Cor use E14317 RIO AE 2018 10 FINAL ER BORAL Underlavments FL14317- under foam -on file systems. Refer to ER Section R10"ndf 5.6.4. 2.) Refer to ER Section 5 for limits of Use. Created by Independent Word Party: Yes f lzgt us :: 2601 atatrsM noari Tail ham F132399 Phone: fl$n 68>-18]R The Sat¢ of Flndda Is an AWF20 employen Capvrinht 201r/-2tla3 Stall of Florlaa :: PrNai Spt¢m¢nt.: gpmVb'pU.Statem :; R¢rnnd SLatemeM Vnder Randa law, ureal addresses are VOW records„ Sfyou do not w0.tw.r a -mad address released in response to a pubr.,remNs requesl, do asend elerhonic :nal to this WOW'rulead, euntact the O fiee by Phone or by badipanal mail. ffyou have ary questions, please mnbdt a90417J395.'prrtswntM Section 455.]75(1), Rmtda Statute s„¢Ired nctnber1,ZUl2,hmnsees thell under Chaverenn F,s_must Provide the oeParbnentwtth an ¢mad adtlressffMey have ane The ernals provided May beused raroifipaicommuniee, mh the licenseeuoweveroGthe addressesare robrm record. Ifyqu do not wish to supply permrlal addnss, please provide the nepartmbrtnnTh an email atldnss which can be made avalabh!tq the publo. To de1¢mrine IF you are a ff n under Chapter 45s, FS., ply dick here. V dvut Avv .mi Aecepts; i;;n1�Y�C n ti,: ENGINEER EVALUATE Boral Roofing 7575 Irvine Center ®rive, Suite 100 Irvine, CA. 92618 (602) 269-2288 TEST CONSULT Certificate ofAuMorzWhoa#32453 353 Christian Street, Unit #13 Oxford, Cr 06478 (203)262-9245 Report M357101210 -R11 FU4317-RIO ®ate of Issuance: 12/21/2010 Revision 11:10/12/2018 scope: This Evaluation Report is issued under Rule 616203, and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6"' Edition (2017) Florida Building Code sections noted herein_ %DEscwPrtoN: Boral Roof Underlayments LAnEuNG: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONRNn® COMPUANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P -E. of any changes to the product(s), the Quality Assurance or the production facility location(s)- MEMO ETC, LLC requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle_ AovverrisEMenn: The Evaluation Report number preceded by the words "NEMOI etc Evaluated' may be displayed in advertising literature_ If any portion of the Evaluation Report is displayed, then it shall be done in its entirety_ INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official This Evaluation Report consists of pages 1 through S. Prepared by: RObert9.M. Nieminen, P.E. Florida Regetrntion No. $9166, Florida ACA ANE"83 The faoim deseal appearing wdsautho,ixed by Robed: Nieminen. P_E^n "=M& does nM.s as an CARMURCAW014 OF fi;ua _ mMCE: eleetra^'�nYsgned d^wmenG L NEMO ETC, LLC does not have, nor does it intend to acquire or aviil it acquire, a financial interest in any company manufacturing or distributing products it evaluates_ Z NEMO ETG LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3_ Robert Nieminen, P_E, doesports are being issueednot have nor d. acquire, Which the evaluation reporta financial iltterest in any company manufacturing or distributing products for 4. Robert Nieminen, P -F— does not have, nor will acquire, a finandal interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMO EFC, LLC nor Robert Nieminen, P_E. are, in any way, the Designer of Record'.for any project on which this Evaluation Report or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose_ ROORNG COMPONENT EMUA7ION: 1507.2.9.2 15073.3 Physical Properties FRSA/Ml April 2012 (0412) 2012 Entity Examination HE Reference Date ERD (TST 6049) Physical Properties M36790A7.11 09/30/20U ERD O -ST 6049) Physical Properties 840380.08.12 08/28/2012 ERD (TST 6049) Tensile Adhesion / CTA C41420.09.12-2 09/71/2012 ERD(IST 6049) Adhesion 841940.09.72 09/13/2012 ERD (TST 6049) Tensile Adhesion / LTA B47390.07.14-1 07/31/2014 ERD (TST 6049) Tensile Adhesion / LTA 847390.0914 09/04/2014 OC (POM1838) Physical Properties Equivalencystatement 11/02/2017 PRI (TST5878) ASTM D1970 NEM31-02-02--REV 10/27/2010 PRI (TST5878) ASTM 01970 NEI-029-02-01:REV 12/03/2010 PRI MT 5878) Tensile Adhesion/LTA NEI.046-02-MREV 12/17/2010 PRI(TSTS878) FRSAjTRI April 2012 NEI -076-02-M 02/14/2011 PRI (TSF 5878) ASTM D1970 NEI -034-02-02 01/29/2013 PRI (TST 5878) Wind Uplift BORR-001-02 Ol 03/17/2015 PRI (T51`5878) Wind Uplift 13ORR-005-02-01 06/24/2015 PRI M -T5878) Tensile Adhesion / LTA DAPr-002-02-01 03/08/2018 PRI (T5T5878) ASTM 01970 (adhesion) OCF 43-02-01 10/17./2018 UL, LLC. (QUA 9625) Quality Assurance Service Confirmation Exp_ 08/21/2020 4.1 BoralO TileSeal So" is a nominal 50 -mil underlayment; meets ASTM D197M self -adhering SBS modified bitumen roof X-4.2 Boralo TileSeal"r is a nominal 60 -mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TR104-12. 43 Boralo IVletalSeaff is a nominal 60 -mil thick, polyester -surfaced, sell -adhering SBS modified bitumen roof underlayment; meets ASTM D1970 and R SA/TRI 0412. 4.4 GatorSeal® is a nominal 55 -mil thick, granular -surfaced, fiberglass reinforced, self-adherings6S modified bitumen roof underlayment; meets ASTM D7970. 4.5 Citadel® Pius is a nominal 48 -mil thick, fabric -Surfaced, fiberglass reinforced, self -adhering SBS modified bitumen roofing underlayment for use as a base -layer in multi -ply underlayment systems; meets ASTM 07970_ NEMOCedgk ETa;ALC Euahration RePart M35710J210-R71 CerLT�enf/�+Rharan lia+�+Y3ZF55 6TM EDMON(2017)FRC NON-MR$EVVALUATION R14317 -Rin Bora) Roof Umlerlaymems� (602) 269-2288 nevsion Si ]A/I2/;pys Pagezor8 5_1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Niernmen, P -F- are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Boral Roof t/nderlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering_ SS Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by4tself beneath the stated roof covers. Refer to the installation instructions for multi -ply underlayment options. ,. . r• . Underlayment $Asphall'tt NaiFOn TileAdh Tile Metal Mutes/ Wood Shakes Site &Shingles Boral TileSeal 50" Yes No No Yes Yes yes Boral TileSealw YeS,Yes Yes Yes Yes Yes (see 5.5.1) Boral MetalSeaff Yes Yes Yes Yes Yes Yes (5ee 5-51) GatorSeal Yes No_. _ NoI No Yes Yes 55.1 'Adhesive -set Tile" is limited to use of following Approved the adhesives / underlayment combinations. Adhesive Florida Product _.... _ Approval Underiaymems DAP Foam Touch 'n Seal Stormeond Roof Tile Adhesive FLt4506 Boral TileSeal" or Boral MetalSealur DAP Foam Touch 'n Seal Stonn6ond 2 Two -Component Polyurethane Roof Tile Adhesive FL21374 Bora( TileSealm or Boral MetalSeaF Dow TILE BOND— Roof Tile Adhesive FL22525 Boral TileSealw or Soral Metat;ealur ICP Adhesnres Patysete AH -160 FL63B2 Baral Tile$eatur or Bora) MeialSealur ICP Adhesives PolyseY°RTA-1 _. _.. FC6276 Borst TBesealvr or Boral MetatSealu�' s Refer to Trle Munufacturer's or Adhesive Manufacwr"--1 Florida Pro ductApprovol for 0wrtumIng Moment Resistance Performance_ NEMO ETC, uc QW6fiarteofAmharizutiortk32455 6r"EDMON(2017)F13C NON-HVNZ EVALVAMON EVaIr1ation Report 4435710-12.10-rul Sarni Rant VnderW FU4317-RSO ]pnentr I6O21269-228$ R¢v8ian SL ]n/]27�nIB eage3 of 8 ONEMOJetC. 5.6 Allowable Substrates: 5.6,1 Direct -Bond to Deck: Citadel Plus, Boral TileSeai 50" Boral TileSeal" ; Boral MetalSeaiw or GatorSeal: ➢ Plywood (unprimed or primed with ASTM D41 primer). Boral TIIeSeal" or Boral Meta(Seal"T: ➢ OSB (unprimed or primed with ASTM D41 primer). Note. Refer to Section 506.4 far apW AmMatons associated with direct -deck underloyment installations where the overlying roof cover is adhesive -set file waling 5.6.2 Bond to Base layer Underlayment: Citadel Plus, Boral TileSeal 50' Boral TileSeal"T, Boral MetalSeal"T or GatorSeal: ASTM D226, Type 11 felt; Gtadel Plus. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under adhesive -set tile systems, base layershall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC 1504.3.1. 5.63 Bond to Other SubstrateTvnes: Citadel Plus, Boral TileSeal 50" ; Boral TileSeai" ; Boral MetaiSeal"T or GatorSeal- ➢ ASTM D4.1 primed metal (e.g., flashing metal, valley metal, etc.). Boras TileSeal"T. A Huber Zip Deck (unprimed or primed with ASTM D41 primer); Dens Deck Prime. Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval 5.6.4 Wind Resistance for Underlayment Svstems in Adhesive set Tile Applications: FRSA(M April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath adhesive -set file systems, where the underlayment forms part of the load -path. The followingg wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in adhesive -set the applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSAITRI Apnil 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads #1 Maximum Design Pressure =-9.20 0 most: Deck: Min_ 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction_ Primer: (Optional) ASTM D41 to the plywood deck Base Ply: Citadel Plus, self -adhered Cap Sheet Boral TileSealworBoral MetalSea(";self-adhered, and back -nailed within the selvedge -edge side laps using 12 ga_ x 1X" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12 -inch o.c. #2 Maximum Desien Pressure= -1425 nsF Deck: Min_ 15132 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. . Base Ply: None Cap Sheet. Boral TileSealwor Boral MetalSeal" ; self -adhered and back -nailed vVithin the selvedge-edgeside laps using 12 ga_ x 1"/." ring shank nails through 32 ga_,15/8" diameter tin caps spaced 12 -inch o_c. NEMo ETC, LLC xh Emluati= Report Nr3S710.17-104UI Ce10fiLute vfAvtliv rzvtion M24559"- EDMON(2017) FBC NOW4"Z EVAWATiON 1`114317-R30 evrai Raor Onderlaym ,, (602)) 269-222 ptevrsion 1110/12/2= PageaoFS ONEMOletc. #3 Maximum Design Pressure= -202.5 Pssf: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer Tropical Roofing Products #410 quick Dry Primer or other ASTM D41 primer to the plywood deck Base Ply, None Cap Sheet: Boral TileSealmorBoral Meta➢Seal";self-adhered, and back -nailed within the selvedge-edgeside laps using 12 ga_ x 116" ring shank nails through 32 ga-,15/8" diameter tin raps spaced 124nch os. #4 Maximum Design Pressure= -210.0 psF: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: KARNAK #89 StaTak Primer to the plywood deck Base Ply_ None Cap Sheet: BOralTileSealmrorBoral MetalSealn;self-adhered, and back -nailed within the seivedge-edge side laps using 12 ga. x 1'/<" ring shank nails through 32 ga.,15/8" diameter Un caps spaced 124nch o.c. #5 Maximum Design Pressure= -320-(8 i�sf: Deck: Min_ 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction, PrimerASTM D41 to the concrete deck Base Ply: (Optional) Citadel Plus, self -adhered Cap Sheet Boral TileSealt1' or Boral MetalSealn ; self -adhered 5.6.4,1 Note: For adhesive -set file systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design Pressure requirements may not exceed -120 psf_ 5,7 Exposure limitations: GatorSeal shall not be left exposed for longerthan 30 -days after installation, priorto placement of final roof cover. Boral TOeSeal 5o'{ ; Baral TeleSeal"' or Boral Metalsealw shall not be left exposed for longer than Igo -days after installation, prior to placement of final roof cover_ Citadel Plus, for use as a base -layer in a multi -ply underlayment system, shall not be left exposed for longer than .180 -days after installation, priorto placement of subsequent underlayment layer, 5,8 Tele S➢ippa_ge 0.imitaiions rPRCA/4'(ZI April 21b92 (04 I2➢7- When loading roof tiles on the underlayment in direct -deck file assemblies, the maximum roof slope shall be as follows_ These slope limitations can Only be exceeded by using battens during loading of the roof tiles_ Tile Profile EM 6:12 6:12 6.1 Boral Roof Underlayments shall be installed in accordance with Doral Roofing published installation instructions subject to the Urnitations set forth in Section 5 herein and the specifics noted below, 6.2 Re -fasten any loose decking panels, and check for protruding nail heads_ Sweep the substrate thoroughly to remove any dust and debris Prior to application, and prime the substrate rif applicable). 6.3 Install self -adhering underlayment when ambient and surface temperatures are minimum 40`F and rising, MEMO ETC,LLC CMOEvaluation Report W57.E012.10-R11 erlifimteoFaurhorixutiortda2a55 6- EDMON(20M FRC MON-HVHZ EVAIUAT(ON FU4317-RSO Dora! rtooF UndedaymenM (602) ZG9-,7200 Re"Caan li-"IW2o rage 5 ora ONEMOJek. 6.4 Citadel Plus: 6.4-1 Citadel Plus is limited to use as a base or mid -layer in mufti -ply underlayment systems beneath Boral TileSeal 50111 Boral TileSeal"T or GatorSeal. 6,4.2 Slope limitations are those associated with the top -layer underlayment 6.43 Direct to Deck: Cut the membrane into manageable lengths, typically 10 to 12 it. Align the membrane parallel to the roof edge, extending over by'/< -inch. Fold the membrane away from the edge onto itself. Remove the release sheet Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the top edge of the sheet to the deck with corrosion resistant roofing nails, nails & tin -tags or 1-inrh diameter plastic or steel cap nails spaced maximum 124inch o.c. Overlap successive courses the entire width of the black -selvedge area, minimum 2 inches (horizontal lap) and minimum 6" end (vertical) laps_ Install final underlayment layer atop Citadel Plus per'direct-to-deck' instructions for Boral TileSeal 50111 Boral TileSeal" ; Boral MetalSeal"r or GatorSeal. 6A_4 To Base Sheet_ Install base sheet of ASTM D226, Type 11 felt in accordance with Code requirements or install base ply of Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4.3 and when used as part of a multi -ply system. Install optional Citadel Plus as a mid -ply in accordance with Boral Roofing published installation instructions and Section 6-43, Install final underlayment layer atop Citadel Plus per 'direct to -deck' instructions for Boral TileSeai 50" Boral TileSeal"T or GatorSeal. Note: For adhesive -set file systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design pressure requirements may not exceed -120 psf 6-5 Boral l9leSeal 50"r- 6-5.1 Shall be installed in compliance with the requirements for ASTM 01970 underlayment in FSC Table 1507.1,1 for the type of prepared roof covering to be installed. 6.5.2 Do not use Boral TileSeal 50"r on roof pitches Bess than 2:12- 6-5-3 Non -Tile Lk Dlications Direct to Deck. Cut the membrane into manageable lengths, typically 10 to 12 ft Align the membrane parallel to the roof edge, extending over by Y -inch. Fold the membrane away from the edge onto itself. Remove the release sheet Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails & tin -tags or 1 -inch diameter plastic or steel cap nails spaced maximum 24 -inch o_c for slopes below 7:1Z and maximum 12 -inch 0 r- for slopes 7.12 and greater. Overlap successive courses the entire width of the black -selvedge area, minimum 3 -inch - Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam method detailed in Boral Roofing published installation instructions. MEMO EFC, LLC #32455 Grb]im�afAutfiarirorion Ewiluation Repan M3'i71012JD-R]1 6'" EDITION (2017) F13C NON-HV14Z EVALUATION R14317 -RID Harm Roof Underlayments, (602) Z69-2288 Revaion 1p: 38117/20]8 Page 6 ofa ONEMOjek. 6.5.4 Non Tile Aeplications, to Base Sheet: Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4, Install Boral TileSeal 50' in accordance over ASPM D226, Type 11 felt or Citadel Plus with Boral Roofing published installation instructions and Section 65.3, except end (vertical) laps, described below. Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the fabric top surface, rolling the interface into place with a weighted roller_ 6.6 Gator5eal: 6.61 Shall be installed In compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.6.2 Do not use GatorSeal on roof pitches less than 2:1.2. 6.6.3 Non -Tile anplicaf3ons Direct to Deck Cut the membrane into manageable lengths, typically 10 to 32 ft Align the membrane parallel to the roof edge, extending over by Y. -inch. Fold the membrane away from the edge onto itself_ Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails & tin tags or 1 -inch diameter plastic or steel cap nails spaced 24 inch o.c. for slopes below 7.12 and 12 -inch o.c for slopes 7.12 and greater. Overlap successive courses the entire width of the black -selvedge area, minimum 3 -inch. Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps -where the self -adhering bituminous underside is in contact with the granular or mineral top surface, rolling the interface into place with a weighted roller, or using the Inverted Sheet Seam detailed in Boral Roofing published installation instructions. 6.6.4 Non -Tile Applications to Base Sheet Install ASrIVI D226, Type ft felt in accordance with Code requirements or install Citadel Plus in accordance with Rural Roofing published installation instructions and 5ecdon 6.4. install Gatorseal overASTM D226, Type 11 felt or Citadel Plus in accordance with Bora) Roofing published installation instructions and Section 6.6.3 except end (vertical) laps, described below. Apply SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the granular top surface, rolling the interface into place with a weighted roller. 6.7 oral TileSeal or Rural Metalsealm 6.7.1 Shall be installed in compliance with the requirements for ASTM 01970 underlayment in FBC Table 1507.L1 for the type of prepared roof covering to be installed_ 6.7.2 Do not use Boral TileSeall or Boral MetalSeal"r on roof pitches less than 2.12. 6.7.3 Non -Tile Applications Direct to Deck. For OSB substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by''/< -inch_ Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck Pressing firmly into place. Roll into place with a weighted roller.'. Fasten the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1 -inch diameter plastic or steel cap nails spaced maximum 12 -inch o.c. Overlap successive courses the entire width of the black -selvedge area, minimum 3 -inch. Seal under ail end (vertical) laps using approved mastic or use Inverted Sheet Seam method detailed in Boral Roofing published installation instructions. MEMO FTC, LLC '"Ybr" fA.th t ' #324, 6"' EomoN (ZoX7) pec Mowuv 12 EVALUATION E�l"aI'on report M35710.SZ1p.Rtt 130ra1 Roof Unde4ayrneaN (6o2) 269 22= 814317 --Ria Revision i]. 30/12IM" Page 7 cfR ub) N E M 0 1 etC. 6.7.4 Non -Tile Applications, to Base Sheet Install ASTM D226, Type 11 felt in accordance with Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install Boral TileSeal"T or Boral MetaLSeal'n over ASTM D226, Type 11 felt or Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.7.3, except end (vertical) laps, described below; Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the fabric top surface, roiling the interface into place with a weighted roller. 6.75 Tile Applications: Reference is made to FRSA/TRI April 2032 (04-12) Installation Manual and Table .& herein, using the instructions noted above as a guideline. For mechanically fastened file roofing over 2 -ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRM April 2012 (0432), Table i For adhesive -set tile applications, refer to Section S.&4 herein. Note: For adhesive -set file systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design pressure requirements may not exceed -320 psf Refer to Section 5.8 for file staging limitations. Battens must be used for all tile installations atop Boral TileSeaF or Boral MetalSeaff with roof pitches of 2Y2 to less than 3:32_ Boral Roofing's Elevated Batten System or counter battens are required. A M As required bythe Building Official or Authority Having3urisdiction in orderto properly evaluate the installation of this product. Brentwood, NH UL, LLC —QUA9625; (631) 546-2458; KanchiJigrawala-DokaniaCn�ul.com - END OF EVALUATION REPORT - NEMO ErC LLC rWuaion Report U35710.3230 -Mi C.ItgV .f ArrtLariza..#3.245 STM EDMON(Z0M FBC NON-HV14Z EVALUATOM F(14317 -Rio florae noot unde,bynvenf� (soz) 26o-zz0o nom u. ao/u/�o�s Page 8 of 8