HomeMy WebLinkAboutProduct Approval -Underlayment811412019 Florida Buldlnq Code Online
11Fjff
:w aw
Florida *ProductApprowal
r
V.."1E?[: Pu6lic User
ProduCt Aeeroval Menu > Product or Aopllotion Seard+> Apolicd6on Lis[> ApplIMU n Derail
Comments
Archived
Product Manufacturer Boral Rooting
Address/Phone/Email 7575 Leine Center Drive
suite 100
Irvine, CA 92618
(801) 380-6091
RolomAnderson@boml.com
Authorized Signature Thomas Jemmett
thomas jemmett@ boral.com
Technical Representative Adrian Cooper
Address/Phone/Email 135 NW20th Street
Boca Raton, FL 33431
(954) 520-5461
acoopeer@minieriifidile_mm
Quality Assurance Representative
Address/Phone/Email
Category R - r-9
Subcategory '7 Undetiayments
Compliance Method Evaluation Report firm a Florida Registered Architect ora Licensed Florida
Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M. Nieminen
Evaluation Report
Florida License PE -59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/21/2020
Validated By John W. Knezevich, PE
i0 Validation Checldist- Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from mr, rl1dP
F-14317 UP COI 2018 01 COI NIEMINEN, df
Standard
ASTM D1970
FRSAIM (April 2017) 04-12
UL 1897
year
2015
2012
2012
PL #
h114317 -R10
Application Type
'Y - Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer Boral Rooting
Address/Phone/Email 7575 Leine Center Drive
suite 100
Irvine, CA 92618
(801) 380-6091
RolomAnderson@boml.com
Authorized Signature Thomas Jemmett
thomas jemmett@ boral.com
Technical Representative Adrian Cooper
Address/Phone/Email 135 NW20th Street
Boca Raton, FL 33431
(954) 520-5461
acoopeer@minieriifidile_mm
Quality Assurance Representative
Address/Phone/Email
Category R - r-9
Subcategory '7 Undetiayments
Compliance Method Evaluation Report firm a Florida Registered Architect ora Licensed Florida
Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M. Nieminen
Evaluation Report
Florida License PE -59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/21/2020
Validated By John W. Knezevich, PE
i0 Validation Checldist- Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from mr, rl1dP
F-14317 UP COI 2018 01 COI NIEMINEN, df
Standard
ASTM D1970
FRSAIM (April 2017) 04-12
UL 1897
year
2015
2012
2012
8/1412019
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
FL # Model, Humber or Name
y� 14317.1 Boras Roof Underlaymen s
Florida Building Code Online
Method 1 Option D
10/17./2018
10/15/2018
10/22/2018
12/11=18
Description
Roof underlayments for use in prepared root assemblies
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL14317 RIO IF 2018 10 FINAL ER BORAL Underla ents F114317 -
Approved for use outside HVHZ Yes
R10.Ddf
Impact Resistant: N/A
Verified By: Robert 7. M. Nieminen PE- 59166
Design pressure: +N/A/ --210
Created by Independent Third Party: Yes
Other. 1.) The design pressure in this application
Evaluation Reports j
pertains to a particular undedayment system Cor use
E14317 RIO AE 2018 10 FINAL ER BORAL Underlavments FL14317-
under foam -on file systems. Refer to ER Section
R10"ndf
5.6.4. 2.) Refer to ER Section 5 for limits of Use.
Created by Independent Word Party: Yes
f lzgt us :: 2601 atatrsM noari Tail ham F132399 Phone: fl$n 68>-18]R
The Sat¢ of Flndda Is an AWF20 employen Capvrinht 201r/-2tla3 Stall of Florlaa :: PrNai Spt¢m¢nt.: gpmVb'pU.Statem :; R¢rnnd SLatemeM
Vnder Randa law, ureal addresses are VOW records„ Sfyou do not w0.tw.r a -mad address released in response to a pubr.,remNs requesl, do asend elerhonic
:nal to this WOW'rulead, euntact the O fiee by Phone or by badipanal mail. ffyou have ary questions, please mnbdt a90417J395.'prrtswntM Section 455.]75(1),
Rmtda Statute s„¢Ired nctnber1,ZUl2,hmnsees thell under Chaverenn F,s_must Provide the oeParbnentwtth an ¢mad adtlressffMey have ane The ernals
provided May beused raroifipaicommuniee, mh the licenseeuoweveroGthe addressesare robrm record. Ifyqu do not wish to supply permrlal addnss, please
provide the nepartmbrtnnTh an email atldnss which can be made avalabh!tq the publo. To de1¢mrine IF you are a ff n under Chapter 45s, FS., ply dick here.
V dvut Avv .mi Aecepts;
i;;n1�Y�C n
ti,:
ENGINEER EVALUATE
Boral Roofing
7575 Irvine Center ®rive, Suite 100
Irvine, CA. 92618
(602) 269-2288
TEST CONSULT
Certificate ofAuMorzWhoa#32453
353 Christian Street, Unit #13
Oxford, Cr 06478
(203)262-9245
Report M357101210 -R11
FU4317-RIO
®ate of Issuance: 12/21/2010
Revision 11:10/12/2018
scope:
This Evaluation Report is issued under Rule 616203, and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6"' Edition (2017) Florida Building Code sections noted
herein_
%DEscwPrtoN: Boral Roof Underlayments
LAnEuNG: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONRNn® COMPUANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P -E. of any changes to the
product(s), the Quality Assurance or the production facility location(s)- MEMO ETC, LLC requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle_
AovverrisEMenn: The Evaluation Report number preceded by the words "NEMOI etc Evaluated' may be displayed in
advertising literature_ If any portion of the Evaluation Report is displayed, then it shall be done in its entirety_
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official
This Evaluation Report consists of pages 1 through S.
Prepared by:
RObert9.M. Nieminen, P.E.
Florida Regetrntion No. $9166, Florida ACA ANE"83
The faoim
deseal appearing wdsautho,ixed by Robed:
Nieminen. P_E^n "=M& does nM.s as an
CARMURCAW014 OF fi;ua _ mMCE: eleetra^'�nYsgned d^wmenG
L NEMO ETC, LLC does not have, nor does it intend to acquire or aviil it acquire, a financial interest in any company manufacturing or
distributing products it evaluates_
Z NEMO ETG LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3_ Robert Nieminen, P_E, doesports are being issueednot have nor d. acquire,
Which the evaluation reporta financial iltterest in any company manufacturing or distributing products for
4. Robert Nieminen, P -F— does not have, nor will acquire, a finandal interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NEMO EFC, LLC nor Robert Nieminen, P_E. are, in any way, the Designer of Record'.for any
project on which this Evaluation Report or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose_
ROORNG COMPONENT EMUA7ION:
1507.2.9.2
15073.3
Physical Properties
FRSA/Ml April 2012 (0412)
2012
Entity
Examination
HE
Reference
Date
ERD (TST 6049)
Physical Properties
M36790A7.11
09/30/20U
ERD O -ST 6049)
Physical Properties
840380.08.12
08/28/2012
ERD (TST 6049)
Tensile Adhesion / CTA
C41420.09.12-2
09/71/2012
ERD(IST 6049)
Adhesion
841940.09.72
09/13/2012
ERD (TST 6049)
Tensile Adhesion / LTA
B47390.07.14-1
07/31/2014
ERD (TST 6049)
Tensile Adhesion / LTA
847390.0914
09/04/2014
OC (POM1838)
Physical Properties
Equivalencystatement
11/02/2017
PRI (TST5878)
ASTM D1970
NEM31-02-02--REV
10/27/2010
PRI (TST5878)
ASTM 01970
NEI-029-02-01:REV
12/03/2010
PRI MT 5878)
Tensile Adhesion/LTA
NEI.046-02-MREV
12/17/2010
PRI(TSTS878)
FRSAjTRI April 2012
NEI -076-02-M
02/14/2011
PRI (TSF 5878)
ASTM D1970
NEI -034-02-02
01/29/2013
PRI (TST 5878)
Wind Uplift
BORR-001-02 Ol
03/17/2015
PRI (T51`5878)
Wind Uplift
13ORR-005-02-01
06/24/2015
PRI M -T5878)
Tensile Adhesion / LTA
DAPr-002-02-01
03/08/2018
PRI (T5T5878)
ASTM 01970 (adhesion)
OCF 43-02-01
10/17./2018
UL, LLC. (QUA 9625)
Quality Assurance
Service Confirmation
Exp_ 08/21/2020
4.1 BoralO TileSeal So" is a nominal 50 -mil
underlayment; meets ASTM D197M
self -adhering SBS modified bitumen roof
X-4.2 Boralo TileSeal"r is a nominal 60 -mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TR104-12.
43 Boralo IVletalSeaff is a nominal 60 -mil thick, polyester -surfaced, sell -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970 and R SA/TRI 0412.
4.4 GatorSeal® is a nominal 55 -mil thick, granular -surfaced, fiberglass reinforced, self-adherings6S modified bitumen
roof underlayment; meets ASTM D7970.
4.5 Citadel® Pius is a nominal 48 -mil thick, fabric -Surfaced, fiberglass reinforced, self -adhering SBS modified bitumen
roofing underlayment for use as a base -layer in multi -ply underlayment systems; meets ASTM 07970_
NEMOCedgk
ETa;ALC Euahration RePart M35710J210-R71
CerLT�enf/�+Rharan lia+�+Y3ZF55 6TM EDMON(2017)FRC NON-MR$EVVALUATION R14317 -Rin
Bora) Roof Umlerlaymems� (602) 269-2288 nevsion Si ]A/I2/;pys
Pagezor8
5_1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Niernmen, P -F- are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for
fire ratings of this product.
5.4 Boral Roof t/nderlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering_
SS Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by4tself beneath the stated roof
covers. Refer to the installation instructions for multi -ply underlayment options.
,. . r• .
Underlayment $Asphall'tt NaiFOn TileAdh Tile Metal
Mutes/ Wood Shakes Site
&Shingles
Boral TileSeal 50" Yes No No Yes Yes yes
Boral TileSealw YeS,Yes
Yes Yes Yes Yes
(see 5.5.1)
Boral MetalSeaff Yes Yes Yes
Yes Yes Yes
(5ee 5-51)
GatorSeal Yes No_. _ NoI No Yes Yes
55.1 'Adhesive -set Tile" is limited to use of following Approved the adhesives / underlayment combinations.
Adhesive
Florida Product
_.... _
Approval
Underiaymems
DAP Foam Touch 'n Seal Stormeond Roof Tile Adhesive
FLt4506
Boral TileSeal" or Boral MetalSealur
DAP Foam Touch 'n Seal Stonn6ond 2 Two -Component
Polyurethane Roof Tile Adhesive
FL21374
Bora( TileSealm or Boral MetalSeaF
Dow TILE BOND— Roof Tile Adhesive
FL22525
Boral TileSealw or Soral Metat;ealur
ICP Adhesnres Patysete AH -160
FL63B2
Baral Tile$eatur or Bora) MeialSealur
ICP Adhesives PolyseY°RTA-1
_. _..
FC6276
Borst TBesealvr or Boral MetatSealu�'
s Refer to Trle Munufacturer's or Adhesive Manufacwr"--1 Florida Pro ductApprovol for 0wrtumIng Moment Resistance Performance_
NEMO ETC, uc
QW6fiarteofAmharizutiortk32455 6r"EDMON(2017)F13C NON-HVNZ EVALVAMON EVaIr1ation Report 4435710-12.10-rul
Sarni Rant VnderW FU4317-RSO
]pnentr I6O21269-228$ R¢v8ian SL ]n/]27�nIB
eage3 of 8
ONEMOJetC.
5.6 Allowable Substrates:
5.6,1 Direct -Bond to Deck:
Citadel Plus, Boral TileSeai 50" Boral TileSeal" ; Boral MetalSeaiw or GatorSeal:
➢ Plywood (unprimed or primed with ASTM D41 primer).
Boral TIIeSeal" or Boral Meta(Seal"T:
➢ OSB (unprimed or primed with ASTM D41 primer).
Note. Refer to Section 506.4 far apW AmMatons associated with direct -deck underloyment installations where the
overlying roof cover is adhesive -set file waling
5.6.2 Bond to Base layer Underlayment:
Citadel Plus, Boral TileSeal 50' Boral TileSeal"T, Boral MetalSeal"T or GatorSeal:
ASTM D226, Type 11 felt; Gtadel Plus.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under adhesive -set tile systems, base layershall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested
in accordance with FBC 1504.3.1.
5.63 Bond to Other SubstrateTvnes:
Citadel Plus, Boral TileSeal 50" ; Boral TileSeai" ; Boral MetaiSeal"T or GatorSeal-
➢ ASTM D4.1 primed metal (e.g., flashing metal, valley metal, etc.).
Boras TileSeal"T.
A Huber Zip Deck (unprimed or primed with ASTM D41 primer); Dens Deck Prime.
Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval
5.6.4 Wind Resistance for Underlayment Svstems in Adhesive set Tile Applications: FRSA(M April 2012 (04-12) does
not address wind uplift resistance of all underlayment systems beneath adhesive -set file systems, where the
underlayment forms part of the load -path. The followingg wind uplift limitations apply to underlayment systems
that are not addressed in FRSA/TRI April 2012 (04-12) and are used in adhesive -set the applications. Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the
ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer
to FRSAITRI Apnil 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads
#1 Maximum Design Pressure =-9.20 0 most:
Deck: Min_ 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction_
Primer: (Optional) ASTM D41 to the plywood deck
Base Ply: Citadel Plus, self -adhered
Cap Sheet Boral TileSealworBoral MetalSea(";self-adhered, and back -nailed within the selvedge -edge side laps
using 12 ga_ x 1X" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12 -inch o.c.
#2 Maximum Desien Pressure= -1425 nsF
Deck: Min_ 15132 -inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction. .
Base Ply: None
Cap Sheet. Boral TileSealwor Boral MetalSeal" ; self -adhered and back -nailed vVithin the selvedge-edgeside laps
using 12 ga_ x 1"/." ring shank nails through 32 ga_,15/8" diameter tin caps spaced 12 -inch o_c.
NEMo ETC, LLC
xh Emluati= Report Nr3S710.17-104UI
Ce10fiLute vfAvtliv rzvtion M24559"- EDMON(2017) FBC NOW4"Z EVAWATiON 1`114317-R30
evrai Raor Onderlaym ,, (602)) 269-222 ptevrsion 1110/12/2=
PageaoFS
ONEMOletc.
#3 Maximum Design Pressure= -202.5 Pssf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer Tropical Roofing Products #410 quick Dry Primer or other ASTM D41 primer to the plywood deck
Base Ply, None
Cap Sheet: Boral TileSealmorBoral Meta➢Seal";self-adhered, and back -nailed within the selvedge-edgeside laps
using 12 ga_ x 116" ring shank nails through 32 ga-,15/8" diameter tin raps spaced 124nch os.
#4 Maximum Design Pressure= -210.0 psF:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: KARNAK #89 StaTak Primer to the plywood deck
Base Ply_ None
Cap Sheet: BOralTileSealmrorBoral MetalSealn;self-adhered, and back -nailed within the seivedge-edge side laps
using 12 ga. x 1'/<" ring shank nails through 32 ga.,15/8" diameter Un caps spaced 124nch o.c.
#5 Maximum Design Pressure= -320-(8 i�sf:
Deck: Min_ 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction,
PrimerASTM D41 to the concrete deck
Base Ply: (Optional) Citadel Plus, self -adhered
Cap Sheet Boral TileSealt1' or Boral MetalSealn ; self -adhered
5.6.4,1 Note: For adhesive -set file systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
Pressure requirements may not exceed -120 psf_
5,7 Exposure limitations:
GatorSeal shall not be left exposed for longerthan 30 -days after installation, priorto placement of final roof cover.
Boral TOeSeal 5o'{ ; Baral TeleSeal"' or Boral Metalsealw shall not be left exposed for longer than Igo -days after
installation, prior to placement of final roof cover_
Citadel Plus, for use as a base -layer in a multi -ply underlayment system, shall not be left exposed for longer than
.180 -days after installation, priorto placement of subsequent underlayment layer,
5,8 Tele S➢ippa_ge 0.imitaiions rPRCA/4'(ZI April 21b92 (04 I2➢7-
When loading roof tiles on the underlayment in direct -deck file assemblies, the maximum roof slope shall be as
follows_ These slope limitations can Only be exceeded by using battens during loading of the roof tiles_
Tile Profile
EM
6:12
6:12
6.1 Boral Roof Underlayments shall be installed in accordance with Doral Roofing published installation instructions
subject to the Urnitations set forth in Section 5 herein and the specifics noted below,
6.2 Re -fasten any loose decking panels, and check for protruding nail heads_ Sweep the substrate thoroughly to
remove any dust and debris Prior to application, and prime the substrate rif applicable).
6.3 Install self -adhering underlayment when ambient and surface temperatures are minimum 40`F and rising,
MEMO ETC,LLC
CMOEvaluation Report W57.E012.10-R11
erlifimteoFaurhorixutiortda2a55 6- EDMON(20M FRC MON-HVHZ EVAIUAT(ON FU4317-RSO
Dora! rtooF UndedaymenM (602) ZG9-,7200 Re"Caan li-"IW2o
rage 5 ora
ONEMOJek.
6.4 Citadel Plus:
6.4-1 Citadel Plus is limited to use as a base or mid -layer in mufti -ply underlayment systems beneath Boral TileSeal 50111
Boral TileSeal"T or GatorSeal.
6,4.2 Slope limitations are those associated with the top -layer underlayment
6.43 Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 it. Align the membrane parallel to the roof edge,
extending over by'/< -inch. Fold the membrane away from the edge onto itself. Remove the release sheet Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the top edge of the sheet to the deck with corrosion resistant roofing nails, nails & tin -tags or 1-inrh
diameter plastic or steel cap nails spaced maximum 124inch o.c. Overlap successive courses the entire width of the
black -selvedge area, minimum 2 inches (horizontal lap) and minimum 6" end (vertical) laps_
Install final underlayment layer atop Citadel Plus per'direct-to-deck' instructions for Boral TileSeal 50111 Boral
TileSeal" ; Boral MetalSeal"r or GatorSeal.
6A_4 To Base Sheet_
Install base sheet of ASTM D226, Type 11 felt in accordance with Code requirements or install base ply of Citadel
Plus in accordance with Boral Roofing published installation instructions and Section 6.4.3 and when used as part
of a multi -ply system.
Install optional Citadel Plus as a mid -ply in accordance with Boral Roofing published installation instructions and
Section 6-43,
Install final underlayment layer atop Citadel Plus per 'direct to -deck' instructions for Boral TileSeai 50" Boral
TileSeal"T or GatorSeal.
Note: For adhesive -set file systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf
6-5 Boral l9leSeal 50"r-
6-5.1 Shall be installed in compliance with the requirements for ASTM 01970 underlayment in FSC Table 1507.1,1 for
the type of prepared roof covering to be installed.
6.5.2 Do not use Boral TileSeal 50"r on roof pitches Bess than 2:12-
6-5-3 Non -Tile Lk Dlications Direct to Deck.
Cut the membrane into manageable lengths, typically 10 to 12 ft Align the membrane parallel to the roof edge,
extending over by Y -inch. Fold the membrane away from the edge onto itself. Remove the release sheet Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails & tin -tags or 1 -inch diameter
plastic or steel cap nails spaced maximum 24 -inch o_c for slopes below 7:1Z and maximum 12 -inch 0 r- for slopes
7.12 and greater. Overlap successive courses the entire width of the black -selvedge area, minimum 3 -inch -
Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam
method detailed in Boral Roofing published installation instructions.
MEMO EFC, LLC
#32455
Grb]im�afAutfiarirorion Ewiluation Repan M3'i71012JD-R]1
6'" EDITION (2017) F13C NON-HV14Z EVALUATION R14317 -RID
Harm Roof Underlayments, (602) Z69-2288 Revaion 1p: 38117/20]8
Page 6 ofa
ONEMOjek.
6.5.4 Non Tile Aeplications, to Base Sheet:
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4,
Install Boral TileSeal 50' in accordance over ASPM D226, Type 11 felt or Citadel Plus with Boral Roofing published
installation instructions and Section 65.3, except end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the fabric top surface, rolling the interface into place with a weighted roller_
6.6 Gator5eal:
6.61 Shall be installed In compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.6.2 Do not use GatorSeal on roof pitches less than 2:1.2.
6.6.3 Non -Tile anplicaf3ons Direct to Deck
Cut the membrane into manageable lengths, typically 10 to 32 ft Align the membrane parallel to the roof edge,
extending over by Y. -inch. Fold the membrane away from the edge onto itself_ Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails & tin tags or 1 -inch diameter
plastic or steel cap nails spaced 24 inch o.c. for slopes below 7.12 and 12 -inch o.c for slopes 7.12 and greater.
Overlap successive courses the entire width of the black -selvedge area, minimum 3 -inch.
Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps -where the self -adhering
bituminous underside is in contact with the granular or mineral top surface, rolling the interface into place with a
weighted roller, or using the Inverted Sheet Seam detailed in Boral Roofing published installation instructions.
6.6.4 Non -Tile Applications to Base Sheet
Install ASrIVI D226, Type ft felt in accordance with Code requirements or install Citadel Plus in accordance with
Rural Roofing published installation instructions and 5ecdon 6.4.
install Gatorseal overASTM D226, Type 11 felt or Citadel Plus in accordance with Bora) Roofing published installation
instructions and Section 6.6.3 except end (vertical) laps, described below.
Apply SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the granular top surface, rolling the interface into place with a weighted roller.
6.7 oral TileSeal or Rural Metalsealm
6.7.1 Shall be installed in compliance with the requirements for ASTM 01970 underlayment in FBC Table 1507.L1 for
the type of prepared roof covering to be installed_
6.7.2 Do not use Boral TileSeall or Boral MetalSeal"r on roof pitches less than 2.12.
6.7.3 Non -Tile Applications Direct to Deck.
For OSB substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membrane into
manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by''/< -inch_
Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the
exposed rubberized asphalt onto the deck Pressing firmly into place. Roll into place with a weighted roller.'.
Fasten the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1 -inch diameter plastic or steel
cap nails spaced maximum 12 -inch o.c. Overlap successive courses the entire width of the black -selvedge area,
minimum 3 -inch.
Seal under ail end (vertical) laps using approved mastic or use Inverted Sheet Seam method detailed in Boral
Roofing published installation instructions.
MEMO FTC, LLC
'"Ybr" fA.th t ' #324, 6"' EomoN (ZoX7) pec Mowuv 12 EVALUATION E�l"aI'on report M35710.SZ1p.Rtt
130ra1 Roof Unde4ayrneaN (6o2) 269 22= 814317 --Ria
Revision i]. 30/12IM"
Page 7 cfR
ub)
N E M 0 1 etC.
6.7.4 Non -Tile Applications, to Base Sheet
Install ASTM D226, Type 11 felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install Boral TileSeal"T or Boral MetaLSeal'n over ASTM D226, Type 11 felt or Citadel Plus in accordance with Boral
Roofing published installation instructions and Section 6.7.3, except end (vertical) laps, described below;
Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the fabric top surface, roiling the interface into place with a weighted roller.
6.75 Tile Applications:
Reference is made to FRSA/TRI April 2032 (04-12) Installation Manual and Table .& herein, using the instructions
noted above as a guideline.
For mechanically fastened file roofing over 2 -ply system, consisting of Base Sheet and self -adhering top sheet(s),
Base Sheet fastening shall be not less than FRSA/TRM April 2012 (0432), Table i
For adhesive -set tile applications, refer to Section S.&4 herein.
Note: For adhesive -set file systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -320 psf
Refer to Section 5.8 for file staging limitations. Battens must be used for all tile installations atop Boral TileSeaF
or Boral MetalSeaff with roof pitches of 2Y2 to less than 3:32_ Boral Roofing's Elevated Batten System or counter
battens are required.
A M
As required bythe Building Official or Authority Having3urisdiction in orderto properly evaluate the installation of
this product.
Brentwood, NH
UL, LLC —QUA9625; (631) 546-2458; KanchiJigrawala-DokaniaCn�ul.com
- END OF EVALUATION REPORT -
NEMO ErC LLC rWuaion Report U35710.3230 -Mi
C.ItgV .f ArrtLariza..#3.245 STM EDMON(Z0M FBC NON-HV14Z EVALUATOM F(14317 -Rio
florae noot unde,bynvenf� (soz) 26o-zz0o nom u. ao/u/�o�s
Page 8 of 8